The PV-array (ea7f4f43) and electricity-tariff (6ec09892) mapper fixes shifted
the observed output of five frozen gates that weren't updated alongside:
- has_pv component-accuracy floor 0.9798 -> 0.9697: carrying full-SAP lodged PV
now reads the true has_pv=True for full-SAP PV dwellings, so the leave-one-out
scorer's actual changes (ground-truth-method shift, ADR-0037 pattern).
- uprn_10093116528 80->... pin 82 -> 83: tariff=1 (standard) was wrongly read as
dual/Economy 7; translating to "single" re-prices the gas semi's electricity.
- uprn_10096028301 82 -> 84, uprn_10023444324 80 -> 82 (== lodged 82),
uprn_10023444320 81 -> 83: now credit the lodged sap_energy_source.pv_arrays
the schema previously dropped. Comments document the per-cert PV/Elmhurst
relationship (incl. the mid-floor sibling landing +2 over its lodged integer).
Pre-existing, unrelated failures untouched: the missing
sap_16_0_full_no_floor_dims.json fixture and the RdSAP-21 floor-area test (both
reproduce on origin/main).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Electric room heaters (691) get a Dual meter from the overlay (not single-rate):
an all-electric room-heater dwelling realistically bills on Economy 7, and the
§12 dispatch then applies a high/low split rather than a single-rate over-penalty.
Overlay owns its assumed-meter policy via _ASSUMED_DUAL_METER_CODES (the §12
off-peak systems + room heaters), keeping OFF_PEAK_IMPLYING_HEATING_CODES pure.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP 10.2 Appendix N3.7 ("Thermal efficiency for water heating - heat pumps",
PDF p.109): "multiply the thermal efficiency for water heating by the in-use
factor in Table N8; subject to a minimum efficiency of 100%." Our
_heat_pump_apm_efficiencies applies the in-use factor but omits the floor.
Anchored to golden fixture case 56 (PCDB 100061, cert 100110101713): an
oversized HP (PSR 3.107) extends water,3 198.9% -> 128.55%, x 0.60 in-use =
77.13% < 100% -> the accredited Elmhurst worksheet (216) reads 100.0000, we
read 77.13%. In-range PSR keeps 0.60 x 198.9 = 119.34% (above the floor).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP 10.2 Appendix N2 (PDF p.101, footnote 44/45): for an air/ground/water
source heat pump whose plant size ratio exceeds the record's largest PSR,
the efficiency is reciprocal-interpolated between the largest-PSR value and
100% at twice the largest PSR (100% beyond that); below the smallest PSR the
efficiency is 100%. Our interpolator instead clamps to the top/bottom row.
Anchored to the accredited Elmhurst worksheet for cert 100110101713 (golden
fixture case 56, PCDB 100061): PSR 3.10665 over the record's largest 2.0
gives eta_space,1 = 147.011 -> (206) = 0.95 x 147.011 = 139.660, vs the
clamped 352.0 -> 334.4% that over-rates the dwelling by +18 SAP.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Gate PV generation/credit in cert_to_inputs on gov-API pv_connection:
credit only when ==2 ('connected'); ==1 ('present but not connected to the
dwelling's meter') contributes zero to the dwelling's cost/CO2/PE per
RdSAP 10 §11.1 / SAP 10.2 Appendix M. Non-int (None / site-notes str) keeps
the credit-if-array behaviour, so the Elmhurst/Summary + synthetic paths are
unchanged (no regression).
Corpus: all 5 pv_connection=1 PV certs move inside ±0.5 (e.g. 100051118081
+6.5→+0.5); MAE 0.760→0.740, within-0.5 73.8→74.3%, no regression
(pv_connection=2 certs keep their credit).
Also corrects a now-load-bearing latent bug: the solar-recommendation
overlay tagged recommended arrays pv_connection=1 ('not connected') — which
the new gate would zero. A new install connects to the dwelling's meter, so
it must be 2; pinned by the overlay test.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
RdSAP 10 §11.1 / SAP 10.2 Appendix M: PV is included in a dwelling's
assessment only if connected to the dwelling's own electricity meter. The
gov-API pv_connection enum encodes this — 0=no PV, 1=present-but-not-
connected, 2=connected. Corpus-validated (57 PV certs: pv_connection=1 MAE
4.48->1.22 without credit, 0/5 need it; pv_connection=2 needs it, MAE 0.98
vs 10.29) and Elmhurst-proven (connected SAP 87 vs not-connected 74).
cert_to_inputs currently credits a pv_connection=1 array; the test pins that
it must contribute zero generation. Adds pv_connection to make_minimal_sap10_epc.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A gov-API flat can lodge dwelling_type="Mid-floor flat" while carrying its
own exposed roof — a top-floor flat mislabelled mid-floor. _dwelling_exposure
keyed roof exposure on the dwelling_type label alone, dropping the roof
heat-loss term: space-heating demand under-read ~32%, SAP over-read +7.
