Khalim Conn-Kowlessar
0c70280dea guard(modelling_e2e): quarantine predicted Properties the calculator mis-scores
TEMPORARY guard (remove once the SAP calculator's oil-heating under-score is
fixed): a predicted oil-boiler picture scores SAP 13/G against its own
synthesised recorded SAP of 50/E, so the optimiser overshoots goal C all the
way to band A and publishes nonsense.

A predicted EpcPropertyData carries its recorded SAP (energy_rating_current).
When the calculator baseline diverges from it by more than ~one band (20 SAP
points), withhold the Plan: raise inside the per-property loop so the existing
failure isolation drops just that property into `failures` and fails the
subtask, while every other property still models and persists. Lodged
Properties are untouched — they have a real recorded cert and the Rebaseliner
already owns this check.

Verified end-to-end against property 713406 (UPRN 100061849247): baseline 13.2
vs recorded 50 -> quarantined, no Plan written.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:24 +00:00
Khalim Conn-Kowlessar
01bc93ed33 Merge remote-tracking branch 'origin/main' into feature/e2e-runs 2026-06-24 08:39:31 +00:00
Khalim Conn-Kowlessar
7a970ea393 fix(repositories): fold landlord overrides when re-hydrating a Property via the UoW
PostgresUnitOfWork built its PropertyPostgresRepository without an overrides
reader, so a Property re-hydrated through the unit silently dropped its
Landlord Overrides (ADR-0032). The Baseline orchestrator runs through the UoW,
so it scored the bare lodged EPC while the Plan modelled the override-folded
Effective EPC — the two diverged (e.g. baseline effective 71/C vs plan
baseline 62/D), producing "already at band C yet recommends reaching C".

Wire PropertyOverridesPostgresReader into the unit's property repo (uow-
independent committed reference data, read via the same session factory) so
every re-hydration folds overrides, matching the live modelling path.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:34:30 +00:00
KhalimCK
bf52eb1fcc
Merge pull request #1187 from Hestia-Homes/investigate/glazing-draughtproofing
modelling: glazing overlay models draught-proofing + frame-factor re-lodge
2026-06-24 09:32:29 +01:00
Khalim Conn-Kowlessar
80d617aa5b modelling: glazing overlay models draught-proofing + frame-factor re-lodge
Fitting sealed glazing units changes two things beyond the pane's U/g
that the cascade reads, which the overlay didn't model — leaving the
double/secondary before→after pins ~0.7 SAP short (xfail):

1. Draught-proofing (RdSAP 10 §8.1). Sealed units draught-proof the panes
   they replace, re-lodging the dwelling-level `percent_draughtproofed`
   (cert 001431: 84 → 100). The §2 cascade reads that dwelling-level
   value, so the overlay now carries it. `_recompute_percent_draughtproofed`
   anchors on the lodged before-% — `after = round((round(before%/100 × N)
   + flips) / N × 100)`, N = openable windows (vertical + roof) + doors,
   flips = upgraded panes that were not draught-proofed — so it's robust
   to incomplete window extraction (unchanged openings are already in the
   aggregate). ~0.3 SAP.

2. Frame factor (§6 solar gains). A replacement unit re-lodges its own
   FF=0.70, overriding the pane it replaced — the two "single glazing,
   known data" panes lodge FF 1.00 / 0.50 (one is 6.6 m²), so leaving them
   unchanged understated solar gains by ~+150 kWh space heating. `WindowOverlay`
   now carries `frame_factor`, written flat onto the window. ~0.4 SAP.

Wiring: `EpcSimulation.percent_draughtproofed` + `WindowOverlay.frame_factor`
new fields; `apply_simulations` / `_fold_window` write them; the glazing
generator computes both from the upgraded set and cert 001431's after.

Un-xfails `test_{double,secondary}_glazing_overlay_reproduces_the_relodged_after`
— both now pin SAP/CO2/PE to the relodged after within tolerance. Updates
the two `test_glazing_recommendation` overlay expectations for the new
`frame_factor`. 96 modelling tests pass; zero new pyright errors.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-24 08:25:08 +00:00
Jun-te Kim
22cb47a280
Merge pull request #1285 from Hestia-Homes/feature/e2e-runs
fix(modelling_e2e): persist predicted EPC + baseline for predicted pr…
2026-06-24 09:08:06 +01:00
Jun-te Kim
4a1160a4b3
Merge pull request #1284 from Hestia-Homes/fix/wet-rooms-count-not-null
Default RdSAP 21.0.1 wet_rooms_count to 0 (fix NOT-NULL violation, 37 e2e failures)
2026-06-24 09:07:49 +01:00
Jun-te Kim
c49682658a ci: disable integration/deploy/protect workflows (Actions minutes)
Comment out the remaining workflows to cut GitHub Actions usage, per request:
- integration_tests.yml — rebaselining integration suite (PRs to main)
- deploy_fastapi_backend.yml — FastAPI backend deploy (push to dev/prod);
  deploys must be run manually via `sls deploy` while disabled
- protect_releases.yml — main→dev PR-source guardrail

