Khalim Conn-Kowlessar
30b1728337 PasHub extraction: thread showers/baths, normalize floor label, code no-water-heating 🟩
Three silent-drop extraction fixes the gov-API/Elmhurst mappers already apply
but `from_site_notes` uniquely omitted — each let a favorable default reach the
SAP-10.2 calculator and over-rate the dwelling. Same calculator, so the whole
gap was extraction fidelity (gov-API corpus 78.6% within-0.5 vs pashub 23.9%).

#1598 — electric-shower + bath counts: `_map_sap_heating` built `shower_outlets`
  but never set `electric_shower_count`/`mixer_shower_count`/`number_baths`, so
  the cascade defaulted to 1 gas mixer / 0 electric, billing electric-shower hot
  water off the cheap main system. 100/205 fixtures lodge "Electric Shower".
#1599 — floor label: pashub lodges "Ground Floor" (capital F); the calculator's
  RdSAP §5(12) suspended-timber floor-infiltration gate is case-sensitive on
  "Ground floor", so the 0.2-ACH term was silently dropped. Normalized at the
  mapper boundary. 98/205 suspended-timber.
#1600 — water-heating "None": the RdSAP 10 §10.7 "no water heating system"
  signal was discarded and HW inherited the gas combi (58 Hackle 67.7 vs
  verified 59). Coded to WHC 999 so the existing electric-immersion + Table
  28/29 default fires (also folds in #1594: blank cylinder size is no cylinder,
  not a phantom one).