Fix: when the main building part lodges a *determined* roof_insulation_location
(an RdSAP integer code, not the "ND" Not-Defined party-ceiling sentinel),
expose the roof regardless of a contradictory label. Structured field, not a
description string and not roof_construction (which the gov-API lodges
building-wide on every unit, so it is not a per-unit signal).
On the RdSAP-21.0.1 corpus roof_insulation_location separates the classes with
zero disagreement: all 190 party-ceiling flats lodge "ND"; the 4 mid/ground
flats this exposes all move toward lodged, 0 away. within-0.5 73.3% -> 73.6%,
MAE 0.774 -> 0.761 (ratchets tightened). Verified end-to-end on the same
block: 715363 (location 6, RHI 2694) 81 -> 74 = lodged; genuine mid-floor
sibling 715395 (location ND, RHI 1024) stays party at 83 = lodged.
The override is additive (only ever exposes a label-dropped roof) and reads
the main part, so multi-part flats with a party main ceiling stay party.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A gov-API cert can lodge dwelling_type="Mid-floor flat" while carrying a
real exposed roof element (roof_construction != 7 "dwelling above") over a
"(another dwelling below)" floor — i.e. a top-floor flat mislabelled
mid-floor. Property 715363 (uprn 6027561) + sibling 715395 (6027563) do
exactly this; the correctly-labelled top-floor sibling 715871 (6027574),
same block + same flat roof, already computes the lodged SAP 74.
_dwelling_exposure keys roof exposure on the dwelling_type label alone, so
it drops the roof heat-loss term, under-reading space-heating demand ~32%
(calc 1833 vs lodged RHI 2694) and over-reading SAP +7 (81 vs 74).
Pins the fix: a mid-floor label + lodged exposed roof must expose the roof
(floor stays party). Also corrects the existing mid-floor fixture to lodge
the party-ceiling code 7 (the default 4 is an exposed pitched roof).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Pin the hit-list properties: each property's real Landlord Override set still
resolves to overlays and trips physical_state_changed, and the rebaseliner
adopts the calculator output (reason physical_state_changed/both) rather than
echoing the lodged headline — so the displayed baseline and the modelled plan
agree. Scores a real cert through the live Sap10Calculator.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Add Property.physical_state_changed (true on Site Notes / Landlord Overrides
/ Prediction — trigger (b)/(c)) and pass it from the
PropertyBaselineOrchestrator into the Rebaseliner. So an overridden or
predicted SAP>=10.2 property now stores calc(effective) as its Effective
baseline instead of echoing the lodged headline — closing the "81 in the DB"
divergence between the displayed baseline and the modelled plan.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A SAP>=10.2 cert whose physical state was changed by Landlord Overrides or
Prediction must rebaseline off the calculator (the accredited lodged figure
no longer describes the dwelling) and tag physical_state_changed / both, and
must NOT log divergence (the calc IS adopted, nothing to validate against).
This is the D1 fix: the stored Effective baseline stops echoing the lodged
headline for overridden properties.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A Landlord heating-system override was applied as a sparse patch, so the
replaced system's fields bled through. A storage flat reclassified as a gas
combi (property 728513) kept mains_gas=False, heating category 7, the 2401
storage charge control, a Dual meter and an electric-immersion cylinder — an
incoherent record that gated out the gas-boiler-upgrade Measure and made the
heating Generator read the dwelling as off-gas (offering HHRSH storage).
