Pin the FE-facing aggregate_portfolio_recommendations (previously untested): it
sums a Scenario's default Recommendations onto the Scenario row, joining
Recommendation → Plan on recommendation.plan_id. Locks the m2m→plan_id read cut
for the FE-critical path, now testable thanks to the full-parity ScenarioModel.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Move the scenario and installed_measure tables into
infrastructure/postgres/modelling/ as full-parity SQLModel definitions
(ScenarioModel, InstalledMeasureModel + MeasureType), completing the cluster
consolidation. backend/app/db/models/recommendations.py is now a pure
re-export shim.
ScenarioModel.goal is the PortfolioGoal enum (legacy planning branches on it),
sourced from domain/modelling/portfolio_goal.py; the repo's to_domain maps it to
its value string, so domain Scenario.goal is now the value ("Increasing EPC")
consistent with the orchestrator's check — fixing the latent name-vs-value
inconsistency the old str column masked (the scenario repo test stored the enum
*name*). Parity columns are nullable (mirror convention; live NOT-NULLs owned by
Drizzle).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PortfolioGoal is domain vocabulary (a Scenario's goal — legacy planning branches
on PortfolioGoal.INCREASING_EPC), so it belongs in domain/ co-located with
scenario.py, mirroring how domain/epc/wall_type.py holds an enum that
infrastructure/ imports. This lets the consolidated ScenarioModel (next slice)
source the goal enum from domain without an infra→backend dependency.
portfolio.py keeps a re-export so every existing
`from ...portfolio import PortfolioGoal` caller is unaffected.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Standardise the modelling persistence classes on the …Model suffix (PlanModel,
RecommendationModel, RecommendationMaterialModel) — matching the epc_property
precedent and the legacy names the rest of backend/ already imports, so the
shim's plan re-export becomes literal (no alias) and the eventual shim deletion
needs zero renames. The …Row→…Model sweep for the non-cluster tables
(Property/Task/Material/…) waits until their live legacy …Model counterparts
are retired, to avoid reintroducing dual-definition collisions. No behaviour
change.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Stop writing the m2m (remove create_plan_recommendations + its call, the bulk
link insert and the now-dead plan_ids_by_index, and the plan_recommendations
delete in delete_property_batch) and remove the PlanRecommendationRow model +
its shim alias and the test_export fixture inserts. Measures now link to their
Plan solely via recommendation.plan_id (writers set it, readers join on it).
The live drop of the plan_recommendations table is the FE-owned Drizzle
migration documented in docs/migrations/recommendation-plan-id.md, sequenced
after the read-cut + backfill.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Rewrite the three structurally-identical m2m-join readers
(portfolio_functions.aggregate_portfolio_recommendations,
Outputs.get_recommendations_from_db, export get_recommendations) to join
PlanModel directly via recommendation.plan_id, dropping the plan_recommendations
join and its now-unused import. The writers set plan_id (prior slice), so the
rows resolve. test_export pins the export reader through the cut (its fixtures
now set recommendation.plan_id). A portfolio_functions DB characterization test
lands with the scenario consolidation (which provides the full-parity scenario
table the aggregation writes to).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
upload_recommendations and bulk_upload_recommendations_and_materials now set
plan_id on each recommendation row (the plan id is already in scope), while
still writing the plan_recommendations m2m — the dual-write that lets readers
move onto plan_id with no breakage during the transition (ADR-0017 amendment /
docs/migrations/recommendation-plan-id.md). The m2m write is removed in a later
slice once no reader depends on it.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Move the live plan, recommendation, recommendation_materials and (retiring)
plan_recommendations tables into a new infrastructure/postgres/modelling/
subpackage as single SQLModel definitions (the epc_property pattern), absorbing
the rebuild's partial PlanRow/RecommendationRow mirrors and carrying full
legacy column parity plus recommendation.plan_id. Out-of-cluster references are
plain indexed ints (mirror convention); the live FKs are owned by the Drizzle
schema. backend/app/db/models/recommendations.py becomes a re-export shim
(ScenarioModel/InstalledMeasure stay for a later slice).