Fully commented (not deleted) so each restores by uncommenting.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 07:56:42 +00:00
Jun-te Kim
f2ace566c3 ci: disable unit_tests.yml workflow (Actions minutes)
Comment out the Docker-based unit-test workflow — it was consuming too many
GitHub Actions minutes. Fully commented (rather than deleted) so it can be
restored by uncommenting.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 07:54:07 +00:00
Jun-te Kim
4fe59b8e78 Default RdSAP 21.0.1 wet_rooms_count to 0 (fix NOT-NULL violation)
37 modelling_e2e properties failed on the 2026-06-23 run with
`NotNullViolation: null value in column "wet_rooms_count" of relation
"epc_property"`.

Root cause: 21.0.1 lodges `wet_rooms_count` as Optional, and
`from_rdsap_schema_21_0_1` passed it straight through
(`wet_rooms_count=schema.wet_rooms_count`). A cert omitting it mapped to
`EpcPropertyData.wet_rooms_count=None`. When a predicted EPC (which deep-copies
a comparable template's EpcPropertyData) inherited that None and was persisted,
it violated the `epc_property.wet_rooms_count` NOT-NULL column — and the calc's
`wet_rooms_count > 0` check would also raise `TypeError` on None.

Fix: coalesce to 0, matching every other mapper (RdSAP "not lodged" → the
calc's minimum 1 wet room). Regression test added.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 07:42:34 +00:00
Jun-te Kim
09ec985f98
Merge pull request #1280 from Hestia-Homes/feature/modelling-e2e-failure-logs
Mark unmappable cohort certs as a modelling_e2e subtask failure
2026-06-23 19:38:36 +01:00
Jun-te Kim
52963c4745
Merge pull request #1281 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
Feature/hyde make it more accurate with tests
2026-06-23 19:38:24 +01:00
Jun-te Kim
390da1e491 resolve merge conflicts 2026-06-23 18:09:09 +00:00
Jun-te Kim
51118ce121 solar + more logs 2026-06-23 18:07:10 +00:00
Jun-te Kim
af5b2b5f80 Mark unmappable cohort certs as a subtask failure
Skipped cohort certs were previously surfaced only as outputs.result on a
completed subtask, so they were easy to miss. Treat them as a failure too:
once the batch has run to completion (so every modellable property is already
written to DB), raise if there were any per-property errors OR any skipped
certs. The run gets flagged for debugging without discarding the work done.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 18:03:04 +00:00
Jun-te Kim
826aaf900b
Merge pull request #1278 from Hestia-Homes/feature/modelling-e2e-failure-logs
Record per-property failure detail in modelling_e2e subtask outputs
2026-06-23 18:54:27 +01:00
Jun-te Kim
290097b1c7 Record per-property failure detail in modelling_e2e subtask outputs
When a property failed, the handler recorded only its bare property_id and
raised RuntimeError("failed property_ids: [...]"). That string is what
SubTask.fail persists into the subtask outputs.error column, so a failed run
told you which property failed but never why — forcing a CloudWatch lookup.

The per-property catch now captures property_id, uprn, error_type, and the
error message, and the raised RuntimeError embeds those as JSON so the subtask
outputs column is parseable directly. query_failed_modelling_e2e.py reads that
outputs.error into a new Error column in its report.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:53:43 +00:00
Khalim Conn-Kowlessar
e80be44fd1 fix(modelling_e2e): persist predicted EPC + baseline for predicted properties
A predicted Property (no lodged EPC) got a Plan but nothing else: the synthesised
EPC was never written to epc_property, and Baseline Performance was skipped — so
property 729529 (portfolio 796 / scenario 1268), predicted from its DA16 1QZ
cohort, was "missed" with no predicted-EPC row and no baseline row.

Persist the synthesised EPC in the predicted slot (uow.epc.save(..., source=
"predicted"), ADR-0031) inside the Plan UoW, then run the Baseline orchestrator
for predicted Properties too — it re-hydrates the predicted EPC and establishes
the baseline from it. The earlier "lodged only" guard is dropped: by the write
block the Property always has a persisted EPC (lodged or predicted); one that
could be neither fetched nor predicted raised earlier.

