Locks the gate edges — a lodged pitched loft below 270mm is recommended, a
loft at 270mm is left alone, and the 'Nmm+' form ('300mm+') parses to its
number and stays ineligible. These passed on arrival (they fell out of the
numeric-parse gate added in the previous commit); pinned as regression guards.
ADR-0063.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
A lodged numeric loft depth below the 270mm building-regs compliance gate is
now eligible (topped up to the 300mm install depth), regardless of whether the
roof type is lodged, since a measured depth is a positive statement of a real
loft. Sentinels keep their ADR-0047 resolution. Fixes property 724702 (50mm
loft) which previously returned no recommendation. ADR-0063.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The roof generator offered loft insulation only when genuinely uninsulated
(ADR-0021), so a loft with a shallow lodged depth (e.g. 724702's 50mm) got
nothing and never entered the optimiser pool. Grilled with Khalim: the loft
branch becomes eligible when the lodged depth is a known numeric value below
the 270mm building-regs compliance gate, topped up to the 300mm install depth.
Numeric-lodged-depths only; sentinels keep their ADR-0047 resolution. Loft
branch only. CONTEXT 'Roof Insulation Eligibility' updated to match.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Properties 741843/741872 (uprns 100060714155/100021944594) failed
modelling_e2e subtasks 6ac7841a-9338-4efe-97e5-7e0d19b3055d and
c5450f03-5b0d-4068-a3b3-d1470bc0af57 with a bare StopIteration: their
SAP-Schema-15.0 (2011-era LIG-lodged) certs identify the main dwelling's
building part as "Main building" rather than "Main Dwelling", so
from_api_string fell to OTHER and left the property with no MAIN part —
crashing wall_recommendation.py's unguarded next(...).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Thread the UPRN the PashubService has already resolved for a job into the
PasHub site-notes mapper so the EpcPropertyData aggregate is born with its
uprn set, and the existing save_epc_property_data path persists it.
- EpcPropertyDataMapper.from_site_notes gains uprn: Optional[int] = None and
sets it unconditionally (site notes never carry a UPRN natively).
- parse_site_notes_pdf / _parse_pashub forward the uprn; the Elmhurst branch
is untouched.
- PashubService coerces uprn str -> int in one place, carries it on the
internal upload record, and passes it into parse_site_notes_pdf.
- No new lookups; jobs with no known UPRN still persist null, unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The prior commit derived a Python bool (`cylinder_size != 1`), but
`from_rdsap_schema_17_1` reads the field via `schema.has_hot_water_cylinder
== "true"` — every real 15.0/16.x fixture lodges the lowercase string
"true"/"false", not a JSON boolean. A bare bool compares False against
that string check either way, so the derivation silently mapped every
cylinder-present cert to has_hot_water_cylinder=False too.
Caught by the requested true-branch test (mutating sap_16_2.json, which
lodges cylinder_size=2/has_hot_water_cylinder="true", to omit the field)
— it failed under the original bool-typed fix. Now emits "true"/"false"
strings to match the lodged convention.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Task b9fcd354-2a33-4fc4-a64e-388c060a055c (portfolio 824 / scenario 1278)
also failed property_id 749229 (UPRN 100010349400) with "RdSapSchema17_1:
missing required field 'has_hot_water_cylinder'". Cert
9568-3034-6211-6089-5960 (SAP-Schema-15.0) lodges `sap_heating.cylinder_size`
but omits the separate top-level `has_hot_water_cylinder` boolean
RdSapSchema17_1 also requires.
Unlike `multiple_glazed_proportion` (deliberately left un-defaulted a few
lines above — a prior guessed default regressed the accuracy gate),
`cylinder_size` isn't a proxy needing inference: RdSAP 10 Table 28 defines
code 1 as "no cylinder" — literally the same fact `has_hot_water_cylinder`
encodes. Confirmed 1:1 across every real 15.0/16.x fixture that lodges both
fields (cylinder_size == 1 <-> false, every other code <-> true).
Added to the shared `_normalize_sap_schema_16_x`, so it covers the whole
15.0/16.0/16.1/16.2/16.3 reduced-field family, not just 15.0.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Task b9fcd354-2a33-4fc4-a64e-388c060a055c (portfolio 824 / scenario 1278)
still failed 5 of 128 batches with NotNullViolation on
epc_building_part.construction_age_band even after the SAP-Schema-15.0
mapper landed (PR #1531). Cert 8169-6926-5310-0447-8996 (UPRN
100010344955, SAP-Schema-15.0) lodges a bare alternative-wall record
(wall_area/wall_construction/wall_insulation_type, no identifier, age
band, or floor dimensions) as a second sap_building_parts element rather
than under a distinct sap_alternative_wall_1 key. RdSapSchema17_1 (which
the 15.0/16.x reduced-field mappers delegate to) has no alt-wall slot to
route it to, so it persisted as a phantom building part with a null age
band.
