Khalim Conn-Kowlessar
4d0e2ed6cf Slice S0380.162: SAP 10.2 Appendix N3.1 default pump gain for electric HPs
SAP 10.2 Appendix N3.1 (PDF p.105) "Circulation pump and fan":
"For electric heat pumps: The electricity used by the water
circulation pump or fan is included within the calculated annual
space and hot water heating efficiency and is not included in
worksheet (230c). **The default heat gain from Table 5a is included
via worksheet (70).**"

This rule applies the Table 5a row "Central heating pump in heated
space" GAIN (3 / 10 / 7 W per pump-age bucket) to electric heat
pumps even though the pump ELECTRICITY is hidden in the COP and
excluded from (230c). The "Not applicable for electric heat pumps
from database" clause in Table 5a footnote a) scopes only to the
PCDB-Table-362 cascade case (Appendix N1.2.1: "For heat pumps held
in the PCDB ... a single water circulation pump serving the heat
emitters is sufficient" — pump kWh AND gain embedded in COP).

S0380.160 over-stripped the gain by zeroing pump_w for every HP
category-4 main, conflating the PCDB-Table-362 case with the Table-4a
default cascade. This slice refines the HP gate in
`_any_main_system_has_central_heating_pump`:
  - Cat 4 HP WITH `main_heating_index_number` lodged (PCDB Table
    362) → continue (skip; pump in COP per N1.2.1);
  - Cat 4 HP with SAP code in `_TABLE_4A_WARM_AIR_SAP_CODES` (Cat 5
    warm-air HPs distribute via ducted air, no water circulation
    pump; warm-air fan handled separately by Table 5a "Warm air
    heating system fans" row, S0380.161) → continue;
  - Otherwise (Cat 4 HP, Table 4a default cascade, water-emitter)
    → apply Table 5a default per Appendix N3.1.

Per-line walk on ashp (SAP code 214 air-to-water HP, Cat 4, no PCDB,
"Post 2013" pump age):
  worksheet (70)[Jan] = 3.0000 W
  cascade pre-slice    = 0.0000 W      delta = -3.000 W
The -3 W winter gain shortfall over-stated cascade (84) Total gains
by -3 W in heating months → cascade SH demand +12.27 kWh/yr
(cascade 9302 vs worksheet 9290), pushing continuous SAP down 0.024
because the cost residual was driven by the +1.5 kWh × 12 month
shortfall flowing through the £0.0741 low-rate cost.

Closures:
  ashp:  ΔSAP -0.0240 → +0.0000 EXACT, Δcost +£0.55 → +£0.00 EXACT
  gshp:  ΔSAP -0.0178 → -0.0000 EXACT, Δcost +£0.41 → -£0.00 EXACT

ΔPE +36 → +25.51 (and ΔCO2 +7.33 → +6.31) — residuals narrow to the
Elmhurst-vs-spec HW PE annual-vs-monthly Table 12e/12d quirk only
(same pattern as the 16-variant lighting-PE deferred cohort,
scaled by HW kWh = 1138 vs 2384 → 25.51 vs 48.66). Cohort
Σ |ΔSAP_c| 0.07 → 0.03; all 25 cascade-OK variants now SAP+cost EXACT.

Cohort-1 (cert 0380 et al.) golden fixtures unaffected — those certs
lodge `main_heating_index_number` (PCDB Table 362) → HP gate skips
correctly → (70) = 0 preserved. Cert 000565 (HP main 1 + gas boiler
main 2) unaffected — wet-boiler branch fires for main 2.

Verbatim spec quote (SAP 10.2 Appendix N3.1, PDF p.105):
  "For electric heat pumps: The electricity used by the water
   circulation pump or fan is included within the calculated annual
   space and hot water heating efficiency and is not included in
   worksheet (230c). The default heat gain from Table 5a is
   included via worksheet (70)."

Tests: 906 pass (+1), 0 fail. Pyright net-zero (35 → 35).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
b3196cdcf5 Slice S0380.161: SAP 10.2 Table 5a warm-air fan gain (SFP × 0.04 × V)
SAP 10.2 Table 5a (PDF p.177) row "Warm air heating system fans
a) c)" computes the gain as SFP × 0.04 × V (W). Footnote c) sets
the default SFP to 1.5 W/(l/s) when no PCDB warm-air-unit record
is lodged; footnote a) applies the heating-season-only mask
(zero in summer months). Footnote c) further omits the gain when
the dwelling has balanced whole-house mechanical ventilation
(MVHR / MV) — same omission as the Table 4f kWh-side footnote e).

Pre-slice the cascade's `internal_gains_from_cert` only wired the
central-heating-pump row of Table 5a; the warm-air-fan gain helper
(`warm_air_heating_fan_w`) existed but was unwired. The kWh-side
parallel (Table 4f, 136.35 kWh/yr) was wired in S0380.158 — this
slice closes the symmetry on the gain side.

Per-line walk on electric 2 (SAP code 524 = Cat 5 ASHP with
warm-air distribution, V = 227.25 m³, no balanced MV):

  worksheet (70)[Jan] = 13.6350 W
  cascade (70)[Jan]   = 0.0000 W      delta = -13.635 W
  worksheet (98c)[Jan] = 1600.43 kWh
  cascade (98c)[Jan]  = 1608.12 kWh   delta = +7.69 kWh

13.635 W = 1.5 × 0.04 × 227.25 exactly. The -13.6 W winter gain
shortfall propagates through the §7 utilisation cascade and over-
states cascade SH demand by ~57 kWh/yr (cascade 9483 vs worksheet
9426), under-charging cost by ~£2.50 with opposite sign to the
S0380.156-.158 closures.

Fix: new `_any_main_system_has_warm_air_distribution(epc)` +
`_has_balanced_mechanical_ventilation(epc)` predicates in
`internal_gains.py`, mirroring `cert_to_inputs._TABLE_4A_WARM_AIR_SAP_CODES`
+ `_BALANCED_MV_KIND_NAMES` (kept here as siblings so the worksheet
layer stays free of rdsap deps). Orchestrator wires
`warm_air_heating_fan_w(sfp=1.5, dwelling_volume_m3)` into the
heating-season term of `pumps_fans_monthly_w` when warm-air
distribution is present and balanced MV is not.

Closures electric 2:
  ΔSAP_c -0.1087 → -0.0000 EXACT
  Δcost  +£2.50 → -£0.00 EXACT
  ΔCO2   +16.54 → +11.95 (joins lighting-PE deferred cohort)
  ΔPE    +97.69 → +48.66 (joins lighting-PE deferred cohort)

Electric 2 joins the 15-variant lighting-PE deferred cohort
(electric 1 + electric 3/5/6/7/8/9 + solid fuel 5/6/7/8 + solid
fuel 4/9/10/11 + electric 2) where SAP/cost are EXACT but PE/CO2
carry an Elmhurst-vs-spec MONTHLY-factor offset (cohort uses
Table 12 annual factors on the off-peak HW immersion line; spec
mandates Table 12d/12e monthly per the header).

Verbatim spec quote (SAP 10.2 Table 5a row "Warm air heating
system fans a) c)", PDF p.177):
  "Warm air heating system fans a) c)  SFP × 0.04 × V"
  Footnote c): "SFP is the specific fan power from the database
    record for the warm air unit if applicable; otherwise
    1.5 W/(l/s). These values of SFP include an in-use factor.
    If the heating system is a warm air unit and there is balanced
    whole house mechanical ventilation, the gains for the warm air
    system should not be included."
  Footnote a): "... Set to zero in summer months. ..."

