Bump HEAD/next-slice/baseline, note the committed scripts toolkit, and add
the active "simulated case 19" section: the electric-storage-heater +
loose-jacket worksheet the user generated, what S0380.226 unblocked, and
the prioritised cluster bugs it exposed (cost (255) -334 = the +9 SAP
driver; Table 2b TF x0.9; WHS-911 storage-vs-combi routing; fabric +1.0).
Updated the "what to generate" ask to the two highest-value follow-ups
(electric room heaters; Sheltered/Adjacent RR gables).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.1. Ingestion will persist a UPRN's coordinates and planning
protections together as a write-through cache, so resolve them in a single
partition read rather than two. `SpatialReference` bundles the coordinates
(which drive the Solar fetch) and the `PlanningRestrictions` (which gate wall
insulation per ADR-0019/ADR-0020); `GeospatialRepository.spatial_for(uprn)`
returns it, and `coordinates_for`/`planning_restrictions_for` now delegate to
the one lookup.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Captures the wide-scale 2026-register study (41.8% <0.5, heating-driven
cluster table), the 7 slices shipped (S0380.219-225), the prioritised
remaining work (electric-heating clusters + worksheet-backed raises), and
the single highest-ROI worksheet to generate: an electric-storage-heater
house with a loose-jacket cylinder + a room-in-roof with Sheltered/
Adjacent gables + an extension — one document that validates the #1
accuracy cluster, pins the S0380.224 loose-jacket fix at 1e-4, closes the
gable_wall_type Table 4 raise, and exercises multi-bp fabric.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3b+3d (ADR-0019/0020). Property gains a planning_restrictions attribute
(default unrestricted); the ModellingOrchestrator threads it from the Property
through _plan_for -> _scored_candidate_groups -> _candidate_recommendations into
recommend_solid_wall, replacing the unrestricted default. run_modelling exposes
a planning_restrictions param so the offline harness can inspect restricted
properties. Integration test: a listed solid-brick dwelling that gets IWI when
unrestricted now yields no wall insulation. 145 tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The §10.7 no-water-heating default cylinder raised UnmappedSapCode for
age bands A-F (2 certs in a 2026 sample, bands B + C) because Table 29's
"A to F: 12 mm loose jacket" row wasn't plumbed — the loose-jacket
storage-loss branch didn't exist. S0380.224 added it, so this slice
completes the Table 29 lookup.
Restructure _TABLE_29_DEFAULT_CYLINDER_INSULATION_BY_AGE to carry
(cylinder_insulation_type, thickness_mm) per band — A-F → (loose jacket,
12), G/H → (factory, 25), I-M → (factory, 38) per RdSAP 10 Table 29
(PDF p.56) — and have the default read both, setting the loose-jacket
type for A-F instead of hardcoding factory. The strict-raise is retained
only for an absent / out-of-A-M age band (no Table 29 row).
Validated: certs 2211 (band B, SAP 49.8 vs lodged 52) and 3420 (band C,
11.2 vs 11) now compute. §4 + golden suite 2395 passed — the corpus
"no system" cert (age G, 25 mm factory) is unchanged. cert_to_inputs.py
pyright unchanged at 32; new test suppresses reportPrivateUsage.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3a (ADR-0020). PlanningRestrictions relocated out of the solid-wall
generator into domain/geospatial/ as the shared, Property-level value object
(three distinct flags + measure-specific blocks_external/blocks_internal).
GeospatialRepository gains a non-abstract planning_restrictions_for defaulting
to None (sources without the flags need not implement it); GeospatialS3Repository
reads conservation_status/is_listed_building/is_heritage_building from the same
Open-UPRN partition as the coordinates (legacy column names — to confirm in the
S3 deep-dive). Shared _row_for helper dedups the partition lookup.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_cylinder_storage_loss_override` returned None for any cylinder whose
cylinder_insulation_type wasn't 1 (factory), so a loose-jacket cylinder
(code 2, RdSAP 10 field 7-11) fell to the cascade's zero-storage-loss
combi/instantaneous default — its real storage loss vanished. SAP 10.2
Table 2 Note 1 gives loose jacket a SEPARATE, ~2× higher loss factor
(L = 0.005 + 1.76/(t+12.8) vs factory 0.005 + 0.55/(t+4)); the
cylinder_storage_loss_factor_table_2 helper already implements it — only
the dispatch was missing.
Fix: a `_cylinder_storage_loss_insulation_label` resolver maps the lodged
code to the Table 2 branch (1 → factory_insulated, 2 → loose_jacket;
None/0/unknown → None, keeping the conservative no-loss default). The
override and the HW storage call now route through it instead of
hardcoding "factory_insulated".
Evidence + validation: a random 2026 register sample has 22 loose-jacket
certs that over-predicted SAP by +2.29 mean (18/22 too high, 1/22 within
0.5) — the exact signature of under-counted HW storage loss. After the
fix their mean error collapses to +0.45 and 11/22 land within 0.5, with
ZERO regression across the worksheet-validated cohort (§4 + golden suite
2394 passed — no validated cert lodges loose jacket, so none shifts).