_drop_building_parts_without_age_band already solved exactly this shape
of problem for lodging artifacts (ae81a81e), but that commit sits on
fix/drop-building-part-without-age-band, an unmerged branch that has
since drifted far behind main. Reinstating the same filter (fresh, not
cherry-picked) fixes both the original artifact case and this SAP-15
alt-wall case, since RdSapSchema17_1 has nowhere else to put it either
way.
Verified against all 174 properties across the task's originally-failing
batches: zero remaining null-age-band building parts.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
from_api_response now returns None for an unsupported schema_type
instead of raising, so the harness must check before dereferencing
the mapped EpcPropertyData — otherwise an AttributeError replaces
the expected ValueError in calculator_error.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Review findings on PR #1527:
- The overlay constants, ScoredOption builder, ventilation dependency and
selected_types helper come from the shared _optimiser_fixtures module
(landed on the fabric-first base) instead of local copies; the boiler
overlay is the shared BOILER_OVERLAY (SAP Table 4a code 104, a mains-gas
combi) rather than code 201, which is neither a boiler nor a heat pump.
_IWI_OVERLAY (solid-wall internal, type 3) stays local — no shared
equivalent — and the carbon stubs stay bespoke (the shared StubScorer has
no CO2 knob).
- The optimise_package_fabric_first import is lifted to module scope.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Review findings on PR #1527:
- The 'which goals are goal-aligned' set lived in two adjacent if-chains
(_objective_for and _require_budget_for_goal_aligned) that had to stay in
sync — a new goal-aligned goal added to one but not the other would slip
the budget guard. Both now read a single _GOAL_ALIGNED_OBJECTIVES table.
- The goal strings are the canonical PortfolioGoal enum values, not
re-declared string constants, so goal-value drift can't silently degrade
a goal to max-SAP; _target_sap reads the enum too.
- _scored_candidate_groups takes objective without a default (its only
caller passes it).
- scoring.py: 'cached: float | None' -> Optional[float] per the CLAUDE.md
'Use Optional over | None' rule.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Review findings on PR #1527:
- The objective is required (no sap_rating default) on _repair_to_target,
_best_repair_candidate and _rescored_groups: every caller already passes
it, and a default would let a future call path silently optimise SAP for
a carbon/bill goal while pyright stayed green. The default stays on the
public optimise_package / optimise_package_fabric_first entry points.
- _best_repair_candidate hoists objective(current) out of the candidate
loop: current is loop-invariant, so for the Energy-Savings bill objective
this was one full BillDerivation.derive per candidate per repair iteration
for the same score.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
An unrecognised schema_type used to raise ValueError and abort the whole
call; now from_api_response logs a warning and returns None so one
unmapped cert doesn't break a batch. Schema 15.0 already has a mapper
(PR #1531) so it's unaffected; only genuinely unmapped versions skip.
OpenHousing logs a job but silently drops the appointment when no bookable
resource is sent, so the survey date never lands. log_job already sends the
configured default_resource; amend_job omitted the parameter unless the
request carried an explicit surveyor. Default amend's resource to the
configured surveyor too, and fail loudly at config load on a blank
ABRI_RELAY_DEFAULT_RESOURCE so the misconfiguration can't ship an empty
resource again.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Review findings on PR #1526:
- tests/domain/modelling/_optimiser_fixtures.py is the one home for the
overlay constants, the ScoredOption builder, the additive per-kind
StubScorer and the forced ventilation dependency; test_optimiser.py and
test_optimiser_fabric_first.py had byte-identical copies of each
(and _StubScorer / _VentStubScorer fold into one parameterised stub).
- Fixture worlds are domain-plausible per team convention: the fabric-vs-
heating contrast is a £12,000 EWI against a £3,200 gas boiler rather
than a £500 heat pump undercutting a £1,000 cavity wall; heating
overlays carry real identities (SAP Table 4a code 104 for the boiler,
a PCDF index for the heat pump) instead of code 201 doubling as both;
whole-dwelling double glazing is £3,500, not £500.
- Dead knobs removed: the unused _ROOF_OVERLAY, the always-zero roof
gain, the duplicate _BOILER_OVERLAY, and the nested conditional
expressions in the interaction stubs.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Review findings on PR #1526, behaviour-preserving:
- No fabric groups, or phase 1 committed nothing → delegate to the plain
optimise_package: the phase-2 prefix would be empty and its re-scoring
would reproduce the role-1 signals the groups already carry, one full
SAP-calculator run per Option for zero effect (the common case on
already-insulated stock).
- Phase 1 consumed every group → return the fabric package instead of a
phase-2 pass that can only select the empty package.
- _rescored_groups takes start_sap from the caller: the post-fabric
baseline score is the phase-1 package score already in hand, not a
fresh calculator run.
- fabric_types → phase_one_types: the set holds everything phase 1
committed, injected dependencies included — that inclusion is what the
outstanding-dependencies filter relies on, so the name must not invite
narrowing it to FABRIC_MEASURE_TYPES.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Re-attempted entering this SAP-15.0 cert's 4 real N/E/S/W windows (gov-API
sap_windows, 2.516 m^2 each) as separate Elmhurst Openings rows instead of
the accepted single combined South row, to test whether it closes the
residual ~2pt gap (engine 53 vs Elmhurst worksheet 51).