Extend the ADR-0035 drag-along to gas boilers (Table 4b 102/104/120): the
overlay now sets the whole coherent companion set — mains_gas, gas main fuel,
heating category 2, fanned flue, full modern controls (2106), a single-rate
meter, and hot water from the main system with the cylinder set from the boiler
type (combi → none, regular/CPSU → cylinder). The main_fuel overlay also flips
mains_gas=True for a "mains gas" fuel. Non-off-peak archetypes now drag an
explicit Single meter so a system switch never leaves a stale Dual.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The heating-donor display synthesis reads donor.epc.main_heating, which has no
dataclass default — so a partial object.__new__ EpcPropertyData must set it.
test_validation's _comparable builder didn't, failing the two leave-one-out
scorer tests in CI (the full epc_prediction suite wasn't run pre-push).
main_heating_controls / sap_ventilation default to None via class attributes.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Three corrections found by re-running property 742003 end-to-end:
- roofSegmentStats are POSITIONAL — real responses omit the segmentIndex field
the fixture happened to carry; key the centre/area lookup by array position.
- Base the cap on ground_floor_area (the footprint the roof covers), not the
greatest per-storey area; roof_area is the fallback.
- Clamp the basis by total_floor_area: predicted EPCs borrow the structural
template's geometry (742003: a 118.62 m² MAIN ground floor) decoupled from
the predicted 55 m² (ADR-0029), so without the clamp the cap reads the
template's larger footprint.
Result: 742003 plan A/92.4 (16 kWp) -> C/74.4 (6.4 kWp). 29 solar tests +
orchestration threading + products green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
select_conservative_configs must accept the dwelling's roof area and cap panels
to its usable roof (ADR-0038) — bounding a 55m² dwelling to ~16 panels under
Google footprint conflation, while staying a no-op on correctly-matched homes.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
The Dwelling-Roof Cap (ADR-0038) sizes by usable roof area and ranks segments
by distance from the dwelling, so the projection must carry each panel's
footprint and each segment's centre + area (from roofSegmentStats).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Prediction never synthesises ventilation — it keeps the size-template's
sap_ventilation, so a predicted dwelling in an MEV/MVHR neighbourhood is scored
+ displayed as natural (predicted property 721167 follow-up). Mode the
mechanical_ventilation_kind across the cohort like glazing.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
_apply_heating_donor copies the donor's calc sap_heating but leaves the
display rows (main_heating, main_heating_controls) on the structural template
— incoherent, and 'Heating Control: Unknown' when the template lodged no
control (predicted property 721167, ADR-0029 follow-up).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Full-SAP certs mapped property_type=None, so the hard cohort filter silently
excluded them as comparables. Correctly typing them admits real lodged EPCs as
donors — a ground-truth-method change (cf #1245). Net over the n=36 fixture: 16
components better, 4 worse, 6 unchanged; gains concentrated in the physical
characteristics full-SAP certs measure (window_count 3.83->1.69, building_parts,
total_window_area, floor_construction, construction_age_band, glazing, walls).
The 4 that fell are new-build-vs-old-stock service mismatch on 1-2 targets each
(heating/water fuel, cylinder insulation) + floor_area. Tighten 16, loosen 4.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
An Economy-7 storage dwelling now prices heating at the 0.20-day/0.80-
night blend through cert -> calculator -> bill, instead of raising
UnpricedFuel and aborting the modelling_e2e batch.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Surface the hot-water (Table 13 / HP-DHW), secondary (direct-acting),
main-2 and ALL_OTHER_USES High-Rate Fractions on CalculatorInputs from
the same Table 12a helpers the SAP cost path uses, so Bill Derivation's
day/night split matches the rating's exactly.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A predicted EPC is seeded by deep-copying one representative neighbour's
structure. _template chose the member whose floor area was closest to the
cohort median, ignoring building-part labels. When that member's only part
was lodged with a null identifier (mapped to OTHER), the prediction had no
MAIN part and the modelling_e2e handler rejected it as "not predictable" —
discarding an otherwise-rich same-type cohort.
Restrict the template to MAIN-bearing members (median still over the whole
cohort); fall back to closest-on-size only when none are MAIN-bearing, so an
all-unlabelled cohort is left for the handler's MAIN-part guard to reject
rather than silently relabelling real data.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).
Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.
Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).
Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.
Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):
- Override overlay *completes* the partial system the landlord named. Companion
fields are now DERIVED from the SAP code, not hand-attached per archetype: the
off-peak meter from the calculator's single off-peak classification (new
OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
charge control defaults to the conservative manual control (Table 4e 2401). So
adding a heating archetype is just adding its code — companions can't be
forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
sap_heating cluster — the donor is already coherent.
Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.
Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>