The Domna product for domestic retrofit modelling: ingests open-source EPC data, lets users correct or supersede it with their own surveys, and produces optimised retrofit packages for each property in a portfolio.

Language

Product

Ara: The Domna product. Latin for "the altar"; named under Domna's classical-naming convention. Covers both the modelling product and the backend that powers it. Avoid: ARA (acronym style), v2 backend, the new backend

Domna: The company. Roman name; sibling to Ara in the same naming convention.

Energy Performance Certificates

EPC: An Energy Performance Certificate — a government-issued document rating a dwelling's energy efficiency from A (best) to G (worst). Avoid: energy certificate, energy report

Certificate Number: The unique identifier assigned to an EPC by the government registry. Avoid: cert number, EPC ID

Registration Date: The date an EPC was lodged with the government register; used to identify the most recent certificate for a property. Avoid: assessment date, submission date

EPC Band: A single letter AG representing a property's current or potential energy efficiency rating. Avoid: energy rating, EPC grade, EPC score

Schema Type: The versioned RdSAP or SAP schema that describes the structure of an EPC's raw data (e.g. RdSAP-Schema-21.0.1). Avoid: schema version, EPC format

Full-SAP Assessment: A cert produced by a full SAP calculation rather than the reduced RdSAP procedure — lodged with assessment_type = "SAP" and a measured-openings structure (sap_opening_types, per-opening U-values), typically on an older spec (SAP-Schema-16.x/17.x, sap_version ~9.9x = SAP 2012). Structurally distinct from an RdSAP Assessment (reduced categorical fabric, no measured openings), so it has its own mapper (from_sap_schema_17_1), routed to by structure not label (a structurally full-SAP cert is mapped here regardless of a mislabelled schema_type). Because full-SAP certs lodge pre-10.2 figures they are rebaselined to SAP 10.2 like any pre-SAP10 cert (Rebaselining trigger (a)); a mapper that drops their sap_version silently suppresses that rebaseline and leaves Effective Performance stuck on the lodged value (ADR-0037). Avoid: SAP cert (ambiguous — every EPC is a SAP-derived cert), on-construction EPC (overlaps but not synonymous)

Domestic Certificate: An EPC issued for a residential dwelling, as opposed to a commercial one. Avoid: residential EPC, home EPC

Non-Separated Conservatory: A conservatory joined to the dwelling without an external-quality thermal separation (open archway or only an internal-quality door). RdSAP treats it as part of the dwelling (§6.1): the assessor measures its glazed perimeter, floor area, glazing type and storey height, and its floor area, glazed walls (as a window), glazed roof (as a rooflight) and ground-loss all fold into the dwelling's score. On the gov register this is conservatory_type = 4, lodged as a glazed "building part" carrying only those four measurements — never fabric or floor dimensions. It is the only conservatory kind that affects the score, so it must be carried as a distinct part of the dwelling picture, not treated as a generic fabric building part (which mis-scores it and lacks the construction fields the register requires). Avoid: "floor-only building part" / "degenerate part" (it is a fully-measured glazed conservatory — it only looks empty when a schema drops its four fields); "heated conservatory" (heating is the question asked of a Separated Conservatory, not this one)

Separated Conservatory: A conservatory partitioned from the dwelling by an external-quality door (substantial, draught-sealed). RdSAP disregards it entirely (§6.2) — no measurements are taken and it contributes nothing to the score; the register records only whether it has fixed heaters (conservatory_type = 2 unheated / 3 heated) and lodges no glazed building part. conservatory_type = 1 means no conservatory at all. Avoid: conflating with a Non-Separated Conservatory (the separated one is scored as if absent); "thermally separated" as a synonym for "heated" (separation is about the door, heating is a further question asked only once separated)

Properties and addresses

Property: The Ara domain aggregate representing a single dwelling under modelling: its identity, source data, enrichments, and modelling outputs. Avoid: dwelling, unit, home, asset

Properties: A first-class collection of Property objects; the unit of bulk operation in services. Avoid: property list, batch (used for SQS chunks)

UPRN: Unique Property Reference Number — the government-issued permanent identifier for a physical address in the UK. Avoid: property ID, address ID, code

Postcode: A UK postal code used to group nearby addresses; the primary search key for finding EPC records. Avoid: zip code, postal code