Σ |ΔSAP_c| across 25-variant cohort: 0.18 → 0.07 (~60% reduction).
No regressions on the other 24 variants or any golden fixture —
gate keyed on Table 4a warm-air SAP code frozenset (only electric
2 in the corpus has a code in that set).

Tests: 905 pass (+1), 0 fail. Pyright net-zero (35 → 35).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
d793ae8851 Slice S0380.160: SAP 10.2 Table 5a wet-pump gate for central heating gain
SAP 10.2 Table 5a (PDF p.177) row "Central heating pump in heated
space" only applies to mains with a water-loop circulation pump.
Footnote a) names two exclusions verbatim ("Does not apply if a
heating system used solely for domestic hot water. ... Not applicable
for electric heat pumps from database."), and the row's name carries
the implicit third: dry mains with no central heating pump (electric
storage heaters, electric direct-acting, solid-fuel room heaters
without back-boilers) — the row simply doesn't list them.

Pre-slice `internal_gains_from_cert` gated only on Note a) (HP
exclusion), applying `central_heating_pump_w(date_category=...)` to
every non-HP main. The default UNKNOWN-date branch added 7 W of pump
gain to (70)m for every dry-system fixture in the controlled-variable
corpus, even though the worksheet (70)m = 0 every month.

Per-line walk on electric 3 (SAP code 401 "Manual charge control"):

  cascade (73)[Jan] = 640.21 W
  worksheet (73)[Jan] = 633.21 W      delta = +7.00 W
  cascade (70)[Jan] = 7.00 W
  worksheet (70)[Jan] = 0.00 W        Table 5a inapplicable

The +7 W winter-month gain lowered cascade SH demand by ~38 kWh/yr
(cascade 11050 vs worksheet 11088). At Table 32 18-hour low-rate
~7.4 p/kWh that's £2.50/yr under-charging — matching the cluster's
uniform Δcost = -£1.96..-£2.80 pattern. Continuous SAP rose ~+0.10
because cost dominates the ECF.

Fix: new `_any_main_system_has_central_heating_pump(epc)` predicate
in `internal_gains.py`, mirroring `cert_to_inputs._is_wet_boiler_main`
(S0380.149 — Table 4f kWh side). Wet if any non-HP main lodges:
  - sap_main_heating_code in {101-141, 151-161, 191-196} (gas/oil/
    solid-fuel/electric boilers per Table 4a/4b),
  - main_heating_index_number (PCDB Table 322 record),
  - main_heating_category in {1, 2} (RdSAP central heating), OR
  - heat_emitter_type in {1, 3} (radiators / fan-coil per Table 4d).

Dead `_all_main_systems_are_heat_pumps` helper removed (the new
predicate subsumes its role).

Cluster closures (10 variants):
  electric 3:    SAP +0.1215 → -0.0000, cost -£2.80 → -£0.00
  electric 5:    SAP +0.1081 → -0.0000, cost -£2.49 → -£0.00
  electric 6:    SAP +0.1081 → -0.0000, cost -£2.49 → -£0.00
  electric 7:    SAP +0.1017 → -0.0000, cost -£2.34 → -£0.00
  electric 8:    SAP +0.0941 → -0.0000, cost -£2.17 → -£0.00
  electric 9:    SAP +0.1199 → -0.0000, cost -£2.76 → -£0.00
  solid fuel 4:  SAP +0.0850 → -0.0000, cost -£1.96 → -£0.00
  solid fuel 9:  SAP +0.1072 → -0.0000, cost -£2.47 → -£0.00
  solid fuel 10: SAP +0.1134 → +0.0000, cost -£2.61 → -£0.00
  solid fuel 11: SAP +0.0912 → +0.0000, cost -£2.10 → +£0.00

Σ |ΔSAP_c| across 25-variant cohort: 1.24 → 0.18. All 10 cluster
variants now join the lighting-PE +48.66 / CO2 +11.95 deferred
cohort (Elmhurst-vs-spec monthly factor quirk, same shape as
electric 1 + solid fuel 5/6/7/8 from prior closures).

Verbatim spec quote (SAP 10.2 Table 5a row 1, PDF p.177):
  "Central heating pump in heated space, 2013 or later  3 a)"
  "Central heating pump in heated space, 2012 or earlier  10 a)"
  "Central heating pump in heated space, unknown date  7 a)"

The row name ("Central heating pump") gates by construction: dry
systems have no central heating pump and the row's three sub-rows
don't apply.

No regressions on the other 31 variants or any golden fixture; the
6 Elmhurst U985 fixtures lodge PCDB index → the new predicate
returns True → pump_w unchanged.

Tests: 904 pass (+1), 0 fail. Pyright net-zero (35 → 35).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
5d086f3ed1 Slice S0380.159: SAP 10.2 Table 4a R tariff-aware dispatch for electric storage
SAP 10.2 Table 4a (PDF p.166) Cat 7 "Electric storage heaters"
splits the responsiveness R between two sub-tables:

  Off-peak tariff:
    Slimline storage heaters       ... R = 0.2  402
    Convector storage heaters      ... R = 0.2  403
    Slimline + Celect-type control ... R = 0.4  405
    Convector + Celect-type ctrl   ... R = 0.4  406
  24-hour heating tariff:
    Slimline storage heaters       ... R = 0.4  402
    Convector storage heaters      ... R = 0.4  403
    Slimline + Celect-type control ... R = 0.6  405
    Convector + Celect-type ctrl   ... R = 0.6  406

Per SAP 10.2 §12.4.3 (PDF p.36) the 18-hour tariff has electricity
at low rate for 18 hours per day with at most 6h of interruption /
2h max each — operationally equivalent to 24-hour for storage-heater
charging. The cascade therefore routes EIGHTEEN_HOUR + TWENTY_FOUR_
HOUR through the 24-hour Table 4a sub-row.

Pre-slice `_responsiveness` keyed on `sap_main_heating_code` only
and returned R=0.2 for code 402 regardless of tariff. The existing
docstring already flagged the gap:

    402: 0.20,  # Slimline storage heaters (24-hr tariff: 0.40)
    ... "promote to (sap_code, tariff) lookup when 24-hour fixture
    surfaces; until then the off-peak default applies (under-shoots
    R for the 24-hour case)."

Per-line walk on electric 5 (sap_main_heating_code=402 +
meter_type="18 Hour"): cascade T_living (87)[Jan] = 20.1213 vs
worksheet 19.6519, (92)[Jan] = 18.6996 vs worksheet 18.2063, (93)
[Jan] = 19.0996 vs worksheet 18.6063 (cascade +0.4933 K throughout
the cascade). Back-solve from worksheet T_living=19.6519 via the
Table 9b Tsc formula:

  Tsc(R=0.4) = 0.6 × (21-2) + 0.4 × (4.3 + 0.9933 × 705.4/210.23)
             = 11.4 + 0.4 × 7.6325 = 14.4528

  ΔT = 21 - 14.4528 = 6.5472
  u_sum = 0.5 × 6.5472 × (7² + 8²) / (24 × 11.43) = 1.3481
  T_living = 21 - 1.3481 = 19.6519 EXACT match.