Verified against the DB by invoking the real handler for 729529: predicted
epc_property rows 0->1 and property_baseline_performance rows 0->1. Baseline on
the predicted picture builds cleanly (RHI present, reason pre_sap10). Tests
updated: prediction + broadening paths now assert the predicted-slot epc.save and
the baseline run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:49:08 +00:00
Jun-te Kim
6f0e526d3d
Merge pull request #1276 from Hestia-Homes/feature/e2e-runs
Feature/e2e runs
2026-06-23 18:24:41 +01:00
Khalim Conn-Kowlessar
2ee1b35dca fix(modelling_e2e): persist Baseline Performance for lodged properties
The handler wrote epc/spatial/solar/plan and marked the property modelled, but
never established its Baseline Performance — so no row was created in
property_baseline_performance for any property modelled through the Lambda
(noticed on portfolio 796 / scenario 1268 / property 727218, a lodged property).

Mirror the e2e runner: after the plan UoW commits (so the EPC is persisted for
the orchestrator to re-hydrate), run PropertyBaselineOrchestrator for lodged
properties. Predicted properties have no lodged figures and no persisted EPC, so
they are skipped — consistent with the e2e runner and the ara_first_run Baseline
stage.

Verified 727218's baseline pipeline builds end-to-end in-memory (lodged_performance
→ CalculatorRebaseliner → bill → PropertyBaselinePerformance, reason pre_sap10).
Tests: lodged path asserts the orchestrator runs once; prediction path asserts it
does not.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:21:03 +00:00
Jun-te Kim
485ab220d1
Merge pull request #1270 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
Feature/hyde make it more accurate with tests
2026-06-23 18:15:24 +01:00
Jun-te Kim
e8c3406901 Update worklist: override now lands positionally, not skipped
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:09:47 +00:00
Jun-te Kim
9956df07ff Land an override on the EPC's part at its position when the label is absent 🟩
A Landlord Override's building_part is a positional index (0=main, 1=extension
1…, ADR-0004), but the gov-API EPC can label that slot differently (e.g. lodge
the 2nd part as 'other', not 'extension_1'). The previous fix skipped such
orphaned overrides, silently discarding the landlord's correction. Now the
override falls back onto the EPC's part at that position (via _resolve_part), so
the correction lands; only a position the EPC models no part at is skipped
(no geometry to model a wholly-absent part). Replaces the skip-only behaviour.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:09:11 +00:00
Khalim Conn-Kowlessar
4f4ec32e51 Merge remote-tracking branch 'origin/main' into feature/e2e-runs
# Conflicts:
#	repositories/comparable_properties/epc_comparable_properties_repository.py
#	tests/repositories/comparable_properties/test_epc_comparable_properties_repository.py
2026-06-23 17:07:27 +00:00
Khalim Conn-Kowlessar
de7fb94ff7 docs(adr): record nearby-postcode broadening (0034) + share HTTP retry primitive
Closes out the cohort-broadening work with its decision record and consolidates
the retry plumbing.

ADR-0034 documents broadening the EPC-Prediction cohort to the real unit
postcodes nearest the target (via postcodes.io) when its own postcode holds no
same-type comparable — extending ADR-0031 decision 5. Records why postcodes.io
was chosen over council[] (whole-LA, no property_type in rows), a bulk Code-Point
Open / ONSPD dataset, and the OS Places radius API, and the lazy / nearest-first
early-stop / soft-fail policy. Broadening-specific docstrings now cite 0034.

Retry consolidation: extract the EPC client's call_with_retry into a shared
infrastructure/http_retry.py keyed off a generic TransientHttpError marker, so
the mechanism (exponential backoff, Retry-After) is shared while each client
keeps its own transient policy. EpcRateLimitError now subclasses TransientHttpError
(still an EpcApiError); PostcodesIoClient routes through the same helper, raising
TransientHttpError on 429/5xx and soft-failing to the seed once exhausted (the EPC
client propagates instead). Direct tests for the shared helper; EPC + postcodes.io
suites repointed at the shared sleep.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:54:06 +00:00
Jun-te Kim
3f6f17bb85 fix merge conflicts 2026-06-23 16:51:06 +00:00
Jun-te Kim
0401797524 sap fixes 2026-06-23 16:48:04 +00:00
Daniel Roth
a76666926f
Merge pull request #1274 from Hestia-Homes/trigger-e2e-locally
Limit database connections using NullPool
2026-06-23 17:42:22 +01:00
Daniel Roth
93f6fbe1b9 revert pytest.ini 2026-06-23 16:39:49 +00:00
Daniel Roth
a4aaf0e81f Merge branch 'main' into trigger-e2e-locally 2026-06-23 16:38:03 +00:00
Daniel Roth
79a76b10a9 fix db issues 2026-06-23 16:36:59 +00:00
Khalim Conn-Kowlessar
0bd2db4f03 feat(modelling_e2e): price gap measures via overlay + broaden prediction to nearby postcodes
Two reconciliations to make the modelling_e2e Lambda handler production-ready.