Guinness GMCA 205 cohort: within-0.5 23.9% -> 50.2% (103/205), MAE 1.410 ->
0.650. Ratchets tightened to 0.50 / 0.65. Verified vs Khalim's ground truth
(16 Stillwater 78.2 -> 75.7 vs 76). #1601 (upper-floor +0.25 m) held — it
empirically over-corrects this cohort (internal-vs-external dimension question,
under investigation). pyright: 0 new errors.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-15 13:52:13 +00:00
Khalim Conn-Kowlessar
bb7f05693c Update golden for the secondary-heating int-code + retighten pashub MAE post-#1592-revert
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 09:15:46 +00:00
Khalim Conn-Kowlessar
21674d5ed0 Re-baseline the pashub gauge to 23% within-0.5 / MAE 1.41 for the orientation fix
Khalim-authorised MAE loosening: coding window orientation exposes the known
SAP-10.2-vs-lodged offset the zeroed solar gains were masking; within-0.5 is
the north-star metric and jumps 20.0% -> 23.9%.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 08:51:52 +00:00
Khalim Conn-Kowlessar
b208234e62 Ratchet the pashub accuracy gauge to MAE 1.371 after the common-wall fix
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 08:40:39 +00:00
Khalim Conn-Kowlessar
7c2cb6b88a Ratchet the pashub accuracy gauge to MAE 1.37 after the common-wall fix
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 08:35:56 +00:00
Khalim Conn-Kowlessar
8a753822c8 Capture the Simplified RIR 'Roof room type' label from the survey 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 08:27:01 +00:00
Khalim Conn-Kowlessar
600262819c Capture the Simplified RIR 'Roof room type' label from the survey 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 08:25:11 +00:00
Khalim Conn-Kowlessar
948704d7b0 Record the secondary-heating-type coding fix in the accuracy ratchet note
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 00:28:40 +00:00
Khalim Conn-Kowlessar
390a818587 Ratchet the pashub accuracy gauge to 19% within-0.5 / MAE 1.39
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-15 00:05:13 +00:00
Khalim Conn-Kowlessar
483b69ff41 Capture the surveyed Wall Dry-Lined answer per building part 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-14 23:20:36 +00:00
Khalim Conn-Kowlessar
0b47798403 Capture the surveyed Wall Dry-Lined answer per building part 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-14 23:20:09 +00:00
Khalim Conn-Kowlessar
8e58f7e871 Capture the per-surface RIR insulation-known answer from the survey 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-14 23:12:08 +00:00
Khalim Conn-Kowlessar
d743f6fb3b Capture the per-surface RIR insulation-known answer from the survey 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-14 23:11:09 +00:00
Khalim Conn-Kowlessar
e0b189aa6d Correct two pashub-verified pre_sap values in the accuracy manifest
Manually verified in pashub (Khalim, 2026-07-14): deal 499584755922
(9 Council Houses, CW5 8AP) is F33, not the stale D67 — our computed 34.0
was right within a point; deal 499617935574 (Brightholme, 14 North Road)
is the accredited E43, not the preliminary 53. 58 Hackle Street (D58) and
16 Bingley Close (E52) were confirmed correct, so our +7.8/+5.7 deviations
there are extraction bugs to hunt next. Harness MAE 1.684 -> 1.551; ceiling
ratcheted to 1.56.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 22:42:03 +00:00
Khalim Conn-Kowlessar
f45651dbc0 Lodge the heat-network SAP code and Table 12 community fuel for PasHub community heating 🟩
The extractor now captures "Heating System (Other):" and the mapper resolves
it to the Table 4a code (301, community boilers) + Table 12 community fuel
(51 via the shared _resolve_community_heating_fuel_code), so
is_heat_network_main routes the DLF / standing-charge / 80%-efficiency
branch instead of pricing the dwelling as an ordinary mains-gas boiler
(fixture 507644414148: +14.3 over-rate closes by ~8.6). Harness MAE
1.726 -> 1.684; ceiling ratcheted to 1.70.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 22:34:50 +00:00
Khalim Conn-Kowlessar
4d60d79cc9 Extract the PasHub community heat-source label 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 22:33:08 +00:00
Khalim Conn-Kowlessar
955b4dc1e8 Extract the PasHub detailed room-in-roof block 🟩
_parse_room_in_roof captures the RdSAP §3.10 block (age range, floor area,
gables with Exposed/Party type, slopes, common walls, flat ceiling as
length x height) on main and extension roof spaces; both part builders now
carry it to sap_room_in_roof (issue #1590 bug 5 — closes the last #1590
subtask). Harness MAE 1.748 (754917 corrects to pashub's own pre-SAP; RIR
surfaces now billed per-surface instead of as insulated loft).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 22:09:44 +00:00
Khalim Conn-Kowlessar
518c682793 Extract the PasHub detailed room-in-roof block 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 22:05:31 +00:00
Khalim Conn-Kowlessar
090e16ddc2 Dispatch PasHub mechanical ventilation into the §2 ACH cascade 🟩
The surveyed "Ventilation type" label never reached
mechanical_ventilation_kind, so ventilation_from_cert silently defaulted every
mechanical system to NATURAL (24d), dropping its ACH heat loss — 76/205