Also unblocks the §10.7 A-F no-water-heating default (next slice) which
needs the loose-jacket branch. cert_to_inputs.py pyright unchanged at 32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2e. recommend_solid_wall joins the orchestrator's fabric generator pool
(restrictions default unrestricted until slice 3 sources them); the harness
catalogue + contingencies (26%) gain external_wall_insulation /
internal_wall_insulation. run_modelling on an uninsulated solid-brick dwelling
(baseline SAP 36.6) now selects internal wall insulation into the optimised
package; the catalogue-completeness guard covers both new measure types.
Golden cohort 57/57 still error-free; IWI now fires on a real cohort cert.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2d. A flat can take IWI (its own unit) but not EWI (whole-block
coordination) — ADR-0019. _is_flat handles both ingestion representations:
the Elmhurst name form ('Flat') and the API stringified RdSAP code ('2' = Flat
per PROPERTY_TYPE_LOOKUP). Completes slice 2's eligibility surface.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2c. recommend_solid_wall takes a PlanningRestrictions value object
(defaults unrestricted): a conservation area removes the EWI Option (external
appearance), a listed or heritage building removes both EWI and IWI (protected
fabric) -> None when nothing survives (ADR-0019). Plus a guard that a cavity
wall yields no solid-wall Recommendation (it is handled by recommend_cavity
_wall). PlanningRestrictions will be sourced onto the Property from the
geospatial layer in slice 3 (ADR-0020).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
5 certs in a 2026 API sample raised `KeyError: 'rr_common_wall_area_m2'`
and were blocked from computing. Root cause: `_part_geometry`'s early
return (taken when a building part lodges no sap_floor_dimensions —
e.g. a party-wall-only or RR-only extension as bp[0]) returned only 6 of
the 9 keys the full return exposes, omitting rr_common_wall_area_m2,
rr_gable_area_m2 and cantilever_floor_area_m2. The §3.9 RR contribution
block reads geom["rr_common_wall_area_m2"] / ["rr_gable_area_m2"] for
EVERY part, so the floorless part's truncated dict raised KeyError at
heat_transmission.py:974.
Fix: the early return now exposes all 9 keys, the three RR/cantilever
geometry values defaulting to 0.0 — correct, since a part with no floor
dimensions has no derivable RR shell or cantilever (no floor area).
Pure contract-completion bug; no spec/U-value change.
Regression test pins the invariant directly: a floorless part's
_part_geometry keys must equal a with-floors part's keys. Validated: all
5 certs now compute (4 within ~2 SAP of lodged; the 5th, 8536, has a
separate residual). §4 suite 2393 passed; heat_transmission.py pyright
unchanged at 12, test file at 71.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2b. Timber frame (wall_construction=5) takes internal wall insulation but
not external (not constructable — ADR-0019), so the generator offers IWI only.
Cascade pin: the IWI Option reproduces the re-lodged timber-frame after at
abs(diff) <= 1e-4 (general Table 6 insulation-thickness bucket, not the solid-
brick documentary path).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2a. New recommend_solid_wall emits one Main-wall Recommendation carrying
External + Internal wall-insulation Options for an uninsulated (wall_insulation
_type=4) solid-brick (wall_construction=3) main wall, each priced at the heat-
loss wall area. Cascade pin: the generator's EWI and IWI Options reproduce
their respective re-lodged afters at abs(diff) <= 1e-4.
Detection keys on wall_construction code, not description (ADR-0019 note
corrected): the Elmhurst ingestion path leaves walls[].description empty, so
the code is the only cross-path signal; codes 1-5 are consistent.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of solid-wall insulation. BuildingPartOverlay gains a
wall_insulation_thickness field; the generic applicator already folds it onto
SapBuildingPart by name. With wall_insulation_type=1 (EWI) / 3 (IWI) + 100 mm,
the calculator derives the post-insulation U-value (§5.8 documentary path,
λ=0.04 default) — and for IWI also lowers the thermal-mass parameter. Two new
Elmhurst before/after cascade pins (solid-brick EWI + IWI, cert 001431)
reproduce the re-lodged after at abs(diff) <= 1e-4 across SAP/CO2/PE.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record S0380.218 shipped, bump HEAD/next-slice, note both certs are
0-residual cross-validated golden fixtures and flag the optional
Summary-path regression guard as the cheap follow-up.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Next-agent brief: fetch certs fresh from the EPC API (two new API+Summary+
worksheet triples for cross-mapper parity, plus six dashboard-flagged certs).
Flags the critical reconciliation: the user's flagged numbers don't match the
golden-fixtures cascade (0390-2954-3640 pinned +0 but flagged -6.85; 7536/2130
flags are pre-this-session), so fresh-raw-JSON-vs-curated-fixture or a
different engine must be reconciled before debugging. Documents the EPC API
fetch mechanism, the dropped-field audit method, this session's 4 fixes, and
the conventions.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Second silently-dropped field from the 2130 audit: the schema-21
SapBuildingPart never declared `wall_insulation_thermal_conductivity`, so
`from_dict` discarded it. Captured it through schema 21.0.0/21.0.1 → domain
SapBuildingPart → API mapper, and wired it into u_wall's RdSAP 10 §5.8
documentary-evidence R-value calc (both the solid-brick §5.7/§5.8 path and
the cavity-composite path), replacing the bare 0.04 λ constant with a
resolved λ.
Resolver: absent / "Unknown" → the §5.8 default 0.04 W/m·K (mineral wool /
EPS); a mapped code → its λ; an unmapped integer code RAISES so the enum is
confirmed against a worksheet rather than silently mis-factored (same
incremental-coverage discipline as the glazing-type map). Only code 1
(= the default 0.04) is mapped — the sole observed value (cert 2130 Ext1).
