<RdSAP-Report xsi:schemaLocation="https://epbr.digital.communities.gov.uk/xsd/rdsap RdSAP-Report.xsd" xmlns="https://epbr.digital.communities.gov.uk/xsd/rdsap" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<Schema-Version-Original>LIG-19.0</Schema-Version-Original>
<SAP-Version>9.94</SAP-Version>
<PCDF-Revision-Number>553</PCDF-Revision-Number>
<Previous-EPC-Check>
<Previous-EPC-Checked>Y</Previous-EPC-Checked>
<Previous-EPC-Exists>N</Previous-EPC-Exists>
</Previous-EPC-Check>
<ExternalDefinitions-Revision-Number>6.1</ExternalDefinitions-Revision-Number>
<Calculation-Software-Name>Quidos ACE</Calculation-Software-Name>
<Calculation-Software-Version>v94.0.2.1</Calculation-Software-Version>
<User-Interface-Name>iQ-Energy</User-Interface-Name>
<User-Interface-Version>V5.0.0.1</User-Interface-Version>
<Report-Header>
<RRN>2170-8802-3050-8106-0621</RRN>
<Inspection-Date>2025-02-20</Inspection-Date>
<Report-Type>2</Report-Type>
<Completion-Date>2025-02-24</Completion-Date>
<Registration-Date>2025-02-24</Registration-Date>
<Status>entered</Status>
<Language-Code>1</Language-Code>
<Tenure>2</Tenure>
<Transaction-Type>8</Transaction-Type>
<Property-Type>0</Property-Type>
<Energy-Assessor>
<Name>Tabeebudeen Ahamed</Name>
<Notify-Lodgement>Y</Notify-Lodgement>
<Contact-Address>
<Address-Line-1>Suite 2D Park Plaza </Address-Line-1>
<Address-Line-2>Hayes Way </Address-Line-2>
<Post-Town>Cannock </Post-Town>
<Postcode>WS12 2DB</Postcode>
</Contact-Address>
<Web-Site></Web-Site>
<E-Mail>Tabeeb.Ahamed@warmfrontteam.co.uk</E-Mail>
<Telephone>08000328322</Telephone>
<Company-Name>Retro Team Limited </Company-Name>
<Scheme-Name>Quidos</Scheme-Name>
<Scheme-Web-Site>www.quidos.co.uk</Scheme-Web-Site>
<Identification-Number>
<Certificate-Number>QUID211784</Certificate-Number>
</Identification-Number>
</Energy-Assessor>
<Property>
<Address>
<Address-Line-1>7 Botany Close</Address-Line-1>
<Post-Town>SHEERNESS</Post-Town>
<Postcode>ME12 1QZ</Postcode>
</Address>
<UPRN>UPRN-100061073886</UPRN>
</Property>
<Region-Code>14</Region-Code>
<Country-Code>EAW</Country-Code>
<Related-Party-Disclosure>
<Related-Party-Disclosure-Number>1</Related-Party-Disclosure-Number>
</Related-Party-Disclosure>
</Report-Header>
<Energy-Assessment>
<Property-Summary>
<Wall>
<Description language="1">Cavity wall, as built, no insulation (assumed)</Description>
<Energy-Efficiency-Rating>2</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>2</Environmental-Efficiency-Rating>
</Wall>
<Roof>
<Description language="1">Pitched, 75 mm loft insulation</Description>
<Energy-Efficiency-Rating>3</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>3</Environmental-Efficiency-Rating>
</Roof>
<Floor>
<Description language="1">Solid, no insulation (assumed)</Description>
<Energy-Efficiency-Rating>0</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>0</Environmental-Efficiency-Rating>
</Floor>
<Window>
<Description language="1">Fully double glazed</Description>
<Energy-Efficiency-Rating>3</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>3</Environmental-Efficiency-Rating>
</Window>
<Main-Heating>
<Description language="1">Boiler and radiators, mains gas</Description>
<Energy-Efficiency-Rating>4</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>4</Environmental-Efficiency-Rating>
</Main-Heating>
<Main-Heating-Controls>
<Description language="1">Programmer, room thermostat and TRVs</Description>
