Task 9d271e98-96e6-4be6-bb50-e9be6f954003 (portfolio 796) failed property
715358 with "SapHeating: missing required field 'cylinder_size'": cert
0685-2881-6867-9029-1761 lodges has_hot_water_cylinder="false" but omits
sap_heating.cylinder_size entirely. Mirrors the already-handled inverse
gap in _normalize_sap_schema_16_x, so default to code 1 ("no cylinder")
rather than fail loud.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Foundation for PRD #1555: runs each PAS Hub site-note PDF through the
extractor -> EpcPropertyData -> Sap10Calculator and gauges the computed
SAP against pashub's own SAP-10.2 `pre_sap` (from hubspot_deal_data).
- test_pashub_sap_accuracy.py: hybrid gate. Per-fixture "must compute"
(xfail on the known in-progress mapper gaps MissingMainFuelType /
UnmappedSapCode / UnmappedPasHubLabel) + aggregate within-0.5 ratchet
floor, mirroring test_sap_accuracy_corpus.py.
- 205 image-stripped site-note PDFs + manifest.json. Images stripped so
the repo footprint stays ~52MB while the text layer the extractor reads
is byte-identical.
- build_pashub_accuracy_fixtures.py: provenance/rebuild from S3 +
hubspot_deal_data.
All 206 currently xfail on the known heating-string mapper gaps; each fix
(#1556-1568) flips its fixtures to computing and ratchets the floor.
Refs #1555#1568
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
`from_site_notes` copied the raw `party_wall_construction_type` survey
label onto the building part; the calculator read `None` and applied the
U=0.25 house default to every party wall — phantom heat loss on the
~165/205 solid party walls that RdSAP 10 Table 15 rates U=0.0.
Add `_pashub_party_wall_construction_int` (mirroring `_pashub_main_fuel_code`)
mapping the six surveyed labels to the SAP10 codes `u_party_wall` consumes,
strict-raising `UnmappedPasHubLabel` on an unknown label, and wire it into
both site-note building-part mappers. On the Guinness GMCA cohort this
halves the systematic SAP under-rate (mean signed -1.58 -> -0.85).
Refs #1559
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
_map_sap_heating resolves the raw emitter label (e.g. Radiators) to its
SAP10 emitter code via _pashub_heat_emitter_code, reusing the Elmhurst
emitter map. Blank passes through; an unrecognised label strict-raises
UnmappedPasHubLabel at the mapper boundary (ADR-0015) instead of
resurfacing as the calculator's UnmappedSapCode: heat_emitter_type.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Sets HISTORIC_EPC_S3_ROOT, the env var the handler reads to build the historic-EPC
reader. With it set, an EPC-less Property whose expired pre-2012 certificate is in
the backup has its prediction conditioned on that certificate and persisted as
source="expired" rather than "predicted" — which is what lets reporting tell "no EPC
at all" apart from "only an expired one".
The bucket comes from the shared remote state rather than a rebuilt string:
`retrofit_sap_data_bucket_name` is — despite the name — the retrofit-data-<stage>
bucket (shared/main.tf:167), and engine and fast-api already read it from that output.
modelling_e2e was the outlier hardcoding "retrofit-data-${var.stage}".
No IAM change: modelling_e2e_s3_read already grants GetObject + ListBucket across the
whole retrofit-data-<stage> bucket, which covers historical_epc/.
Note this makes 'expired' rows start appearing once deployed. assessment-model's
epcSources.ts joins only 'lodged' and 'predicted', so until it addresses the predicted
slot — source IN ('predicted','expired') — an 'expired' row matches neither and the
home drops out of both the "Homes Without an EPC" and "Expired EPCs" cards.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
test_lambda_image_copies_full_import_closure caught this: importing the Historic
EPC S3 repo drags datatypes/epc/domain/historic_epc_matching.py into the handler's
init-time closure, and that reaches back into the legacy address matcher —
backend/address2UPRN/scoring.py and utils/pandas_utils.py. The image COPYed
neither, so the Lambda would have died at cold start with Runtime.ImportModuleError.
Copied file-by-file rather than `COPY backend/ backend/`: backend/ is the whole
legacy engine and the closure needs only these seven files. Their third-party
deps (pandas, requests) are already in requirements.txt, so no new pip installs.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
ADR-0054 gives a prediction conditioned by an expired Historic EPC the source
"expired", so reporting can tell "no EPC at all" apart from "only an expired
one". It was implemented in IngestionOrchestrator — but the pipeline that
actually runs is modelling_e2e, which predicts through its own _predict_epc and
never adopted it. Result: zero `expired` rows have ever been written, and
`epc_property.source` holds only 'lodged' and 'predicted'.
Two things kept the flavour unreachable here, and both had to go:
- _predict_epc never looked at the historic backup at all, so no prediction
was ever conditioned.
- _flush_writes passed the literal source="predicted", and _PropertyWrite had
no field to carry a flavour, so one would have been dropped before the write
even if computed.
_predict_epc now mirrors IngestionOrchestrator._predict: the expired cert's
stable attributes fill the gaps Landlord Overrides left (overrides still win
where both speak) and condition the cohort, and it returns the source alongside
the EPC. _PropertyWrite carries it; _flush_writes persists it. save_batch
already groups deletes by source family, so a mixed predicted/expired batch
clears the shared slot correctly.
