# Follow-ups from the full-SAP baseline-downgrade work (ADR-0037)
|
||
|
||
Open items surfaced while fixing the full-SAP mapper / portfolio-796 downgrades.
|
||
Each is **separate from** the full-SAP fix (`fix/baseline-downgrades`).
|
||
|
||
## 1. RdSAP ventilation mapping is inconsistent across schemas
|
||
|
||
**Severity: accuracy bug for MEV/MVHR dwellings.** The mappers handle
|
||
`sap_ventilation` four different ways:
|
||
|
||
- `17_0` + full-SAP — build via `_sap_17_1_ventilation`, which **maps**
|
||
`mechanical_ventilation_kind`. ✅
|
||
- `21_0_1` — rich inline `SapVentilation(...)` incl. the kind. ✅
|
||
- **`17_1` / `18_0` / `20_0_0`** — built `SapVentilation(sheltered_sides=…)` and
|
||
**dropped** the kind. **Fixed in #1333** (mirror `_api_mechanical_ventilation_kind`).
|
||
- **`19_0` / `21_0_0`** — set **no `sap_ventilation` at all** → the
|
||
`EpcPropertyData` default (`None`). They dropped the **entire** ventilation
|
||
block (sheltered sides + kind), not just the kind. **Fixed in
|
||
`feat/rdsap-19-21-ventilation`**: both now construct `SapVentilation(...)`
|
||
mirroring 21.0.1, but only for the fields each schema lodges — the top-level
|
||
`mechanical_ventilation` enum (→ kind) and `sheltered_sides` (from
|
||
`built_form`). Neither lodges the fan/flue/vent counts, so those stay unset
|
||
(RdSAP Table-5 age defaults — see counts note below).
|
||
|
||
Either way, an MEV/MVHR cert (`mechanical_ventilation ≠ 0`) is treated as
|
||
**natural** by the affected mappers — wrong §2 ventilation cascade (and heat
|
||
recovery). Natural certs (code `0`/`5` → `None`) are unaffected.
|
||
|
||
- For **natural-ventilation** certs (`mechanical_ventilation = 0`, e.g. UPRN
|
||
100020603823 / property 726605) it's **benign** — unmapped → `None` defaults to
|
||
natural in the §2 cascade.
|
||
- For **MEV/MVHR** certs (`mechanical_ventilation ≠ 0`) the calculator treats the
|
||
dwelling as **naturally ventilated**, getting the SAP §2 ventilation cascade
|
||
(and any heat recovery) wrong → mis-scored SAP.
|
||
|
||
The granular **counts** (fans/flues/vents) are *not* a bug: older RdSAP open-data
|
||
certs don't lodge them, and the calc correctly uses RdSAP Table-5 age defaults.
|
||
`percent_draughtproofed` is mapped (top-level) and read by the calc.
|
||
|
||
**19.0 / 21.0.0 fix (done, `feat/rdsap-19-21-ventilation`):** both build
|
||
`SapVentilation(sheltered_sides=…, mechanical_ventilation_kind=…)` mirroring
|
||
21.0.1. Guarded by the extended mapper-level MVHR test + a `sheltered_sides`
|
||
regression, with the corpus (held 73.3% / MAE 0.774 — it's 21.0.1-only so the
|
||
change isn't exercised by it) and the 6002-case mapper-corpus staying green.
|
||
**Outstanding SAP-accuracy fast-follow:** an **Elmhurst-anchored MEV/MVHR
|
||
`RealCertExpectation`** (the corpus is natural-vent-dominated, so the kind
|
||
change isn't exercised by it). **Blast radius (still to quantify):** count
|
||
portfolio-796 certs on schema 19.0 / 21.0.0 with `mechanical_ventilation ≠ 0`.
|
||
|
||
## 2. FE "Main Fuel: Unknown" is FE-side, not a Model mapper gap
|
||
|
||
`main_fuel_type` (the gov fuel **code**) **is** populated Model-side — UPRN
|
||
10093412452 (709791) → `1`, UPRN 100020603823 (726605) → `26` — and is persisted
|
||
(`epc_main_heating_detail.main_fuel_type`). So the panel's "Main Fuel: Unknown"
|
||
is the **front-end** either not mapping the code → fuel name or reading a field we
|
||
don't populate. Needs an FE-repo (Drizzle/Next) check, not a Model change.
|
||
|
||
## 3. Survivor clusters from the post-fix population sweep
|
||
|
||
`scripts/hyde/case_a_population_sweep.py`: the representative sample rebaselined
|
||
cleanly (0 survivors), but the worst-old-drop sample held **28 survivors**
|
||
(lodged A/B → new C/D, 15–25 SAP) in tight UPRN clusters (new-build blocks),
|
||
spanning multiple schemas (16.0/16.1/17.1/18.0.0) and heating types. No single
|
||
mapper-gap signature → likely genuine SAP-2012→10.2 drops for very-high-lodged
|
||
new-builds, but **triage one in Elmhurst** to confirm genuine vs a residual calc
|
||
issue before trusting the cohort.
|
||
|
||
## 4. Predicted-property display path (e.g. property 721167)
|
||
|
||
721167 has **no lodged EPC** (predicted). Its Heating-Control / Main-Fuel /
|
||
Ventilation Unknowns come from the prediction synthesis path
|
||
(`domain/epc_prediction/epc_prediction.py`), **not** the lodged-cert mappers and
|
||
**not** the landlord-override overlay (`overlays_from` is simulation-time only,
|
||
ADR-0032 — it never writes the persisted/displayed EPC). Investigated and fixed
|
||
on `fix/predicted-property-display-unknowns`:
|
||
|
||
- **Heating Control — FIXED (Model).** `_apply_heating_donor` copied the donor's
|
||
*calc* `sap_heating` cluster but left the *display* rows (`main_heating`,
|
||
`main_heating_controls`) on the size-representative structural template —
|
||
incoherent with the donated system, and "Unknown" whenever the template lodged
|
||
no control row (exactly 721167: no `main_heating_controls` energy element
|
||
persisted). Now carries the donor's display heating + control alongside the
|
||
calc cluster.
|
||
- **Ventilation — FIXED (Model).** The prediction never synthesised ventilation
|
||
— it kept the template's `sap_ventilation`, so a predicted dwelling in an
|
||
MEV/MVHR neighbourhood was scored + displayed as natural. New
|
||
`_apply_ventilation_mode` modes `mechanical_ventilation_kind` across the cohort
|
||
(recency/geo-weighted, mirroring glazing). Natural-vent cohorts mode to None
|
||
and stay natural (§2 default) — so a genuinely natural dwelling like 721167
|
||
correctly stays natural; the fix moves only real MEV/MVHR neighbourhoods.
|
||
- **Main Fuel — NOT a prediction gap.** `epc_main_heating_detail.main_fuel_type`
|
||
*is* persisted for predicted properties (721167 → `26` = mains gas, carried
|
||
from the heating donor). The "Unknown" is the **same FE code→name gap as item
|
||
2** (the Drizzle/Next repo not mapping the fuel code), not a Model issue.
|
||
|
||
Both fixes are display-only for the calculator (component-accuracy gate, corpus
|
||
harness, and prediction e2e all green); persistence already carries
|
||
`main_heating_controls` (energy element) and `ventilation_mechanical_ventilation_kind`,
|
||
so the synthesised values reach the passport on the next prediction run.
|