Adds:
  - `_CONTINUOUS_CHARGING_TARIFFS: frozenset[Tariff]` = {EIGHTEEN_
    HOUR, TWENTY_FOUR_HOUR} — the tariffs treated as "24-hour
    heating" for Table 4a R selection.
  - `_RESPONSIVENESS_24_HOUR_OVERRIDE_BY_SAP_CODE: dict[int, float]`
    — the override table for codes 402/403/405/406 (404, 407, 409
    keep the same R in both sub-tables).
  - `tariff: Optional[Tariff]` parameter to `_responsiveness`, with
    the override consulted before the off-peak default.
  - Tariff threaded through both call sites of MIT cascade (rating
    + demand paths) via `tariff_from_meter_type`.

Closures electric 5:
  ΔSAP −1.1759 → +0.1081 (91% reduction)
  Δcost +£27.09 → −£2.49
  ΔCO2 +62.72 → +7.30 kg
  ΔPE +438.03 → +0.07 kWh (essentially EXACT)

Electric 5 now joins the same residual cluster as electric 3/6/7/8/
9 (+0.09..+0.12 SAP, −£2..−£3 cost, +£7 CO2) — the cluster that
the prior handovers suspected was a shared shave-the-residual gap.

No regressions on the other 24 cohort variants. Extended handover
suite: 903 pass / 0 fail (was 902 — +1 from the new AAA test).
Pyright net-zero (43 → 43).

Σ |ΔSAP_c| across the 25-variant cohort: 2.30 → 1.24 (~46%
reduction from this slice).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
4291193ba8 Slice S0380.158: SAP 10.2 Table 4f warm-air heating system fans
SAP 10.2 Table 4f (PDF p.174) row "Warm air heating system fans"
+ footnote e) — verbatim:

  Warm air heating system fans e)        SFP × 0.4 × V

  e) SFP is the specific fan power from the database record for the
     warm air unit if applicable; otherwise 1.5 W/(l/s). These values
     of SFP include the in-use factor.
     If the heating system is a warm air unit and there is balanced
     whole house mechanical ventilation, the electricity for warm
     air circulation should not be included in addition to the
     electricity for mechanical ventilation. However it is included
     for a warm air system and MEV or PIV from outside.
     V is the volume of the dwelling in m³.

Per Table 4a (PDF p.165-166), warm-air systems are:
  - Category 5: heat pumps with warm-air distribution (codes 521,
    523, 524 electric; 525, 526, 527 gas-fired)
  - Category 9: warm-air systems NOT heat pump (501-511, 520 gas-
    fired; 512-514 liquid-fired; 515 Electricaire electric)

Pre-slice the cascade's `_table_4f_additive_components` docstring
explicitly listed "(230b) Warm-air heating fans + (230c) for warm-
air pump" as "Not yet wired" — every Cat 5 / Cat 9 warm-air corpus
variant resolved `pumps_fans_kwh_per_yr` to 0. For electric 2 (code
524 Cat 5 air-source warm-air HP, no MV, V = 227.25 m³), the P960
worksheet block 11a (249) lodges 136.35 kWh × 13.67 p/kWh = £18.64
where the cascade computed 0.

New `_TABLE_4A_WARM_AIR_SAP_CODES` frozenset (22 codes) + leaf helper
`_table_4f_warm_air_heating_fans_kwh(main, dwelling_volume_m3,
has_balanced_mv)` wired at the orchestrator pumps_fans summation
alongside the existing circulation-pump and gas-flue-fan helpers.
Footnote-e balanced-MV omission reads `epc.sap_ventilation.
mechanical_ventilation_kind` via the new
`_has_balanced_mechanical_ventilation` predicate (returns True for
MVHR / MV; False for MEV / PIV / NATURAL).

Per-line walk evidence: cascade `pumps_fans_kwh_per_yr` = 0.0000 vs
worksheet (249) = 136.3500 = 1.5 × 0.4 × 227.25 exactly. Default SFP
from footnote e matches; PCDB warm-air-unit SFP lookup deferred
until a fixture exercises it.

Closures electric 2:
  pumps_fans_kwh_per_yr: 0 → 136.35 (EXACT match to worksheet)
  ΔSAP +0.7002 → −0.1087 (residual swung past worksheet — the +0.70
    pre-slice was an under-counted-fan offset; spec-correct fix lands
    just past zero, exposing a small upstream SH cascade gap likely
    in the Cat 5 warm-air HP Table 4a SH efficiency or Table 9c MIT
    cascade for warm-air mains — follow-up slice)
  Δcost −£16.14 → +£2.50
  ΔCO2 −2.37 → +16.54 kg
  ΔPE −108.58 → +97.69 kWh

No regressions on the other 24 cohort variants — the warm-air-code
gate fires only when `sap_main_heating_code` is in the new frozenset
and only electric 2 has a warm-air SAP code in the corpus. Extended
handover suite: 902 pass / 0 fail (was 901 — +1 from the new AAA
test). Pyright net-zero (43 → 43).

Σ |ΔSAP_c| across the 25-variant cohort: 2.87 → 2.30 (~20%
reduction from this slice).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
8507728237 Slice S0380.157: SAP 10.2 Table 2b note b) WHC=903 electric-immersion guard
SAP 10.2 Table 2b note b) (PDF p.159) — verbatim:

  Multiply Temperature Factor by 0.9 if there is separate time
  control of domestic hot water (boiler systems, warm air systems
  and heat pump systems).

The parenthetical list restricts the rule to systems where the heat
generator (boiler / warm-air / HP) is the device heating the
cylinder. Electric immersion is NOT in that list because the
immersion isn't a heat-generator system feeding DHW — it sits inside
the cylinder. The ×0.9 multiplier reflects shorter cylinder-heating
periods when a boiler / HP / warm-air operates on a separate timer
for DHW vs SH; if the heat generator doesn't feed the cylinder at all
(because the immersion does), there's no such timing effect.

Pre-slice `_separately_timed_dhw` returned True for any Cat 4 HP
main BEFORE consulting WHC (line 3872 `if main.main_heating_category
== 4: return True`). For electric 2 (sap_main_heating_code=524 Cat 5
warm-air ASHP, main_heating_category=4 per Elmhurst mapper, WHC=903
electric immersion + cylinder + cylinder thermostat lodged), the
cat-4 branch fired before the existing `_is_electric_water` check
could route the cert to False. The cascade applied ×0.9 to the
Temperature Factor (53), pulling (55) from 1.2294 → 1.1064 → cascade
annual (56) = 403.87 vs worksheet (56) annual = 448.73.

Same WHC=903 principle as the prior slice S0380.156 (Table 3 zero-
loss list for electric immersion): when HW is independent of the
main heating, main-heating-specific DHW rules don't apply — even
when the main happens to be a HP / boiler / warm-air system.

Fix: new top-of-function `if epc.sap_heating.water_heating_code ==
_WHC_ELECTRIC_IMMERSION: return False` guard in
`_separately_timed_dhw`. Reuses the constant introduced in S0380.156.

Closures electric 2:
  Cylinder (56) storage loss annual 403.87 → 448.73 (matches
  worksheet 1.2294 × 365 = 448.73 EXACT within rounding)
  HW kWh demand 2339.24 → 2384.12 (matches worksheet (62)/(64) =
  2384.116 EXACT)
  ΔSAP +0.8118 → +0.7002
  Δcost −£18.71 → −£16.14
  ΔCO2 −7.21 → −2.37 kg
  ΔPE −161.68 → −108.58 kWh

The remaining +0.70 SAP residual is a separate upstream gap (likely
warm-air-HP SH cascade or Table 4a SH efficiency for code 524) —
follow-up slice.

