Addresses PR #1498 review:
- A per-file read failure (missing/deleted object, or a bucket the role can't
reach) is now a SkippedDocument(reason=unreadable), not a whole-run abort;
an all-unreadable selection still fails (no empty package). Best-effort on
the read path (ADR-0060).
- Each ZIP member is streamed to a temp file (S3DocumentDownloader.download,
boto download_file) and added from disk, so a single multi-GB member never
hits the heap — the 'never held whole in memory' claim is now true.
- The 409 double-submit guard is DB-arbitrated: the sub_task insert is
conditional on the task having none, so a race creates only one.
- Local env gets a placeholder recipient email so the route is exercisable.
- PackageEntry carries landlord_property_id so a read failure can be reported.
- TODO noting the UploadedFile.s3_upload_timestamp typing fix.
Two new tests: per-file read failure skips-and-reports; address fallback flows
to the folder name.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Pins the best-effort contract (ADR-0060) delivered with the tracer — no red
phase; discriminating: a strict impl would fail the run or omit the report.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
EpcSource widens to "expired" (ADR-0054; the column is TEXT — no
migration). "predicted"/"expired" form one slot family: _slot_sources
routes every slot read and slot-clearing delete through the family, so a
re-ingestion flipping the flavour replaces the row instead of stranding
its sibling. FakeEpcRepo mirrors the family.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Sizing selects the aroTHERM plus rung nearest PSR ~0.8 (0.8 x design heat
loss) — the Appendix-N efficiency peak, reproducing the pump a real
installer fits — rather than the MCS PSR>=1.0 capacity target, which
oversizes. Validated against the relodged Elmhurst ASHP cert (delta 0
held at the 5 kW Vaillant); the two self-snapshot pins re-pin to their
correctly-sized larger pumps, and the orchestrator/harness thread the
calculator's design heat loss so production sizes to the dwelling. Manual
SapResult test stubs carry the new design_heat_loss_kw field.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The solid-brick LPG fixture (main_fuel_type=27, gas_connection_available=True)
was previously excluded from HHRSH by the mains_gas bug. After the fix it is
correctly offered HHRSH, so the integration test's product catalogue and
assertion are updated to match.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The PropertyBaselineOrchestrator now reads no Lodged Performance off a predicted
Property's neighbour-synthesised EPC: lodged is None when source_path is
'predicted', so no phantom lodged figure is manufactured. The Effective half is
unchanged. Rebaseliner port + PropertyBaselinePerformance.lodged widen to
Optional; the pristine-cert paths assert non-None (lodged is None only for a
predicted Property, which is always physical_state_changed).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add Property.physical_state_changed (true on Site Notes / Landlord Overrides
/ Prediction — trigger (b)/(c)) and pass it from the
PropertyBaselineOrchestrator into the Rebaseliner. So an overridden or
predicted SAP>=10.2 property now stores calc(effective) as its Effective
baseline instead of echoing the lodged headline — closing the "81 in the DB"
divergence between the displayed baseline and the modelled plan.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The fixture lodges is_exposed_floor=True, which was silently dropped on
save->reload before this branch — so the orchestrator (reads the DB) modelled
the floor as not-exposed. Now it round-trips, the exposed floor is honoured,
and the ASHP-led max-gain fallback on this gas dwelling is bill-neutral
(marginally negative) rather than bill-positive: large energy saving, but the
gas->electricity fuel switch offsets the GBP saving. Same optimal package,
same telescoping; only the bill-savings sign assumption changed.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Even after batching the data writes, the handler still wrote to the DB per
property through the orchestrator's SubTask bookkeeping: create + start +
complete each self-committed, and _cascade re-listed every sibling and re-saved
the parent on every transition — ~5 writes per property plus an O(N^2) cascade.
- TaskOrchestrator.run_subtasks: create all children in one INSERT, run each
(failures isolated per child), then persist all terminal states in one bulk
save and cascade the parent once. Children go WAITING -> terminal; the
transient IN_PROGRESS row is never written.
- SubTaskRepository.create_many / save_many (bulk INSERT / bulk fetch + update).
- _cascade short-circuits when the Task is already FAILED (terminal) — skips the
sibling roll-up entirely.
- modelling_e2e handler fans out via run_subtasks instead of per-property
create_child_subtask + run_subtask.
Per N-property batch the SubTask bookkeeping drops from ~5N writes + an O(N^2)
cascade to ~2 writes + 1 cascade.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
16 modelling_e2e properties failed with "Effective EPC is missing
renewable_heat_incentive; cannot read baseline space-heating / hot-water kWh".
Baseline runs for predicted properties too (ADR-0031), reading space/water-
heating kWh off the EPC's lodged RHI block. Predicted EPCs deep-copy a neighbour
template that may carry no RHI, so `_require_rhi` hard-failed the whole subtask.
Fix: when the EPC has no RHI, fall back to the property's OWN computed figures
from the scored SapResult (space_heating_kwh_per_yr / hot_water_kwh_per_yr) —
more representative than a neighbour's lodged numbers. Only when there is also no
SapResult (the rebaseliner scored nothing) is there genuinely no demand to
record, and we still fail noisily. Lodged certs are unchanged (RHI still wins).
Regression tests: fallback-to-computed, and the no-RHI/no-result raise.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>