Even after batching the data writes, the handler still wrote to the DB per
property through the orchestrator's SubTask bookkeeping: create + start +
complete each self-committed, and _cascade re-listed every sibling and re-saved
the parent on every transition — ~5 writes per property plus an O(N^2) cascade.
- TaskOrchestrator.run_subtasks: create all children in one INSERT, run each
(failures isolated per child), then persist all terminal states in one bulk
save and cascade the parent once. Children go WAITING -> terminal; the
transient IN_PROGRESS row is never written.
- SubTaskRepository.create_many / save_many (bulk INSERT / bulk fetch + update).
- _cascade short-circuits when the Task is already FAILED (terminal) — skips the
sibling roll-up entirely.
- modelling_e2e handler fans out via run_subtasks instead of per-property
create_child_subtask + run_subtask.
Per N-property batch the SubTask bookkeeping drops from ~5N writes + an O(N^2)
cascade to ~2 writes + 1 cascade.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The handler fired ~2+2N read round-trips and N+N write transactions per
SQS batch, pinning RDS CPU under ~32 concurrent containers on pool_size=1.
Reads: merge the duplicate property query and add overrides_for_many /
SolarRepository.get_many so overrides, solar, and property rows each load
in one query (2+2N -> 3).
Writes: buffer each modelled property's persistence intent in memory
(_PropertyWrite) during the loop, then flush the whole batch in one
PostgresUnitOfWork with a single commit, and run the baseline orchestrator
once for all written ids (N+N -> 2 transactions). Per-property modelling
failures stay isolated in the loop; the batch write is all-or-nothing and
retried via SQS (saves are idempotent upserts).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
An Economy-7 storage dwelling now prices heating at the 0.20-day/0.80-
night blend through cert -> calculator -> bill, instead of raising
UnpricedFuel and aborting the modelling_e2e batch.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Surface the hot-water (Table 13 / HP-DHW), secondary (direct-acting),
main-2 and ALL_OTHER_USES High-Rate Fractions on CalculatorInputs from
the same Table 12a helpers the SAP cost path uses, so Bill Derivation's
day/night split matches the rating's exactly.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The modelling_e2e Lambda runs on a single-connection pool (pool_size=1,
max_overflow=0) so one invocation uses one Postgres connection. But re-hydrating
a Property through PostgresUnitOfWork resolved its Landlord Overrides through a
PropertyOverridesPostgresReader built from the unit's session *factory* — which
opens a brand-new Session per call. While the unit's own read transaction was
still open (PropertyPostgresRepository.get_many had checked out the connection),
that second Session asked the pool for a second connection, found none, and timed
out after 30s:
QueuePool limit of size 1 overflow 0 reached, connection timed out, timeout 30.00
The baseline stage (PropertyBaselineOrchestrator.run -> uow.property.get_many ->
landlord overrides) hit this on every invocation.
Read the overrides on the unit's OWN session instead. property_overrides is
committed reference data, so reading it inside the unit's transaction sees the
same rows and keeps the invocation on one connection. Extract the query/mapping
into a shared helper and add OpenSessionPropertyOverridesReader (reads on a
caller-owned, already-open session without closing it) for the unit; the
standalone PropertyOverridesPostgresReader still opens its own short session for
use outside a unit.
Regression test pins the invariant with a real pool_size=1/max_overflow=0 engine:
without the fix it reproduces the exact QueuePool timeout.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The modelling_e2e Lambda held up to ~4 concurrent Postgres connections per
invocation: the read Session stayed open across the write loop (the catalogue
was queried live and overrides were read per-Property), each per-Property Unit
of Work opened a second, and the TaskOrchestrator ran on its own NullPool
engine — so the pool needed pool_size=2 + max_overflow=1 just for the modelling
work. Under 32 concurrent containers that approached RDS max_connections.
Restructure the handler to read everything up front — overrides, Scenario, an
in-memory catalogue snapshot, and stored Solar — through one short-lived read
Session, close it, then write each Property in a sequential Unit of Work. The
read and write Sessions no longer overlap, so the engine drops to pool_size=1,
max_overflow=0. Fold the orchestrator onto the same pooled engine: its repos
commit on every save, releasing the connection between bookkeeping calls, so it
holds none during the work. One invocation now uses one connection at a time.