Zero cascade effect today: the λ path fires only for solid-brick/cavity
walls with a *measured* wall thickness, and 2130 Ext1 lodges no wall
thickness, so its conductivity is captured-but-unused; all existing §5.8
certs lodge no conductivity → 0.04 default unchanged. The point is to stop
dropping lodged data and make λ correct when a future cert exercises it.
Suite: 2523 passed (1 pre-existing TFA fail); sap10_ml 237 passed (2
pre-existing stone-formula fails). Zero new pyright errors (46=46).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Plan derives its Valuation Uplift (ADR-0018) from its baseline -> post
band jump and works+contingency cost, given one external input — the
Property's current market value (a Property Valuation, mostly absent).
`Plan.valuation` / `Plan.baseline_epc_rating` are derived like the other
headline figures; `PlanModel.from_domain` maps the £ forms to the live
plan.valuation_* columns (NULL when no value — the percentage is not
persisted on those columns). `Property.current_market_value` is the new
optional source; the orchestrator threads it onto the Plan. `run_one`
takes a `current_market_value` so the harness can value the uplift, and
the sense-check table shows the average % (always) plus the £ forms when
known.
Sourcing the current market value (upload / default) remains deferred
(ADR-0018); it is None throughout until that lands, so the columns stay
NULL at scale.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A "Pitched, sloping ceiling" roof (roof_construction code 8) lodged with
"As Built" insulation (no measured thickness → None) was wrongly routed to
RdSAP 10 Table 18 column (1) "insulation between joists or unknown". A
sloping ceiling has no joist void, so per RdSAP 10 §5.11 roof-input item
5-5 ("Sloping ceiling insulation … unknown / as built → Table 18") and
Table 18 note (b) ("Applies also to roof with sloping ceiling") it takes
column (3) — band F = 0.68, band L = 0.18 (vs col 1 0.40 / 0.16).
Discriminator is the code-8 "sloping ceiling" string only: code-5 vaulted
ceilings stay on column (1) per the 33 cohort-2 "ND" vaulted certs
(S0380.211), and the "NI"/"ND" unknown case is untouched. New
`is_pitched_sloping_ceiling` flag threaded from heat_transmission to
`u_roof`; pre-1950 bands already reach the same col (3) value (2.30) via
the mapper's thickness=0 → Table 16 row-0 override, so the new branch
carries the post-1950 bands where col 1 ≠ col 3.
Worksheet-validated by simulated case 15 (the 7536 replica): our cascade
on its Summary matches the P960 worksheet exactly — roof HLC 29.17 W/K,
cont SAP 65.04 vs 65. Re-pins golden cert 7536: roof 26.77 → 29.17, cont
SAP 69.071 → 68.924, PE -7.0776 → -6.1952, CO2 -0.1875 → -0.1639 (SAP
integer 68, resid +1 unchanged — the remaining +0.92 is a diffuse demand
under-count needing a fully-faithful worksheet). Blast radius: 7536 only.
Suite: 2388 passed, 1 skipped (main); sap10_ml 233 passed + 2 pre-existing
stone-formula failures (out of scope). Zero new pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The financial-uplift model per ADR-0018. `estimate_valuation_uplift(
current_band, target_band, current_value=None, total_cost=None)` returns
a `ValuationUplift`: band-transition uplift compounded from four broker
tables (MoneySupermarket / Lloyds per-step, Knight Frank / Rightmove
whole-jump), taking min/max/mean across the covering sources. Always a
percentage; absolute £ forms (increase at each bound + post-retrofit
value) only when a current market value is supplied; the 2x ROI cap
rescales the percentages and can only bite once a value is known. A
non-improving jump is a clean 0% no-op.
Pure function, no external dependency. Persisting it (where the value
lands) and sourcing the current market value stay deferred (ADR-0018).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Expand half of the recommendation_materials retirement (ADR-0017). A
Plan Measure installs a single Product, so thread its catalogue id end to
end — Product.id -> MeasureOption.material_id -> PlanMeasure.material_id
-> recommendation.material_id — replacing the per-material BOM child
table with one nullable column on the row. ProductPostgresRepository
reads the id from MaterialRow; the four fabric generators set it on their
Option; the orchestrator carries it onto the Plan Measure; the mirror
declares + maps the column. Optional throughout (the JSON stopgap
catalogue carries no ids -> NULL).
The multi-measure integration test now pins each persisted measure's
material_id to its seeded MaterialRow id. Migration spec (live column
must be added before this deploys; contraction is the owner's next step)
in docs/migrations/recommendation-material-id.md.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Per each cert's notes: 7536 is a glazing-U gap (S0380.97 glazing_type=2
Table 24 default vs the cert's higher lodged U on multi-age bps) — the
tractable target; 2130's SAP +1 is a PV-β cohort cascade interaction, not
a fabric line. The earlier "multi-part wall, shared cause" label was wrong.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add a CURRENT PRIORITY section: of 53 pinned golden certs, 3 have non-zero
SAP residual. 2130 (+0.85 cont) + 7536 (+0.57 cont) are real multi-part-wall
fabric over-predictions (the drive-to-zero targets, possibly one shared
cause). 0240 (-1) is architectural — the lodged 73 needs an unpreserved
2013+ pump; document the cause, do NOT re-pin (user decision).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record the £120 standing-charge fix (Table 12 note (l) + §C3.2, case 14
(351)), the corrected diagnosis (standing charge, not cost scaling — the
4.24 p/kWh heat price was already right), the double-count avoidance, and
the remaining ~7% demand over-count (SAP -2). Bump HEAD/baseline/next-slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Cert 9390 (community mains-gas boiler, API main_fuel_type=20) drew £0
standing charge → fuel cost under-counted → SAP read +4 high (71 vs 67).
