`test_epc_property_data_round_trips[RdSAP-Schema-21.0.1]` failed with
`sap_roof_windows: None != []` — a normalization mismatch, not lost data.
The 21.0.1 fixture has no roof windows, but the 21.0.1 API mapper emitted
an empty list `[]` while the domain field defaults to None
(`Optional[List[SapRoofWindow]] = None`), the 21.0.0 path yields None, and
the persistence reload yields None (roof windows aren't stored yet — doc
§2.4). Append `or None` so "no roof windows" has one canonical
representation across mapper paths and the round-trip.
No data-loss change: a cert WITH roof windows still produces the
populated list (test_golden_fixtures pins a 6-roof-window cert), and the
§2.4 roof-window persistence gap remains separately tracked. Full
sap10_calculator + documents_parser + epc-repository suites pass (2420);
pyright unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the `_api_resolve_wall_insulation_thickness` tests
passed literals straight into the Act call. Bind them as named variables
in Arrange (`lodged_thickness`, `measured_value_mm`, `ni_lodgement`) and
have the asserts reference those names, so the Act line reads
declaratively and the inputs/expectations are stated once. Applied to all
three tests in the class. No behaviour change; tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the simplified room-in-roof branch used cryptic
locals. Rename for clarity (behaviour-unchanged; the geom dict keys and
the builder-function locals are untouched):
rr_a_rr -> rr_roof_area (the worksheet's simplified A_RR)
rr_common -> rr_common_wall_area
rr_gable -> rr_gable_area
a_rr_final -> rr_residual_roof_area (leftover roof-going area after
deducting perimeter walls/gables
/rooflights — takes the roof U)
Names now mirror the `rr_*_area_m2` geom keys they read from and say
"area of what". Added a one-line note that `rr_roof_area` is the RdSAP 10
§3.10.1 A_RR. Pyright unchanged; 1087 heat-transmission/cascade-pin tests
pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the SQLModel column was Optional[str], but the
domain `SapBuildingPart.wall_insulation_thickness` is Optional[Union[str,
int]] — `_api_resolve_wall_insulation_thickness` returns an int mm when the
API lodges `wall_insulation_thickness == "measured"` (SAP 10.2 §5.7 /
Table 8). The plain str column round-trips that int back as the string
"100", corrupting the Table 8 insulated-wall U-value lookup.
This column was missed in the round-trip-fidelity §1 JSONB sweep
(#1129) — its `Union[str, int]` sibling `roof_insulation_thickness` was
converted, but `wall_insulation_thickness` was not, and no 21.0.0/21.0.1
fixture lodges "measured" so the gap stayed latent. Convert to JSONB
(matching `roof_insulation_thickness` / `flat_roof_insulation_thickness`),
align the column type to Optional[Union[str, int]] (also removes a pyright
type-mismatch), record it in the migration doc §1, and add a round-trip
guard test asserting an int survives as an int (fails as '100' == 100 on
the old str column).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): `_parse_thickness_mm` handles a None input and
returns Optional[int], so its call-return locals — and the Optional[str]
raws they read from `_local_val` — read clearer when annotated. Annotates
`thickness_raw`/`ins_thickness_raw: Optional[str]` and
`thickness_mm`/`insulation_thickness_mm: Optional[int]` at all four call
sites (_wall_details_from_lines, _alternative_walls_from_lines,
_roof_details_from_lines, _floor_details_from_lines), plus the adjacent
`u_val_raw`/`default_u` Optional pair in _floor_details_from_lines for
consistency. Matches the project convention of typehinting call-return
locals. No behaviour change; pyright clean, 569 parser tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Captures the diagnosis so the next agent doesn't re-derive it: what's done
(S0380.235-237), what's confirmed correct (calculator U-adjustment, party
wall, glazing labels), the worksheet pin targets, and the two open causes —
crucially the 000516 trap (byte-identical Summary data classified as a roof
window there but a wall window here, so flipping the U>3 rule regresses
000516). Includes a rebuildable tracer recipe.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes the secondary-glazing family. S0380.235 mapped the unknown-data
(7) and normal-emissivity (11) secondary variants; the RdSAP-21.0.1
`glazed_type` enum also defines code 12 "secondary glazing, low
emissivity", whose Elmhurst §11 label "Secondary glazing - Low
emissivity" was unmapped and would strict-raise. Cascade code 12 carries
the same daylight/solar bucket as 7/11 (g_L=0.80, g⊥=0.76); the lodged
manufacturer U/g drive §3/§6. With this the double family (codes 1/2/3/
7/13 via their Elmhurst phrasings) and the secondary family (4/11/12) are
fully covered. Coverage test extended.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §3.3: "As Main Wall: Yes" makes an extension inherit the main
dwelling's external wall CONSTRUCTION only — the party wall type is
lodged separately per building part in the Summary §7 block and may
differ. `_extract_extensions` was copying `main_walls.party_wall_type`
into the inherited WallDetails, so every extension reused the main's
party wall U.
On the double_glazing fixture (Summary_001431) the Main lodges party
"CU Cavity masonry unfilled" (SAP10 wall_construction 4 → u_party_wall
0.5) but the 1st Extension lodges "U Unable to determine" (→ 0 → RdSAP
default 0.25). Pre-fix both building parts used 0.5, inflating worksheet
(32) party-wall heat loss by 6.56 W/K (Ext1 26.25 m² × 0.25). After the
fix worksheet (32) is exact: ours 32.573 vs worksheet 32.5725.
Now reads the extension's own "Party Wall Type" from its §7 chunk,
falling back to the main's only when the extension lodges none. Adds a
fixture + test asserting Main=4 / Ext=0 with distinct u_party_wall.
Suite 2413 pass; no cohort regression.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The double_glazing recommendation fixture (Summary_001431) exercises every
RdSAP-21 §11 glazing lodging in one cert; five labels were missing from
`_ELMHURST_GLAZING_LABEL_TO_SAP10` and strict-raised `UnmappedElmhurstLabel`:
"Secondary glazing" -> 7 (Table 6b "secondary glazing", g_L 0.80)
"Secondary glazing - Normal emissivity" -> 11 (RdSAP-21 secondary normal-E, g_L 0.80)
"Triple pre 2002" -> 10 (triple pre-2002, g_L 0.70)
"Triple with unknown install date" -> 6 (generic triple glazed, g_L 0.70)
"Single glazing, known data" -> 15 (single known-data, g_L 0.90)
The glazing code's only cascade effect is the §5 (66)..(67) daylight factor
g_L in `_G_LIGHT_BY_GLAZING_CODE` (single 0.90 / double+secondary 0.80 /
triple 0.70); the lodged manufacturer U-value and solar_transmittance drive
§3 / §6 directly (`_g_perpendicular` prefers the lodged value). Codes are the
semantically-exact RdSAP-21 rows within the correct g_L bucket, kept distinct
for the strict-raise audit trail. Adds a full-coverage test over all 13
distinct labels. Suite 2413 pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>