<Energy-Efficiency-Rating>4</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>4</Environmental-Efficiency-Rating>
</Main-Heating-Controls>
<Hot-Water>
<Description language="1">From main system</Description>
<Energy-Efficiency-Rating>4</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>4</Environmental-Efficiency-Rating>
</Hot-Water>
<Lighting>
<Description language="1">Low energy lighting in 40% of fixed outlets</Description>
<Energy-Efficiency-Rating>3</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>3</Environmental-Efficiency-Rating>
</Lighting>
<Secondary-Heating>
<Description language="1">None</Description>
<Energy-Efficiency-Rating>0</Energy-Efficiency-Rating>
<Environmental-Efficiency-Rating>0</Environmental-Efficiency-Rating>
</Secondary-Heating>
<Has-Hot-Water-Cylinder>true</Has-Hot-Water-Cylinder>
<Has-Heated-Separate-Conservatory>false</Has-Heated-Separate-Conservatory>
<Dwelling-Type language="1">Mid-terrace house</Dwelling-Type>
<Total-Floor-Area>76</Total-Floor-Area>
<Has-Fixed-Air-Conditioning>false</Has-Fixed-Air-Conditioning>
<Multiple-Glazed-Proportion>100</Multiple-Glazed-Proportion>
</Property-Summary>
<Energy-Use>
<Energy-Rating-Average>60</Energy-Rating-Average>
<Energy-Rating-Current>68</Energy-Rating-Current>
<Energy-Rating-Potential>87</Energy-Rating-Potential>
<Environmental-Impact-Current>66</Environmental-Impact-Current>
<Environmental-Impact-Potential>86</Environmental-Impact-Potential>
<Energy-Consumption-Current>210</Energy-Consumption-Current>
<Energy-Consumption-Potential>63</Energy-Consumption-Potential>
<CO2-Emissions-Current>2.8</CO2-Emissions-Current>
<CO2-Emissions-Potential>0.9</CO2-Emissions-Potential>
<CO2-Emissions-Current-Per-Floor-Area>37</CO2-Emissions-Current-Per-Floor-Area>
<Lighting-Cost-Current currency="GBP">136</Lighting-Cost-Current>
<Lighting-Cost-Potential currency="GBP">85</Lighting-Cost-Potential>
<Heating-Cost-Current currency="GBP">637</Heating-Cost-Current>
<Heating-Cost-Potential currency="GBP">492</Heating-Cost-Potential>
<Hot-Water-Cost-Current currency="GBP">196</Hot-Water-Cost-Current>
<Hot-Water-Cost-Potential currency="GBP">116</Hot-Water-Cost-Potential>
</Energy-Use>
<Suggested-Improvements>
<Improvement>
<Sequence>1</Sequence>
<Improvement-Category>5</Improvement-Category>
<Green-Deal-Category>3</Green-Deal-Category>
<Improvement-Type>A</Improvement-Type>
<Improvement-Details>
<Improvement-Number>5</Improvement-Number>
</Improvement-Details>
<Typical-Saving currency="GBP">34</Typical-Saving>
<Indicative-Cost>£100 - £350</Indicative-Cost>
<Energy-Performance-Rating>69</Energy-Performance-Rating>
<Environmental-Impact-Rating>67</Environmental-Impact-Rating>
</Improvement>
<Improvement>
<Sequence>2</Sequence>
<Improvement-Category>5</Improvement-Category>
<Green-Deal-Category>3</Green-Deal-Category>
<Improvement-Type>B</Improvement-Type>
<Improvement-Details>
<Improvement-Number>6</Improvement-Number>
</Improvement-Details>
<Typical-Saving currency="GBP">122</Typical-Saving>
<Indicative-Cost>£500 - £1,500</Indicative-Cost>
<Energy-Performance-Rating>73</Energy-Performance-Rating>
<Environmental-Impact-Rating>73</Environmental-Impact-Rating>
</Improvement>
<Improvement>
<Sequence>3</Sequence>
<Improvement-Category>5</Improvement-Category>
<Green-Deal-Category>1</Green-Deal-Category>
<Improvement-Type>E</Improvement-Type>