Root cause: the standing-charge logic (`additional_standing_charges_gbp`)
only knows the GAS branch (`_is_gas_code`) and the off-peak-electric branch.
A heat-network community fuel is not a Table-32 gas code — EPC 20 = "mains
gas (community)" normalises to Table-32 code 20 (biomass), so
`_is_gas_code(20)` is False and the standing came out £0. The Summary path
masks this because it lodges community gas as Table-32 code 1 (ordinary
mains gas), which IS gas-recognised and already draws the £120 gas standing
— so the CH1-6 corpus was unaffected while the API path lost the charge.
Spec basis (verified against SAP 10.2 spec PDF):
- Table 12 (p.191) "Heat networks" row standing charge = £120/yr, note (k).
- Note (l): "Include half this value if only DHW is provided by a heat
network."
- §C3.2 (p.58): the full charge applies when the space heating is also a
heat network.
Worksheet-validated: simulated case 14 (community boilers + mains gas,
space + water) → worksheet (351) Additional standing charges = £120.
Fix: new `_heat_network_standing_charge_gbp(epc, main)` returns the
heat-network standing (£120 full when the space main is a heat network;
£60 when only DHW is on the network) or None otherwise. Applied at both
fuel-cost call sites, REPLACING the fuel-based `additional_standing_charges
_gbp` for heat-network mains (NOT additive) so a Summary-path community-gas
main — already £120 via the gas branch — is not double-counted to £240. The
CH1-6 community corpus stays exactly £120 (59 corpus tests pass).
9390 SAP +4 → -2 (cont 65.39 vs lodged 67): the spec-correct £120 standing
EXPOSES a separate ~7% demand over-count (also visible as PE 220 vs lodged
205) — a heat-source-efficiency-default / fabric residual, follow-up scope.
9390 is unpinned (retired P2.2 per ADR-0010 §10); helper locked by 2 unit
tests. Full suite 2386 passed, 1 skipped.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record the heat-network fuel-code collision fix (EPC 20 'mains gas
(community)' → Table-12 51), case-14 validation, and the remaining
cost-scaling gap (heat-network cost path missing 1/heat_source_eff).
Bump HEAD/next-slice; update shipped + audit tables.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Cert 9390-2722-3520 (community mains-gas boiler scheme, sap_main_heating_
code=301, main_fuel_type=20) emitted CO2 0.44 t vs lodged 2.8 t — 6.4x low.
Root cause: the EPC `main_fuel_type` enum and the SAP Table 12 / Table 32
fuel-code numbering COLLIDE in the 18-25 range. Per
`datatypes/epc/domain/epc_codes.csv` (RdSAP-Schema-17.0) EPC fuel
20 = "mains gas (community)", but Table 12/32 code 20 is a solid biomass
fuel (CO2 0.028, PE 1.046, wood-logs price). The factor lookups
(`co2_factor_kg_per_kwh` / `primary_energy_factor` / `unit_price_p_per_kwh`)
check the Table-12/32 dict FIRST, so the EPC community fuel 20 silently
returned the biomass factor instead of translating 20 -> Table 12 code 51
(community mains gas: CO2 0.210, PE 1.130, mains-gas price).
Fix: new `_heat_network_factor_fuel_code(main)` translates the EPC community
fuel to its Table-12 code via `API_FUEL_TO_TABLE_12`, but ONLY for
heat-network mains (`_is_heat_network_main`) — a genuine biomass boiler
(non-community) keeps its raw Table-12 factor. Applied at the five
heat-network factor sites: space-heating CO2 / PE / unit-price and
water-heating (WHC 901) CO2 / PE. The Summary path is unaffected (it maps
"Mains gas - community" to code 1, no collision), so the community-heating
corpus (CH1-6) is untouched.
Worksheet-validated against simulated case 14 (community boilers + mains
gas, SAP code 301): worksheet (367) CO2 factor 0.2100, (467) PE factor
1.1300 — exactly the Table-12 code-51 values the translator now reaches.
9390 CO2 0.44 -> 3.03 t (lodged 2.8; spec-correct factors over the API-only
register residual per [[feedback-worksheet-not-api-reference]]), PE 204 ->
220 (the spec-correct 1.13 factor; the prior 204≈205 match was the
collision coinciding with the register residual). 9390 is unpinned (retired
at P2.2 per ADR-0010 §10); the translator is locked by two unit tests.
REMAINING (separate follow-up): 9390 SAP +4 is a cost-side gap — the
heat-network cost path does not apply the 1/heat_source_eff (1/0.80)
scaling that the CO2/PE paths do, so community fuel cost under-counts.