Fix the export conftest to create SQLModel-first (so Base funding_package's FK
to the now-SQLModel plan resolves) and skip the redundant drop_all on its
function-scoped throwaway DB (the epc enum type is now shared across both
metadatas). Resolves the pre-existing dual-definition collision: the rebuild
and legacy export suites are now co-runnable. No behaviour change.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds simulated case 7: case 6 (P960-0001-001431) with the heating swapped
to a CONDENSING OIL COMBI (SAP code 130, Table 4b 82/73) and the cylinder
removed — combi instantaneous DHW (WHC 901), Table 3a keep-hot combi loss
(61) = 600 kWh/yr, no primary/storage loss, boiler interlock PRESENT (no
−5pp). This is the heating archetype golden cert 0240-0200-5706-2365-8010
uses, which case 6 (SAP code 127, a *regular* condensing oil boiler +
cylinder) never exercised.
The cascade reproduces the case-7 worksheet EXACTLY at abs=1e-4 on every
top-level SapResult output with ZERO calculator changes:
(211) 7865.4304 (213) 7556.9821 (219) 3496.8121 (98c) 12646.3783
(255) 1123.3372 (257) 1.9631 (272) 5738.9315 (258) 73
This validates the SAP 10.2 Appendix D Eq D1 combi efficiency blend +
Table 3a keep-hot combi loss + Table 4b code 130 (82/73) path, and
exonerates the combi mechanism as the source of 0240's API-path residual
— which therefore lives in 0240's fabric/demand or the API mapper.
Test-only slice (no impl change). New fixture file: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Prerequisite for the SAP 10.2 p.186 two-systems-different-parts MIT.
When two main systems heat different parts of a dwelling, §14.1 Main
Heating2 lodges its OWN "Heat Emitter" + "Main Heating Controls Sap"
(simulated case 6: Main 1 radiators / control 2106 serving the living
area, Main 2 underfloor / control 2110 serving elsewhere). The extractor
+ mapper dropped both — `MainHeatingDetail.heat_emitter_type` and
`main_heating_control` came through as empty-string sentinels, so the
cascade saw system 2 as having no responsiveness (defaulted R=1.0) and no
control type.
- `MainHeating2` datatype gains `heat_emitter` + `heating_controls_sap`.
- The extractor reads them from the §14.1 block.
- `_map_elmhurst_main_heating_2` maps them via the same helpers as Main 1
(`_elmhurst_heat_emitter_int` → underfloor-in-screed = emitter 2, Table
4d R=0.75; `_elmhurst_sap_control_code` → 2110, Table 4e type 3),
threading the dwelling floor + age band for the underfloor subtype.
Empty-string fallback preserved for the legacy DHW-only Main 2 (cert
000565 §14.1 omits emitter/control). No cascade output changes yet — the
MIT consumer lands in S0380.205. Full suite 2358 pass + 0 fail.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst extractor crashed parsing simulated-case-6's room-in-roof
window rows: the §11 "Location" cell "Roof of Room in Roof" wraps across
the layout prefix/suffix blocks and leaked into the glazing-type phrase
("Double between 2002 Roof of Room and 2021 in Roof" → UnmappedElmhurst-
Label). Fix (`_parse_window_from_anchors`): detect the roof-of-room
location tokens, strip them from the before/after blocks so the glazing
phrase reconstructs cleanly, and set location="Roof of Room".
Mapper: `_is_elmhurst_roof_window` gains a "Roof of Room" location branch
(highest-confidence rooflight signal, above the BP-roof-type / U>3.0
gates); `_ELMHURST_ROOF_WINDOW_U_BY_GLAZING` gains "Double between 2002
and 2021" → 2.30 (case 6 lodges the already-inclined roof-window U, so
the +0.30 inclination adjustment must not double-apply).
This is the site-notes mirror of S0380.198 (API window_wall_type=4):
both paths now route room-in-roof rooflights to (27a) at the inclined U.
Validated against the case-6 P960 worksheet at abs=1e-4:
(27) Windows = 22.7408 (cascade 22.7407)
(27a) Roof Windows = 13.0375 (cascade 13.0375, EXACT)
(31) ext area = 336.13
Case 6 is pinned only on the §3 window line refs (new standalone test,
not added to the section-pin `_FIXTURES`) because its DUAL main heating
(51% rads + 49% underfloor, oil) makes the §10/§12 per-system lines
non-comparable to SapResult's aggregated fields — documented in the
fixture module. Summary mirrored to Summary_001431_case6.pdf.
