Model/tests/domain/sap10_calculator
Khalim Conn-Kowlessar faf29942ba fix(secondary): apply Table 11 secondary when lodged via description only (§A.2.2)
`_secondary_fraction` keyed "has a secondary" off the integer
`secondary_heating_type` code. The gov-API path surfaces the secondary as a
DESCRIPTION instead (`secondary_heating.description`, e.g. "Portable electric
heaters (assumed)") and leaves the integer code None. So a gas/oil boiler
main (not in the §A.2.2 forced-secondary set) with an assumed portable-electric
secondary dropped the secondary entirely (sec_kWh=0), under-costing the
dwelling and over-rating its SAP.

Per RdSAP §A.2.2 / SAP 10.2 Table 11, a lodged secondary is costed at its
Table 11 fraction (cat-2 boiler = 0.10, billed at standard-rate electricity per
the §A.2.2 assumed portable-electric default). New
`_has_lodged_secondary_description` treats a real `secondary_heating.description`
as a lodged secondary; passed to `_secondary_fraction` at both call sites. The
description is authoritative — same lesson as floor_heat_loss / roof codes.
(Electric-storage mains were unaffected: they force the secondary already.)

Also adds the Table 11 fraction for main_heating_category=8 (electric underfloor,
"Integrated storage/direct-acting electric systems" = 0.10) — the strict-raise
surfaced this latent gap once cat-8 mains were routed through the lookup.

Eval: 909 computed, 0 raises, 46.9% -> 47.6% within 0.5 (+13 certs: 420 -> 433),
mean|err| 1.633 -> 1.586. 13 improved / 1 regressed (2610, a cat-10 room-heater
cert with an independent over-count). Bucket "Portable electric heaters"
median +2.73 -> ~0 on the gas/cat-2 subset (cat-7 storage was already correct).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-08 14:28:22 +00:00
..
climate Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
rdsap fix(secondary): apply Table 11 secondary when lodged via description only (§A.2.2) 2026-06-08 14:28:22 +00:00
validation Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
worksheet fix(floor): floor_heat_loss=3 → above partially heated space, U=0.7 (RdSAP §3.12) 2026-06-07 22:25:04 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_bre_worked_examples.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_calculator.py feat(calculator): thread per-end-use fuel codes + PV export onto SapResult 2026-06-05 18:59:24 +00:00
test_pcdb_etl.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_322_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_329_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_pcdb_table_362_lookup.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_postcode_weather.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_table_12a.py fix(tariff): Unknown meter + storage/CPSU main → off-peak (§12) 2026-06-06 19:02:34 +00:00
test_table_32.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00