<Improvement-Details>
<Improvement-Number>35</Improvement-Number>
</Improvement-Details>
<Typical-Saving currency="GBP">46</Typical-Saving>
<Indicative-Cost>£30</Indicative-Cost>
<Energy-Performance-Rating>74</Energy-Performance-Rating>
<Environmental-Impact-Rating>74</Environmental-Impact-Rating>
</Improvement>
<Improvement>
<Sequence>4</Sequence>
<Improvement-Category>5</Improvement-Category>
<Green-Deal-Category>2</Green-Deal-Category>
<Improvement-Type>N</Improvement-Type>
<Improvement-Details>
<Improvement-Number>19</Improvement-Number>
</Improvement-Details>
<Typical-Saving currency="GBP">74</Typical-Saving>
<Indicative-Cost>£4,000 - £6,000</Indicative-Cost>
<Energy-Performance-Rating>76</Energy-Performance-Rating>
<Environmental-Impact-Rating>77</Environmental-Impact-Rating>
</Improvement>
<Improvement>
<Sequence>5</Sequence>
<Improvement-Category>5</Improvement-Category>
<Green-Deal-Category>3</Green-Deal-Category>
<Improvement-Type>U</Improvement-Type>
<Improvement-Details>
<Improvement-Number>34</Improvement-Number>
</Improvement-Details>
<Typical-Saving currency="GBP">521</Typical-Saving>
<Indicative-Cost>£3,500 - £5,500</Indicative-Cost>
<Energy-Performance-Rating>87</Energy-Performance-Rating>
<Environmental-Impact-Rating>86</Environmental-Impact-Rating>
</Improvement>
</Suggested-Improvements>
<Green-Deal-Package>
<Green-Deal-Improvement>
<Improvement-Type>A</Improvement-Type>
<Improvement-Number>5</Improvement-Number>
</Green-Deal-Improvement>
<Green-Deal-Improvement>
<Improvement-Type>B</Improvement-Type>
<Improvement-Number>6</Improvement-Number>
</Green-Deal-Improvement>
<Green-Deal-Improvement>
<Improvement-Type>U</Improvement-Type>
<Improvement-Number>34</Improvement-Number>
</Green-Deal-Improvement>
<Electricity-Saving currency="GBP">521</Electricity-Saving>
<Gas-Saving currency="GBP">156</Gas-Saving>
<Other-Fuel-Saving currency="GBP">0</Other-Fuel-Saving>
</Green-Deal-Package>
<Renewable-Heat-Incentive>
<Space-Heating-Existing-Dwelling>7283</Space-Heating-Existing-Dwelling>
<Impact-Of-Loft-Insulation>-519</Impact-Of-Loft-Insulation>
<Impact-Of-Cavity-Insulation>-1850</Impact-Of-Cavity-Insulation>
<Water-Heating>2778</Water-Heating>
</Renewable-Heat-Incentive>
<Addendum>
<Cavity-Fill-Recommended>true</Cavity-Fill-Recommended>
</Addendum>
</Energy-Assessment>
<SAP-Data>
<SAP-Property-Details>
<Property-Type>0</Property-Type>
<Built-Form>4</Built-Form>
<Extensions-Count>0</Extensions-Count>
<Multiple-Glazed-Proportion>100</Multiple-Glazed-Proportion>
<Multiple-Glazing-Type>3</Multiple-Glazing-Type>
<PVC-Window-Frames>true</PVC-Window-Frames>
<Glazing-Gap>16+</Glazing-Gap>
<Glazed-Area>1</Glazed-Area>
<Door-Count>2</Door-Count>
<Insulated-Door-Count>0</Insulated-Door-Count>
<Percent-Draughtproofed>100</Percent-Draughtproofed>
<Habitable-Room-Count>4</Habitable-Room-Count>
<Heated-Room-Count>4</Heated-Room-Count>
<Fixed-Lighting-Outlets-Count>10</Fixed-Lighting-Outlets-Count>
<Low-Energy-Fixed-Lighting-Outlets-Count>4</Low-Energy-Fixed-Lighting-Outlets-Count>
<Low-Energy-Lighting>40</Low-Energy-Lighting>
<Measurement-Type>1</Measurement-Type>
<Mechanical-Ventilation>0</Mechanical-Ventilation>
<Open-Fireplaces-Count>0</Open-Fireplaces-Count>
<Solar-Water-Heating>N</Solar-Water-Heating>
<Conservatory-Type>1</Conservatory-Type>
<SAP-Building-Parts>
<SAP-Building-Part>
<Building-Part-Number>1</Building-Part-Number>
