Khalim Conn-Kowlessar fc68fb21f6 Slice S0380.70: Secondary heating CO2/PE via lodged fuel type (cohort cert 2102 closure)
Cohort-2 cert 2102 (House coal secondary) and cohort-1 cert 0300-2747
(mains-gas secondary) both exposed the same bug: cert_to_inputs
hardcoded `_STANDARD_ELECTRICITY_FUEL_CODE` for the secondary CO2 and
PE factors, ignoring the cert's lodged `secondary_fuel_type`. The
cost-side helper `_secondary_fuel_cost_gbp_per_kwh` already routes
through the lodged code; this slice mirrors it on the CO2 and PE side.

Per SAP 10.2 Table 12d (p.195) and Table 12e (p.196) header text:
  "Where electricity is the fuel used, the relevant set of factors in
  the table below should be used to calculate the monthly [CO2
  emissions / primary energy] instead the annual average factor given
  in Table 12."

→ electricity end-uses use the monthly Table 12d/12e cascade;
non-electric fuels (House coal, mains gas, wood logs, etc.) pass
through the annual Table 12 factor.

Per Appendix M Table 4a + the API mapper's `_api_secondary_fuel_type`
spec-fuel override (S0380.43), cert 2102's lodged API code 33
(electricity off-peak) is rewritten to Table 32 code 11 (House coal)
because `secondary_heating_type=631` "Open fire in grate" is
physically incompatible with an electric secondary fuel. The new
`_secondary_fuel_code` helper preserves Table 12 codes (House coal 11
stays 11) and translates raw gov-API codes via API_FUEL_TO_TABLE_12
(e.g. lodged API 29 → Table 12 30 "standard electricity") so the
Table 12d/12e monthly lookups resolve consistently across both mapper
output regimes.

Cert 2102 DEMAND-path residuals (vs lodged):
  PE  +20.36 → +0.20 kWh/m²   (lodged 228 integer-rounded)
  CO2 -0.79  → +0.005 t/yr    (lodged 4.1 integer-rounded)

Cert 0300-2747 DEMAND-path residuals (mains-gas secondary, fuel 26):
  PE  +8.28  → +0.93  kWh/m²
  CO2 -0.25  → +0.25  t/yr

Other 23 golden certs all use the electricity default and stay pin-
exact via the API→Table 12 translation in `_secondary_fuel_code`.

New helpers in cert_to_inputs.py:
- `_secondary_fuel_code(epc)` — resolves the cert's secondary fuel
  code through the dual API/Table-12 fallback that
  `co2_factor_kg_per_kwh` already uses.
- `_secondary_heating_co2_factor_kg_per_kwh(epc, secondary_monthly_kwh)`
  — Table 12d monthly for electric, Table 12 annual for non-electric.
- `_secondary_heating_primary_factor(epc, secondary_monthly_kwh)`
  — Table 12e monthly for electric, Table 12 annual for non-electric.

Four call sites replaced:
- `cert_to_inputs` `secondary_heating_co2_factor_kg_per_kwh` field
  (line ~3552)
- `cert_to_inputs` `secondary_heating_primary_factor` field (line
  ~3625)
- `environmental_section_from_cert` secondary CO2 §12 (line ~1863)
- `primary_energy_section_from_cert` secondary PE §13a (line ~1967)

Tests:
- `test_house_coal_secondary_routes_to_annual_table_12_co2_and_pe_factors`
  pins 0.395 / 1.064 (Table 12 code 11).
- `test_secondary_heating_with_lodged_type_but_no_fuel_defaults_to_electricity`
  pins monthly-weighted electricity factors > annual 0.136 / 1.501
  (§A.2.2 default still applies).
- `test_golden_fixtures.py`: cert 2102 + 0300-2747 pins updated to
  the new residuals; 57 other golden certs untouched.

Baseline: 542 pass + 9 expected `test_sap_result_pin[000565-*]`
cascade-gap fails. Pyright net-zero on every touched file.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-29 11:09:14 +00:00
..
addresses get rid of comments 2026-05-20 13:21:11 +00:00
sap10_calculator Slice S0380.70: Secondary heating CO2/PE via lodged fuel type (cohort cert 2102 closure) 2026-05-29 11:09:14 +00:00
sap10_ml Slice S0380.26: RdSAP10 §5.8 dry-lining adjustment on alt walls — closes cert 7700 -0.44 → +5e-5 2026-05-28 10:56:11 +00:00
tasks added postcode splitter rewrite to ddd 2026-05-19 16:35:09 +00:00
postcode.py get rid of comments 2026-05-20 13:21:11 +00:00