Khalim Conn-Kowlessar 72ef0f0e7b fix(water): don't apply heat-pump water SCOP to a separate immersion (SAP N3.7a)
When a heat-pump cert lodges a PCDB Table 362 record, the APM override
set BOTH the space efficiency (N3.6) and the water efficiency (N3.7a)
from the heat pump unconditionally. But the PCDB η_water applies only
when the DHW is heated BY the heat pump (water-heating code "from main":
901/902/914). A separate electric immersion (WHC 903) heats the water at
100% regardless of the space system, so applying the HP's water SCOP
(187.5% × 0.6 in-use = 112.5%) under-counted the immersion's hot-water
fuel.

Gate the η_water override on the DHW-from-main codes; a separate immersion
keeps its own 100% efficiency. Space η_space still always uses the APM
value (the heat pump is the space main).

Worksheet-validated to 1e-4 on simulated case 45 (HP space + WHC-903
immersion): water fuel (62) 1893.57 -> 2130.2639, total cost (255)
619.7433, CO2 692.13 — all matching the P960 exactly; SAP 60.53 -> rounds
to the worksheet's 61. RdSAP-21.0.1 corpus unchanged (no HP+WHC903 certs
in it). Pinned in test_cert_to_inputs (immersion fuel is main-independent).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-18 13:44:51 +00:00
..
fixtures/golden fix(ventilation): map API mechanical_ventilation_index_number for MEV fan electricity 2026-06-08 23:16:34 +00:00
__init__.py Move sap10_calculator tests to tests/domain/sap10_calculator/ for CI 2026-06-02 16:58:00 +00:00
test_cert_to_inputs.py fix(water): don't apply heat-pump water SCOP to a separate immersion (SAP N3.7a) 2026-06-18 13:44:51 +00:00
test_golden_fixtures.py fix(water-heating): count electric showers in Noutlets for mixer demand (App J) 2026-06-13 23:31:02 +00:00