The deal's third_party_surveyor_identifier is now required by the log
and amend flows: the trigger contract rejects messages without it
(blank treated as missing, since a blank resource makes OpenHousing
silently drop the appointment), and LogJobRequest/AmendJobRequest carry
it as a required field. The ABRI_RELAY_DEFAULT_RESOURCE fallback and
its config/terraform/workflow wiring are removed as dead code.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Carry third_party_surveyor_identifier on the Abri trigger message and
through dispatch into the log and amend flows, booking the job against
that resource. LogJobRequest gains the optional resource field
AmendJobRequest already had; the client falls back to the configured
default surveyor when the deal names no third-party resource, so
existing deals behave unchanged.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Fetch the property from the HubSpot deals API, persist it on
hubspot_deal_data (column added by the frontend repo's drizzle
migration), and include it in the differ's FIELD_MAP so a change
to the field triggers a DB reload.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
A mid-terrace / enclosed-mid-terrace (built_form 4/6) has external walls on
its two opposite (front/rear) faces only (RdSAP 10 §1.1, p.7-8); both end/
gable elevations — and their room-in-roof continuations — abut a neighbour
and are party walls (§1.4.3, p.9). The gov-API path is built_form-blind, so a
cert lodging an "Exposed" RR gable (`gable_wall_type=1`) on such a form had it
billed at the masonry main-wall U (~2.5) instead of the party 0.25 (Table 4,
p.22), over-counting fabric heat loss and under-rating the dwelling.
`_api_type_1_gable_kind` now takes `built_form` and reclassifies an Exposed RR
gable to Party on the both-ends-party forms {4, 6} only; end-terrace {3, 5},
semi {2} and detached {1} keep their genuine exposed gable. The API path lodges
no per-gable U, so this only ever overrides a cascade fallback.
Corroborated three ways: RdSAP §1.1 + Table 4; S10TP-05 Appendix A (a
mid-terrace's roof-gable junction length is zero); and three accredited
Elmhurst mid-terrace worksheets (000477/000480/000516), which all lodge Party
gables. Those worksheets run the site-notes path (already correct) so the 195
Elmhurst pins are untouched.
Corpus (RdSAP-21.0.1, 1000 certs): within-0.5 78.8% -> 79.5%, SAP MAE
0.625 -> 0.599, PE MAE 2.85 -> 2.71, CO2 MAE 0.070 -> 0.068. Cert
100040550095 -10.13 -> +0.37; the 18-cert terraced-external-gable cohort mean
-1.94 -> +0.11; end-terrace/semi/detached untouched. Thresholds ratcheted.
Tests: new test_mapper_rir_gable_terraced (9); 195 Elmhurst pins, 288
cert_to_inputs/real-cert pins, 54 mapper tests, and the corpus gauge all green;
no new pyright errors.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
When DHW is supplied by a community heat network (WHC 901/902/914 on a
heat-network main), the network heat -- space AND water -- bills at the main's
Table-12 heat-network rate. The STANDARD-tariff §10a cost path (_fuel_cost)
re-derived the DHW rate inline from the cert-lodged HW fuel, which Elmhurst
defaults to 'Mains gas' (Table 32 code 26, 3.48 p/kWh) on community certs --
under-costing DHW and over-rating SAP. Now inherits the main heat-network rate
via _fuel_cost_gbp_per_kwh, mirroring the .173 inherit already applied on the
legacy/off-peak HW-rate paths. Scoped to community heating, so all other certs
are unchanged; the RdSAP-21.0.1 corpus gauge improves 78.6%->78.9% within-0.5
(MAE 0.628->0.622) with all 195 Elmhurst worksheet pins green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
#1631: the label blocks in the main room-heater type table (Heating
System (Other) field), not the secondary table the issue cited — same
PCDB row either way. Wythenshawe 164→165 computed. The fixture scores
49.5 vs pre_sap 31: its own 2025 accredited cert
6890-0597-0722-0196-3943 lodges the identical codes (603/26/2601) at
band E agreeing with us, while pre_sap matches the dwelling's
superseded electric configuration (2017/2023 certs, band F) — accepted
divergence, MAE ceiling re-baselined 0.75→0.85 with the citation.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1628: fixture 500796700868 re-blocks on a later label
(first-exception-hit); metrics unchanged, ratchets hold.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Follow-on surfaced by #1626: fixture 500796646644 progressed past the
2404 conflict onto cylinder insulation 'Loose jacket' → code 2 (gov-API
coding, Elmhurst 'Jacket' sibling). Wythenshawe 161→162 computed
(32.6 vs pre 34); ratchets hold at 75.3%/0.744.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1626: ground truth resolved per the issue's option 3. The accredited
cert 0764-2894-7173-2720-5535 (62 Mayfair Road, UPRN 77066640 — the
blocked Wythenshawe fixture's dwelling) lodges 402 + 2402 for the same
heater description, and RdSAP 10 p.80 (item 7-3) requires a PCDB index
for any HHR lodgement — absent one, the surveyed type field is
authoritative and 2404 downgrades to 2402 (automatic charge control,
preserving the tick's automatic-charging semantics). Applies only to
the mapped non-HHR types (402/404); any other pairing still fails loud.