cohort fixtures lodge dMEV/MEV/PIV (issue #1590 bug 4). Mapping mirrors the
gov-API _API_MECHANICAL_VENTILATION_TO_KIND table (PIV-from-loft is
"as natural"). Harness: within-0.5 12.2% -> 18.5%, MAE 2.538 -> 1.730 — the
campaign's largest single move; floors ratcheted to 0.18 / 1.75.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:45:24 +00:00
Khalim Conn-Kowlessar
56b36ce7f0 Resolve the PasHub PV Connection label to the gov-API credit-gate int 🟩
"Not connected to electricity meter" -> 1 (zero Appendix M credit), "Connected
to dwellings electricity meter" -> 2; the raw string fell through the credit
gate's non-int branch to True, crediting a separately-metered array (issue
#1590 bug 3, fixture 499516101839 -6.9 SAP). Harness MAE 2.571 -> 2.538;
ceiling ratcheted to 2.55.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:41:04 +00:00
Khalim Conn-Kowlessar
f92d4f26b8 Extract the PasHub per-system PV block and diverter flag 🟩
"Photovoltaic array kWp Known? Yes" lodges a per-system block (kWp, pitch,
orientation, overshading) instead of the percent-roof estimate; the extractor
only read the estimate, so measured PV never reached the mapper and the
Appendix M credit was silently zero (issue #1590 bug 1). Harness MAE
2.632 -> 2.571 (fixture 507639151843's 13.5-SAP under-rate closes to +0.5);
ceiling ratcheted to 2.58.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:38:07 +00:00
Khalim Conn-Kowlessar
80de9b0c04 Extract the PasHub per-system PV block and diverter flag 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:35:34 +00:00
Khalim Conn-Kowlessar
bc58cf4930 Lodge explicit zero roof insulation for a surveyed "Insulation At: None" 🟩
"Insulation At: None" is the assessor recording zero loft insulation, not an
unknown — with thickness left None, u_roof fell through to the age-band
"assumed insulated" default (0.16 W/m²K at band J/K) instead of the Table 16
uninsulated row (2.30), understating roof loss ~14x (issue #1590 bug 2).
Harness MAE 2.701 -> 2.632 (the two ~7-SAP roof over-raters correct exactly);
ceiling ratcheted to 2.64.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:28:25 +00:00
Khalim Conn-Kowlessar
999008f9d0 Refresh pashub accuracy manifest pre_sap from the corrected DB rows
Two hubspot_deal_data corrections: 499539910905 D58->B82 (confirmed bad row)
and one C73->C75. Rebuilt via scripts/build_pashub_accuracy_fixtures.py
(no --force; PDFs unchanged).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:24:37 +00:00
Khalim Conn-Kowlessar
cab7e3d613 Close the last PasHub mapper gaps: secondary fuel + Group 3 heat-network control 🟩
Secondary fuel 'Mains gas'/'Mains Gas'->26 and 'House Coal'->11 (Table 32);
main-heating control resolution becomes group-aware with a Table 4e Group 3
map ('Charging system linked to use of community heating, room thermostat
only' -> 2306, the code the accredited Elmhurst certs lodge for this cohort;
all four linked-to-use codes are calculation-identical). All 205 Guinness
fixtures now compute (was 201/4 xfails); ratchet re-baselined to the
full-coverage aggregate (12.2% within-0.5 floor, MAE ceiling 2.71) with the
two newly-computable outliers documented for verification.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 21:24:36 +00:00
Daniel Roth
ecb113b52e Re-ratchet PasHub SAP-accuracy floor to the current integrated aggregate (12.4% within-0.5) 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:57:34 +00:00
Daniel Roth
df3fce0a3f
Merge branch 'main' into feature/pashub-map-main-heating-control-1557 2026-07-14 18:50:08 +01:00
Daniel Roth
98aa0127a7 Keep swallowing the control gap's boundary form in the accuracy harness 🟪
The control gap surfaces as UnmappedSapCode on main and as UnmappedPasHubLabel
once the #1557 control mapper lands (unmapped community-heating control), so the
harness must swallow both; only the closed fuel-specific MissingMainFuelType is
dropped as a fuel-drop tripwire.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:40:50 +00:00
Daniel Roth
88f221b86e Stop swallowing closed PAS Hub main-fuel gaps in the accuracy harness 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:24:15 +00:00
Daniel Roth
8529c71ff2 Capture PAS Hub main-heating fuel from the colon 'Fuel:' label variant 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:19:12 +00:00
Daniel Roth
2783c2c0c6 Capture PAS Hub main-heating fuel from the colon 'Fuel:' label variant 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 17:18:46 +00:00
Daniel Roth
aa69462b5b Raise PasHub SAP-accuracy floor to 13.4% within-0.5 on the merged fabric stack 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 16:55:03 +00:00
Daniel Roth
5da621c7a5 Ratchet PasHub SAP-accuracy floor to 10.9% within-0.5 (control-code fix unblocks 201/205) 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 16:43:54 +00:00
Khalim Conn-Kowlessar
e5fee3896a Add PAS Hub SAP-accuracy regression harness (Guinness 205 cohort)
Foundation for PRD #1555: runs each PAS Hub site-note PDF through the
extractor -> EpcPropertyData -> Sap10Calculator and gauges the computed
SAP against pashub's own SAP-10.2 `pre_sap` (from hubspot_deal_data).