Suite: 2355 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Promotes user-simulated "case 5" (detached, sandstone-walled, room-in-roof
cousin of golden cert 0240) to an e2e worksheet fixture pinning the WHOLE
extractor → mapper → calculator pipeline at abs=1e-4 on all 11 Block-1
line refs. Its worksheet prints the exact RR-gable routing S0380.196
implements, validating that fix against ground truth:
Roof room Main Gable Wall 1 15.68 U=0.35 (29a) Exposed → walls @ main-wall U
Roof room Main remaining area 61.73 U=0.30 (30) A_RR shell − Σ gables
External roof Main 14.52 U=0.11 (30) loft residual
Roof room Main Gable Wall 2 15.68 U=0.25 (32) Party → party @ 0.25
gable area = 6.40 × 2.45 (§3.9.1 default RR storey height); A_RR remaining
= 12.5√(83.2/1.5) − 2×15.68 = 93.09 − 31.36 = 61.73 (RdSAP 10 §3.9.1(e)).
Confirms a DETACHED dwelling can lodge a Party RR gable (Table 4 p.22
row 2) — so my S0380.196 mapping (gable_wall_type 0=Party, 1=Exposed) is
correct; do not flip it.
Two extractor/mapper gaps surfaced and fixed (case 5 is the forcing test):
- Sandstone wall label "SS Stone: sandstone or limestone" had no
`_ELMHURST_WALL_CODE_TO_SAP10` entry (raised UnmappedElmhurstLabel).
Added "SS" → 2 (WALL_STONE_SANDSTONE), matching 0240's API
wall_construction=2 (cross-mapper parity).
- Roof "Insulation Thickness 400+ mm" was silently dropped: the four
thickness parsers used `.split()[0].isdigit()`, which rejects the
trailing "+" → None → u_roof fell back to the age-J default 0.16
instead of 0.11 (+1.09 W/K roof, the whole 0.12 SAP gap). Added
`_parse_thickness_mm` (strips to leading digits) and applied it at all
four sites (walls / alt-wall / roof / floor). The only existing fixture
with "400+ mm" (000565 Stud Wall) routes via the RIR regex, unaffected.
Result: case 5 cascade ≡ worksheet at 1e-4 on SAP/ECF/cost/CO2 + every
energy stream. Neither gap affects 0240 (its API path captures both the
sandstone code and "400mm+"); 0240's residual is therefore non-fabric.
Suite: 2353 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated case-4 worksheet as e2e fixture `001431_6035` —
reproduces golden cert 6035's full floor geometry (Main ground-floor HLP
15.99 + first-floor HLP 8.32, the asymmetric upper storey) and 8 windows.
All 11 Block-1 line refs pin at abs=1e-4 against the worksheet (SAP 68,
ECF 2.2802, cost 937.2341, CO2 4682.3494, space 15745.3260, main fuel
18744.4357).
This is the 4th independent 1e-4 confirmation across the 6035 archetype
(sim cases 1-4). Case 4 matches 6035 on floors + window areas; the
residual ~50 kWh / £11 cascade delta vs 6035 is two lodged inputs only
(largest window orientation N vs S; meter type "Dual" vs API 2), not
calculator behaviour.
Conclusion: the cascade reproduces the spec engine exactly for 6035's
geometry, so 6035's +19 PE vs the lodged register is lodged-register
divergence (the gov.uk register's rounded value vs the spec-exact
worksheet), NOT a calculator gap. 6035 is a "pin-forever" lodged-only
cert. Bugs surfaced + fixed along the way: S0380.192 (Simplified-RR
remaining area) and S0380.193 (suspended-floor sealed rule).
2341 passed (+11), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated case-3 worksheet as e2e fixture `001431_rr8` —
Main + Extension + Simplified room-in-roof with 8 windows (≈14.15 m²,
reproducing golden cert 6035's glazing) and Main ground-floor HLP 15.99.
All 11 Block-1 line refs pin at abs=1e-4 against the worksheet (SAP 68,
cost 951.3425, CO2 4767.4862, space 16086.3557, main fuel 19150.4235,
HW 3307.2639, lighting 262.0885).
This is the third independent 1e-4 confirmation that the cascade
reproduces the spec engine for the 6035 archetype (after S0380.192
Simplified-RR + S0380.193 suspended-floor). It differs from 6035 in one
input only — the Main first-floor HLP (15.99 here vs 6035's 8.32) — so
6035's +19 PE vs the lodged register is lodged-register divergence, not
a calculator gap. A byte-identical 6035 replica (first-floor HLP 8.32)
would let 6035 itself be pinned directly to close that out.