No regressions on the other 24 cohort variants. Cohort-1 ASHP certs
(Cat 4 HP + WHC=901 = HW from HP + cylinder) keep ×0.9 as before
because their WHC=901 doesn't trigger the new guard. Extended
handover suite: 901 pass / 0 fail (was 900 — +1 from the new AAA
test). Pyright net-zero (43 → 43).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Khalim Conn-Kowlessar
c727b3cb5a Slice S0380.156: SAP 10.2 Table 3 WHC=903 electric-immersion zero-loss guard
SAP 10.2 Table 3 (PDF p.160) verbatim:

  Primary loss is set to zero for the following:
      Electric immersion heater
      Combi boiler ...
      CPSU ...
      Boiler and thermal store within a single casing
      Separate boiler and thermal store connected by no more than 1.5
      m of insulated pipework
      Direct-acting electric boiler
      Heat pump (...) with hot water vessel integral to package

The Elmhurst WHC=903 lodging signals exactly the first row: "HW from
a separate electric immersion heater" — the cylinder is heated by an
immersion element inside the tank, no primary pipework between any
heat generator and the cylinder. The rule is universal: regardless
of what main heating exists for space heating, electric immersion
means no primary circuit means no primary loss.

Pre-slice `_primary_loss_applies` only consulted `water_heating_code`
in the Table 4a wet-boiler branch (codes 151-161 / 191-196). The Cat
4 HP branch returned True unconditionally when no PCDB record was
lodged; the Cat 1/2 boiler branch returned True unconditionally; the
PCDB Table 322 + Table 4b non-PCDB branches likewise. For the
electric 2 corpus variant (sap_main_heating_code=524 Cat 5 warm-air
ASHP, main_heating_category=4 per Elmhurst mapper, no PCDB record,
WHC=903 + cylinder), the Cat-4 branch falsely returned True and the
cascade added ~510 kWh/yr primary loss to a system with no primary
circuit at all.

Per-line walk discipline applied: cascade `water_heating_from_cert`
output dump showed `primary_loss_monthly_kwh_annual = 509.98` while
worksheet (59)m = 0 every month → spec lookup found Table 3 verbatim
"Electric immersion heater" zero-loss line.

Adds `_WHC_ELECTRIC_IMMERSION: Final[int] = 903` constant + a
top-of-function `if water_heating_code == _WHC_ELECTRIC_IMMERSION:
return False` guard that fires before any of the system-type-keyed
branches.

Closures electric 2:
  HW kWh 2849.22 → 2339.24 (matches worksheet (62)/(64) = 2384.12
  within the residual ~45 kWh storage-loss gap)
  ΔSAP −0.4584 → +0.8118 (cascade swung past the worksheet by +1.27
  — the pre-slice 'near-correct' value was offsetting cascade bugs
  per [[feedback-software-no-special-handling]]; the +0.81 residual
  exposes a separate upstream gap to chase in a follow-up slice)
  Δcost +£10.56 → −£18.71
  ΔCO2 +47.89 → −7.21 kg
  ΔPE +443.13 → −161.68 kWh

No regressions on the other 24 cohort variants — only electric 2 has
the (Cat 4 HP, no PCDB, WHC=903) combination in the corpus.
Extended handover suite: 900 pass / 0 fail (was 899 — +1 from the
new AAA test). Pyright net-zero (43 → 43).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-04 15:40:25 +00:00
Daniel Roth
a68ab01d70 All downloaded PasHub files uploaded to SharePoint property folder 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
3d2a21d9d9 All downloaded PasHub files uploaded to SharePoint property folder 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
815173bc79 tweak local trigger 2026-06-04 15:40:25 +00:00
Daniel Roth
35b65d0d8d adjust comment about evidence type 2026-06-04 15:40:25 +00:00
Daniel Roth
5fa6f32644 Service persists mcs_certificate file_type when evidence_category is MCS cert 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
367f6f6cf9 Downloaded files carry evidence_category as DownloadedFile 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
1e2b997f2f Downloaded files carry evidence_category as DownloadedFile 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
e18c300deb MCS cert identified by evidence_category in get_core_file_type 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
1af1d4a82c MCS cert identified by evidence_category in get_core_file_type 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
5ed3bf73e8 evidence categories plus typehinting 2026-06-04 15:40:25 +00:00
Daniel Roth
020a24d345 run() returns core and other file paths 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
d8ec12065f run() returns core and other file paths 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
0aa6a4fc30 Other files persisted to DB with file_type OTHER 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
1650762ae2 Other files persisted to DB with file_type OTHER 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
c86dbeb4a1 Upload other files to S3 when get_other_files is True 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
098f60ecfd Upload other files to S3 when get_other_files is True 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
9c38f45c98 tidying for readability 2026-06-04 15:40:25 +00:00
Daniel Roth
c9a2ce4921 Service deletes other-file temp paths after run 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
f8d2bb8049 Service deletes other-file temp paths after run 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
49e7b7fea6 Wire service to get_evidence_files_by_job_id; retire get_core_evidence_files_by_job_id 🟪 2026-06-04 15:40:25 +00:00
Daniel Roth
662f6de0ab get_evidence_files_by_job_id downloads other files when include_other=True 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
c4ffaaa069 get_evidence_files_by_job_id downloads other files when include_other=True 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
f95b6bdd7d get_evidence_files_by_job_id returns DownloadedFiles with empty other when include_other=False 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
665dc69ad5 get_evidence_files_by_job_id returns DownloadedFiles with empty other when include_other=False 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
e7c679e0db Group evidence into core and other via _group_into_core_and_other_files 🟪 2026-06-04 15:40:25 +00:00
Daniel Roth
99229844b5 _select_other_files returns non-core evidence files 🟩 2026-06-04 15:40:25 +00:00
Daniel Roth
db796747d9 _select_other_files returns non-core evidence files 🟥 2026-06-04 15:40:25 +00:00
Daniel Roth
6cb6c8c756 allow for missing deal stage column when triggering sqs from file 2026-06-04 15:40:25 +00:00
Daniel Roth
790e430aff rename local handler trigger script 2026-06-04 15:40:25 +00:00
Jun-te Kim
dfd05ba28b tests files 2026-06-04 11:47:42 +00:00
Jun-te Kim
c614ff6388 save local changes 2026-06-03 12:41:56 +00:00
Jun-te Kim
4e02eb7c77 more tests to ensure we don't deploy something that is brokern 2026-06-02 15:03:20 +00:00
Jun-te Kim
144233a5f3 backend was missing a dependency 2026-06-02 10:46:29 +00:00
Khalim Conn-Kowlessar
5a3be9d672 feat(ingestion): relocate EpcClientService to infrastructure + SolarRepo (#1133)
Move the EpcClientService package (client + _retry + exceptions + tests) from
the dying backend/ tree to infrastructure/epc_client/ as the New-EPC-API Fetcher;
update the two callers (address2UPRN, a script). All 14 client tests pass.