1. Price through the off-catalogue overlay, drop the workarounds
   The handler priced through a plain ProductPostgresRepository and excluded
   secondary_heating_removal / system_tune_up / system_tune_up_zoned to dodge
   ProductNotFound (and a poisoning pgEnum DataError). Those measures are now
   priced by catalogue_with_off_catalogue_overrides (already used by the e2e
   runner and PostgresUnitOfWork), so the exclusions are removed and ALL measure
   types are considered. This also fixes gas-boiler / single-glazed properties,
   which Dan's handler never excluded and so still crashed (the standard
   system_tune_up option is built unconditionally — the considered-measures
   exclusion never actually gated it).

2. Broaden the EPC-Prediction cohort to nearby real postcodes (ADR-0031)
   A property with no lodged EPC and no same-type comparable in its own postcode
   (e.g. the only flat among houses) used to gate out and fail the subtask. The
   gov EPC API cannot search by radius/outcode, so we resolve the real unit
   postcodes physically nearest the target via postcodes.io (keyless; already a
   trusted in-repo dependency) and walk them nearest-first until enough same-type
   comparables surface. New PostcodesIoClient (transient-failure retry with
   exponential backoff, soft-failing to the seed so broadening never breaks
   prediction) and EpcComparablePropertiesRepository.candidates_near. Wired into
   the handler and e2e runner; broadening is lazy (only on gate-out) and memoised
   per (postcode, property_type).

Validated live: property 728476 (gas boiler) prices system_tune_up at GBP295;
property 718580 (lone flat in BR6 6BS) now predicts via nearby BR6 postcodes.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:25:18 +00:00
Jun-te Kim
8f0432721c test(accuracy): pin RdSAP-20.0.0 PV semi uprn_22086693 (PV-list fix corpus)
Corpus validation of the modelling_e2e photovoltaic_supply-as-list fix. Cert
6102-6227-8000-0083-2292 (RdSAP-20.0.0 semi, gas combi + 2× 1.14 kW PV arrays)
crashed from_rdsap_schema_20_0_0 on the measured-array list; the fix routes it
through the dict-tolerant _map_schema_21_pv. PV correctly credited: engine 61
(no PV) → 66 (+5). Built in Elmhurst (evidence: epc.json + summary + worksheet,
fabric+heating; the PV "New Technologies" Panel-details grid deferred): worksheet
55 = engine-on-Elmhurst-inputs 55 exactly → calculator faithful. The +6 engine-vs-
Elmhurst base-dwelling residual is the documented RdSAP-default gap (band-C cavity-
uninsulated suspended-floor semi). Pinned engine 66.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:13:34 +00:00
Jun-te Kim
75e4989982 Add moto[s3,sqs] to devcontainer for S3/SQS orchestration tests
tests/orchestration/test_postcode_splitter_orchestrator.py imports
`from moto import mock_aws` (moto 5.x) but moto was absent, so the file
errored at collection. Pin moto[s3,sqs]==5.0.28 (S3+SQS are the only mocked
services); resolves cleanly against the boto3 1.35.44 and cryptography 43.0.3
pins. All 4 tests pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:00:07 +00:00
Jun-te Kim
d4c120ede7
Merge pull request #1271 from Hestia-Homes/feature/task-handler-clean
Feature/task handler clean
2026-06-23 16:47:33 +01:00
Jun-te Kim
a7d3e00178 32 2026-06-23 15:42:00 +00:00
Jun-te Kim
119ff3740c fix(task_handler): persist cloud_logs_url for modelling_e2e
@task_handler never built or passed cloud_logs_url, so every app using
it (incl. modelling_e2e) ran run_subtask with the None default and the
CloudWatch deep-link was never saved onto the SubTask. @subtask_handler
did this correctly.