2330 passed (+11), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §5 (PDF p.29) "Floor infiltration (suspended timber ground
floor only)", age band A-E, splits on whether a floor U-value is
supplied:
a) [U-value supplied] if floor U-value < 0.5 → "sealed", (12) = 0.1
b) [no U-value supplied] retro-fitted insulation → "sealed" 0.1;
otherwise "unsealed", (12) = 0.2
`_has_suspended_timber_floor_per_spec` fed the cascade's COMPUTED default
U into rule (a), so an as-built/uninsulated suspended-timber floor whose
default U happens to be < 0.5 was marked "sealed" (0.1) where Elmhurst
uses "unsealed" (0.2). That dropped (18) infiltration 0.85 → 0.75, (25)
effective ACH, HTC, and understated space heating ~450 kWh.
Fix: gate rule (a) on `floor_u_value_known` — a computed default U is not
a supplied value, so it falls through to (b). Verified against the
cert 001431 sim-case-2 worksheet: floor "As built", U=0.43 (matches the
worksheet's (28a) 0.4300 exactly), (12)=0.2 unsealed. Golden cert 6035
(also a suspended uninsulated floor) is unaffected — its U=0.63 ≥ 0.5
already routed to unsealed.
Promotes sim case 2 to the e2e harness as `001431_rr` (Main + Extension
+ Simplified room-in-roof — the 6035 archetype). All 11 Block-1 line
refs pin at abs=1e-4, locking BOTH this fix and S0380.192 (Simplified-RR
remaining area) end-to-end: SAP 69, cost 920.5046, CO2 4566.7090, space
15269.8593, main fuel 18178.4039. 2319 passed (+11), 0 failed; pyright
net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Summary PDFs preprocessed from `pdftotext -layout` wrap the windows-table
header across several lines. The third header line's tail ("U value / g
value / Draught Proofed / Permanent Shutters") tokenises to "value value
Proofed Shutters" and lands directly above the FIRST window's data row.
Because the first window in a building part has `before_start = 0`, its
prefix block reaches back into that header remnant. The remnant is
neither an orientation nor a building-part fragment, so it survived the
pops in `_compose_window_descriptors` and leaked into glazing_type as
"value value Proofed Shutters Double between 2002 and 2021" (windows 2-3,
whose prefix starts after the previous window's manufacturer line, were
clean).
Fix: the glazing-type phrase always starts with a glazing-start word
(Single/Double/Triple/Secondary), so trim any prefix fragments preceding
that word before joining the glazing type. Orientation/bp pops still run
on the full prefix, so they are unaffected.
Reproduced from `sap worksheets/Recommendations Elmhurst Files/
cavity_wall_insulation - main wall/before/Summary_001431.pdf`. Added a
regression test driving the real `_extract_windows_from_layout` path with
the verbatim tokenised header+rows. 2306 passed (+4), pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated 001431 case (the cert that drove S0380.189/.190)
as an Elmhurst-only e2e fixture: Summary PDF → extractor → mapper →
calculator, every Block-1 SapResult field pinned against the
P960-0001-001431 worksheet at abs=1e-4. All 11 pins pass with zero
residual — the case is clean, confirming the S0380.190 gas-combi fuel
derivation closes the Summary path natively.
Verified the handover's flagged "+0.0007 SAP" was a target artifact, not
a cascade gap: the worksheet displays ECF (257) rounded to 1.6047 and
integer SAP (258)=78; the cascade's continuous SAP is computed from the
UNROUNDED ECF = (255)*(256)/((4)+45) = 660.9750*0.4200/173.0, giving
77.6147 — which matches the worksheet's own unrounded value. Pinning the
continuous SAP from the display-rounded ECF (→ 77.6144) was the wrong
target. Block-1 line refs all match exactly: (211) 10699.7225, (219)
3327.1592, (231) 86.0, (232) 283.2229, (255) 660.9750, (272) 3000.1664,
Σ(98) 8987.7669.
Summary mirrored into the tracked fixtures dir as
Summary_001431_gas_combi.pdf (distinct name — the corpus reuses cert
001431 across every heating variant); source Summary + worksheet tracked
under sap worksheets/golden fixture debugging/ as the pin ground truth.