LRHA fixture 505091686590 (Fan storage heater, same slip) computes
64.0 vs pre 65; LRHA 76→77 computed.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1625: 'Same dwelling below' → the "(another dwelling below)" party-
floor suppression string, mirroring the gov-API code-8 precedent
(RdSAP 10 §3: an internal floor between heated storeys has no floor
heat loss). Wythenshawe 151→161 computed; 7/10 newly-unblocked land
within 0.5 — ratchets re-baselined 0.76/0.72 → 0.75/0.75 for the two
tail entries (−3.3/−5.5).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1624: Wythenshawe 149→151 computed. 500767954156 lands within 0.5;
500797465814 is a −8.8 tail entry — MAE ceiling re-baselined 0.67→0.72
per the coverage-growth convention (within-0.5 floor 0.76 holds).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1637: 'MV - Heat Recovery' → MVHR kind (Table 4g default 46.2% heat
recovery — PasHub lodges no PCDF product/wet-rooms/duct data, so these
land in the accuracy tail as the issue predicts). Unblocking them
surfaced 4 biomass heat networks whose fuel label 'Heat from boilers -
biomass' passed through raw to the calculator's MissingMainFuelType —
now mapped to Table 12 code 43, and any other uncovered community fuel
strict-raises UnmappedPasHubLabel at the boundary (ADR-0015).
LRHA 61→76 computed / 28 blocked / 0 errored, within-0.5 43.4%,
MAE 2.985 — ratchets hold.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1636: the 6 single-line-label fixtures unblock and re-block on later
labels (MVHR/cylinder); the 6 line-wrap-truncated '…room thermostat
and' fixtures still need the extractor fix tracked under #1622.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
#1635: 'Programmer, room thermostat and TRVs' on a heat pump → 2210
(PCDB heat_pump_controls), and the lodgement now carries Table 4a
category 4 — without it the calculator's Appendix N3.6/N3.7 gate never
fired and the PCDB heat pump was billed as 100%-efficient direct
electric (6.0/18.5 vs pre 62/57). With the category threaded the two
LRHA WAVE 3 fixtures score 52.1/56.9 (the latter within 0.5).
LRHA 59→61 computed, within-0.5 42.6%, MAE 2.830 — ratchets hold.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
One-time ingest of Wythenshawe Community Housing Group Elmhurst *Summary*
PDFs: resolve each property's SharePoint folder from the WCHG xlsx, download
the summary, run the existing extractor -> mapper -> SAP10 pipeline, and
(with --commit) push the PDF to S3, record an uploaded_files row, and save
the EpcPropertyData to epc_property keyed on the national UPRN (property_id
NULL, replace-by-(uprn,source)). Dry-run by default; also emits a SAP-accuracy
CSV vs Elmhurst's reported current SAP (% within 0.5 + MAE).
Adds DomnaSites.SOCIAL_HOUSING (SOCIAL_HOUSING_SHAREPOINT_ID) for the site.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Positive input ventilation sourced from the loft is treated as natural
ventilation under SAP 10.2 §2 (24d) — matching the MechanicalVentilationKind
.NATURAL contract — so the label now resolves instead of raising
UnmappedElmhurstLabel and blocking the whole Elmhurst Summary. Surfaced on
8 WCHG Elmhurst certs (e.g. 29 Piper Hill Avenue, 38 Bucklow Drive).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add pashub_accuracy_wythenshawe fixtures + a sibling accuracy module,
built from project_code
[Wythenshawe WH:SHF RAs - WH:SF - 240426 - 494493718748] the same way as
LRHA WAVE 3 (#1620). First run: 149 computed / 19 blocked / 0 errored,
within-0.5 76.5%, MAE 0.665. Ratchets baselined to this cohort; the 19
blocks are separately-ticketed mapper-label gaps (floor 'Same dwelling
below' ×10 dominating), not tuning.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>