Three silent-drop extraction fixes the gov-API/Elmhurst mappers already apply
but `from_site_notes` uniquely omitted — each let a favorable default reach the
SAP-10.2 calculator and over-rate the dwelling. Same calculator, so the whole
gap was extraction fidelity (gov-API corpus 78.6% within-0.5 vs pashub 23.9%).
#1598 — electric-shower + bath counts: `_map_sap_heating` built `shower_outlets`
but never set `electric_shower_count`/`mixer_shower_count`/`number_baths`, so
the cascade defaulted to 1 gas mixer / 0 electric, billing electric-shower hot
water off the cheap main system. 100/205 fixtures lodge "Electric Shower".
#1599 — floor label: pashub lodges "Ground Floor" (capital F); the calculator's
RdSAP §5(12) suspended-timber floor-infiltration gate is case-sensitive on
"Ground floor", so the 0.2-ACH term was silently dropped. Normalized at the
mapper boundary. 98/205 suspended-timber.
#1600 — water-heating "None": the RdSAP 10 §10.7 "no water heating system"
signal was discarded and HW inherited the gas combi (58 Hackle 67.7 vs
verified 59). Coded to WHC 999 so the existing electric-immersion + Table
28/29 default fires (also folds in #1594: blank cylinder size is no cylinder,
not a phantom one).
Guinness GMCA 205 cohort: within-0.5 23.9% -> 50.2% (103/205), MAE 1.410 ->
0.650. Ratchets tightened to 0.50 / 0.65. Verified vs Khalim's ground truth
(16 Stillwater 78.2 -> 75.7 vs 76). #1601 (upper-floor +0.25 m) held — it
empirically over-corrects this cohort (internal-vs-external dimension question,
under investigation). pyright: 0 new errors.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Khalim-authorised MAE loosening: coding window orientation exposes the known
SAP-10.2-vs-lodged offset the zeroed solar gains were masking; within-0.5 is
the north-star metric and jumps 20.0% -> 23.9%.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Manually verified in pashub (Khalim, 2026-07-14): deal 499584755922
(9 Council Houses, CW5 8AP) is F33, not the stale D67 — our computed 34.0
was right within a point; deal 499617935574 (Brightholme, 14 North Road)
is the accredited E43, not the preliminary 53. 58 Hackle Street (D58) and
16 Bingley Close (E52) were confirmed correct, so our +7.8/+5.7 deviations
there are extraction bugs to hunt next. Harness MAE 1.684 -> 1.551; ceiling
ratcheted to 1.56.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The extractor now captures "Heating System (Other):" and the mapper resolves
it to the Table 4a code (301, community boilers) + Table 12 community fuel
(51 via the shared _resolve_community_heating_fuel_code), so
is_heat_network_main routes the DLF / standing-charge / 80%-efficiency
branch instead of pricing the dwelling as an ordinary mains-gas boiler
(fixture 507644414148: +14.3 over-rate closes by ~8.6). Harness MAE
1.726 -> 1.684; ceiling ratcheted to 1.70.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
_parse_room_in_roof captures the RdSAP §3.10 block (age range, floor area,
gables with Exposed/Party type, slopes, common walls, flat ceiling as
length x height) on main and extension roof spaces; both part builders now
carry it to sap_room_in_roof (issue #1590 bug 5 — closes the last #1590
subtask). Harness MAE 1.748 (754917 corrects to pashub's own pre-SAP; RIR
surfaces now billed per-surface instead of as insulated loft).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The surveyed "Ventilation type" label never reached
mechanical_ventilation_kind, so ventilation_from_cert silently defaulted every
mechanical system to NATURAL (24d), dropping its ACH heat loss — 76/205
cohort fixtures lodge dMEV/MEV/PIV (issue #1590 bug 4). Mapping mirrors the
gov-API _API_MECHANICAL_VENTILATION_TO_KIND table (PIV-from-loft is
"as natural"). Harness: within-0.5 12.2% -> 18.5%, MAE 2.538 -> 1.730 — the
campaign's largest single move; floors ratcheted to 0.18 / 1.75.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
"Not connected to electricity meter" -> 1 (zero Appendix M credit), "Connected
to dwellings electricity meter" -> 2; the raw string fell through the credit
gate's non-int branch to True, crediting a separately-metered array (issue
#1590 bug 3, fixture 499516101839 -6.9 SAP). Harness MAE 2.571 -> 2.538;
ceiling ratcheted to 2.55.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
"Photovoltaic array kWp Known? Yes" lodges a per-system block (kWp, pitch,
orientation, overshading) instead of the percent-roof estimate; the extractor
only read the estimate, so measured PV never reached the mapper and the
Appendix M credit was silently zero (issue #1590 bug 1). Harness MAE
2.632 -> 2.571 (fixture 507639151843's 13.5-SAP under-rate closes to +0.5);
ceiling ratcheted to 2.58.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
"Insulation At: None" is the assessor recording zero loft insulation, not an
unknown — with thickness left None, u_roof fell through to the age-band
"assumed insulated" default (0.16 W/m²K at band J/K) instead of the Table 16
uninsulated row (2.30), understating roof loss ~14x (issue #1590 bug 2).
