Model/tests/domain
Khalim Conn-Kowlessar f3e3494bf7 test(worksheet): pin simulated case 52 — regular gas boiler + cylinder
Adds the mapper-driven e2e cascade pin for "simulated case 52" (000565
semi + regular non-combi mains-gas boiler SAP 102 + 160 L foam cylinder
heated from the main, no cylinder stat, uninsulated primary pipework,
standard tariff). Routes the Summary PDF through extractor + mapper +
calculator like the other 000565 / 001431_case* fixtures.

This closes the last untested branch of the cylinder/water chain: the
SAP 10.2 §4 cylinder storage loss (Table 2/2a/2b lines 51-55) + the
Table 3 PRIMARY circuit loss (59, uninsulated pipework + no stat) that
combi/immersion fixtures don't reach. All 11 SAP-result fields reconcile
to the U985 worksheet EXACTLY with no calculator change — SAP 57.2904
(=57), cost £911.1973, water 3929.7635 kWh — confirming the cylinder-loss
derivation is correct.

Summary mirrored to the tracked fixtures dir so the test doesn't depend
on the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:50:19 +00:00
..
addresses standardist Address 2026-05-22 10:13:32 +00:00
billing refactor(billing): relocate Bill Derivation to domain/billing/ (cross-stage) 2026-06-03 17:19:23 +00:00
epc move overlas to its own thing 2026-06-18 10:04:14 +00:00
epc_prediction sap calculator variaince changes 2026-06-18 10:22:21 +00:00
fuel_rates feat(fuel-rates): FuelRates snapshot + repository foundation (ADR-0014) 2026-06-02 09:29:07 +00:00
magicplan handle 50 rows in new template file 2026-06-10 16:18:46 +00:00
modelling fix(climate): compute EPC CO2/PE on the postcode demand cascade (SAP 10.2 Appendix U p.124) 2026-06-18 14:15:34 +00:00
property move overlas to its own thing 2026-06-18 10:04:14 +00:00
property_baseline feat(baseline): sap_code_to_fuel normalizes via the calculator's own helper 2026-06-05 18:59:25 +00:00
sap10_calculator test(worksheet): pin simulated case 52 — regular gas boiler + cylinder 2026-06-24 08:50:19 +00:00
tasks tests framework completed 2026-05-20 14:00:19 +00:00
__init__.py added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
test_building_geometry.py feat(modelling): floor Recommendation Generator + ground-floor-area geometry 2026-06-03 09:12:29 +00:00
test_postcode.py tests framework completed 2026-05-20 14:00:19 +00:00