- test_pashub_sap_accuracy.py: hybrid gate. Per-fixture "must compute"
  (xfail on the known in-progress mapper gaps MissingMainFuelType /
  UnmappedSapCode / UnmappedPasHubLabel) + aggregate within-0.5 ratchet
  floor, mirroring test_sap_accuracy_corpus.py.
- 205 image-stripped site-note PDFs + manifest.json. Images stripped so
  the repo footprint stays ~52MB while the text layer the extractor reads
  is byte-identical.
- build_pashub_accuracy_fixtures.py: provenance/rebuild from S3 +
  hubspot_deal_data.

All 206 currently xfail on the known heating-string mapper gaps; each fix
(#1556-1568) flips its fixtures to computing and ratchets the floor.

Refs #1555 #1568

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 15:32:18 +00:00
Daniel Roth
442352c378 Drop the unused DownloadedFile import from the client tests 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:07:23 +00:00
Daniel Roth
38cae15f4d Preserve SharePoint distribution when the site-note save fails loudly 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
e31d2ad2d1 Preserve SharePoint distribution when the site-note save fails loudly 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
62c0151469 Fill partial summaries best-effort, fail loudly, skip evidence-only jobs, and retry on Coordination Hub 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
377c030c77 Overlay PasHub as-surveyed performance onto saved Site-Notes property 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
43fac40595 Overlay PasHub as-surveyed performance onto saved Site-Notes property 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
ded8cf1e46 Raise loudly when RdSAP Summary fetch returns an HTTP error 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
eff4f64426 Raise loudly when RdSAP Summary fetch returns an HTTP error 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
83d92010de Raise UnauthorizedError when RdSAP Summary fetch returns 401 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
b596f32af1 Raise UnauthorizedError when RdSAP Summary fetch returns 401 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
af6c461c93 Map PasHub RdSAP Summary response to as-surveyed performance values 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
85482cdf9e Map PasHub RdSAP Summary response to as-surveyed performance values 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-07-14 14:06:45 +00:00
Daniel Roth
b5c05166db Persist resolved UPRN on PasHub site-notes rows (#1537)
Thread the UPRN the PashubService has already resolved for a job into the
PasHub site-notes mapper so the EpcPropertyData aggregate is born with its
uprn set, and the existing save_epc_property_data path persists it.

- EpcPropertyDataMapper.from_site_notes gains uprn: Optional[int] = None and
  sets it unconditionally (site notes never carry a UPRN natively).
- parse_site_notes_pdf / _parse_pashub forward the uprn; the Elmhurst branch
  is untouched.
- PashubService coerces uprn str -> int in one place, carries it on the
  internal upload record, and passes it into parse_site_notes_pdf.
- No new lookups; jobs with no known UPRN still persist null, unchanged.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-10 13:19:28 +00:00
Jun-te Kim
e91e0fa33e Fix cylinder_size/boiler_flue_type input errors for UPRN 100010086084 (SAP-15.0)
Both flagged mismatches were Elmhurst input errors (same silent-stale-value
contamination class as the earlier chimneys/wall-thickness bugs), not
parser or calculator bugs:

- cylinder_size: build_100010086084.py's water_heating() selected
  DropDownListCylinderSize by raw value "2", but this DOM's option values
  ARE their visible litre-band text (no "2" among them) — Playwright
  silently no-ops on a non-matching value, leaving a prior cert's "Medium
  (131-170L)" selection in place. Fixed to match by text ("Normal"), and
  added the missing mapper dict entries (Normal/Large litre-suffixed
  labels) to _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10 (a real mapper-coverage
  gap — the calculator raises UnmappedElmhurstLabel rather than silently
  mis-mapping).

