Contains projects associated to the development of modeling products
Find a file
Khalim Conn-Kowlessar 1cb85c592f Slice S0380.144: Table 11 — per-Table-4a-code secondary fraction dispatch for electric storage heaters + remove code 408 from §A.2.2 forced-secondary set
SAP 10.2 Table 11 (PDF p.188) "Fraction of heat supplied by
secondary heating systems" — the "Electric storage heaters (not
integrated)" row splits by Table 4a sub-type:

  - not fan-assisted:                                       0.15
  - fan-assisted:                                           0.10
  - high heat retention (as defined in 9.2.8):              0.10

Plus separate rows:
  Integrated storage/direct-acting electric systems:        0.10
  Electric room heaters:                                    0.20
  Other electric systems (e.g. underfloor):                 0.10

Cross-referenced with SAP 10.2 Table 4a (PDF p.166) Electric
storage codes:

  401: Old (large volume) storage heaters     — not fan-assisted
  402: Slimline storage heaters                — not fan-assisted
  403: Convector storage heaters               — not fan-assisted
  404: Fan storage heaters                     — fan-assisted
  405: Slimline + Celect                       — not fan-assisted
  406: Convector + Celect                      — not fan-assisted
  407: Fan + Celect                            — fan-assisted
  408: Integrated storage + direct-acting      — "Integrated"
  409: High heat retention                     — HHR
  421: Underfloor heating                      — "Other electric"

Pre-slice the cascade defaulted `_secondary_fraction` to 0.10 for
every forced electric-storage code (Elmhurst mapper leaves
`main_heating_category=None`, dispatch falls through to the
`_SECONDARY_HEATING_FRACTION_DEFAULT` 0.10), missing the 0.15
not-fan-assisted sub-row on codes 401/402/403/405/406.

Two compounding spec-citable fixes:

(a) New `_SECONDARY_FRACTION_BY_ELECTRIC_STORAGE_CODE` dispatch dict
    consulted before the category-based lookup in
    `_secondary_fraction`. Routes each Table 4a 4xx code to its
    Table 11 sub-row fraction.

(b) Code 408 removed from `_FORCE_SECONDARY_FOR_MAIN_CODES`.
    SAP 10.2 §A.2.2 (PDF p.~189) verbatim: "This applies to main
    heating codes 401 to 407, 409 and 421" — 408 is explicitly
    NOT in the spec's forced list. The integrated storage+direct-
    acting heater's direct-acting element acts as the secondary
    already, so the calculation doesn't add another.

Corpus impact (electric variants — Elmhurst mapper path):

- electric 3 (SAP 401): sec_frac 0.10 → 0.15; CO2 -117.84 →
  -108.88; PE -1121.97 → -1093.18. SAP / cost residual unchanged
  because the off-peak meter routes the cost calc through the
  `_ZERO_FUEL_COST_FOR_OFF_PEAK` sentinel + legacy scalar-field
  math which bills main and secondary at the same off-peak low
  rate (7.41 p/kWh) — main-vs-secondary split is cost-neutral.
- electric 5 (SAP 402): sec_frac 0.10 → 0.15; CO2 -11.08 → -2.48;
  PE -161.03 → -133.36. Same cost-invariance.
- electric 7 (SAP 408): forced-secondary removed → cascade secondary
  fuel kWh 891 → 0 (matches worksheet); CO2 -37.86 → -53.57;
  PE -498.47 → -549.37. SAP residual unchanged (same off-peak
  cost-invariance).
- electric 4/6/8/9: no change (categories 404/409/421 keep their
  existing 0.10 dispatch).

The remaining +2.55 SAP residual on electric 3 (+1.29 on electric 7)
is now confirmed to be driven by space-heating DEMAND undercount
(cascade SH demand 10083 kWh vs worksheet 11088 kWh for electric 3;
8914 vs 9529 for electric 7), not by sec_frac dispatch. That's a
separate slice — likely §9 MIT calc or §8 gains/HLC for storage-
heater R values, follow-up after this slice.