The catalogue becomes a per-invocation snapshot (MaterialSnapshotRepository),
mirroring ProductPostgresRepository.get exactly — same drift mapping, lowest-id
pick, and errors — but priced after the Session closes. Transaction isolation
is preserved: per-Property writes and orchestrator bookkeeping keep their own
independent transactions, just drawn sequentially from a single connection.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
_predict_epc returned None for three unrelated causes — unresolved
property_type, an empty same-type cohort, and a degenerate (no MAIN part)
prediction — which the handler collapsed into one generic "not predictable"
string. The SubTask output could not say which cause fired or which data to
fix.
Raise a specific PropertyNotModellableError subclass per cause, each carrying
the property's identity (property_id, uprn, postcode, portfolio_id) and
cause-specific context. The unresolved-property-type message points at the
likely missing/contradictory Landlord Override. All subclass ValueError, so the
per-property failure boundary keeps catching them and records str(exc).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Fail if any EpcPropertyData field is neither reconstructed by _compose nor on a
documented allow-list, turning latent persistence gaps into explicit decisions
(would have caught the conservatory and roof-window drops). ADR-0036.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Persist SapConservatory as five nullable conservatory_* columns on epc_property
(1:1 with the dwelling) and rebuild it in _compose, so the §6.1 fold survives
save -> reload -> score. Without this the scored (re-hydrated) EPC silently
dropped the conservatory (persist != score) — a latent gap shared with the
21.0.1 path. Adds a deep-equality round-trip test. ADR-0036.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A predicted EPC is seeded by deep-copying one representative neighbour's
structure. _template chose the member whose floor area was closest to the
cohort median, ignoring building-part labels. When that member's only part
was lodged with a null identifier (mapped to OTHER), the prediction had no
MAIN part and the modelling_e2e handler rejected it as "not predictable" —
discarding an otherwise-rich same-type cohort.
Restrict the template to MAIN-bearing members (median still over the whole
cohort); fall back to closest-on-size only when none are MAIN-bearing, so an
all-unlabelled cohort is left for the handler's MAIN-part guard to reject
rather than silently relabelling real data.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).
Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.
Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).
Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.
Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):
- Override overlay *completes* the partial system the landlord named. Companion
fields are now DERIVED from the SAP code, not hand-attached per archetype: the
off-peak meter from the calculator's single off-peak classification (new
OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
charge control defaults to the conservative manual control (Table 4e 2401). So
adding a heating archetype is just adding its code — companions can't be
forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
sap_heating cluster — the donor is already coherent.
Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.
Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A SAP-16.x cohort cert (9258-4062-7265-2844-7954) lodges a bare int building-
part identifier (the second part as `1` after "Main Dwelling").
`BuildingPartIdentifier.from_api_string` regex-matched it assuming a string and
raised "TypeError: expected string or bytes-like object, got 'int'", failing the
whole property.
Fix: guard the match on `isinstance(api_identifier, str)` so a non-string
identifier falls to OTHER, matching the documented "anything unrecognised ->
OTHER" contract. The baseline SAP fabric sums all building parts regardless of
identifier, so OTHER is SAP-neutral; the identifier only labels parts for
measure targeting. Fixes every mapper (all route through from_api_string).
Cert now maps + calculates (sap 63). Regression test added.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2 modelling_e2e properties failed with KeyError: 'maxArrayPanelsCount'.
Google returns a `solarPotential` block with no array-level sizing fields
(`maxArrayPanelsCount` / `panelCapacityWatts`) for buildings with no usable
solar estimate. `SolarPotential.from_building_insights` hard-indexed those keys
and crashed the whole property.
Fix: the projection now returns Optional and yields None when those fields are
absent — the established "no solar potential" outcome (the orchestrator and
recommendation path already type it Optional and skip solar on None). Existing
callers (`_solar_potential_for`, harness) already assign to Optional.
Regression test + `assert is not None` narrowing on the valid-fixture tests.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
10 modelling_e2e properties failed with "unmapped SAP code in fuel_code: 10":
the billing layer (`sap_code_to_fuel`) had no carrier for Table-32 code 10
(dual fuel, mineral + wood) and raised rather than guess one.
SAP 10.2 treats dual fuel as its OWN fuel (its own Table-12 factors), so model
it as its own billing carrier rather than collapsing onto wood or coal:
- New `Fuel.DUAL_FUEL_MINERAL_AND_WOOD`.
- `_CODE_TO_FUEL[10]` -> that carrier.