User Address: A structured dataclass (domain.addresses.user_address.UserAddress) capturing a customer-supplied address: a free-text user_address line, a canonical postcode (sanitised on construction), and an optional internal_reference. The bare string sense — the raw free-text address line as it arrives from upstream ingestion, before being wrapped — remains valid when discussing CSV columns, API payloads, or other upstream contexts; in domain code, prefer the dataclass. Avoid: user input, raw address, user_inputed_address

Comparable Properties: The reference cohort matched to a target Property, used by EPC Prediction for gap-filling and anomaly detection. Selected by a filter-then-relax ladder: hard filters on identity (property type, built form) and any known Landlord Override (e.g. a known solid-brick wall) while at least k remain, widening the geographic scope (postcode → postcode-prefix) or demoting a known field to a weight when sparse. Survivors are weighted for prediction by geographic proximity × recency × physical similarity — closer, newer (newer EPCs are higher quality), more-similar comparables count more. All cert vintages are kept as source evidence — a building's physical components (wall / roof / floor / heating fuel / age) are agnostic of the SAP methodology that rated them, so a pre-SAP10 neighbour is valid evidence; recency is a graduated weight, never a hard drop, and matters most for the one component that genuinely goes stale (the heating system, when a boiler is replaced). Only the validation target is restricted to SAP 10.2 — see validation-cohort / sap-spec-version — because performance can only be checked against a same-spec lodged figure. Avoid: neighbours, similar properties, peer set

EPC Prediction: Producing a Property's EpcPropertyData picture from its Comparable Properties when it has no EPC (~30% of UK homes, typically long-tenure). Deterministic neighbour synthesis (k-NN-style — not ML; no trained model): take the cohort mode for the homogeneous categoricals (wall / roof / floor construction + insulation, construction age band), copy a single representative comparable's structure wholesale (building parts, per-window dimensions + orientations, floor dimensions) so the picture stays internally consistent for the calculator, then apply Landlord Overrides and the known inputs on top. The result is scored through SAP10 Calculation like any other Effective EPC, so a predicted Property flows through Rebaselining, Bill Derivation, and Modelling unchanged — held in a distinct predicted-EPC slot that coexists with any lodged EPC (so provenance is structural and the UI can flag it; see ADR-0031). A known property type is required — the hard cohort filter (a flat is never sized from houses) — supplied by a Landlord Override (or, later, an Ordnance Survey lookup); a Property whose property type is genuinely unknown is gated out, never predicted from a mixed-type cohort and never given a national default. The same cohort machinery also produces EPC Anomaly Flags for Properties that do have an EPC. A future learned-weighting refinement is possible but separate, as with the calculator's ML residual head. Avoid: EpcPredictionService (no "service" suffix — name the operation), ML prediction (it is deterministic), EPC estimation

Survey documents

Ventilation Audit: A machine-generated .xlsx spreadsheet produced by the audit-generator Lambda from a property's parsed MagicPlan Plan. Written fields per room: room name, width, length, area. Per window: dimensions, opening type, number of openings, percent openable (pct_openable), trickle vent count and area per vent. Per door: width and undercut. Internal doors appear once per room they connect (so typically twice). Columns requiring human knowledge (Blocked, Pictured, FP reference numbers, door location labels) are left blank for the coordinator to complete. Recorded in uploaded_files with file_type = VENTILATION_AUDIT and file_source = AUDIT_GENERATOR. Distinct from a PAS 2023 Ventilation document, which is externally uploaded by a human. Avoid: ventilation report, audit report, PAS ventilation (that is the external survey form)

PAS 2023 Ventilation: An externally-uploaded ventilation survey document produced by a human assessor and ingested from an external source (e.g. Coordination Hub). Recorded in uploaded_files with file_type = PAS_2023_VENTILATION. Distinct from a Ventilation Audit, which is machine-generated from MagicPlan floor plan data. Avoid: ventilation audit (that is the generated output)

Source data

Site Notes: The full-coverage record produced by a Domna survey of a single Property; carries every EPC field the modelling pipeline requires, and when present supersedes the public EPC for that Property — except when the public EPC is newer. Avoid: energy assessment, site survey, field survey, Domna survey, Hestia survey

Landlord Overrides: Property data supplied by a landlord that may correct or supplement the public EPC for a single Property; triggers Rebaselining when applied; not applicable when Site Notes are present. Avoid: patches (deprecated), corrections, manual EPC, edits