Suite: 2616 passed, 1 skipped (community corpus green); the 2
test_rdsap_uvalues stone-formula failures are pre-existing (HEAD 58ff7d88).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record the community mains-gas BOILER worksheet (case 14): target (386)
heat-network CO2 factor 0.2640, distribution loss 1.49, code 301. 9390
decomposition: PE matches (204 vs 205), CO2 6.5x low (collision), SAP +4
separate cost gap.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record the roof closure (vaulted NI → Table 18 col 1 0.16, cohort-arbitrated
not the guessed 0.25), the AGENT_GUIDE suite-command gap (sap10_ml/tests/ not
run) + pre-existing stone failures, cases 11/12/13 now available, and the
fuel-20 = community-gas (Table 12 code 51) note. Thread 2 still needs a
code-301 community-boiler + mains-gas worksheet (case 13 is code-302 CHP).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Closes the Ext1 vaulted-roof over-count that S0380.209 exposed on golden
cert 0240-0200-5706. BP2 lodges roof_construction=5 (vaulted ceiling),
roof_insulation_thickness="NI" (parsed to 0), description "Pitched,
insulated (assumed)", band J. The cascade returned U=0.68 — the RdSAP 10
§5.11.4 (p.44) retrofit-50 mm "insulation at joists" row. A vaulted /
sloping ceiling has no ceiling-joist void, so that row does not apply; per
RdSAP 10 §5.11 Table 18 (p.45) it takes the column (1) age-band default
(band J = 0.16).
The arbiter is the cohort, not the spec text alone: 33 cohort-2 certs
lodge "ND" (thickness None) vaulted roofs (roof_construction=5, band D)
that already pin to their dr87 worksheets at U=0.40 = Table 18 col (1) by
falling through the age-band default. 0240's only difference is the "NI"
sentinel (insulation present, unknown thickness) which uniquely hit the
0.68 override. (The S0380.209 note's predicted "cont ≈ 72.31" assumed a
col-3 0.25 value; the cohort's ND vaulted roofs disprove that — they use
col (1), so 0240 lands at cont 72.4617.)
Implementation: new `u_roof(is_sloping_ceiling=...)` flag, threaded from
heat_transmission for roof_construction_type containing "sloping ceiling"
(code 8) or "vaulted" (code 5). It fires only for the NI case
(thickness 0 + "insulated (assumed)"), routing to the col (1) age-band
default; the "ND"/None path is untouched (already col 1) and a NORMAL
pitched-with-loft roof still takes the §5.11.4 50 mm row (flag defaults
False). roof 76.93 → ~68 W/K → 0240 PE +5.5044 → +1.5181, CO2 +0.2757 →
+0.0728 (SAP integer 72 unchanged — the true value; lodged 73 needs the
unpreserved 2013+ pump).
Also corrects test_u_wall_cavity_as_built_partial_insulation_routes_to_
filled_cavity_row → ..._routes_to_as_built_row: a missed S0380.210
follow-up. That test (in domain/sap10_ml/tests/, which the AGENT_GUIDE §4
suite command does not run) asserted the pre-S0380.210 "partial insulation
→ filled" behavior on legacy-map parity, not worksheet evidence; S0380.210
corrected it to the as-built row per RdSAP 10 Table 6 + golden cert 0390's
four-metric closure.
Suite: 2614 passed, 1 skipped; the 2 remaining failures in
test_rdsap_uvalues.py (stone §5.6 thin-wall formula vs Table-6 1.7 cap)
are pre-existing (fail at HEAD 58ff7d88, before this branch's work).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PortfolioGoal is domain vocabulary (a Scenario's goal — legacy planning branches
on PortfolioGoal.INCREASING_EPC), so it belongs in domain/ co-located with
scenario.py, mirroring how domain/epc/wall_type.py holds an enum that
infrastructure/ imports. This lets the consolidated ScenarioModel (next slice)
source the goal enum from domain without an infra→backend dependency.
portfolio.py keeps a re-export so every existing
`from ...portfolio import PortfolioGoal` caller is unaffected.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Update the mapper-bugs handover: Thread 3 closed via the cavity
"partial insulation (assumed)" → "Cavity as built" routing fix; record
the latent open question about the unvalidated "insulated (assumed)" →
filled-cavity test (slice S-B25). Bump HEAD/baseline/next-slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Golden cert 0390-2954-3640 (detached, TFA 360, age F) carried a +7 SAP /
-28 kWh/m² PE residual the audit attributed to a demand-side fabric gap.
Walking the §3 cascade localised it to the Main wall: lodged
wall_construction=4 (cavity), wall_insulation_type=4 (as-built / assumed),
description "Cavity wall, as built, partial insulation (assumed)". The
cascade mis-routed it to the Table 6 "Filled cavity" row (band F = 0.40)
because `_described_as_insulated` matches the "partial insulation"
substring.
RdSAP 10 Specification (10-06-2025) Table 6 — Wall U-values, England
distinguishes two cavity rows:
"Cavity as built" A-E 1.5, F 1.0, G 0.60, H 0.60, I 0.45, J 0.35, ...
"Filled cavity" A-E 0.7, F 0.40, G 0.35, H 0.35, I 0.45†, J 0.35†, ...
An "as built ... partial insulation (assumed)" cavity is the as-built
partial fill of the age band, NOT a retrofit cavity fill (a genuine fill
lodges the distinct "Cavity wall, filled cavity", wall_insulation_type=2).
