Publish container ports without a fixed host side in the backend and
asset_list compose files, and switch forwardPorts to service-qualified
form. Lets a second worktree's devcontainer spin up without conflicting
on host 8000/5432 (backend) or 8081 (asset_list), matching the pattern
in assessment-model-sales-frontend.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Code 3 = "(other premises below)" = above partially heated space (§3.12 →
U=0.7), confirmed 9/9 on single-BP certs (the diagnostic that dodged the
lossy-floors[] contamination). Records the 7536 re-pin and the lesson that
"irreducible residual" golden notes can mask a real mapper bug.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The API `floor_heat_loss` code is authoritative — confirmed by joining each
single-BP cert's code to its independent `floors[].description` (which the
gov register publishes alongside the code):
code 1 ↔ "To external air" (exposed, 9/9)
code 2 ↔ "To unheated space" (semi-exposed, 6/6)
code 3 ↔ "(other premises below)" (partially htd, 9/9)
code 6 ↔ "(another dwelling below)" (party, 176/176)
code 7 ↔ "Solid"/"Suspended …" (ground, all)
Code 3 was mis-mapped to "To unheated space" (semi-exposed) and, on
mid-/top-floor flats, had its floor area zeroed entirely by the
dwelling-level exposure heuristic. RdSAP 10 §3.12 (PDF p.25) classes a
flat's floor over non-domestic "other premises … heated, but at different
times" as "above a partially heated space" → the §5.14 (PDF p.47) constant
U=0.7 W/m²K — distinct from semi-exposed (Table 20) and party (no loss).
Fix: the mapper sets `is_above_partially_heated_space` on the floor=0
dimension for code 3 (string → "(other premises below)" for fidelity), and
the heat-transmission step lets that per-BP lodgement override the flat
suppression upward (mirroring the existing exposed / "another dwelling
below" overrides). The cascade already routes is_above_partial → U=0.7.
Re-pins golden cert 7536-3827: its Ext2 (bp3) lodges code 3, but the cert's
lossy `floors[]` summary dropped that description, so a prior agent guessed
"code 3 = ground" (U=1.12) and concluded the residual was an irreducible
"register-rounding" artifact. It was this bug: Ext2 floor U 1.12 → 0.70,
PE -6.1952 → -5.6414, CO2 -0.1639 → -0.1492 (both toward 0), SAP unchanged.
Eval: 909 computed, 45.1% → 45.3% within 0.5, mean|err| 1.702 → 1.659,
<1.0 59.5% → 60.2%. 13 code-3 certs improve (0380 +3.71 → -0.63, 0350
+7.82 → +0.83, 2610 +7.47 → -1.29); the few that overshoot were already
failing and carry independent fabric bugs (9763's walls = 8 W/K for 60 m²).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Record that profiler lead #1 (floor_codes=3) is not a clean single cause
(bimodal + confounded), that the paired worksheet certs confirm only
codes 1/6/7 (code 3 unmapped → needs a worksheet for 0380-2087), and that
immersion_type=2 / main_control=2107 / roof_codes=1 are scatter, not
dispatch bugs. The exposed-floor-on-flats fix (§3.12) shipped at b40e0f67.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A mid-/top-floor flat whose lowest floor is lodged as an exposed floor
(API floor_heat_loss=1) had its floor area zeroed by the dwelling-level
exposure heuristic, which keys only on the flat label and defaults
has_exposed_floor=False (assuming the floor sits over another *heated*
dwelling). RdSAP 10 §3.12 (PDF p.25) is explicit:
"Otherwise the floor area of the flat ... is:
- an exposed floor if there is an open space below"
i.e. a flat cantilevered over a passageway IS a heat-loss floor on
Table 20. The per-BP `is_exposed_floor` lodgement is authoritative and
now overrides the dwelling-level suppression upward, mirroring the
existing "another dwelling below" party override (which suppresses
downward). The code-1↔"E To external air" enum is confirmed by the
paired API+Summary worksheet certs (0350, 3800).
Eval: 45.1% → 45.3% within 0.5 (909 computed); cert 3836 +6.79 → +0.77,
5717 +1.31 → -0.07 and 0997 +0.76 → +0.05 cross into <0.5. Two
already-failing under-rated certs (7636, 2241) shift further — both are
dominated by independent cost-side over-counts the exposed floor merely
unmasks (7636 walls = 8.98 W/K for 33.87 m² is the real defect).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Joins each computed cert's signed error (eval _results.csv) with a rich
feature set extracted from its RAW API JSON (not the mapped
EpcPropertyData), then ranks (feature, value) buckets by error carried
and by |mean signed| bias. Surfaces systematic API-path handling gaps —
a field the mapper silently drops still shows as an error-correlated
bucket. Companion to eval_api_sap_accuracy.py / decompose_api_cost_error.py.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
main_heating_category=9 (warm-air systems, NOT heat pump) had no entry
in _SECONDARY_HEATING_FRACTION_BY_CATEGORY, so a warm-air main with a
lodged secondary raised UnmappedSapCode in
_secondary_heating_fraction_for_category — the last calc_raise in the
API sample (cert 0380-2197-2590-2996-2715: warm air mains gas code 506 +
electric room-heater secondary).
SAP 10.2 Table 11 (p.188): a gas/oil warm-air unit falls under "All gas,
liquid and solid fuel systems" (0.10), and electric warm air under
"Other electric systems" (also 0.10) — so 0.10 regardless of fuel. The
warm-air efficiency (Table 4a code→eff: 506→0.70) and Table 4f fan
energy were already wired; this was the only missing dispatch entry.
0380 now computes: SAP 78.1 vs lodged 77 (+1.1; the residual is per-cert
fabric/PV, not the warm-air dispatch — a faithful 0380 worksheet isn't
available, sim case 28 diverges at SAP 57 / code 502 / condensing unit).
Eval: zero raises remain, computed 908→909; mean|err| 1.703→1.702.
Regression green (2448 pass incl. golden 6035 + cohort); pyright
net-zero (44=44).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
API floor_heat_loss=8 is observed on EXTENSION building parts whose
floor sits over a heated space within the SAME dwelling (an upper-storey
extension over a heated room). RdSAP 10 §3 gives an internal floor
between heated storeys no floor heat loss — mechanically identical to a
code-6 party floor. `_api_floor_type_str` had no entry for 8, raising
UnmappedApiCode and blocking certs 0370-2254-6520-2426-5971 and
0997-1206-9806-0715-2904.
Map code 8 to the code-6 no-heat-loss string "(another dwelling below)"
(consumed by heat_transmission's party-floor suppression; != "Ground
floor" so the §5 (12) suspended-timber rule stays inert). Empirically
confirmed against both certs: the no-heat-loss treatment lands them
within 0.5 of lodged (0370-2254 68.92 vs 69; 0997-1206 40.68 vs 41),
whereas Ground-floor / unheated / external mappings miss 0997 by ~4 SAP.
Eval computed 906→908. Regression green (only the pre-existing
test_total_floor_area fails); pyright net-zero (38=38).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>