<Identifier>Main Dwelling</Identifier>
<Construction-Age-Band>H</Construction-Age-Band>
<SAP-Floor-Dimensions>
<SAP-Floor-Dimension>
<Floor>0</Floor>
<Floor-Construction>1</Floor-Construction>
<Floor-Insulation>1</Floor-Insulation>
<Heat-Loss-Perimeter quantity="metres">10.92</Heat-Loss-Perimeter>
<Party-Wall-Length quantity="metres">14</Party-Wall-Length>
<Total-Floor-Area quantity="square metres">38.22</Total-Floor-Area>
<Room-Height quantity="metres">2.42</Room-Height>
</SAP-Floor-Dimension>
<SAP-Floor-Dimension>
<Floor>1</Floor>
<Heat-Loss-Perimeter quantity="metres">10.92</Heat-Loss-Perimeter>
<Party-Wall-Length quantity="metres">14</Party-Wall-Length>
<Total-Floor-Area quantity="square metres">38.22</Total-Floor-Area>
<Room-Height quantity="metres">2.42</Room-Height>
</SAP-Floor-Dimension>
</SAP-Floor-Dimensions>
<Floor-Heat-Loss>7</Floor-Heat-Loss>
<Roof-Construction>4</Roof-Construction>
<Roof-Insulation-Location>2</Roof-Insulation-Location>
<Roof-Insulation-Thickness>75mm</Roof-Insulation-Thickness>
<Wall-Construction>4</Wall-Construction>
<Wall-Insulation-Type>4</Wall-Insulation-Type>
<Wall-Thickness-Measured>Y</Wall-Thickness-Measured>
<Wall-Thickness>300</Wall-Thickness>
<Wall-Dry-Lined>N</Wall-Dry-Lined>
<Wall-U-Value>1.51</Wall-U-Value>
<Party-Wall-Construction>0</Party-Wall-Construction>
</SAP-Building-Part>
</SAP-Building-Parts>
<SAP-Heating>
<Main-Heating-Details>
<Main-Heating>
<Main-Heating-Number>1</Main-Heating-Number>
<Main-Heating-Category>2</Main-Heating-Category>
<Main-Fuel-Type>26</Main-Fuel-Type>
<Main-Heating-Control>2106</Main-Heating-Control>
<Main-Heating-Data-Source>1</Main-Heating-Data-Source>
<Main-Heating-Index-Number>010310</Main-Heating-Index-Number>
<Boiler-Flue-Type>2</Boiler-Flue-Type>
<Fan-Flue-Present>Y</Fan-Flue-Present>
<Heat-Emitter-Type>1</Heat-Emitter-Type>
<Main-Heating-Fraction>1</Main-Heating-Fraction>
<Has-FGHRS>N</Has-FGHRS>
<Emitter-Temperature>0</Emitter-Temperature>
<MCS-Installed-Heat-Pump>false</MCS-Installed-Heat-Pump>
<Central-Heating-Pump-Age>0</Central-Heating-Pump-Age>
</Main-Heating>
</Main-Heating-Details>
<Water-Heating-Code>901</Water-Heating-Code>
<Water-Heating-Fuel>26</Water-Heating-Fuel>
<Immersion-Heating-Type>NA</Immersion-Heating-Type>
<Cylinder-Size>2</Cylinder-Size>
<Cylinder-Insulation-Type>1</Cylinder-Insulation-Type>
<Cylinder-Insulation-Thickness>25</Cylinder-Insulation-Thickness>
<Cylinder-Thermostat>Y</Cylinder-Thermostat>
<Has-Fixed-Air-Conditioning>false</Has-Fixed-Air-Conditioning>
<Instantaneous-WWHRS>
<Rooms-With-Bath-And-Or-Shower>1</Rooms-With-Bath-And-Or-Shower>
<Rooms-With-Mixer-Shower-No-Bath>1</Rooms-With-Mixer-Shower-No-Bath>
<Rooms-With-Bath-And-Mixer-Shower>0</Rooms-With-Bath-And-Mixer-Shower>
</Instantaneous-WWHRS>
</SAP-Heating>
<SAP-Energy-Source>
<Meter-Type>2</Meter-Type>
<Mains-Gas>Y</Mains-Gas>
<Wind-Turbines-Count>0</Wind-Turbines-Count>
<Wind-Turbines-Terrain-Type>2</Wind-Turbines-Terrain-Type>
<Photovoltaic-Supply>
<None-Or-No-Details>
<Percent-Roof-Area>0</Percent-Roof-Area>
<PV-Connection>0</PV-Connection>
</None-Or-No-Details>
</Photovoltaic-Supply>
</SAP-Energy-Source>
</SAP-Property-Details>
</SAP-Data>
<Insurance-Details>
<Insurer>Tokio Marine HCC</Insurer>
<Policy-No>PI24H761712</Policy-No>
<Effective-Date>2024-08-02</Effective-Date>
<Expiry-Date>2025-08-01</Expiry-Date>
<PI-Limit>500000</PI-Limit>
</Insurance-Details>
</RdSAP-Report>