Flat per-dwelling decommission price (sample_catalogue \£250) + 0.25 contingency
(covers unknown heater count / hard-wired-vs-plugged / repaint extent). The JSON
repo joins the contingency from config, proven by the new repo test. No composite
Products machinery — a lodged secondary is one roughly-fixed job, not room-scaled.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the system tune-up to the heating Recommendation: keep the existing wet
boiler but install better heating controls and fix the cylinder. Two competing
Options (the Optimiser picks <=1 across the whole heating rec) per the user's
two best control end-states:
- system_tune_up — standard controls (programmer + room thermostat +
TRVs, SAP 10.2 Table 4e code 2106)
- system_tune_up_zoned — time-and-temperature zone control (code 2110, type 3):
more SAP uplift for more cost
Both keep the boiler (no fuel / SAP code / flue change), set the control
ABSOLUTELY to their end-state, and apply the conditional cylinder fixes (an
80 mm jacket when under-insulated, a thermostat when absent — only when a
cylinder exists). Each control option is offered only when it genuinely improves
the existing control — standard is skipped when the control is already 2106 /
2110 / 2112, zone when already 2110 / 2112 — so neither is ever a downgrade or a
no-op.
Validated against the Elmhurst "system tune up" re-lodgements (cert 001431):
nine befores spanning controls 2101-2113 all converge to the two common afters,
proving the control overlay is absolute. The cascade pin is parametrised over
two starting controls (2101 "no control" + 2113 "room thermostat and TRVs") x
both afters, delta 0 (SAP/CO2/PE).
Wires the two MeasureTypes through contingencies (0.15), the offline catalogue
(500 / 900), the catalogue-coverage list, the report triggers, and the ARA
first-run seed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.
The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:
- Target is always a gas condensing boiler, not fuel-preserving: every after
lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
mains-gas connection; electric boilers are left alone (electrification is the
upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
+ cylinder). The calculator derives the condensing seasonal efficiency from
the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
`fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
cylinder is below 80 mm (never downgrading a better one). Both are conditional
per-dwelling components, not a frozen overlay.
Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.
Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Revives the local recommendation-inspection flow for specific Properties.
`scripts/run_modelling_e2e.py` reads each Property's UPRN from the DB
(read-only), fetches the latest EPC live from the gov EPC API by UPRN, runs the
Modelling stage in memory (all Generators → Optimiser → costed, attributed
Plan), and prints a per-Property plan table + writes a Markdown/CSV summary.
Persists nothing — purely for inspection.
The local DB's Properties have no linked ingested EPC (epc_property.property_id
is NULL for all rows; Ingestion's source clients are stubbed, #1136), so the
EPC must be fetched inline rather than read back. Builds the connection from the
`DB_*` env vars in backend/.env and the EPC token from `EPC_AUTH_TOKEN`.
Threads optional solar insights through harness `run_modelling` (so Solar PV
Options can fire once coordinates are wired) and adds the `solar_pv` catalogue
row. Solar + planning restrictions + DB persistence are noted follow-ups.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_heating now receives planning_restrictions in the orchestrator (the
ASHP planning gate); the ASHP bundle joins the free candidate pool for every
house/bungalow. Catalogue + contingency (legacy 0.25) gain air_source_heat_pump;
report.py _triggers_for explains the ASHP trigger; the harness forcing test
covers it. Integration tests seed an air_source_heat_pump MaterialRow (ASHP
fires on every house, the broadest trigger yet). NB the optimiser correctly does
NOT select ASHP for an EPC-band goal — gas->electric does not improve the SAP
cost-rating; ASHP is a CO2/PE measure, selectable once non-EPC goals land. ASHP
bundle COMPLETE (S5-S7). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_heating joins the free candidate pool in _candidate_recommendations;
the HHR storage bundle reaches the optimised package for an electric/off-gas
dwelling. Catalogue + contingency (legacy 0.10) gain
high_heat_retention_storage_heaters; report.py _triggers_for explains the
heating trigger (electric/off-gas main); the harness _GENERATOR_MEASURE_TYPES
forcing test covers it. ASHP + boiler bundles still to come. ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the lighting generator (ADR-0023): run recommend_lighting in
_candidate_recommendations (no planning gate). Price low_energy_lighting in the
offline catalogue + contingency table (0.26, the legacy rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both. A run_modelling test pins
the wiring end-to-end (an incandescent-lit dwelling gets the LED upgrade in the
optimised package).
Downstream updates, all because lighting now fires on any cert with non-LED
bulbs: report.py gains the low_energy_lighting trigger (the non-LED counts); the
two golden-cert report tests and the multi-measure integration test now expect
low_energy_lighting alongside the fabric measures (the sample/golden EPCs lodge
low-energy-unknown bulbs); first-run integration seeds a low_energy_lighting
MaterialRow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the glazing generator (ADR-0022): run recommend_glazing in
_candidate_recommendations, threading the Property's PlanningRestrictions so a
protected dwelling is offered secondary glazing instead of double (mirrors
recommend_solid_wall). Price both Measure Types in the offline catalogue
(double £600/window, secondary £510 -- the legacy 0.85x scaling) and the
contingency table (0.15, the legacy windows_glazing rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both entries exist.
run_modelling tests pin the wiring end-to-end on an all-single-glazed dwelling:
double when unrestricted, secondary when listed. The first-run integration test
seeds a double_glazing Product because its lodged EPC has a single-glazed
window. _single_glazed_epc() deep-copies build_epc() (which shares its window
objects) so the mutation can't leak into other tests' baselines.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 (ADR-0021). The roof dispatcher can now emit sloping_ceiling_insulation
and flat_roof_insulation, so wire both into contingencies and the sample
catalogue; the forcing-function test now asserts every generator measure type
is both priced and has a contingency rate, so an offline/live run over a
sloping or flat roof never dies on a missing entry.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2e. recommend_solid_wall joins the orchestrator's fabric generator pool
(restrictions default unrestricted until slice 3 sources them); the harness
catalogue + contingencies (26%) gain external_wall_insulation /
internal_wall_insulation. run_modelling on an uninsulated solid-brick dwelling
(baseline SAP 36.6) now selects internal wall insulation into the optimised
package; the catalogue-completeness guard covers both new measure types.
Golden cohort 57/57 still error-free; IWI now fires on a real cohort cert.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two fixes that unblock offline, no-database inspection over an arbitrary
EPC dump:
- Complete the harness sample catalogue with loft_insulation and
solid_floor_insulation — the four fabric generators can emit five
Measure Types, but the catalogue priced only three, so an offline run
on a property with an uninsulated loft or solid floor raised mid-run.
A new test pins the catalogue to cover every generator Measure Type.
- Add `run_modelling(epc, ...)` — runs ONLY the Modelling stage (no
Ingestion / Baseline), so it needs no lodged recorded-performance / RHI
and inspects recommendations on any calculator-scorable EPC. `run_one`
(full pipeline) stays for when you want Baseline too.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3. `harness.console.run_one(epc, goal_band=...)` wires the full
AraFirstRunPipeline against in-memory fakes — no Postgres, no network —
runs one property, prints the sense-check table, and returns the Plan
for interactive poking from a REPL at the worktree root. Defaults to the
committed harness sample catalogue.
Refactors the slice-1 integration test to delegate to run_one (dropping
~70 lines of duplicated wiring + the now-unused test catalogue fixture),
so it exercises the shipped entrypoint rather than a parallel copy. The
new console test covers run_one's print/return contract.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-04 08:14:14 +00:00
Renamed from tests/orchestration/fixtures/product_catalogue.json (Browse further)