- Fuel Rates snapshot prices it at 7.69 p/kWh — the midpoint of the COAL proxy
(7.13) and WOOD_LOGS (8.25). This mirrors SAP's own construction: Table-32
dual fuel (3.99) ~= midpoint of house coal (3.67) and wood logs (4.23).
Marked `derived` with a documented _note/_gap/_assumption (like the COAL and
HEAT_NETWORK proxies), since there is no retail blend price.
A dedicated carrier + rate (vs a one-line map to an existing carrier) keeps the
fuel identity faithful to SAP and avoids mispricing dual fuel as pure wood/coal.
Tests: code 10 -> DUAL_FUEL carrier; snapshot prices it at 7.69; grid-export
codes (36/60) still raise (the genuine no-carrier case).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
TEMPORARY guard (remove once the SAP calculator's oil-heating under-score is
fixed): a predicted oil-boiler picture scores SAP 13/G against its own
synthesised recorded SAP of 50/E, so the optimiser overshoots goal C all the
way to band A and publishes nonsense.
A predicted EpcPropertyData carries its recorded SAP (energy_rating_current).
When the calculator baseline diverges from it by more than ~one band (20 SAP
points), withhold the Plan: raise inside the per-property loop so the existing
failure isolation drops just that property into `failures` and fails the
subtask, while every other property still models and persists. Lodged
Properties are untouched — they have a real recorded cert and the Rebaseliner
already owns this check.
Verified end-to-end against property 713406 (UPRN 100061849247): baseline 13.2
vs recorded 50 -> quarantined, no Plan written.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Adds the mapper-driven e2e cascade pin for "simulated case 50" (000565 semi,
electric storage main SAP 402 + portable electric secondary + MVHR + whc-903
DUAL electric immersion + 160 L cylinder, Economy-7). Routes the Summary PDF
through extractor + mapper + calculator like the other 000565 fixtures.
Locks in two off-peak fixes this case ground-truthed:
- the Table 13 HW high/low split applied to CO2/PE (commit 39ae2cf0), and
- the Table 12a Grid 2 MVHR fan fraction 0.71/0.58 (commit cd5113ab).
All 11 SAP-result fields reconcile to the U985 worksheet EXACTLY, including
the (272) rating CO2 2397.1237 — SAP 38.8426 (=39), cost £1317.0116, water
1668.0788 kWh, fans 315.6384 kWh.
Summary mirrored to the tracked fixtures dir so the test doesn't depend on
the unstaged `sap worksheets/` workspace.
pyright strict gate not run locally (pyright not installed in this container).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.
That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.
Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.
Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).
Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
16 modelling_e2e properties failed with "Effective EPC is missing
renewable_heat_incentive; cannot read baseline space-heating / hot-water kWh".
Baseline runs for predicted properties too (ADR-0031), reading space/water-
heating kWh off the EPC's lodged RHI block. Predicted EPCs deep-copy a neighbour
template that may carry no RHI, so `_require_rhi` hard-failed the whole subtask.
Fix: when the EPC has no RHI, fall back to the property's OWN computed figures
from the scored SapResult (space_heating_kwh_per_yr / hot_water_kwh_per_yr) —
more representative than a neighbour's lodged numbers. Only when there is also no
SapResult (the rebaseliner scored nothing) is there genuinely no demand to
record, and we still fail noisily. Lodged certs are unchanged (RHI still wins).
Regression tests: fallback-to-computed, and the no-RHI/no-result raise.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Adds the mapper-driven e2e cascade pin for "simulated case 52" (000565
semi + regular non-combi mains-gas boiler SAP 102 + 160 L foam cylinder
heated from the main, no cylinder stat, uninsulated primary pipework,
standard tariff). Routes the Summary PDF through extractor + mapper +
calculator like the other 000565 / 001431_case* fixtures.
This closes the last untested branch of the cylinder/water chain: the
SAP 10.2 §4 cylinder storage loss (Table 2/2a/2b lines 51-55) + the
Table 3 PRIMARY circuit loss (59, uninsulated pipework + no stat) that
combi/immersion fixtures don't reach. All 11 SAP-result fields reconcile
to the U985 worksheet EXACTLY with no calculator change — SAP 57.2904
(=57), cost £911.1973, water 3929.7635 kWh — confirming the cylinder-loss
derivation is correct.
Summary mirrored to the tracked fixtures dir so the test doesn't depend
on the unstaged `sap worksheets/` workspace.
pyright strict gate not run locally (pyright not installed in this container).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>