Extract the URL builder into a shared utilities/aws_lambda/cloud_logs.py
(public cloudwatch_url()), use it from both handlers, and pass the URL
into run_subtask from @task_handler. Add regression tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:42:00 +00:00
Jun-te Kim
451f0773e0 Log 2026-06-23 14:48 modelling_e2e failure sweep + e2e candidates in corpus worklist
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:41:57 +00:00
Jun-te Kim
75341da42d 32 2026-06-23 15:38:38 +00:00
Jun-te Kim
23ccfb0d0b Skip a landlord override that targets a building part the EPC lacks 🟩
A Landlord Override can reference a building part the lodged or predicted EPC
never carried (e.g. an extension_1 override on a property whose EPC has only
main). apply_simulations indexed parts_by_id[identifier] unguarded, raising
KeyError and aborting the whole property's modelling. Now the orphaned part is
skipped. Recovers 14 of the 22 modelling_e2e failures in portfolio 796.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:36:37 +00:00
Jun-te Kim
d1a2ee11e8 fix(task_handler): persist cloud_logs_url for modelling_e2e
@task_handler never built or passed cloud_logs_url, so every app using
it (incl. modelling_e2e) ran run_subtask with the None default and the
CloudWatch deep-link was never saved onto the SubTask. @subtask_handler
did this correctly.

Extract the URL builder into a shared utilities/aws_lambda/cloud_logs.py
(public cloudwatch_url()), use it from both handlers, and pass the URL
into run_subtask from @task_handler. Add regression tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:47 +00:00
Jun-te Kim
539f661430 Skip a landlord override that targets a building part the EPC lacks 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:19 +00:00
Jun-te Kim
17b1d63f0e test(accuracy): pin SAP-16.0 storage-flat uprn_10070004512 (built_form fix corpus)
Corpus validation of the modelling_e2e built_form fix. Cert 8742-6624-9300-2780-4926
(SAP-Schema-16.0, ground-floor electric-storage-heater flat) omits built_form; the
mapper now derives it from dwelling_type. built_form is ML-only so the fix is
SAP-neutral: engine 66 = lodged 66 exactly. Built in Elmhurst (evidence: epc.json +
summary + worksheet): worksheet 54, engine-on-Elmhurst-inputs 53 ≈ 54 → calculator
faithful. The +12 engine-vs-Elmhurst is a build/input gap (cert size-1 small cylinder
unrepresentable in Elmhurst's Normal/110L-minimum entry → higher HW + reduced-field
16.0 defaults). Pinned engine 66.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:06 +00:00
Daniel Roth
4e3eb52a37
Merge pull request #1268 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
Feature/hyde make it more accurate with tests
2026-06-23 16:08:05 +01:00
Jun-te Kim
5737923622 32 and delete in plan 2026-06-23 15:01:34 +00:00
Jun-te Kim
6ee2f6257a fix(mapper): close modelling_e2e cohort mapping gaps (built_form, PV-list, windows-dict)
Closes the mapper-coverage gaps surfaced by the modelling_e2e prediction-cohort
failures (portfolio 796):

- built_form (SAP-16.0): derive from dwelling_type in _normalize_sap_schema_16_x
  (Mid-terrace->4, End-terrace->3, Semi-detached->2, Detached->1; flats->modal 4).
  ML-only field (SAP calc never reads it) so SAP- and gate-neutral. 5 flat certs
  that omitted built_form now map.
- photovoltaic_supply as a measured-array LIST: routed all pre-21 RdSAP mappers
  (17.0/17.1/18.0/19.0/20.0.0) through _map_schema_21_pv, whose list branch is now
  dict-tolerant (_pv_array_field reads dict OR dataclass). They capture the PV
  arrays like 21.0.x instead of raising "'list' object has no attribute
  none_or_no_details" and sinking the whole cohort.
- windows-as-dict (16.x): handled in the normalizer (not just windows-as-list).

Genuinely-sparse certs (omit door_count/habitable/glazed_area) remain fail-loud;
the gate-regressing multiple_glazed_proportion default and the recursive
RdSAP-21.0.0 ADR-0028 alignment are left fail-loud + flagged for review (worklist).

+5 regression tests; component-accuracy gate 26/26; 0 new pyright errors.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 14:51:40 +00:00
Daniel Roth
f09f01adbf
Merge pull request #1266 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
test for 16
2026-06-23 15:20:17 +01:00
Jun-te Kim
c12bfc7413 test for 16 2026-06-23 14:11:30 +00:00
Daniel Roth
cbc14f1ca2 better tracking of already processed properties 2026-06-23 14:09:59 +00:00
Daniel Roth
aa92ffaac1 Merge branch 'main' into trigger-e2e-locally 2026-06-23 13:41:29 +00:00