Reproduced live the documented elmhurst_lib.py window-grid limitation:
adding a 2nd row wipes the previously-added row's width/height to 0.00,
in both same-session and fresh-session-per-window attempts. Not fixable
via current Playwright automation. Restored the assessment to its original
single South 10.06 m^2 row (no PDFs re-downloaded, no worksheet change).
Separately confirmed our own engine already models this cert's windows
per-orientation correctly from gov-API sap_windows via
solar_gains.py's ORIENTATION_BY_SAP10_CODE cascade -- this is an Elmhurst
build-tooling ceiling, not an engine or mapper bug. sap_score=53 remains
unchanged; no calculator/mapper code was touched. Full accuracy suite
re-run clean (66 passed/67 skipped/1 xfailed + corpus test passed).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Both flagged mismatches were Elmhurst input errors (same silent-stale-value
contamination class as the earlier chimneys/wall-thickness bugs), not
parser or calculator bugs:
- cylinder_size: build_100010086084.py's water_heating() selected
DropDownListCylinderSize by raw value "2", but this DOM's option values
ARE their visible litre-band text (no "2" among them) — Playwright
silently no-ops on a non-matching value, leaving a prior cert's "Medium
(131-170L)" selection in place. Fixed to match by text ("Normal"), and
added the missing mapper dict entries (Normal/Large litre-suffixed
labels) to _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10 (a real mapper-coverage
gap — the calculator raises UnmappedElmhurstLabel rather than silently
mis-mapping).
- boiler_flue_type: the boiler-code search dialog's combined "Balanced/Open
Flue" Table 4b category doesn't drive the separate, independently
selectable RadioButtonListFlueType field, which was left at an inherited
"Balanced" from a prior cert. Fixed space_heating() to explicitly select
"Open" to match the lodged gov-API code. This field isn't consumed by
Sap10Calculator (ML/generator-only), so it had zero effect on the SAP
score.
Re-downloaded elmhurst_summary.pdf/elmhurst_worksheet.pdf after the fixes
(Recommendations page confirmed clean). Elmhurst-PDF-inputs path moved
46->47 SAP from the cylinder-volume correction; gov-API SAP (53) and
Elmhurst's own worksheet (51) are unchanged. Full accuracy suites re-run
clean (67 passed, 67 skipped, 1 xfailed, same as before).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
The Elmhurst rebuild for this cert had two carryover bugs from the shared
Playwright session: TextBoxOpenChimneys silently inherited "2" from a prior
cert's build (this cert's register lodges open_fireplaces_count=0, which
the gov-API mapper already reads correctly), and wall thickness inherited
a stale 280mm. Also fixed a real bug in the space_heating() PCDB-ref-clearing
logic: input_value() returns the string "0" when already cleared, which is
truthy in Python, causing a spurious navigate-away that broke the next
E.goto() call.
Rebuilt cleanly (chimneys=0, wall thickness=220mm per RdSAP convention for
unrecorded solid-wall thickness, since CheckBoxWallThicknessUnknown does not
persist via Playwright in this tool version). Elmhurst's own worksheet score
moves from a contaminated 46/48 to 51, closing the gap against this engine's
53-on-gov-API-inputs from ~5-7pt to ~2pt. No mapper.py change was needed --
the gov-API mapper's open_chimneys_count=0 was correct all along.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Built UPRN 100010086084 (the largest gov-API-vs-lodged outlier from the
20-cert batch) in Elmhurst's accredited RdSAP10 tool to get real ground
truth, per feedback that lodged rating isn't a valid comparison target.
Elmhurst worksheet: SAP 46-48 (orientation-dependent), vs this engine's
53 on gov-API inputs -- a real ~5-7pt residual gap. Ruled out with
direct empirical tests: total_floor_area, missing party_wall_length,
region/climate (SAP rating always uses UK-average weather per Appendix
U -- confirmed inert), boiler/secondary efficiency (exact match, 66%/
63% both sides). Confirmed real but NOT blind-fixed (need more than one
cert's evidence, and a wall-U-value patch tested the wrong direction in
isolation): a wall-thickness-unknown U-value fallback mismatch (this
engine 1.70, Elmhurst's own "unknown" resolution 1.40) and a window
U-value divergence (1.85 vs 2.52 W/m2K for the same nominal glazing
pick). Single-window orientation confirmed a ~2pt partial contributor.
Also fixes a small, separate, evidenced gap the build surfaced: the
Elmhurst summary parser didn't recognise the live tool's "Medium
(131-170L)" cylinder-size label (only the bare "Medium").
Full write-up is in the RealCertExpectation comment for this cert in
test_real_cert_sap_accuracy.py and the worklist. Residual gap is
intentionally left open for follow-up, not force-closed.