It therefore routes to "Cavity as built" (band F = 1.0), mirroring the
worksheet-validated solid-brick rule in S0380.209 (cases 9/10: "as built,
insulated (assumed)" → as-built age-band row, not retrofit).
New `_cavity_described_as_filled` predicate is used only in u_wall's
cavity filled-row branch; it excludes the "partial insulation" substring
while keeping "insulated (assumed)" → filled (the unrelated, separately
asserted test_cavity_as_built_insulated_assumed_uses_filled_cavity_row is
unchanged). The shared `_described_as_insulated` (also consumed by the
roof/floor paths) is left untouched.
Wall HLC +53.6 W/K (U 0.40 → 1.0 over ~268 m²) lifts all four metrics
together — the signature of a real fabric bug, not a tuned offset:
SAP +7 → +0
PE -27.9745 → +0.5281 kWh/m²
CO2 -2.7134 → -0.1189 t/yr
Bands I-M are unaffected (the two rows coincide per the † footnote), so
golden certs 0535 (band M) / 7536 (band L) with "insulated (assumed)"
cavities continue to pin at 0. Full suite 2384 passed, 1 skipped.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Records post-S0380.209 state: 0240 verdict (true SAP 72, register 73 = unpreserved
2013+ pump, proven 0=Unknown via 13 pairs), and three open threads — roof Ext1
"insulated (assumed)" U over-count (needs case 11 worksheet), community fuel-code
collision (API 18-25 vs Table-12 biomass 18-25; cert 9390 CO2 6x low; needs 9390
worksheet), and 0390 +7 demand-side gap. Plus the audit table of all 5 non-zero-SAP
golden certs.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The EPC renders a recent-band as-built wall as "<material>, as built,
insulated (assumed)". The API mapper populates epc.walls with that string,
and heat_transmission's wall_ins_present gate keyed off the "insulated"
substring → routed the wall to the RdSAP 50 mm "insulation of unknown
thickness" bucket (e.g. sandstone band J U=0.25) instead of the as-built
age-band row (U=0.35).
Per RdSAP 10 Table 8/9 footnote the 50 mm row applies ONLY when insulation
is "known to have been increased subsequently (otherwise 'as built'
applies)". An "as built ... (assumed)" description is the EPC's age-band
assumption — it only renders on RECENT bands (an old band renders "no
insulation (assumed)"), so the as-built row applies. Genuine retrofit is
signalled by wall_insulation_type (External/Internal/Filled), which the
gate still checks independently.
Worksheet-validated by two new Elmhurst worksheets, both As Built band J:
- simulated case 9: sandstone → (29a) U 0.35
- simulated case 10: solid brick → (29a) U 0.35
both the as-built row, NOT 50 mm (0.25).
Fix: restrict the description-based gate to genuine retrofit via the new
local `_described_as_retrofit_insulated` (excludes "as built"/"(assumed)").
The cavity filled-row routing inside `u_wall` (which uses
`_described_as_insulated` directly) is untouched — the 3 cavity API certs
(0390/0535/7536) are unaffected.
test_heat_transmission: the old `..._uses_50mm_row` test asserted 50 mm via
an IMPOSSIBLE band-B + "insulated (assumed)" combination; corrected to a
valid recent-band (J) scenario asserting the as-built row (35 W/K).
Golden 0240: walls 24.45 → 34.23 W/K (U 0.25 → 0.35). SAP integer 72
unchanged; PE residual re-pinned +1.8687 → +5.5044, CO2 +0.0907 → +0.2757.
This spec-correct fix REMOVED the wall under-count that was masking the
Ext1 vaulted-roof over-count (cascade U 0.68 via the same "insulated
(assumed)" description vs case-9 sloping-ceiling 0.25) — that roof
over-count is the next slice; fixing both lands SAP cont ≈ 72.31 (=
Elmhurst case 9).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_plan_for` now scores the baseline + every cumulative prefix once
(`cascade_scores`, best-practice order) and reuses those Scores for both the
role-3 marginal attribution and a per-measure bill cascade: bill each prefix at
one Fuel Rates snapshot and take consecutive Bill deltas as each measure's
marginal delivered-kWh and £ saving. Saving is signed (ventilation is
negative) and telescopes exactly to the Plan headline savings, because the
Plan's baseline/post Bills are now the same cascade endpoints (`bills[0]` /
`bills[-1]`) — which also drops the redundant standalone baseline `calculate`.
`recommendation.kwh_savings` / `energy_cost_savings` are filled from these.
Adds `Bill.total_consumption_kwh` (shared by Plan + the orchestrator). Pinned
end-to-end on the real calculator: Σ per-measure savings == the Plan totals
(ADR-0014 amendment).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`PlanMeasure` grows optional `kwh_savings` (delivered energy) and
`energy_cost_savings` (£) — its slice of the telescoping bill cascade, signed
so positive is a saving and `None` until billing runs. `RecommendationRow`
declares the matching live `recommendation.kwh_savings` /
`energy_cost_savings` columns and maps them in `from_domain` (None → NULL).
The vestigial `recommendation.energy_savings` stays undeclared (legacy = 0).
No FE migration — the columns already exist on the live table (ADR-0014 / 0017).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pull the cumulative-prefix scoring out of `marginal_impacts` into a reusable
`cascade_scores(scorer, baseline, overlays) -> list[Score]` (index 0 the
baseline, one calculator run per prefix) plus a pure `marginals_from_scores`.