Landlord-Description Classification: Resolving a Landlord Description (unbounded free-text a landlord supplies for one component — "CWI" / "Cav filled" / "cavity insulated" all name one thing) onto a Recognised Internal Description via an LLM classifier, persisted in the landlord_*_overrides table (source=classifier) as a reviewed cache. Four vocabularies are kept distinct and must not be conflated: a Landlord Description (unbounded input); a Recognised Internal Description (the closed target taxonomy — e.g. a MainHeatingSystemType archetype — each binding to a Simulation Overlay); a Lodged Description (the gov-EPC main_heating[].description rendering, e.g. "Room heaters, electric" — only an example of which system types occur, never a map key); and the SAP main heating code (Table 4a/4b, what the calculator consumes). The classifier maps Landlord → Recognised Internal → SAP code. When it cannot confidently place the text it emits None (no overlay → the lodged EPC stands, surfaced to the user as "no suitable match"), never the nearest wrong archetype — the target taxonomy must be complete enough that a real system always has a correct home, so the classifier never overflows into a garbage-drawer archetype (ADR-0041). Avoid: "the LLM mapper is unreliable" (the failure mode is a too-small target taxonomy, not LLM language ability); conflating the landlord input vocabulary with the gov-EPC lodged rendering or the RdSAP entry-tool catalogue; treating a deterministic dict as a replacement for the LLM rather than a reviewed cache of its output

Modelling

Effective EPC: The assembled EpcPropertyData picture the modelling pipeline scores for a single Property. Assembled from whichever source applies: Site Notes alone; or the public EPC with Landlord Overrides applied; or — when the EPC is old — its schema re-mapped to current via Reduced-Field Synthesis (deterministic, from the cert plus calibrated coefficients — no neighbour data); or — when there is no EPC — components estimated from surrounding properties via EPC Prediction (deterministic neighbour synthesis). Carries source-derived physical fields and originally recorded performance values; the performance scored from this picture is held separately in Baseline Performance. Avoid: modelling EPC, working EPC, resolved EPC, derived EPC

Rebaselining: Establishing a Property's Effective Performance (SAP score, EPC Band, CO2, Primary Energy Intensity, space-heating & hot-water kWh) by assembling the Effective EPC picture and scoring it through SAP10 Calculation (the deterministic Sap10Calculator, which superseded the old ML-API rebaseliner; an ML residual head over the calculator is future — ADR-0009/0013). The assembly is the substance: apply Landlord Overrides (e.g. boiler → ASHP, wall insulated) as a simulation on the EpcPropertyData; re-map an old-schema EPC to current via Reduced-Field Synthesis (deterministic, cert-only); estimate components from surrounding properties when there is no EPC (EPC Prediction — deterministic neighbour gap-fill). The calculator is the scoring engine at the tail, not the whole of Rebaselining — so its call lives inside the Rebaseliner, after assembly. Triggered whenever the assembled picture differs from the lodged record: (a) the EPC was lodged under a methodology the calculator supersedes (sap_version < 10.2), (b) Overrides / Site Notes changed the physical state (walls / heating / windows / etc.), or (c) the picture is estimated or remapped rather than a real current EPC. Produces Effective Performance; Lodged Performance is preserved unchanged. The same single scoring also yields the per-end-use kWh that Bill Derivation prices — one scoring, two products. kWh is an ML target per ADR-0007 — see epc-ml-transform. Avoid: re-scoring, re-prediction, performance recomputation, refresh (for cache-freshness)

Reduced-Field Synthesis: Deterministically translating an old / reduced-data EPC schema into the current EpcPropertyData, synthesising the measured fields the target expects from the source's reduced or categorical fields, using only the cert itself plus fixed calibrated coefficients — never neighbour data. Used when re-mapping a pre-SAP10 cert (e.g. RdSAP-Schema-20.0.0) as part of assembling the Effective EPC: e.g. a glazing-area band + floor area → window m²; bath/shower room counts → bath and shower counts. A best attempt with no ground truth to validate against (per the Validation Cohort rule, a pre-SAP10 cert has no same-spec lodged figure to check), so each synthesis assumption is recorded explicitly in code and tests to keep it debuggable. Distinct from EPC Prediction (deterministic neighbour estimation of genuinely-absent fields from surrounding properties — the no-EPC path) and from the calculator's own RdSAP Table-5 defaulting in cert_to_inputs (which expands EpcPropertyData into the full SAP input set downstream). Avoid: gap-fill (means the neighbour-ML path), reduced-data expansion (overloaded with the calculator's Table-5 step), remapping (the schema-translation part only)