2302 passed (+11), 0 failed; pyright net-zero on new/changed files.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
CH6's P960 worksheet input lodges Distribution Loss = "Two adjoining
dwellings sharing a single heating system" → (306) DLF = 1.0000, vs CH4's
"Calculated" → 1.5 → (306) = 1.4500. That DLF choice swings SAP/cost/CO2/PE
materially, but it is NOT present in the Summary PDF that the corpus pipeline
consumes (Summary → ElmhurstSiteNotesExtractor → mapper → calculator).
Proven empirically with a user-supplied controlled pair (CH adjoined
dwellings/Summary_001431 (1) vs (2)): the two Summaries are byte-identical
across every RdSAP INPUT field, differing only in the derived header
(SAP 80 vs 75, bill £954 vs £1237, emissions 5.407 vs 7.394 t). A
case-insensitive scan of the CH6 Summary for "distribution"/"adjoin" returns
0 hits. Since CH4/CH6 Summaries are themselves identical bar fuel type, no
Summary-derivable rule can yield CH4=1.45 AND CH6=1.0.
Doc-only change (comment in _EXPECTATIONS); 20/20 community-heating corpus
tests pass. Closes the CH6 re-litigation: pin held.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b/13b (367)/(467) for a community heating
electric heat pump (Table 4a code 304 → Table 12 fuel 41 "heat from
electric heat pump"). The HP meters grid electricity, so per Table 12
note (s)/(t) + block 12b/13b footnote (a) its emission/PE factor is the
MONTHLY Table 12d/12e cascade (fuel 41 = standard-electricity profile),
weighted by the network heat profile, then × 1/heat-source-eff (1/COP):
(367)/(467) = [(307)+(310)] / COP × Σ((307+310)_m × factor_m)/Σ(...)
Per-line walk of CH3 (the displayed (367) 0.1535 / (467) 1.5717 are PDF
artifacts; the (373)/(473) totals reconcile only with):
CO2 factor = 0.15040 (monthly Table 12d wtd) vs cascade annual 0.136
PE factor = 1.55692 (monthly Table 12e wtd) vs cascade annual 1.501
Pre-slice the cascade routed code 304 through the non-electric branch
(`_co2_factor_kg_per_kwh(main) × 1/COP` = annual × scaling). New
`_is_heat_network_electric_main` (heat-network main whose fuel has a
Table 12d monthly set — i.e. fuel 41) routes all four factor helpers
(main + HW, CO2 + PE) through the monthly cascade × 1/COP. Non-electric
heat networks (gas 51 / oil 53 / coal 54) have no monthly set → annual
path unchanged (CH1, CH6 untouched).
Closure (CH3 was already SAP+cost EXACT):
CH3 (HP/Elec) CO2 −75.32→+0.0000 (= [(307+310)/3]×(0.1504−0.136)),
PE −249.32→−0.0000 (× (1.5569−1.501)) — FULLY EXACT
Corpus now 40/41 EXACT on all four metrics. Only CH6 remains: its
worksheet lodges a manual DLF=1.0 ("two adjoining dwellings") absent
from the Summary PDF (byte-identical to CH4 bar fuel type) — an
architectural limit, not a cascade gap. 2226 pass + 1 skip + 0 fail
(tolerances 1e-4 all metrics); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 §10b: hot water for a community-heating dwelling bills at the
heat-network rate, not the cert-lodged fuel. Elmhurst §15.0 lodges
`water_heating_fuel_type = "Mains gas"` (3.48 p/kWh) as a placeholder on
community certs; the worksheet (342) Water-heating cost = (310) × the
S0380.171 CHP heat-fraction blend — the SAME rate as space heating (340).
Per-line walk of the CH2 block 10b:
(340) space = 11837.83 × 0.037955 = 449.3047 (cascade EXACT)
(342) water = 3854.12 × 0.037955 = 146.2830 (cascade billed
3854.12 × 0.0348 = 134.12 → −£12.16, the whole residual)
(350) lighting + (351) standing → (355) 754.1502.
`_hot_water_fuel_cost_gbp_per_kwh`'s `inherit_main_for_community_heating`
path already routes HW cost through `_fuel_cost_gbp_per_kwh(main)` (the
CHP blend), but its gate `_is_community_heating_hw_from_main` excluded
code 302. S0380.182 wired the 302 CO2/PE credit via
`_heat_network_code_302_effective_factor`, which intercepts the HW
CO2/PE helpers ABOVE this predicate's branch — so extending the
predicate to include 302 now affects ONLY the cost path.