Each Score carries its SapResult, so the next slice's telescoping per-measure
bill cascade can re-bill the same prefixes the role-3 attribution already
scores — no extra `calculate` calls (ADR-0014 / ADR-0016). `marginal_impacts`
now delegates; behaviour unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Plan gains optional baseline_bill / post_bill (the Bills derived for the
unmodified and post-package end-states at one Fuel Rates snapshot) and derives
the four plan-level columns: post_energy_bill (post total), energy_bill_savings
(baseline - post), post_energy_consumption (Σ post section kWh), and
energy_consumption_savings (baseline - post delivered kWh). All return None until
billing runs (persisted as NULL), so existing Plan construction and the
not-yet-wired orchestrator stay green. Plan-level only; per-measure savings are a
later slice (ADR-0014 amendment).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Score gains sap_result: Optional[SapResult], populated by PackageScorer with the
calculator output its headline figures came from. This lets the Modelling stage
price the post-package (and baseline) end-state via Bill Derivation reusing a
SapResult already computed by the optimiser's re-score / the orchestrator's
baseline score — no second calculate (ADR-0014 amendment). The optimiser reads
only sap_continuous, so it stays domain-agnostic and the stub scorers (which omit
sap_result) are unaffected — all optimiser tests pass unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Bill / EnergyBreakdown / BillDerivation / sap_fuel were under
domain/property_baseline/ only because Baseline was built first. The Modelling
stage now needs them too, so move them (and their tests) to a neutral
domain/billing/ — Fuel/FuelRates already live in the shared domain/fuel_rates/.
Avoids a modelling -> property_baseline cross-stage import and a package name
that wrongly implies ownership (ADR-0011, ADR-0014 amendment). Pure git mv +
import rewrite across 10 files; 40 billing/baseline/repo tests pass, pyright
strict clean. CONTEXT.md Bill Derivation location updated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds a "build THIS in Elmhurst" specification — dwelling, dual condensing
oil-combi (code 130) heating, combi/no-cylinder DHW (Table 3a keep-hot
600), per-element fabric W/K targets, room-in-roof gables, the 5 vertical
+ 6 roof-of-room windows, lighting (8 LED), no PV — so a generated
worksheet reproduces cert 0240 as closely as possible. Flags the three
load-bearing differences vs case 6 (combi code 130, no cylinder, boiler
interlock PRESENT → no -5pp) that the new worksheet must capture.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Records why case 6 (worksheet-validated dual-oil archetype) did not close
0240's residual: 0240 is API-only with an INTEGER-rounded register target
(PE 122, CO2 6.0), so 0 residual at 1e-4 is not well-posed without a
worksheet. 0240's unvalidated path vs case 6 is the condensing-combi
(code 130) + no-cylinder HW (Table 3a keep-hot 600 kWh) — case 6 used a
regular boiler + cylinder. Recommends generating an exact-0240 worksheet
(or a 'case 7' = case 6 with the combi swapped in) to get a 1e-4 target.
Notes the lodged RHI water_heating 2842.82 already matches the cascade
HW output exactly (HW demand is right; any residual is in efficiency).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The warm-start (and max-gain fallback) now price each forced Measure Dependency
the candidate triggers, not just inject it afterwards: optimise/optimise_min_cost
fold dependencies into each candidate's cost+gain via _augmented_cost_gain, and
optimise_package scores each dependency's true role-1 signal (_with_role1_signals)
instead of the 0.0 placeholder. This stops the min-cost objective (i) ignoring the
~£900 a wall drags in (a wall-free package reaching target can be cheaper) and
(ii) picking a small-gain wall whose mandatory ventilation (down to -5 SAP) makes
it net-negative, which repair cannot un-pick.
Budget is now a hard envelope: the constraint applies to the augmented (measure +
its ventilation) cost, so a wall that fits alone but whose ventilation would bust
the budget is DROPPED rather than forced over budget. This reverses the earlier
'forced regardless of budget' call (which made sense when selection was
ventilation-blind). Safety invariant intact — presence still injected on every
path; we just never recommend a wall we can't afford to ventilate. ADR-0016
amendment updated. 94 modelling+orchestration tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix D §D2.1(2) Equation D1 blends the monthly water-heater
efficiency by the ratio of the boiler's space-heating load to its water
load. On a dual-main cert the DHW boiler does only its OWN share of space
heating ((204) for Main 1, (205) for Main 2), but the cascade fed Eq D1
the dwelling total ((202) = 1 − secondary). That over-weighted η_winter
and under-stated HW fuel — simulated case 6 (Main 1 serves DHW + 51% of
space heat) was HW −78 kWh vs the worksheet.
New `_water_heating_main_space_fraction` returns the DHW main's total-
space share via `_water_heating_main` (WHC-901 → Main 1 (204); WHC-914 →
Main 2 (205)); single-main / WHC-901 single systems get (202) = 1 −
(201), so they are unchanged. Case 6 (219) HW now 4902.8601 EXACT.
With S0380.205 (demand exact), case 6 now closes to 1e-4 on EVERY metric:
SAP cont 71.6597, ECF 2.0316, cost 1162.5374, (211)+(213) 14736.9564,
(219) 4902.8601, (231) 356, (232) 357.6571, CO2 5953.6679 (rating) /
4895.2137 (demand).
