Model/datatypes/epc
Khalim Conn-Kowlessar 58088c1056 Slice 53: Summary_000487 chain pins SAP at 1e-4 — last cohort cert closed
Three extensions closing the last 0.05 SAP residual on 000487 — and
with it, all 6 Elmhurst Summary PDFs match their U985 worksheets to
1e-4 unrounded SAP.

1. Alternative-wall extraction. `WallDetails` gains an
   `alternative_walls: List[AlternativeWall]` field; the extractor
   parses §7's "Alternative Wall N Area / Type / Insulation /
   Thickness / Thickness Unknown / U-value Known" prefixed labels.
   Even when an extension lodges "As Main Wall: Yes" we still pull
   alt walls from the extension's own subsection (they don't
   inherit) — the main wall fields are merged with the extension's
   alt-wall list.

2. Alt-wall mapper plumbing. `_map_elmhurst_alternative_wall` builds
   a `SapAlternativeWall` per lodged Elmhurst entry; the building-
   part mapper attaches up to two via `sap_alternative_wall_1/_2`
   per `SapBuildingPart`. When the surveyor flags `Thickness
   Unknown: Yes` (cohort's only example — 000487 Ext1's
   "TimberWallOneLayer" entry) we route the cascade with
   thickness=None so `u_wall` falls through to the age-band-and-
   construction default — Timber Frame age B uninsulated → U=1.9,
   matching the full-cert-text U=1.90 the handbuilt fixture lodges
   for the same 9-mm thin timber wall.

3. "TI" wall-construction code mapping. The §7 "Alternative Wall 1
   Type: TI Timber Frame" uses leading code "TI" rather than the
   "TF" code seen on the primary wall types — both alias to SAP10
   wall_construction=5 (Timber Frame).

Final cohort state — all 6 closed at 1e-4:

  000474   0.0000  ✓ Slice 47
  000477   0.0000  ✓ Slice 52
  000480   0.0000  ✓ Slice 50
  000487   0.0000  ✓ THIS SLICE
  000490   0.0000  ✓ Slice 49
  000516   0.0000  ✓ Slice 51

758 tests pass; pyright net-zero (35 baseline).

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-05-24 21:42:42 +00:00
..
domain Slice 53: Summary_000487 chain pins SAP at 1e-4 — last cohort cert closed 2026-05-24 21:42:42 +00:00
loaders demo generated for use in address2uprn 2026-05-08 14:48:15 +00:00
schema Slice 44: flat_roof_insulation_thickness mapper fix — surface lodged value on SapBuildingPart 2026-05-24 15:28:10 +00:00
search bolstering testing 2026-04-28 13:46:09 +00:00
surveys Slice 53: Summary_000487 chain pins SAP at 1e-4 — last cohort cert closed 2026-05-24 21:42:42 +00:00
__init__.py testing out rebaselining 2026-02-12 22:25:03 +00:00
construction_age_band.py testing out rebaselining 2026-02-12 22:25:03 +00:00
efficiency.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
floor.py preparing partiy class 2026-02-05 08:54:27 +00:00
fuel.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
heating_controls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
hotwater.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
main_heating.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
property_type_built_form.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
roof.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
walls.py beginning to assembly the parity class 2026-02-04 18:34:59 +00:00
windows.py testing out rebaselining 2026-02-12 22:25:03 +00:00