Closures:
CH2 (CHP/Gas) SAP +0.5277→−0.0000, cost −£12.16→−£0.00 — FULLY EXACT
CH4 (CHP/Oil) SAP +0.5277→−0.0000, cost −£12.16→−£0.00 — FULLY EXACT
CH6 (CHP/Coal) SAP −7.49→−8.02, cost +£172.68→+£184.84 — its HW now
also bills the blend, compounding the DLF=1.0 quirk
(cascade DLF=1.45); same separate CH6 DLF front.
Corpus now 39 variants EXACT on all four metrics (CH2/CH4 join). Open:
CH3 CO2/PE (code-304 community-HP COP), CH6 all-metric (DLF=1.0 manual
override the Summary doesn't carry). 2225 pass + 1 skip + 0 fail
(tolerances 1e-4 all metrics); pyright net-zero 32→32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 worksheet block 12b (CO2) / 13b (PE) for community heating
"CHP and boilers" (SAP code 302). Per unit of network heat fuel
H = (307)+(310) the effective generation factor is:
chp×100/(362)×f_fuel − chp×(361)/(362)×f_disp + (1−chp)×100/(367)×f_fuel
(363)/(463) CHP fuel = chp_frac × 100/heat_eff × f_fuel
(364)/(464) less credit = −chp_frac × elec_eff/heat_eff × f_disp
(368)/(468) boiler fuel = (1−chp_frac) × 100/boiler_eff × f_fuel
f_fuel = Table 12 heat-network fuel factor (the CHP unit and the back-up
boilers burn the same community fuel — verified vs CH2 gas / CH4 oil /
CH6 coal worksheets (363)/(368)); f_disp = Table 12f (PDF p.196) credit
for the CHP-generated electricity. RdSAP 10 §C (p.58) defaults: heat eff
50% (362), electrical eff 25% (361), boiler eff 80% (367); CHP heat frac
0.35 per-cert via community_heating_chp_fraction.
New `_heat_network_code_302_effective_factor` + Table 12f flexible
constants (0.420 CO2 / 2.369 PE) + RdSAP §C efficiency constants, wired
into all four factor helpers (main + HW, CO2 + PE) ahead of the existing
single-fuel / 1-over-heat-source-eff path. The worksheet (368)/(468)
boiler emissions DISPLAY rounded/mis-aligned in the PDF, but the
(373)/(473)/(386)/(486) totals reconcile only with the boiler at the
full Table 12 factor — verified EXACT.
Two spec citations applied:
- Table 12f flexible-operation default for RdSAP community CHP is an
Elmhurst engine choice (Table 12f notes make "standard" the default);
mirrored per [[feedback-software-no-special-handling]] and documented
in SAP_CALCULATOR.md §8.3.
- Table 12 heat-network oil/biodiesel CO2 (codes 53/56) corrected
0.298 → 0.335 per Table 12 (p.189) "assumes 'gas oil'"; the code-302
oil cascade (CH4) was the first to exercise it. PE 1.180 was already
correct. No other variant uses these codes (no regression).
Closures (CO2 + PE only — the CHP credit does not touch cost/SAP):
CH2 (CHP/Gas) CO2 −1411.49→+0.0000, PE +1331.23→+0.0000 EXACT
CH4 (CHP/Oil) CO2 −4378.24→−0.0000, PE +319.81→−0.0000 EXACT
CH6 (CHP/Coal) CO2/PE re-pinned (+2411.54 / +5023.48) — its worksheet
lodges a manual DLF=1.0 the Summary doesn't carry, so
cascade DLF=1.45 over-scales H; same root as the CH6
SAP −7.49 / cost +£172 (separate DLF front).
CH2/CH4 are now CO2+PE-exact but still carry the heat-network cost/SAP
residual (+0.5277 SAP / −£12.16 cost, exposed by S0380.175 — cost-side,
untouched here). CH3 unchanged (code 304 community-HP COP front).
Corpus state: 37 variants EXACT on all four metrics (incl. CH1);
remaining residuals are CH2/CH4 cost+SAP, CH3 CO2+PE (HP COP), CH6
all-metric (DLF quirk). 2223 pass + 1 skip + 0 fail (tolerances 1e-4 all
metrics per S0380.181); pyright net-zero 43→43.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>