Model/backend/documents_parser/tests
Khalim Conn-Kowlessar d4d2b222fc feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume)
Wire the non-separated conservatory into the §3 heat-transmission +
§1 dimensions cascade per RdSAP 10 §6.1 (PDF p.49) + Table 25 (p.51):

  "The floor area and volume of a non-separated conservatory are added to
   the total floor area and volume of the dwelling. Its roof area is taken
   as its floor area divided by cos(20°), and wall area is taken as the
   product of its exposed perimeter and its height. ... The conservatory
   walls and roof are taken as fully glazed ... Glazed walls are taken as
   windows, glazed roof as rooflight."

New `worksheet/conservatory.py` derives the geometry:
  - height from the equivalent storey count (§6.1: 1 storey → ground-floor
    room height; 1½ → ground + 0.25 + 0.5×first; etc.);
  - glazed WALL → window (27) at Table 25 U (double 3.1 / single 4.8) with
    the §3.2 curtain resistance (R=0.04) → U_eff 2.758;
  - glazed ROOF → rooflight (27a) at Table 25 roof U (double 3.4 / single
    5.3) + curtain → U_eff 2.993;
  - FLOOR → (28a) via BS EN ISO 13370 as an uninsulated SOLID ground floor
    with 300 mm walls (§5.12, spec p.43), exposed perimeter = glazed
    perimeter → U 0.89;
  - glazed wall + roof + floor areas join (31)/(36); the fully-glazed
    structure walls/roof add nothing (the glazing IS the window/rooflight).

`dimensions_from_cert` adds the conservatory floor area to TFA (4) and
floor area × height to volume (5) (feeds ventilation (8)), without making
it a storey (avg storey height for §2 infiltration is unchanged).

Pinned against the simulated case-44 P960 §3 at abs=1e-4 — every line ref
EXACT: (4) 95.3800, (5) 257.1630, (27) 96.1169, (27a) 38.2201, (28a)
21.4164, (29a) 35.5852, (30) 7.4688, (31) 294.2900, (33) 207.3274,
(36) 23.5432. The remaining whole-dwelling SAP/CO2 gap is the §6 solar
gains, closed in the next slice. Worksheet harness stays 47/47 0-raised.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-16 15:59:26 +00:00
..
fixtures feat(conservatory): §6.1 fabric cascade (27/27a/28a + TFA/volume) 2026-06-16 15:59:26 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py Merge remote-tracking branch 'origin/main' into feature/per-cert-mapper-validation 2026-06-13 22:20:15 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_room_heater_worksheet_001431.py S0380.239: system-build walls take masonry structural infiltration (0.35) 2026-06-05 19:00:02 +00:00