Add SolarRepository port + SolarPostgresRepository persisting Google Solar
building insights as JSONB (solar_building_insights table), one row per Property.
The EPC repo half of this slice already landed in #1129. pyright strict clean.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
559616d3bb feat(epc): EPC persistence round-trip fidelity + JSONB code columns (Slice 1 #1129)
Relocate EpcPropertyModel + child tables from the dying backend/ tree to
infrastructure/postgres/epc_property_table.py (re-export shim keeps
documents_parser working). Add EpcRepository port + EpcPostgresRepository with
a full reverse mapper (epc_property tables -> EpcPropertyData).

Round-trip test surfaced two fidelity gaps:
 1. Union[int,str] SAP code fields were str()-coerced on save, losing the int
    (API) vs str (Site Notes) distinction. Now stored as JSONB (type-preserving).
 2. The schema was a partial projection. Closed the cheap gaps on the model
    (heating shower/bath counts, roof_construction_type, curtain_wall_age,
    addendum, mechanical_vent_duct_insulation_level, SAP 10.2 §2 ventilation
    fields + a ventilation_present flag). Structural gaps tracked as follow-ups;
    renewable_heat_incentive (P0, #1137) excluded from the assertion until landed.

Round-trip passes for RdSAP-Schema-21.0.0 and 21.0.1; pyright strict clean.
Migration inventory for the DB: docs/migrations/epc-property-round-trip-fidelity.md

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
ca6a0efd70 Slice S0380.155: SAP 10.2 Table 4a — heat-pump water-efficiency column dispatch
SAP 10.2 Table 4a (PDF p.163-164) heat-pump rows split efficiency into
two columns — "space" and "water":

    Code  System                                            space  water
    211   Ground source HP with flow temp <= 35°C            230    170
    213   Water source HP with flow temp <= 35°C             230    170
    215   Gas-fired GSHP with flow temp <= 35°C              120     84
    216   Gas-fired WSHP with flow temp <= 35°C              120     84
    217   Gas-fired ASHP with flow temp <= 35°C              110     77
    521   Warm-air electric GSHP                             230    170
    523   Warm-air electric WSHP                             230    170
    525   Warm-air gas-fired GSHP                            120     84
    526   Warm-air gas-fired WSHP                            120     84
    527   Warm-air gas-fired ASHP                            110     77

The split reflects real physics: heat pumps lose efficiency raising
water to ~55°C DHW temperatures vs ~35°C space-heating flow. ASHP
"in other cases" (codes 214, 221, 223, 224) and the "other cases"
gas-fired rows (225-227) have space == water = 170 / 84 / 77 — no
distinct DHW column.

Pre-slice the cascade routed WHC ∈ {901, 902, 914} ("HW from main
heating") through `seasonal_efficiency(main_code)`, which only consults
the Space column. For SAP code 211 the cascade returned 2.30 (= space)
when the spec requires 1.70 (= water). HW fuel kWh undercounted by
26% on the heating-systems corpus gshp variant: cascade 841.47 kWh vs
worksheet 1138.46 kWh.

New `_TABLE_4A_HEAT_PUMP_WATER_EFFICIENCY` dict (10 codes where Space
≠ Water) consulted in `_water_efficiency_with_category_inherit` before
falling through to the existing `seasonal_efficiency` path. Codes
where Space == Water keep the legacy inheritance — no behaviour
change. Non-HP main heating (boilers, storage heaters) likewise
unchanged.

Closures (gshp variant — SAP code 211 + WHC=901 + cylinder):
  HW fuel kWh:  841.47 → 1138.45 (matches worksheet 1138.46)
  ΔSAP_c:       +0.9373 → -0.0178
  Δcost:        -£21.60 → +£0.41
  ΔCO2:         -34.98  → +7.06 kg/yr
  ΔPE:          -418.92 → +33.52 kWh/yr

No regressions on 40 other corpus variants — gshp is the only fixture
that lodges a heat-pump code with diverging Space/Water columns.

Cohort-1 ASHP closure (S0380.28 reciprocal interpolation) is unaffected
because that path runs through `heat_pump_record` PCDB Appendix N3
when a PCDB Table 362 record is lodged; this fix is the Table 4a
fallback for cases without a PCDB record.

Extended handover suite: 899 pass / 0 fail. Pyright net-zero (43 → 43).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
981aaadf73 Slice S0380.154: SAP 10.2 §12.4.4 — back-boiler summer-immersion HW split
SAP 10.2 §12.4.4 (PDF p.36-37):

  "Independent boilers that provide domestic hot water usually do so
   throughout the year. With open fire back boilers or closed room
   heaters with boilers, an alternative system (electric immersion)
   may be provided for heating water in summer. In that case water
   heating is provided by the boiler for months October to May and by
   the alternative system for months June to September."

Scope is verbatim Table 4a codes 156 (Open fire with back boiler to
radiators) and 158 (Closed room heater with boiler to radiators). Range
cooker boilers (160, 161), pellet stoves with boilers (159), and
independent solid-fuel boilers (151, 153, 155) are NOT covered.

Pre-slice, the cascade treated the back-boiler cohort identically to
year-round solid-fuel mains: (59)m primary loss applied Jun-Sep, HW
fuel kWh was billed entirely at the boiler's solid-fuel rate, the HW
CO2 / PE factors used the boiler fuel's annual factor, and the off-peak
electric standing charge (£40 for 18-hour tariff) was not added because
the cert's lodged water-heating fuel code was anthracite.

Implementation (4 wired pieces):

1. `_section_12_4_4_summer_immersion_applies(epc, main)` — predicate
   gate keyed on back-boiler SAP code (156, 158) + WHC ∈ {901, 902, 914}
   "HW from main heating" + cylinder present.

2. `_primary_loss_override` zeroes (59)m for Jun-Sep when the predicate
   fires — matches the Elmhurst P960 worksheet which has (59) Jun-Sep =
   0 for SF2 (vs ~42 kWh/month for SF3 range cooker).

3. `_section_12_4_4_hw_blend(...)` — returns the 5-tuple
   (annual_hw_fuel_kwh, blended_cost_gbp_per_kwh, blended_co2_factor,
   blended_pe_factor, extra_standing_charge_gbp). The blend is kWh-
   weighted across:
   - Winter Oct-May: boiler fuel at the boiler's Table 32 unit price /
     Table 12 annual CO2 / Table 12 annual PE factor
   - Summer Jun-Sep: standard electricity (Table 12d/12e monthly
     factors weighted by summer (62)m demand) priced at the tariff's
     off-peak low rate per Table 13 note 2 (the 6.8 - 0.036V × N -
     0.105V dual-immersion formula clamps to zero high-rate for
     normal V/N combos on tariffs with ≥18 hrs low rate; SF2 has
     V=110, N≈2 → 100% low-rate)
   - The Table 32 off-peak electric standing charge that fires when
     hot water uses off-peak electricity per Table 12 note (a). For
     EIGHTEEN_HOUR tariff this is Table 32 code 38 = £40.

4. Orchestrator (`cert_to_inputs`) resolves the blend once and overrides
   `hot_water_kwh_per_yr`, `hot_water_fuel_cost_gbp_per_kwh`,
   `hot_water_co2_factor_kg_per_kwh`, `hot_water_primary_factor`, and
   `standing_charges_gbp` when the predicate fires. Other certs fall
   back to the existing single-fuel HW helpers (no behaviour change).

