Reusable per-schema profiler: glazed_area band mix, Validation Cohort size,
observed-vs-predicted band glazing/floor ratio, and the ND/str sentinels that
drive schema widening. Regenerates the ADR-0028 transfer-check table from any
harvested corpus.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Promote RdSAP-Schema-19.0 into SUPPORTED so all 1000 corpus certs are held to
the strict parse+map guard. Drop the now-redundant cert[0] tracer (subsumed by
the parametrised bucket); keep the reduced-field synthesis behavioural test.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add the 19.0 synthesis seam over the shared _synthesise_reduced_field_windows
core (inherited 20.0.0 coefficients, ND glazing -> DG-modal default 2, per
ADR-0028). 19.0 glazed_type codes (1-4,6,7) are a subset of the verified 1-8
space. The 6 rich certs use lodged window_area directly; the windowless 994
synthesise a 4-way N/E/S/W split.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Dispatch RdSAP-Schema-19.0 through from_api_response, parse-fix the schema
(data-driven required->optional, validated against the 1000-cert 19.0 corpus
per ADR-0028), and port 18.0's defensive mapper reads (dwelling_type str/dict/
number, photovoltaic_supply guard, sap_room_in_roof Measurement coercion).
All 1000 corpus certs now parse and map.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
ADR-0028's deferred extraction, triggered by 17.1 as the second instance: the
inherited 20.0.0 coefficients (0.148 + band multipliers + 4-way split) now live
in one `_synthesise_reduced_field_windows` core. The 20.0.0 / 18.0 / 17.1 seams
keep their own names (so each can diverge) but collapse to glazing-type
resolution (cascade + that spec's ND handling) plus a call to the core.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Rich certs (14/1000) use lodged window_area; the windowless majority synthesise
glazing from the glazed_area band via _synthesise_17_1_sap_windows (own seam,
inherited 20.0.0 coefficients); lighting/ventilation/hot-water mirror 18.0.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Schema-fix delivered in the prior slice; this promotes the 1000-cert corpus
into the strict guard (matches 18.0/20.0.0).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Documents the inherit-and-validate decision for 18.0: reuse 20.0.0's 0.148 +
band multipliers (the corpus can't self-fit — 958/1000 band-1 with no measured
band-1 windows), validated against 18.0's own band-4 rich certs (0.223 obs vs
0.148 x 1.51 pred). References ADR-0027 one-way (keeps the accepted ADR immutable).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Behaviour delivered by the band-multiplier dict in the prior slice; this pins
the band-2 ("More than typical") case against the inherited 20.0.0 coefficient.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Drops the xfail now that Reduced-Field Synthesis (ADR-0027) maps every
20.0.0 cert; the corpus test holds the whole bucket to a strict 1000/1000.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
ADR-0027 Reduced-Field Synthesis: certs with no per-window array now get total
glazing = 0.148 x TFA x band-multiplier (median + quartile multipliers fit from
the 1000 real 21.0.1 certs), split 4-way across N/E/S/W with width=area/4,
height=1.0; glazing_type routed through the verified 21.0.1 cascade. Also guard
optional PhotovoltaicSupply.none_or_no_details (a parse straggler). Corpus maps
983/1000, up from 974.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Required->optional defaults (kw_only + data-driven from corpus presence) so
993/1000 certs that omit sap_windows parse, and honest Union[str, DescriptionV1]
typing for description/dwelling_type which the corpus lodges as localised dicts
in ~half the certs. The never-run 20.0.0 mapper path now produces EpcPropertyData;
974/1000 corpus certs map (xpass), up from 7.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Sharpen the glossary to decouple deterministic old-schema re-mapping from
neighbour-prediction gap-fill (a separate, unimplemented ML path), and add
the Reduced-Field Synthesis term. ADR-0027 records the pre-SAP10 20.0.0
mapper's best-attempt synthesis (corpus-fit glazing 0.148xTFAxband, 4-way
orientation) and its trade-offs. Grill resume doc captures every resolved branch.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:
- system_tune_up — standard controls (programmer + room thermostat +
TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned — time-and-temperature zone control (code 2110, type 3):
more SAP uplift for more cost
Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.
Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).
Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the `gas_boiler_upgrade` branch to `report._triggers_for`, mirroring the
generator's eligibility guard so a cohort report explains why the boiler upgrade
fired: the wet-boiler SAP code, the mains-gas connection that makes the gas
end-state installable, and the cylinder presence that shapes the bundle (combi
vs regular + cylinder fixes).