Baseline Performance: A Property's current performance aggregate, holding both Lodged Performance and Effective Performance plus the energy block: delivered kWh per end use (heating, hot water, lighting, appliances, cooking, pumps/fans, cooling) and the annual bill composed into per-section costs plus a total, produced by Bill Derivation from SAP10 Calculation's per-end-use kWh × current Fuel Rates. Persisted as one row (flat typed columns, per-section kWh + cost + total); surfaced as one block in the UI. The Lodged half is optional: a predicted Property has no lodged record (see Lodged Performance), so its lodged_* are NULL and only the Effective half + energy block are populated (ADR-0004 amendment, #1361). Avoid: baseline predictions, predicted baseline, rebaselined values

Lodged Performance: The SAP / EPC Band / carbon emissions / Primary Energy Intensity recorded on the public EPC (or the Site Notes' as-surveyed values when Site Notes are the source) — unmodified by modelling. The half of Baseline Performance that says "what the government register says about this Property". Requires a record of this Property — a lodged cert or a Site Notes survey — so it is absent (None/NULL) for a predicted Property: EPC Prediction synthesises the picture from neighbours, copying a comparable's recorded figures, so there is no government-register record of this Property to lodge. Only the Effective half is persisted then (ADR-0004 amendment, #1361). Reading a predicted EPC's recorded fields as Lodged Performance manufactures a phantom — a neighbour's SAP presented as this Property's lodged figure. Avoid: original performance, raw EPC values, recorded baseline

Effective Performance: The SAP / EPC Band / carbon emissions / Primary Energy Intensity the modelling pipeline actually scored against — equal to Lodged Performance when no Rebaselining trigger fires, replaced by SAP10 Calculation output (the deterministic Sap10Calculator, which superseded the old ML-API rebaseliner; an ML residual head over the calculator is future — ADR-0009/0013) when triggered. The half of Baseline Performance that says "what we modelled". Avoid: modelled performance, rebaselined performance (only correct when rebaselining ran), scored values

Calculated SAP10 Performance: The SAP score, EPC Band, CO2 emissions, Primary Energy Intensity, space heating kWh, and hot water kWh produced by SAP10 Calculation from a Property's EpcPropertyData. It is not a separately-persisted third value-set beside Lodged and Effective: in every baselining scenario the calculator's output is the Effective Performance (real lodged SAP10 EPC with no overrides ⇒ Calculated = Lodged = Effective; overrides or an estimated / pre-SAP10 EPC ⇒ Calculated = Effective, there being no lodged SAP10 figure to compare against). The calculator is therefore the mechanism that produces Effective Performance, having superseded the old ML-API rebaseliner. The calculator is load-bearing: for sap_version < 10.2 (lodged under a superseded methodology) its output is the Effective Performance; for ≥ 10.2 the API's lodged figures are kept only when the picture is a pristine lodged cert — when Landlord Overrides or EPC Prediction changed the physical state (Rebaselining trigger (b)/(c)), the calculator's output is the Effective Performance even at ≥ 10.2 (ADR-0039), because the accredited lodged figure no longer describes the dwelling. Divergence (SAP > 0.5, PEUI/CO2 beyond tolerance) is logged only in that pristine-lodged case — the one case where lodged-vs-calc is a meaningful validation signal (see sap-spec-version); when the calculator's output is adopted there is nothing to validate against. It is load-bearing for Bill Derivation regardless of version (the EPC lodges no per-end-use kWh), so a calculator strict-raise aborts the batch and the un-mapped cert is fixed immediately. ADR-0009 introduced the term, amended by ADR-0010, realized by ADR-0013 (whose shadow stepping-stone is superseded) and ADR-0014. Avoid: calculator output, computed performance, worksheet performance, SAP10 output, calculated value-set (it is not a stored third set)

