mirror of
https://github.com/Hestia-Homes/Model.git
synced 2026-07-12 13:29:04 +00:00
minor
This commit is contained in:
parent
5dc78d6bb9
commit
b75ae5f6b8
1 changed files with 103 additions and 19 deletions
|
|
@ -102,8 +102,6 @@ def main():
|
||||||
# TODO
|
# TODO
|
||||||
# - AIH001-03 has a loft that is inaccessible - ask Chenai about why this property didn't have access to the loft
|
# - AIH001-03 has a loft that is inaccessible - ask Chenai about why this property didn't have access to the loft
|
||||||
# [Can't remember, not clear - Chenai will check]
|
# [Can't remember, not clear - Chenai will check]
|
||||||
# - AIH001-04 why couldn't the cylinder be accessed? - treating this could get to the EPC C
|
|
||||||
# - Potential measure - search for the cylinder and insulate it
|
|
||||||
# - AIH001-08 and AIH001-09, check if it's freehold - could solar work as both of these units are part of the same
|
# - AIH001-08 and AIH001-09, check if it's freehold - could solar work as both of these units are part of the same
|
||||||
# buulding [Question for Lewis & Kevin]
|
# buulding [Question for Lewis & Kevin]
|
||||||
# - AIH001-09 - Is it not possible to install a loft hatch? [IT IS NOT, NO ACCESS - would need to accessed from
|
# - AIH001-09 - Is it not possible to install a loft hatch? [IT IS NOT, NO ACCESS - would need to accessed from
|
||||||
|
|
@ -111,9 +109,9 @@ def main():
|
||||||
# - AIH001-09 - Is there definitely an immersion water heater? Is this definitely the case for the other units?
|
# - AIH001-09 - Is there definitely an immersion water heater? Is this definitely the case for the other units?
|
||||||
# [Question for Lewis & Kevin] - [YES - ASHP!!!!]
|
# [Question for Lewis & Kevin] - [YES - ASHP!!!!]
|
||||||
|
|
||||||
# TODO: Need AIH001-02 9C Clapton Common
|
|
||||||
# TODO: Check which properties are in a conservation area
|
# TODO: Check which properties are in a conservation area
|
||||||
# TODO: AIH001-16 - Is the loft insulation suitable (already has 100mm in the RIR)
|
# TODO: AIH001-16 - Is the loft insulation suitable (already has 100mm in the RIR)
|
||||||
|
# TODO: Adjust Archetype 14 homes to exclude double glazing? Or should we exclude entirely
|
||||||
|
|
||||||
recommended_measures = [
|
recommended_measures = [
|
||||||
{
|
{
|
||||||
|
|
@ -376,6 +374,8 @@ def main():
|
||||||
"floor_area": 63.59 + 12.31, # Based on area of main building and 1st extension
|
"floor_area": 63.59 + 12.31, # Based on area of main building and 1st extension
|
||||||
"sap_points": 8,
|
"sap_points": 8,
|
||||||
"ending_sap": 70,
|
"ending_sap": 70,
|
||||||
|
"notes": "Loft is inaccessible from this unit - would need to be accessed from the other unit, "
|
||||||
|
"which is also owned by AIHA"
|
||||||
}
|
}
|
||||||
],
|
],
|
||||||
"notes": "This property is a house split into 2 flats. We can install a PV array for both units (one array"
|
"notes": "This property is a house split into 2 flats. We can install a PV array for both units (one array"
|
||||||
|
|
@ -419,31 +419,31 @@ def main():
|
||||||
"sap_points": 3,
|
"sap_points": 3,
|
||||||
"ending_sap": 49,
|
"ending_sap": 49,
|
||||||
},
|
},
|
||||||
{
|
# {
|
||||||
"measure": "Solar PV",
|
# "measure": "Solar PV",
|
||||||
"description": "3.2kWp Solar PV system",
|
# "description": "3.2kWp Solar PV system",
|
||||||
"config": [
|
# "config": [
|
||||||
{
|
# {
|
||||||
"size": "3.2W",
|
# "size": "3.2W",
|
||||||
"orientation": "East",
|
# "orientation": "East",
|
||||||
"elavation": 30,
|
# "elavation": 30,
|
||||||
"overshading": "Little or none",
|
# "overshading": "Little or none",
|
||||||
}
|
# }
|
||||||
],
|
# ],
|
||||||
"sap_points": 9,
|
# "sap_points": 9,
|