Worksheet evidence (heating-systems corpus property 001431 SF2 — code
158 + WHC=901 + cylinder thermostat + 18-hour tariff):
  - (62) Oct-May = 2205.80 kWh, Jun-Sep = 684.55 kWh
  - (217)m = 65 winter / 100 summer, (219) = 3393.5 anthr + 684.55 elec
    = 4078.06 fuel kWh
  - (247) HW cost = 4078.06 × 4.27 p/kWh blended = £174.25
  - (251) Standing = £40 (off-peak electric standing only — solid fuel
    has no standing charge)
  - (255) Total = £801.13

Closures (SF2):
  ΔSAP_c   +1.86 → -0.0000  (EXACT)
  Δcost   -£42.84 → -£0.00  (EXACT)
  ΔCO2  +346.87  → -93.10 kg/yr (residual: Elmhurst CO2 blend uses a
                                  different summer-month weighting that
                                  the SAP 10.2 Table 12d cascade does
                                  not reproduce — spec-correct per
                                  Table 12d header).
  ΔPE   -605.76  → -1027.51 kWh/yr (same spec-vs-Elmhurst PE blend
                                     artifact via Table 12e monthly
                                     cascade).

No regressions: 40/41 corpus variants unchanged (gate is narrow by SAP
code 156/158). Extended handover suite 898 pass / 0 fail. Pyright net-
zero (43 → 43).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
0001c7d11f Slice S0380.153: SAP 10.2 Table 3 — not-separately-timed DHW for solid-fuel boilers
SAP 10.2 Table 3 (PDF p.160) provides three primary-loss rows keyed off
the DHW timing arrangement, the middle row giving winter h=5 / summer
h=3 for "Cylinder thermostat, water heating NOT separately timed".

Solid-fuel boiler systems (Table 4a codes 151-161 — independent boilers,
open-fire + back boilers, closed room heaters with boilers, range cooker
boilers, stoves with boilers) do not ship with dual programmers. Per
SAP 10.2 §9.2.4 (PDF p.27) these are "independent solid fuel boilers,
open fires with a back boiler and room heaters with a boiler" — the
appliance itself is the timer. DHW timing follows the burn schedule,
not a separate cylinder programmer, so the middle Table 3 row applies.

Pre-slice `_separately_timed_dhw` returned True for any cylinder +
non-electric HW fuel cert (the S0380.140 gate), routing solid-fuel
boilers through h=3 year-round (the third row, "Cylinder thermostat,
water heating separately timed"). That under-counted winter (59)m
by ~21 kWh/month × 8 winter months across the affected cohort, with
the under-counted water-heating gain propagating into MIT / SH / SAP.

New gate: `sap_main_heating_code in _TABLE_4A_SOLID_FUEL_BOILER_CODES`
(frozenset of {151, 153, 155, 156, 158, 159, 160, 161}) — added before
the existing cylinder-present fallback. The post-S0380.140 electric-
immersion / heat-pump / no-main branches are unchanged. Table 4b
liquid-fuel boilers (101-141) keep the True default — modern gas/oil
installations standardly include dual programmers and the worksheet
confirms `oil 1` / `oil pcdb 1..3` / `pcdb 1` are pinned exact at
h=3 year-round.

Worksheet evidence (heating-systems corpus property 001431):
  - solid fuel 3 (SAP code 160 range cooker boiler + WHC=901
    cylinder thermostat): worksheet (59)m winter = 64.58 (h=5, p=0)
    and summer = 41.92 / 43.31 (h=3, p=0). Cascade closes ΔSAP +0.30
    → −0.0000, Δcost −£6.84 → −0.00, ΔPE −214 → −0.00 (4-metric exact).
  - solid fuel 2 (SAP code 158 closed room heater + back boiler):
    same Table 3 fix narrows ΔSAP +2.06 → +1.86. Remaining ~1.86 SAP
    is the SAP 10.2 §12.4.4 immersion-in-summer rule for back-boilers
    (codes 156, 158) — the worksheet has summer (59)m = 0 because the
    Elmhurst P960 lodges `Summer Immersion: Yes` + the spec routes
    Jun-Sep HW through an electric immersion at η=100%. That's a
    bigger lift (monthly HW efficiency + fuel-split plumbing) and is
    a follow-up slice.

Other corpus variants: no impact (verified via cohort sweep). The
gate is narrow by SAP code so only the 2 affected variants move.

Extended handover suite: 897 pass / 0 fail (+1 from new AAA test).
Pyright net-zero (43 → 43, transient +1 fixed via `EpcPropertyData`
import on the new test's `_cylinder_epc_for` return annotation).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
a92b134237 Slice S0380.152: SAP 10.2 Table 3 — primary loss for solid-fuel back-boilers
SAP 10.2 Table 3 (PDF p.160) "Primary circuit loss" verbatim:

  "Primary circuit loss applies when hot water is heated by a heat
   generator (e.g. boiler) connected to a hot water storage vessel
   via insulated or uninsulated pipes (the primary pipework)."

The spec rule does NOT restrict to Table 4b gas/oil boilers — any
boiler connected to a cylinder via primary pipework incurs the loss.
The cert's `water_heating_code` is the discriminator:

  - WHC=901/902/914 (HW from main heating system) + wet boiler +
    cylinder → primary loss applies (back-boiler / wet boiler heats
    cylinder via primary loop).
  - WHC=903 (HW from a separate electric immersion / secondary) → no
    primary loss even when the main is a wet boiler.

Pre-slice `_primary_loss_applies` only covered Table 4b gas/oil boiler
codes (101-141). Table 4a solid-fuel boiler codes 151-161 (manual /
auto / range-cooker boilers, closed room heater + back-boiler, open
fire + back-boiler, wood pellet + back-boiler) fell through and
primary loss silently went to zero — under-counting §5 (72) water-
heating internal gain by ~74 W cohort-wide for every WHC=901 solid-
fuel back-boiler variant.

Worksheet evidence on the 001431 corpus (all age G, same cylinder):
  - solid fuel 2 (code 158, WHC=901): ws (59) ≈ 505 kWh/yr   → apply
  - solid fuel 3 (code 160, WHC=901): ws (59) ≈ 643 kWh/yr   → apply
  - solid fuel 5 (code 153, WHC=903): ws (59) = 0            → skip
  - solid fuel 4..11 (633/636 non-boilers, WHC=903): skip

The fix:
  - `_primary_loss_applies(...)` gains a `water_heating_code: Optional[int]`
    parameter (default None for back-compat with synthetic tests).
  - New branch after the Table 4b fallback: `_is_wet_boiler_main(main)`
    + `water_heating_code in _WATER_INHERIT_FROM_MAIN_CODES` → True.
  - Call site `_primary_loss_override` passes
    `epc.sap_heating.water_heating_code`.

Heating-systems corpus impact:
  - solid fuel 3 (code 160, WHC=901): +1.31 → +0.30 SAP
                                       PE -918.6 → -214.3 kWh/yr
  - solid fuel 2 (code 158, WHC=901): +2.77 → +2.06 SAP
                                       PE -1241.7 → -754.1 kWh/yr
  - All other variants: unchanged

SF2 doesn't fully close because the worksheet's (59) is winter-only
(0 in summer) but the cascade applies the year-round Table 3 formula
via `_separately_timed_dhw=True` (cylinder + non-electric HW fuel).
Remaining residual is a follow-up — likely a
`_separately_timed_dhw=False` rule for solid-fuel back-boilers (HW
timing tied to the room fire, not separately programmed).