No golden API cert selects the boiler upgrade (it competes with — and on houses
loses to — the ASHP bundle within the one heating Recommendation), so the branch
is covered by a direct `_triggers_for` unit test, following the repo pattern for
testing internal helpers (cert_to_inputs).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pin the coal-boiler-with-cylinder upgrade and add the `boiler_flue_type`
end-state field. A solid-fuel (coal) boiler (fuel 11, SAP code 153) on a
mains-gas street converts to a gas condensing boiler (fuel 11->26, code 102) —
the non-gas->gas path for a solid-fuel system, eligible because code 153 is in
the wet-boiler solid-fuel range 151-161 and mains gas is present.
New `boiler_flue_type` HeatingOverlay field, routed to main_heating_details[0]
and set to 2 (room-sealed/balanced) on both boiler shapes: every relodged after
lodges flue type 2, but coal's before lodged none. The field is SAP-inert (the
cascade score is unchanged by it), so it is written purely for end-state
fidelity — the overlay now represents the installed condensing boiler's flue.
Validated via the overlay-equality unit tests.
The coal after predates the user-locked "always add a cylinder thermostat when
absent" rule, so it stale-lodged thermostat 'N'; the pin corrects it to the
rule's end-state 'Y' in-test (the gas with-cylinder after got the same
correction by re-lodging). The cylinder is already 80 mm insulated, so the
jacket is skipped and only the thermostat is added; controls (2106) are
unchanged. Cascade-pinned delta 0 (SAP/CO2/PE).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two more boiler-upgrade cascade pins, validating the existing generator across
fuels and cylinder states (no source change):
- oil combi: an oil boiler (fuel 28, code 130) on a mains-gas street converts to
a gas condensing combi (fuel 28->26, code 104). Proves the non-gas -> gas
conversion gated on a mains-gas connection (ADR-0024 revised).
- already-insulated cylinder: a gas boiler heating a pre-jacketed cylinder
(type 2 / 80 mm, no thermostat) gets a new boiler + a thermostat, with the
jacket NOT re-applied. Proves the cylinder path's skip-jacket branch against a
real cert. (Sourced from an LPG re-lodgement whose fuel the Summary mapper
reads as mains gas 26 — a separate LPG fuel-mapping gap, noted in the test.)
Both pin delta 0 (SAP/CO2/PE) against the relodged after.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Extend the gas-boiler-upgrade Option to combi (no-cylinder) dwellings and add
the controls upgrade shared by both boiler shapes. A dwelling has a cylinder or
it does not, so the one `gas_boiler_upgrade` Option is shaped per dwelling:
- no cylinder -> a gas condensing combi (Table 4b code 104), no cylinder fields
touched;
- a cylinder -> a regular boiler (code 102) heating it, with the conditional
cylinder jacket/thermostat (slice 1).
Controls: bring an inadequate boiler control up to full programmer + room
thermostat + TRVs (SAP 10.2 Table 4e Group 1 code 2106). "Inadequate" = the
Group-1 codes with NO room thermostat (2101, 2102, 2107, 2108, 2109, 2111) —
these lack boiler interlock (Table 4c(2) / footnote c) p.171), so adding a room
thermostat genuinely improves SAP. Room-thermostatted (2103/2104/2105/2106/2113)
or better zone controls (2110/2112) are left unchanged — never downgraded, so
no phantom uplift. The with-cylinder cert (control 2106) is therefore untouched
and its pin still holds at delta 0.
Validated by the combi before/after re-lodgement (cert 001431, gas boiler
upgrade - no cylinder): control 2111 "TRVs and bypass" -> 2106, fan flue
False->True, SAP code 112 -> 104. Cascade-pinned delta 0 (SAP/CO2/PE). Removed
the slice-1 placeholder test asserting no boiler Option fires without a cylinder
(the combi Option now correctly fires there).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.
The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:
- Target is always a gas condensing boiler, not fuel-preserving: every after
lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
mains-gas connection; electric boilers are left alone (electrification is the
upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
+ cylinder). The calculator derives the condensing seasonal efficiency from
the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
`fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
cylinder is below 80 mm (never downgrading a better one). Both are conditional
per-dwelling components, not a frozen overlay.
Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.
Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The new gov EPC API (api.get-energy-performance-data..., Bearer auth) returns
403 "Bad authentication header" with EPC_AUTH_TOKEN but 200 with
OPEN_EPC_API_TOKEN — the token name is misleading (it is the Bearer token for
the new API, not the open-data API). Verified live against
/api/domestic/search. Unblocks the live EPC fetch in run_modelling_e2e.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>