||||||
"ending_sap": 58
|
# "ending_sap": 58
|
||||||
},
|
# },
|
||||||
{
|
{
|
||||||
"measure": "Air Source Heat Pump",
|
"measure": "Air Source Heat Pump",
|
||||||
"description": "Ecoforest ecoAIR EVI 4-20 20kW air source heat pump (+TTZC)",
|
"description": "Ecoforest ecoAIR EVI 4-20 20kW air source heat pump (+TTZC)",
|
||||||
"sap_points": 15,
|
"sap_points": 15,
|
||||||
"ending_sap": 73
|
"ending_sap": 65
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
"measure": "Tariff Review",
|
"measure": "Tariff Review",
|
||||||
"description": "Switch to 24-hour tariff",
|
"description": "Switch to 24-hour tariff",
|
||||||
"sap_points": 15,
|
"sap_points": 15,
|
||||||
"ending_sap": 88
|
"ending_sap": 80
|
||||||
}
|
}
|
||||||
]
|
]
|
||||||
},
|
},
|
||||||
|
|
@ -740,6 +740,90 @@ def main():
|
||||||
"ending_sap": 74,
|
"ending_sap": 74,
|
||||||
}
|
}
|
||||||
]
|
]
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"survey_key": "AIH001-SIMULATED-01",
|
||||||
|
"elmhurst_reference": "000020",
|
||||||
|
"starting_sap": None,
|
||||||
|
"recommended_measures": [
|
||||||
|
{
|
||||||
|
"measure": "Internal Wall Insulation",
|
||||||
|
"description": "100mm internal wall insulation",
|
||||||
|
"hlp": (22.35 * 3.24) + (22.13 * 2.53),
|
||||||
|
"sap_points": 8,
|
||||||
|
"ending_sap": 52,
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "Cavity Wall Insulation",
|
||||||
|
"description": "CWI to rdSAP default standard",
|
||||||
|
"hlp": (2.68 * 2.39) + (5.93 * 2.63) + (6.13 * 2.39), # 1st & 2nd extension
|
||||||
|
"sap_points": 1,
|
||||||
|
"ending_sap": 53,
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "Ventilation",
|
||||||
|
"description": "2x DMEV fans",
|
||||||
|
"sap_points": 0,
|
||||||
|
"ending_sap": 53,
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "TTZC",
|
||||||
|
"description": "Smart Thermostat",
|
||||||
|
"sap_points": 3,
|
||||||
|
"ending_sap": 56,
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "Solar PV",
|
||||||
|
"description": "1.6kWp Solar PV system",
|
||||||
|
"config": [
|
||||||
|
{
|
||||||
|
"size": "1.6W",
|
||||||
|
"orientation": "South-East",
|
||||||
|
"elavation": 30,
|
||||||
|
"overshading": "None or little",
|
||||||
|
}
|
||||||
|
],
|
||||||
|
"sap_points": 6,
|
||||||
|
"ending_sap": 62
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "Loft Insulation",
|
||||||
|
"description": "300mm loft insulation",
|
||||||
|
"floor_area": 63.59 + 12.31, # Based on area of main building and 1st extension
|
||||||
|
"sap_points": 8,
|
||||||
|
"ending_sap": 70,
|
||||||
|
"notes": "Loft is inaccessible from this unit - would need to be accessed from the other unit, "
|
||||||
|
"which is also owned by AIHA"
|
||||||
|
}
|
||||||
|
],
|
||||||
|
"notes": "This was cloned from 80A. There is no existing data for 80B"
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"survey_key": "AIH001-SIMULATED-05",
|
||||||
|
"starting_sap": 68,
|
||||||
|
"recommended_measures": [
|
||||||
|
{
|
||||||
|
"measure": "Loft Insulation",
|
||||||
|
"description": "300mm loft insulation",
|
||||||
|
"floor_area": 42.5,
|
||||||
|
"sap_points": 1,
|
||||||
|
"ending_sap": 69,
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"measure": "Solar PV",
|
||||||
|
"description": "3.2kWp Solar PV system",
|
||||||
|
"config": [
|
||||||
|
{
|
||||||
|
"size": "3.2W",
|
||||||
|
"orientation": "North-East",
|
||||||
|
"elavation": 30,
|
||||||
|
"overshading": "None or little",
|
||||||
|
}
|
||||||
|
],
|
||||||
|
"sap_points": 8,
|
||||||
|
"ending_sap": 77,
|
||||||
|
}
|
||||||
|
]
|
||||||
}
|
}
|
||||||
]
|
]
|
||||||
|
|
||||||
|
|
|
||||||
Loading…
Add table
Reference in a new issue