Pyright net-zero (43 → 43). Extended handover suite: 895 → 896 pass.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
2fea9c4ff5 Slice S0380.151: RdSAP 10 §4.1 Table 5 — extract-fans age-band default
RdSAP 10 Specification §4.1 Table 5 "Ventilation parameters" (PDF p.28)
verbatim — "Extract fans" entry:

  • Number of extract fans if known
  • If number is unknown:
      Not park home:
        Age bands A to E      all cases             → 0
        Age bands F to G      all cases             → 1
        Age bands H to M      up to 2 hab. rooms    → 1
                              3 to 5 hab. rooms     → 2
                              6 to 8 hab. rooms     → 3
                              more than 8 hab. rooms → 4
      Park home:
        Age band F            all cases             → 0
        Age bands G onwards   all cases             → 2

The Elmhurst Summary §12.0 renders "No. of intermittent extract fans: 0"
as the form for *unknown*; every other §2 chimney/flue line item follows
"number if known, or 0 if not present" and the cascade trusts the lodged
value verbatim. Only extract fans have a non-zero age-band default.

Pre-slice the cascade read the lodged 0 verbatim → cohort-wide -0.044
ACH ventilation deficit (= -2.6 W/K HLC, = -1.2% SH demand, = ~-0.3 SAP
per variant). All 25 cascade-OK corpus variants are age G + 4 habitable
rooms + not park home → Table 5 default = 1 fan.

New helper `_rdsap_extract_fans_default(age_band, habitable_rooms, *,
is_park_home)` + wiring in `ventilation_from_cert` applies
`max(lodged, table_5_default)` so the spec minimum fires when lodging
is below it.

Heating-systems corpus impact (25 cascade-OK variants):

  oil 1, oil pcdb 1/2/3            +0.27..+0.29 → EXACT (<1e-4)
  electric 1, solid fuel 5/6/7/8   +0.28..+0.43 → EXACT
  pcdb 1, ashp                     +0.41 / +0.18 → ±0.02
  electric 3/6/7/8/9, sf 4/9/10/11 +0.39..+0.60 → +0.08..+0.12
  electric 5                       -0.74 → -1.18  (Cluster B over-shoot)
  electric 2                       -0.24 → -0.46  (Cluster C HW gap)
  gshp                             +1.09 → +0.94  (Cluster C HW gap)
  solid fuel 2/3                   +3.08 / +1.76  → +2.77 / +1.31

Cluster A (cohort-wide HLC deficit) is closed. The four remaining open
fronts (Clusters B + C) are now visible without offsetting bugs:
  - Cluster B (Table 9c step 12 R sign): electric 5, solid fuel 2/3
  - Cluster C (HW kWh cascade): gshp + electric 2 (Appendix N3)
                                solid fuel 2/3 (Table 4b HW efficiency)

Golden-fixture re-pins:
  cert 0240 (age J, TFA 118): PE +2.18 → +5.80, CO2 +0.13 → +0.32
  cert 0390-2954 (age F, TFA 360): PE -28.27 → -27.97, CO2 -2.74 → -2.71

Pyright net-zero (44 → 44). Extended handover suite: 893 → 895 pass.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
f5e3c1bcea Slice S0380.150: SAP 10.2 §12 / Appendix F2 — 18-hour high-rate for pumps + lighting
SAP 10.2 §12 (PDF p.45 lines 2280-2283):

  "The 18-hour tariff is only for use with electric CPSUs with
   sufficient energy storage to provide space (and possibly water)
   heating requirements for 2 hours. Electricity at the low-rate price
   is available for 18 hours per day, with interruptions totalling 6
   hours per day, with the proviso that no interruption will exceed 2
   hours. The low-rate price applies to space and water heating, while
   electricity for all other purposes is at the high-rate price."

SAP 10.2 Appendix F2 (PDF p.63 lines 3809-3812):

  "F2 Electric CPSUs using 18-hour electricity tariff. The 18-hour
   low rate applies to all space heating and water heating provided
   by the CPSU. The CPSU must have sufficient energy stored to provide
   heating during a 2-hour shut-off period. The 18-hour high rate
   applies to all other electricity uses."

Table 12a Grid 2 omits 18-hour / 24-hour from its 7-hour / 10-hour
table; pre-slice the cascade's `_other_fuel_cost_gbp_per_kwh` fell
through Grid 2's `NotImplementedError` to
`prices.standard_electricity_p_per_kwh` (Table 32 code 30 = 13.19
p/kWh). Per §12 + Appendix F2 the 18-hour rule is explicit fraction =
1.0 at the high rate — pumps, fans, and lighting bill at the 18-hour
high rate (Table 32 code 38 = 13.67 p/kWh).

All 41 heating-systems corpus variants lodge `meter_type='18 Hour'`,
so this gap was cohort-wide. Pre-slice the cascade undercounted
pumps + lighting cost by (13.67 − 13.19) × kWh on every variant:

  oil 1            Δcost -£9.31 → -£6.69   (closed £2.62, pumps 265 +
                                            lighting 282 × £0.0048)
  oil pcdb 1/2     Δcost -£8.32 → -£6.29   (closed £2.03)
  oil pcdb 3       Δcost -£8.91 → -£6.29   (closed £2.62)
  pcdb 1           Δcost -£11.10 → -£9.07  (closed £2.03)
  ashp             Δcost -£5.57 → -£4.22   (closed £1.35, lighting only)
  electric 1..9    Δcost shift ~ -£1.35..+£1.35  (lighting only;
                                                  storage / room-heater
                                                  certs carry pumps_fans
                                                  = 0)
  solid fuel 4..11 Δcost ~ -£1.55 (lighting only)
  gshp             Δcost -£26.48 → -£25.12 (closed £1.35)

Pyright net-zero (43 → 43). Extended handover suite: 892 → 893 pass.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
0728aa1039 Slice S0380.149: Table 4f — circulation pump dispatch by pump age + wet-boiler gate
SAP 10.2 Table 4f (PDF p.174) "Electricity for fans, pumps and other
auxiliary uses" — Heating system circulation pump rows:

  Circulation pump, 2013 or later                 41 kWh/yr
  Circulation pump, 2012 or earlier              165 kWh/yr
  Circulation pump, unknown date                 115 kWh/yr

Pre-slice the cascade hardcoded `_PUMPS_FANS_KWH_BY_MAIN_CATEGORY[2]
= 160 kWh/yr` (115 Unknown CH + 45 gas flue fan) for category=2 gas
boilers and fell through to `_DEFAULT_PUMPS_FANS_KWH_PER_YR = 130`
for any other category. Both shortcuts ignored the per-cert
`central_heating_pump_age` lodging AND incorrectly applied
circulation pump electricity to dry electric storage / direct-acting
/ room heater systems (no primary water loop).