SAP10 Calculation: The process that runs the deterministic SAP 10.2 (14-03-2025 amendment) worksheet over a Property's EpcPropertyData and emits Calculated SAP10 Performance. Implemented by the Sap10Calculator service class in domain/sap10_calculator/ (calculator.py). Reads cert fabric/heating/geometry fields, applies the RdSAP 10 (10-06-2025) cert→input mapping, executes the 12-month heat balance per SAP 10.2 §§1-14, looks up boiler/heat-pump performance in the PCDB when the cert lodges a product index, and returns a SapResult carrying the five Calculated SAP10 Performance quantities plus a monthly breakdown and worksheet-line audit trail. Distinct from Rebaselining, which is ML-based. ADR-0009 originally targeted SAP 10.3 (13-01-2026); ADR-0010 retargets to SAP 10.2 (14-03-2025) until the cert corpus migrates. Avoid: SAP calculation (ambiguous with the gov calculator), SAP scoring, calculator run, SAP 10.3 calculation (active target is 10.2 — see sap-spec-version)

SAP Spec Version: The dated revision of the SAP specification that produced a given SAP/PEUI/CO2 value. Domain-meaningful because the same EpcPropertyData yields different sap_score under different spec versions — fuel-price tables, CO2 factors, PCDB references, and rating-equation deflators all change between revisions. Lodged Performance carries the version current when the cert was lodged (mostly SAP 10.1 / SAP 10.2 pre- and post-14-03-2025 amendment in the corpus). Calculated SAP10 Performance is locked to SAP 10.2 (14-03-2025). A 1-to-1 Lodged-vs-Calculated comparison therefore only makes sense within a Validation Cohort of certs lodged on the same spec version. Avoid: SAP version (ambiguous with the sap_version field on the cert, which only carries the major version like 10.2 — not the amendment date), spec revision

Validation Cohort: The subset of corpus certs used to validate SAP10 Calculation against Lodged Performance, filtered to certs lodged after the calculator's target SAP Spec Version rolled out in commercial assessor software — currently inspection_date ≥ 2025-07-01 (a buffer past 14-03-2025 to allow vendor rollout). Smaller than the full corpus but each cert is comparable under the same spec, so probe MAE is a clean signal of calculator-vs-spec correctness rather than spec-version mixture noise. ADR-0010.

Component Accuracy: The primary, calculator-independent measure of EPC Prediction quality: how closely the predicted EpcPropertyData components (heating fuel + category + controls, hot water, wall / roof / floor construction + insulation, age band, glazing, doors, floor area + geometry) match the actual ones, scored by leave-one-out over a held-out target. Categoricals score as a classification hit-rate, numerics as a residual. Load-bearing principle: predict the components well and correct SAP / carbon / PE fall out once calculator gaps close — so Component Accuracy is what prediction is tuned against, while calc(predicted) vs API-lodged SAP / carbon / PE is a secondary, calculator-floored end-to-end check. The held-out target must be a SAP 10.2 cert (sap_version == 10.2) — the only vintage with full-fidelity lodged components — but the source Comparable Properties cohort keeps all vintages. Never validated by calc(predicted) vs calc(actual): that cancels (and so hides) calculator error against a circular ground truth. Avoid: prediction accuracy (vague), SAP accuracy (that is the calculator-floored end-to-end check, not the primary signal) Avoid: parity cohort, validation set, corpus sample

Measure Application: The process that translates an Optimised Package into cert-field changes and produces the "ending state snapshot" EpcPropertyData that the Plan persists. Implemented by the MeasureApplicator service class in domain/sap/ (or a sibling package). Each Measure Type's translation rules (e.g. loft_insulationroof_insulation_thickness_mm = 270mm, ashpmain_heating_details[0] replacement) live here. Pure function — does not run SAP10 Calculation itself; the caller chains MeasureApplicator.apply(epc, package) → Sap10Calculator.calculate(post_epc). ADR-0009. Avoid: measure overrides (rejected during ADR-0009 grill — phantom mid-layer), package applier, retrofit simulator

Bill Derivation: The deterministic process that derives a Property's annual energy bill, composed into per-end-use sections (heating, hot water, lighting, appliances, cooking, pumps/fans, …) plus a total, by pricing SAP10 Calculation's delivered kWh per end use at current Fuel Rates — each end use billed at its fuel's rate, rolled up per fuel for standing charges (metered fuels only — gas/electricity; oil/LPG/solid have none) minus SEG export credit on PV. Implemented by BillDerivation in domain/billing/ (a cross-stage concern — the Baseline stage derives the current bill, the Modelling stage re-runs it on the post-package end-state for post-retrofit bills; deterministic, ADR-0006). Reads Fuel Rates from a committed static snapshot via FuelRatesRepository (no live ETL yet). Distinct from the calculator's total_fuel_cost_gbp, which is the SAP-rating notional cost at RdSAP Table 32 standardised prices (~half the real electricity price) — not what the household pays. Electricity on an Off-Peak Meter is billed day/night, each end use split by its own High-Rate Fraction. Raises on a fuel it has no rate for (e.g. house coal, heat network). ADR-0014. Avoid: EPC Energy Derivation (renamed), EpcEnergyDerivationService (no "service" suffix), kWh prediction, baseline kWh, energy estimation