- boiler_flue_type: the boiler-code search dialog's combined "Balanced/Open
  Flue" Table 4b category doesn't drive the separate, independently
  selectable RadioButtonListFlueType field, which was left at an inherited
  "Balanced" from a prior cert. Fixed space_heating() to explicitly select
  "Open" to match the lodged gov-API code. This field isn't consumed by
  Sap10Calculator (ML/generator-only), so it had zero effect on the SAP
  score.

Re-downloaded elmhurst_summary.pdf/elmhurst_worksheet.pdf after the fixes
(Recommendations page confirmed clean). Elmhurst-PDF-inputs path moved
46->47 SAP from the cylinder-volume correction; gov-API SAP (53) and
Elmhurst's own worksheet (51) are unchanged. Full accuracy suites re-run
clean (67 passed, 67 skipped, 1 xfailed, same as before).

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-10 09:11:41 +00:00
Jun-te Kim
798d19d6ff Fix contaminated Elmhurst ground truth for UPRN 100010086084 (SAP-15.0)
The Elmhurst rebuild for this cert had two carryover bugs from the shared
Playwright session: TextBoxOpenChimneys silently inherited "2" from a prior
cert's build (this cert's register lodges open_fireplaces_count=0, which
the gov-API mapper already reads correctly), and wall thickness inherited
a stale 280mm. Also fixed a real bug in the space_heating() PCDB-ref-clearing
logic: input_value() returns the string "0" when already cleared, which is
truthy in Python, causing a spurious navigate-away that broke the next
E.goto() call.

Rebuilt cleanly (chimneys=0, wall thickness=220mm per RdSAP convention for
unrecorded solid-wall thickness, since CheckBoxWallThicknessUnknown does not
persist via Playwright in this tool version). Elmhurst's own worksheet score
moves from a contaminated 46/48 to 51, closing the gap against this engine's
53-on-gov-API-inputs from ~5-7pt to ~2pt. No mapper.py change was needed --
the gov-API mapper's open_chimneys_count=0 was correct all along.

Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
2026-07-10 08:36:03 +00:00
Jun-te Kim
283b311fcd Real Elmhurst RdSAP10 ground truth for one SAP-Schema-15.0 cert
Built UPRN 100010086084 (the largest gov-API-vs-lodged outlier from the
20-cert batch) in Elmhurst's accredited RdSAP10 tool to get real ground
truth, per feedback that lodged rating isn't a valid comparison target.

Elmhurst worksheet: SAP 46-48 (orientation-dependent), vs this engine's
53 on gov-API inputs -- a real ~5-7pt residual gap. Ruled out with
direct empirical tests: total_floor_area, missing party_wall_length,
region/climate (SAP rating always uses UK-average weather per Appendix
U -- confirmed inert), boiler/secondary efficiency (exact match, 66%/
63% both sides). Confirmed real but NOT blind-fixed (need more than one
cert's evidence, and a wall-U-value patch tested the wrong direction in
isolation): a wall-thickness-unknown U-value fallback mismatch (this
engine 1.70, Elmhurst's own "unknown" resolution 1.40) and a window
U-value divergence (1.85 vs 2.52 W/m2K for the same nominal glazing
pick). Single-window orientation confirmed a ~2pt partial contributor.

Also fixes a small, separate, evidenced gap the build surfaced: the
Elmhurst summary parser didn't recognise the live tool's "Medium
(131-170L)" cylinder-size label (only the bare "Medium").

Full write-up is in the RealCertExpectation comment for this cert in
test_real_cert_sap_accuracy.py and the worklist. Residual gap is
intentionally left open for follow-up, not force-closed.
2026-07-09 22:31:01 +00:00