Khalim Conn-Kowlessar f3dcd7b43e fix(elmhurst-mapper): single-storey flat with exposed roof is Top-floor, not Ground-floor
The Elmhurst dwelling-type classifier keyed "Top-floor flat" on a "dwelling
below" floor lodgement. A single-storey flat exposed BOTH top (a real
external roof) AND bottom (floor over partially-heated space, no dwelling
below) therefore fell through to "Ground-floor flat" — which the cascade's
_dwelling_exposure maps to has_exposed_roof=False, dropping the external
roof entirely.

Surfaced by simulated case 34 (cert 001431 reconfigured as a slimline
electric-storage flat): the worksheet bills (30) External roof = 39.98 m²
x U=2.30 = 91.95 W/K — the dominant heat-loss element — but the cascade
dropped it, under-stating space-heating demand by 42% (6550 vs 11357
kWh/yr) and over-predicting SAP by +21.76 (57.07 vs worksheet 35.31).

Fix: an exposed (non-party) roof puts the flat on the top storey
regardless of what is below it. Classify as "Top-floor flat" whenever the
roof is exposed; the flat's exposed floor is recovered downstream by the
existing per-BP is_above_partially_heated_space / is_exposed_floor override
in heat_transmission (§3). Party-roof flats ("another dwelling above") are
unaffected and stay Ground-/Mid-floor.

This is an Elmhurst-mapper (dwelling_type) bug, NOT a calculator bug: the
calculator correctly trusts dwelling_type, and the gov-API path supplies
the position directly (cert 0036 — a genuine ground-floor flat whose API
data lodges a "Pitched, no access" roof construction under another dwelling
— stays party, 2.51 W/K). API SAP gauge unchanged (57.6% within 0.5);
worksheet harness 47/47 unaffected; case 34 roof now exact (residual -1.61
is a separate flat-corridor wall-U thread). Regression gate green (3
pre-existing fails unrelated).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-11 07:23:56 +00:00
..
fixtures fix(elmhurst-mapper): map "Bottled gas" main fuel to bottled LPG, not mains gas 2026-06-10 08:48:15 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py feat(elmhurst-extractor): capture section 15.1 Immersion Heater (Dual/Single) 2026-06-10 22:16:21 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_room_heater_worksheet_001431.py S0380.239: system-build walls take masonry structural infiltration (0.35) 2026-06-05 19:00:02 +00:00