Ships dark: the reader is built only when HISTORIC_EPC_S3_ROOT is set, so
without it every prediction stays plain "predicted", exactly as today.
DEFAULT_S3_ROOT names the dev bucket, so defaulting to it would have a prod
lambda silently reading dev data — Terraform sets the var per environment.
Note this also rescues properties that currently fail to model outright: an
expired cert can supply the property_type no override resolved, where today
that raises UnresolvedPropertyTypeError.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
inspection_date is non-null on epc_property, so it is a better winner for
a shared-UPRN collision than insertion order: the latest-surveyed lodged
row wins. id DESC stays as the deterministic secondary, so a same-UPRN,
same-inspection_date tie falls to the highest id.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
An epc_property row can carry a null property_id (FE/historic ingestion
persists EPC rows never linked to a property row), so a property_id-keyed
read silently misses them. UPRN is the durable key both the property row
and the epc_property row share. Repoint the lodged reads (get_for_property
+ get_for_properties) onto UPRN; the predicted reads stay on property_id
because a predicted EPC deep-copies a neighbour's UPRN, so its UPRN column
is never the property's own.
UPRN is not unique on epc_property, so the read tie-break is now load-
bearing (it was dormant under property_id, where the write path guarantees
one lodged row per property): the most recently ingested (highest-id) row
wins. Write path stays keyed on (property_id, source).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Locks the gate edges — a lodged pitched loft below 270mm is recommended, a
loft at 270mm is left alone, and the 'Nmm+' form ('300mm+') parses to its
number and stays ineligible. These passed on arrival (they fell out of the
numeric-parse gate added in the previous commit); pinned as regression guards.
ADR-0063.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
A lodged numeric loft depth below the 270mm building-regs compliance gate is
now eligible (topped up to the 300mm install depth), regardless of whether the
roof type is lodged, since a measured depth is a positive statement of a real
loft. Sentinels keep their ADR-0047 resolution. Fixes property 724702 (50mm
loft) which previously returned no recommendation. ADR-0063.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The roof generator offered loft insulation only when genuinely uninsulated
(ADR-0021), so a loft with a shallow lodged depth (e.g. 724702's 50mm) got
nothing and never entered the optimiser pool. Grilled with Khalim: the loft
branch becomes eligible when the lodged depth is a known numeric value below
the 270mm building-regs compliance gate, topped up to the 300mm install depth.
Numeric-lodged-depths only; sentinels keep their ADR-0047 resolution. Loft
branch only. CONTEXT 'Roof Insulation Eligibility' updated to match.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Properties 741843/741872 (uprns 100060714155/100021944594) failed
modelling_e2e subtasks 6ac7841a-9338-4efe-97e5-7e0d19b3055d and
c5450f03-5b0d-4068-a3b3-d1470bc0af57 with a bare StopIteration: their
SAP-Schema-15.0 (2011-era LIG-lodged) certs identify the main dwelling's
building part as "Main building" rather than "Main Dwelling", so
from_api_string fell to OTHER and left the property with no MAIN part —
crashing wall_recommendation.py's unguarded next(...).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Thread the UPRN the PashubService has already resolved for a job into the
PasHub site-notes mapper so the EpcPropertyData aggregate is born with its
uprn set, and the existing save_epc_property_data path persists it.
- EpcPropertyDataMapper.from_site_notes gains uprn: Optional[int] = None and
sets it unconditionally (site notes never carry a UPRN natively).
- parse_site_notes_pdf / _parse_pashub forward the uprn; the Elmhurst branch
is untouched.
- PashubService coerces uprn str -> int in one place, carries it on the
internal upload record, and passes it into parse_site_notes_pdf.
- No new lookups; jobs with no known UPRN still persist null, unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The prior commit derived a Python bool (`cylinder_size != 1`), but
`from_rdsap_schema_17_1` reads the field via `schema.has_hot_water_cylinder
== "true"` — every real 15.0/16.x fixture lodges the lowercase string
"true"/"false", not a JSON boolean. A bare bool compares False against
that string check either way, so the derivation silently mapped every
cylinder-present cert to has_hot_water_cylinder=False too.
Caught by the requested true-branch test (mutating sap_16_2.json, which
lodges cylinder_size=2/has_hot_water_cylinder="true", to omit the field)
— it failed under the original bool-typed fix. Now emits "true"/"false"
strings to match the lodged convention.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Task b9fcd354-2a33-4fc4-a64e-388c060a055c (portfolio 824 / scenario 1278)
also failed property_id 749229 (UPRN 100010349400) with "RdSapSchema17_1:
missing required field 'has_hot_water_cylinder'". Cert
9568-3034-6211-6089-5960 (SAP-Schema-15.0) lodges `sap_heating.cylinder_size`
but omits the separate top-level `has_hot_water_cylinder` boolean
RdSapSchema17_1 also requires.
Unlike `multiple_glazed_proportion` (deliberately left un-defaulted a few
lines above — a prior guessed default regressed the accuracy gate),
`cylinder_size` isn't a proxy needing inference: RdSAP 10 Table 28 defines
code 1 as "no cylinder" — literally the same fact `has_hot_water_cylinder`
encodes. Confirmed 1:1 across every real 15.0/16.x fixture that lodges both
fields (cylinder_size == 1 <-> false, every other code <-> true).
Added to the shared `_normalize_sap_schema_16_x`, so it covers the whole
15.0/16.0/16.1/16.2/16.3 reduced-field family, not just 15.0.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>