Harness MAE 2.701 -> 2.632 (the two ~7-SAP roof over-raters correct exactly);
ceiling ratcheted to 2.64.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Two hubspot_deal_data corrections: 499539910905 D58->B82 (confirmed bad row)
and one C73->C75. Rebuilt via scripts/build_pashub_accuracy_fixtures.py
(no --force; PDFs unchanged).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Secondary fuel 'Mains gas'/'Mains Gas'->26 and 'House Coal'->11 (Table 32);
main-heating control resolution becomes group-aware with a Table 4e Group 3
map ('Charging system linked to use of community heating, room thermostat
only' -> 2306, the code the accredited Elmhurst certs lodge for this cohort;
all four linked-to-use codes are calculation-identical). All 205 Guinness
fixtures now compute (was 201/4 xfails); ratchet re-baselined to the
full-coverage aggregate (12.2% within-0.5 floor, MAE ceiling 2.71) with the
two newly-computable outliers documented for verification.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The control gap surfaces as UnmappedSapCode on main and as UnmappedPasHubLabel
once the #1557 control mapper lands (unmapped community-heating control), so the
harness must swallow both; only the closed fuel-specific MissingMainFuelType is
dropped as a fuel-drop tripwire.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Foundation for PRD #1555: runs each PAS Hub site-note PDF through the
extractor -> EpcPropertyData -> Sap10Calculator and gauges the computed
SAP against pashub's own SAP-10.2 `pre_sap` (from hubspot_deal_data).
- test_pashub_sap_accuracy.py: hybrid gate. Per-fixture "must compute"
(xfail on the known in-progress mapper gaps MissingMainFuelType /
UnmappedSapCode / UnmappedPasHubLabel) + aggregate within-0.5 ratchet
floor, mirroring test_sap_accuracy_corpus.py.
- 205 image-stripped site-note PDFs + manifest.json. Images stripped so
the repo footprint stays ~52MB while the text layer the extractor reads
is byte-identical.
- build_pashub_accuracy_fixtures.py: provenance/rebuild from S3 +
hubspot_deal_data.
All 206 currently xfail on the known heating-string mapper gaps; each fix
(#1556-1568) flips its fixtures to computing and ratchets the floor.
Refs #1555#1568
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Thread the UPRN the PashubService has already resolved for a job into the
PasHub site-notes mapper so the EpcPropertyData aggregate is born with its
uprn set, and the existing save_epc_property_data path persists it.
- EpcPropertyDataMapper.from_site_notes gains uprn: Optional[int] = None and
sets it unconditionally (site notes never carry a UPRN natively).
- parse_site_notes_pdf / _parse_pashub forward the uprn; the Elmhurst branch
is untouched.
- PashubService coerces uprn str -> int in one place, carries it on the
internal upload record, and passes it into parse_site_notes_pdf.