Re-pin: 0240 (dual combi, WHC 901, Main 1 51%) HW rises slightly → PE
+1.6893 → +1.8687, CO2 +0.0815 → +0.0907 (SAP 72 unchanged). Single-main
certs unchanged (2360 pass + 0 fail).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
When two main heating systems heat different parts of a dwelling, SAP
10.2 §7 (PDF p.186) adapts the mean-internal-temperature calculation:
- Table 9b weighted responsiveness: R = (1−(203))·R_sys1 + (203)·R_sys2.
- Rest-of-dwelling temperature (90)m = weighted average of T2 computed
under EACH system's control schedule, weights (203)/[1−(91)] for sys2
and [1−(203)−(91)]/[1−(91)] for sys1 (or sys2's control alone when
(203) ≥ 1−(91)).
The cascade used Main 1's control + R=1.0 for the whole dwelling,
over-stating MIT by +0.037 °C on simulated case 6 (Main 1 radiators/2106
type 2 living + Main 2 underfloor/2110 type 3 elsewhere, R 1.0/0.75). That
inflated (97) heat loss by ~11 W → demand +61 kWh/yr.
`mean_internal_temperature_monthly` gains `main_2_control_type`,
`main_2_fraction`, `main_2_responsiveness`; cert_to_inputs derives them
from the second main detail (gated on main_heating_fraction > 0, so
single-main / DHW-only second mains pass the defaults → unchanged).
Case 6: (87) living, (90) elsewhere, (98c) demand 11991.96 and per-system
fuel (211)=7741.6458 / (213)=6995.3106 all match the worksheet to 1e-4.
Re-pin: golden 0240 (same 2106/2110 archetype, API-only) — PE +2.1519 →
+1.6893, CO2 +0.1051 → +0.0815 (both closer to zero; SAP 72 unchanged).
Single-main certs unchanged (2360 pass + 0 fail).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Rewire the objective per the ADR-0016 amendment. With a target_sap (Increasing
EPC): warm-start optimise_min_cost (cheapest package reaching target_gain =
target_sap - baseline within budget) -> inject dependencies -> re-score ->
repair toward target; if the warm-start is infeasible or the repaired package
still falls short on the true score, fall back to max-gain-within-budget (best
effort). Without a target_sap: max-gain (unchanged). The min-cost objective
stops at the target without overshooting into a higher band; surplus budget is
left unspent. Extracted _max_gain_package (no-target path + fallback) and
_repair_to_target (inject + re-score + greedy repair). Dependency injection and
the repair loop are preserved; all prior optimiser + dependency tests pass
unchanged. Ventilation-aware *selection* is the next slice; injection is still
post-warm-start here.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Exact-enumeration sibling to optimise(): pick <=1 option per group to minimise
total cost subject to total gain >= target_gain and cost <= budget (None =
unconstrained). Ties broken toward higher gain ('recommend more'). Returns None
when no package within budget reaches the target (caller falls back to
max-gain); a non-positive target is met by the empty package. This is the
warm-start objective for an Increasing EPC goal per the ADR-0016 amendment
(least-cost-to-target, not max-gain). Dependency-blind for now; ventilation-aware
selection lands in a later slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A rooflight deducts from the gross area of the roof element it pierces
(RdSAP 10 §3.7, PDF p.19). A "Roof of Room" rooflight (window_wall_type=4
/ site-notes "Roof of Room") sits on the room-in-roof sloped ceiling, so
its area must deduct from the §3.10.1 RR residual roof — not the flat /
loft external roof.
The cascade deducted every rooflight from the regular roof (heat_
transmission line 814). Simulated case 6's worksheet is the first
worksheet evidence for "Roof of Room" rooflight billing: "Roof room Main
remaining area" net 55.54 = gross 61.73 − 6.19 rooflights (U_RR=0.30),
while "External roof Main" 14.52 carries no opening. New
`_bp_rr_roof_absorbs_rooflight` routes the rooflight area to the RR roof
(simplified A_RR_final or detailed §3.10.1 residual) ONLY when the BP's
RR contributes such a shell AND lodges no explicit roof surface (slope /
flat_ceiling / stud_wall). Case 6 roof (30) 20.2284 → 19.0523 EXACT;
demand gap +153 → +61 kWh/yr.
Preserved: certs 000565 (Ext2 stud walls) and 000516 (slopes) lodge
explicit roof surfaces → rooflight keeps deducting from the regular roof
(their 1e-4 worksheet pins hold). Simplified Type 1 RR is excluded too.
Re-pin (uniform spec application per [[feedback-software-no-special-
handling]] + worksheet-is-truth): API certs 6035 and 0240 are detailed-RR
gables-only like case 6 (no worksheet of their own for rooflights), so
their "Roof of Room" rooflights now deduct from the RR residual too. This
SUPERSEDES the unvalidated S0380.198 "deduct from loft" assumption.
- 6035: roof 78.0648 → 73.9176; the previously-"unexplained" +1.37 PE
residual COLLAPSES to -0.14 (CO2 -0.0004 → -0.0362; SAP exact 70) —
strong corroboration the rooflight-on-RR treatment is correct.
- 0240: PE +2.5812 → +2.1519, CO2 +0.1269 → +0.1051 (SAP 72 unchanged).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>