Implementation:

  - Mapper: `_elmhurst_pump_age_int` now recognises both "Pre 2013"
    and "2012 or earlier" string forms as the SAP10 enum 1 (Pre 2013).
    Pre-slice "2012 or earlier" silently returned 2 (2013 or later)
    on the entire oil corpus, mis-applying the 41 kWh post-2013
    circulation pump to certs that lodge "2012 or earlier" via
    Elmhurst Summary §14 "Heat pump age".
  - New `_is_wet_boiler_main(main)` gate: identifies wet-boiler
    systems by Table 4a/4b code range (101-141 gas/oil, 151-161
    solid fuel, 191-196 electric boilers), PCDB Table 322 record,
    or category ∈ {1, 2} fallback. Heat pumps (cat 4) return False
    per Table 4f note "Not applicable for electric heat pumps from
    database". Electric storage / direct / room heater codes
    (401-499, 601-699) return False — they have no primary loop.
  - New `_table_4f_circulation_pump_kwh(main)` dispatches on
    `central_heating_pump_age`:
        None / 0 → 115 kWh (Unknown date)
        1        → 165 kWh (Pre 2013 / 2012 or earlier)
        2        →  41 kWh (2013 or later)
  - New `_table_4f_main_1_gas_boiler_flue_fan_kwh(main)` extracts
    the gas-flue-fan 45 kWh logic from the old category dispatch.
    Gated on `_is_wet_boiler_main` + gas fuel + fan_flue_present.
  - Remove `_PUMPS_FANS_KWH_BY_MAIN_CATEGORY` and
    `_DEFAULT_PUMPS_FANS_KWH_PER_YR` constants (the new helpers
    replace both).

Worksheet evidence for the wet-boiler gate:

  electric 1 (code 191 electric boiler):   ws (230c) = 41 kWh ✓
  electric 5 (code 402 electric storage):  ws (231)  =  0 kWh ✗
  solid fuel 2 (code 158 anthracite):      ws (230c) = 41 kWh ✓
  solid fuel 9 (code 636 wood stove):      ws (231)  =  0 kWh ✗
  oil 1 (code 127 condensing oil):         ws (230c) = 165 kWh ✓
  oil pcdb 3 (PCDB 18573):                 ws (230c) = 41 kWh ✓

Cascade impact across heating-systems corpus (vs S0380.148 state):

  | Variant        | SAP Δ        | Cause |
  |----------------|--------------|-------|
  | oil 1          | +0.60→+0.40  | 165 + 100 = 265 ≡ worksheet exact |
  | oil pcdb 1/2   | -0.15→+0.36  | 41 + 100 = 141 ≡ ws exact |
  | oil pcdb 3     | +0.59→+0.39  | same |
  | pcdb 1         | -0.03→+0.50  | 41 + 100 = 141 ≡ ws (was over) |
  | electric 1     | -0.06→+0.45  | 41 (wet electric boiler) |
  | electric 3-9   | -0.1..-1.4→  | 0 (dry storage/UFH) |
  |                | +0.5..+0.6   | was 130 default; now 0 |
  | solid fuel 2-8 | various      | 41 (boilers) — partial closures |
  | solid fuel 9-11| -0.2→+0.5    | 0 (room heaters) — was 130 |

Re-pins reflect spec-correct application. Per
[[feedback-software-no-special-handling]]: pre-slice near-zero pins
were masking pre-existing offsetting cascade gaps; spec correctness
unmasks them.

Golden fixtures impact:

  - cert 0240 (dual oil combi, pump_age=0 Unknown): PE +2.52→+2.18
  - cert 0390 (Firebird PCDF oil, pump_age=0): PE -28.08→-28.27
  - cert 6035 (gas combi, pump_age=2 post-2013): PE +47.29→+46.42

Cert 6035 closer to zero (post-2013 41 kWh < pre-slice 115 unknown).
Cert 0240/0390 small shifts from removing the gas-cat-2 hardcoded
160 path for oil mains.

Tests:
  - test_sap_table_4f_circulation_pump_dispatches_per_central_heating_
    pump_age — asserts oil 1 inputs.pumps_fans_kwh_per_yr == 265
    (165 Pre 2013 + 100 liquid fuel) ± 1.0.
  - test_sap_table_4f_liquid_fuel_boiler_flue_fan_and_fuel_pump_adds_
    100_kwh (S0380.148) still passes.

Extended handover suite: 892 pass, 0 fail. Pyright net-improved
(removed unused `main_category` variable, file 33→32 errors).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
Khalim Conn-Kowlessar
3f68ec1f0d Slice S0380.148: Table 4f — liquid fuel boiler flue fan and fuel pump (100 kWh/yr)
SAP 10.2 Table 4f (PDF p.174) "Electricity for fans, pumps and other
auxiliary uses" row:

  Liquid fuel boiler — flue fan and fuel pump   100 kWh/yr  c) d)

Note c): "Applies to all liquid fuel boilers that provide main heating,
but not if boiler provides hot water only. Where there are two main
heating systems include two figures from this table."

Pre-slice the cascade's `_table_4f_additive_components` only wired:
  - (230a) MEV / MVHR
  - (230e) Main 2 gas-boiler flue fan (45 kWh)
  - (230g) Solar HW pump

The liquid-fuel sibling row was missing — oil 1 worksheet (230d) and
oil pcdb 3 worksheet (230d) both lodge 100 kWh/yr "oil boiler pump"
that the cascade was silently skipping.

Implementation:

  - Add `_LIQUID_FUEL_CODES = frozenset({4, 71, 73, 75, 76})` and new
    `is_liquid_fuel_code(fuel_code)` helper in
    `domain/sap10_calculator/tables/table_32.py`. Mirror of
    `is_electric_fuel_code` — routes through `_to_table_32_code`
    normalisation so Elmhurst-derived Table 32 codes (e.g. code 23
    = bulk wood pellets, solid) don't collide with API enum codes
    (where 23 = B30D community).
  - Extend `_table_4f_additive_components` to add 100 kWh for Main 1
    when `is_liquid_fuel_code(main.main_fuel_type)` returns True
    (`isinstance(int)` guard for the `Union[int, str]` field). Mirror
    the same gate for Main 2 per Note c) "Where there are two main
    heating systems include two figures".
  - LPG is GAS (Table 4b/4f convention, Ecodesign classification) —
    `_LIQUID_FUEL_CODES` deliberately excludes 2/3/5/9 LPG codes.

Cascade impact across heating-systems corpus:

  | Variant   | SAP Δ       | Cost Δ      | PE Δ        |
  |-----------|-------------|-------------|-------------|
  | oil 1     | +1.18→+0.60 | -£27→-£14   | -276→-124   |
  | oil pcdb 1| +0.42→-0.15 |  -£10→+£3.4 |  -84→+67    |
  | oil pcdb 2| +0.42→-0.15 |  -£10→+£3.4 |  -84→+67    |
  | oil pcdb 3| +1.16→+0.59 | -£27→-£14   | -271→-120   |
  | pcdb 1    | +0.57→-0.03 | -£13→+£0.6  | -109→+42    |

Cohort closures: pcdb 1 EXACT (-0.03), oil pcdb 1/2 closed to -0.15.

Golden fixtures impact:

  - cert 0240 (dual-main oil combi 130): SAP integer 73→72 (resid
    +0→-1), PE +1.02→+2.52, CO2 +0.11→+0.14. Dual-main certs add
    2 × 100 = 200 kWh aux per Note c). Cert's published SAP 73
    suggests the dual-main Q_space split (main_heating_fraction)
    may also need wiring — slice candidate.
  - cert 0390 (Firebird PCDF 9005 oil combi): PE -28.50→-28.08
    (CLOSER to zero), CO2 -2.75→-2.73 (CLOSER to zero), SAP +7
    unchanged.

Test:
  test_sap_table_4f_liquid_fuel_boiler_flue_fan_and_fuel_pump_adds_
  100_kwh — asserts oil pcdb 3 inputs.pumps_fans_kwh_per_yr ≥ 230
  (130 base + 100 liquid fuel boiler aux).

Extended handover suite: 891 pass, 0 fail. Pyright net-zero (44=44).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00