- No new lookups; jobs with no known UPRN still persist null, unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Both flagged mismatches were Elmhurst input errors (same silent-stale-value
contamination class as the earlier chimneys/wall-thickness bugs), not
parser or calculator bugs:
- cylinder_size: build_100010086084.py's water_heating() selected
DropDownListCylinderSize by raw value "2", but this DOM's option values
ARE their visible litre-band text (no "2" among them) — Playwright
silently no-ops on a non-matching value, leaving a prior cert's "Medium
(131-170L)" selection in place. Fixed to match by text ("Normal"), and
added the missing mapper dict entries (Normal/Large litre-suffixed
labels) to _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10 (a real mapper-coverage
gap — the calculator raises UnmappedElmhurstLabel rather than silently
mis-mapping).
- boiler_flue_type: the boiler-code search dialog's combined "Balanced/Open
Flue" Table 4b category doesn't drive the separate, independently
selectable RadioButtonListFlueType field, which was left at an inherited
"Balanced" from a prior cert. Fixed space_heating() to explicitly select
"Open" to match the lodged gov-API code. This field isn't consumed by
Sap10Calculator (ML/generator-only), so it had zero effect on the SAP
score.
Re-downloaded elmhurst_summary.pdf/elmhurst_worksheet.pdf after the fixes
(Recommendations page confirmed clean). Elmhurst-PDF-inputs path moved
46->47 SAP from the cylinder-volume correction; gov-API SAP (53) and
Elmhurst's own worksheet (51) are unchanged. Full accuracy suites re-run
clean (67 passed, 67 skipped, 1 xfailed, same as before).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
The Elmhurst rebuild for this cert had two carryover bugs from the shared
Playwright session: TextBoxOpenChimneys silently inherited "2" from a prior
cert's build (this cert's register lodges open_fireplaces_count=0, which
the gov-API mapper already reads correctly), and wall thickness inherited
a stale 280mm. Also fixed a real bug in the space_heating() PCDB-ref-clearing
logic: input_value() returns the string "0" when already cleared, which is
truthy in Python, causing a spurious navigate-away that broke the next
E.goto() call.
Rebuilt cleanly (chimneys=0, wall thickness=220mm per RdSAP convention for
unrecorded solid-wall thickness, since CheckBoxWallThicknessUnknown does not
persist via Playwright in this tool version). Elmhurst's own worksheet score
moves from a contaminated 46/48 to 51, closing the gap against this engine's
53-on-gov-API-inputs from ~5-7pt to ~2pt. No mapper.py change was needed --
the gov-API mapper's open_chimneys_count=0 was correct all along.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Built UPRN 100010086084 (the largest gov-API-vs-lodged outlier from the
20-cert batch) in Elmhurst's accredited RdSAP10 tool to get real ground
truth, per feedback that lodged rating isn't a valid comparison target.
Elmhurst worksheet: SAP 46-48 (orientation-dependent), vs this engine's
53 on gov-API inputs -- a real ~5-7pt residual gap. Ruled out with
direct empirical tests: total_floor_area, missing party_wall_length,
region/climate (SAP rating always uses UK-average weather per Appendix
U -- confirmed inert), boiler/secondary efficiency (exact match, 66%/
63% both sides). Confirmed real but NOT blind-fixed (need more than one
cert's evidence, and a wall-U-value patch tested the wrong direction in
isolation): a wall-thickness-unknown U-value fallback mismatch (this
engine 1.70, Elmhurst's own "unknown" resolution 1.40) and a window
U-value divergence (1.85 vs 2.52 W/m2K for the same nominal glazing
pick). Single-window orientation confirmed a ~2pt partial contributor.
Also fixes a small, separate, evidenced gap the build surfaced: the
Elmhurst summary parser didn't recognise the live tool's "Medium
(131-170L)" cylinder-size label (only the bare "Medium").
Full write-up is in the RealCertExpectation comment for this cert in
test_real_cert_sap_accuracy.py and the worklist. Residual gap is
intentionally left open for follow-up, not force-closed.