Extended handover suite: 887 pass, 0 fail (was 886 + 1 new AAA test).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-01 16:28:48 +00:00
.devcontainer pr review, move domain and orhcestration 2026-06-01 14:00:31 +00:00
.github/workflows added landlord description overrides 2026-05-29 12:12:54 +00:00
.idea scaffolding for ml pipeline 2026-05-16 14:15:56 +00:00
.vscode added utils to allow easier subtask management 2026-03-02 15:15:39 +00:00
applications move landlord overrides 2026-06-01 15:46:46 +00:00
asset_list Remove EPC and asset_list changes unrelated to SAL handler 2026-05-22 15:36:46 +00:00
backend Slice S0380.144: Table 11 — per-Table-4a-code secondary fraction dispatch for electric storage heaters + remove code 408 from §A.2.2 forced-secondary set 2026-06-01 16:28:48 +00:00
backlog implemented onboarding 2026-04-21 20:23:33 +00:00
datatypes Slice S0380.143: RdSAP 10 §10.11 Table 29 — derive cylinder insulation defaults from construction age band when §15.1 lodges "No Access" 2026-06-01 16:28:48 +00:00
deployment/terraform added landlord description overrides 2026-05-29 12:12:54 +00:00
docs/adr move landlord overrides 2026-06-01 15:46:46 +00:00
domain Slice S0380.144: Table 11 — per-Table-4a-code secondary fraction dispatch for electric storage heaters + remove code 408 from §A.2.2 forced-secondary set 2026-06-01 16:28:48 +00:00
epr_data_exports allowing carbon and energy otimisation by removing slack 2025-07-31 19:13:16 +01:00
etl booking status 2026-06-01 16:28:47 +00:00
infrastructure GoogleSolarApiClient raises BuildingInsightsNotFoundError on 404 entity-not-found 🟩 2026-06-01 16:28:47 +00:00
model_data/requirements its working the way khalim wanted wiht postcode and then search that 2026-01-22 15:17:13 +00:00
orchestration moved classifier data transformation to an easy one 2026-06-01 14:53:34 +00:00
recommendations save 2026-05-07 15:55:44 +00:00
repositories move landlord overrides 2026-06-01 15:46:46 +00:00
scripts Slice S0380.39: bulk-fetch 38 cohort-2 EPC API JSONs for cross-mapper parity 2026-06-01 16:28:47 +00:00
sfr/principal_pitch added added historic epc data class with shape 2026-05-08 12:03:35 +00:00
survey_report quidos site notes extraction 2025-02-18 19:49:29 +00:00
tests GoogleSolarApi translates BuildingInsightsNotFoundError to sentinel dict 🟩 2026-06-01 16:28:47 +00:00
utilities get rid of comments 2026-05-20 13:21:11 +00:00
utils rename files in sharepoint to desired structure 2026-05-20 16:26:07 +00:00
.coveragerc fixed unit tests 2023-10-05 16:04:12 +01:00
.dockerignore deployment from infrastructure 2026-05-19 12:55:30 +00:00
.gitignore fixed merge conflicts from main 2026-05-26 11:21:09 +00:00
__init__.py added checking for directory before creation and made some minor style changes 2023-08-25 15:21:17 +01:00
ara_backend_design.md refactor: lift-and-shift packages/domain/src/domain/ml → domain/sap10_ml 2026-05-26 13:01:35 +00:00
BaseUtility.py fixed missing task and subtask for single remote assessments 2025-11-27 17:50:26 +00:00
CLAUDE.md fixed merge conflicts from main 2026-05-26 11:21:09 +00:00
conftest.py working on integrating new EPC api into address2UPRN 2026-04-27 11:32:44 +00:00
CONTEXT.md refactor: lift-and-shift packages/domain/src/domain/ml → domain/sap10_ml 2026-05-26 13:01:35 +00:00
devcontainer.sh add dev container 2026-04-17 14:50:57 +00:00
Dockerfile.test fix: address 22 project-wide test failures from previous sweep 2026-05-26 13:34:51 +00:00
Dockerfile.test.dockerignore deployment from infrastructure 2026-05-19 12:55:30 +00:00
Makefile adding to dev container to create shared network on start up 2026-04-25 15:03:07 +00:00
MEMORY.md memory 2026-04-02 10:24:31 +00:00
package-lock.json restructuring openUrpn code 2023-07-20 11:41:43 +01:00
package.json restructuring openUrpn code 2023-07-20 11:41:43 +01:00
pyproject.toml slice 14a: ml_training_data pkg + sample.py (CSV filter + random sample) 2026-05-16 17:39:43 +00:00
pyrightconfig.json slice 14d: build_features wires bulk reader -> mapper -> EpcMlTransform 2026-05-16 18:38:41 +00:00
pytest.ini refactor: lift-and-shift packages/domain/src/domain/ml → domain/sap10_ml 2026-05-26 13:01:35 +00:00
README.md adding to dev container to create shared network on start up 2026-04-25 15:03:07 +00:00
run_lambda_local.sh debugging local lambda run and updating the sap point checking condition 2023-09-13 18:47:12 +01:00
serverless.yml added logic to add to serverless 2026-04-22 12:39:44 +00:00
test.requirements.txt tests wrong environemnt 2026-05-29 16:17:06 +00:00
tox.ini removing playright install for integration test 2026-04-30 20:08:13 +00:00
UBIQUITOUS_LANGUAGE.md postcode_splitter: pure domain (UserAddress, sanitise_postcode, postcode_batching) 2026-05-19 16:45:47 +00:00

Model Repository

This repository contains the code pertaining to the development of the data science and machine learning products being utilised by Hestia.

The different folders in this repository relate to services that can be used independently, or can be imported and used as part of a larger application

Getting Started

Prerequisites

Dev Container Setup

This repo uses a Docker Compose-based dev container. The model-backend service joins a shared-dev Docker network so it can communicate with other local services (e.g. a frontend container) running on your machine.

VS Code users: The initializeCommand in devcontainer.json creates the shared-dev network automatically before the container starts. No manual step required — just open the repo and select Reopen in Container.

Non-VS Code / CI workflows: Run the following once before starting the container:

make dev-setup

This is idempotent and safe to re-run if the network already exists.

Folders

backend/

This folder contains the code for the fastapi backend service, which provides an interface to much of the functionality in this repository, for the frontend

model_data/

This folder contains related to the reading and preparation of assessment model data, including pulling out epc attributes

Testing

All tests can be run, against the configuration in pytest.ini running

pytest

This will run the complete panel of tests and report on coverage in the locations specified by the pytest.ini file.

To run tests in a specific service, e.g. inside of model_data, simply run

pytest --cov-config=model_data/.coveragerc --cov=model_data

This will produce the test results and coverage reports