Off-Peak Meter: A dwelling's dual-rate electricity meter (Economy-7-style) charging a cheaper night rate and a dearer day rate. It is a property of the meter, not of any one end use: every electric end use — heating, hot water, lighting, appliances, cooking — is billed on it, each split day/night by its own High-Rate Fraction. Derived from the RdSAP meter_type (or, in synthesis, from the heating SAP code per the heating-system cluster). The calculator already prices the whole meter this way; Bill Derivation mirrors it. Pricing an off-peak dwelling's electricity at the single standard rate is wrong in both directions — it over-bills night-shifted storage heat and under-bills daytime appliances. Avoid: Economy 7 (the common brand, but the model is tariff-agnostic — 7/10/18/24-hour all map here), off-peak fuel (it is a meter arrangement, not a distinct fuel carrier)

High-Rate Fraction: The fraction of one electric end use's annual kWh billed at the day (high) rate on an Off-Peak Meter; the remainder bills at the night (low) rate. A calculator output per end use (SAP 10.2 Table 12a — storage heating ≈ 0 / all-night, lighting & appliances ≈ 0.80.9 / mostly-day), reused by Bill Derivation rather than re-derived, so the bill's day/night split never diverges from the rating's. Unregulated loads SAP does not rate (appliances, cooking) inherit the Table-12a ALL_OTHER_USES fraction. Avoid: day/night ratio, peak fraction, split factor

UCL Correction: The per-band linear correction (Few et al. 2023, Energy & Buildings 288 113024) that aligns EPC-modelled Primary Energy Intensity with metered consumption. Folded into ML training labels at fit time (per ADR-0007) rather than applied at runtime — the trained model emits metered-equivalent PEUI directly, avoiding the discontinuities at EPC band boundaries that arose when the per-band linear correction was applied post-prediction. Calibrated against gas-heated, non-PV homes in England and Wales rated under SAP 2012; the current implementation extrapolates it to all properties (open question §15.14). Avoid: UCL adjustment, energy correction, metered correction

EPC Anomaly Flag: A per-field indicator that a Property's value for an EPC field differs significantly from Comparable Properties; advisory only — surfaces in the UI to prompt user review, does not block modelling. Avoid: outlier, mismatch, divergence flag

Pipeline composition

The modelling backend is composed from three independently-invocable stage orchestrators, chained differently per use case. This composability — not a single end-to-end function — is the point: it is what lets the interactive single-property flow pause between stages where the batch flows do not. (Supersedes the monolithic model_engine.)

Ingestion: The first stage. Acquires a Property's external source data — the EPC certificate (New EPC API) and Google Solar insights — and resolves its coordinates, then writes everything to repos. Writes only; runs no modelling business logic. Per ADR-0003 nothing downstream reads across this seam by calling back to a source — downstream stages read the persisted data from repos. Avoid: fetching (a fetch is one source call; Ingestion is the whole write stage), data load

Baseline (stage): The second stage. Reads the persisted source data from repos, hydrates the Property aggregate, resolves its Effective EPC, and establishes its Baseline Performance. Re-scoring after a user override lives here. Distinct from Baseline Performance (the aggregate it produces). Avoid: rebaseline (that is a specific ML trigger — see Rebaselining), enrichment

Modelling (stage): The third stage. Takes the baselined Property plus a set of Scenarios and produces Recommendations → an Optimised PackagePlans, persisted to repos. A separate orchestrator from Baseline so the single-property flow can stop after Baseline and only run Modelling when the user hits "play". Avoid: scoring (overloaded), recommendation engine

First Run: The use case where a Property has only a row in the property table (post address→UPRN matching) and no existing Plan: the pipeline runs Ingestion → Baseline → Modelling end-to-end over a batch. The first sibling lambda being built (ara_first_run). Avoid: initial run, cold run

ML training

EPC ML Transform: The versioned class at domain/sap10_ml/transform.py that maps an EpcPropertyData to a fixed-width row of features + targets. The single ML-data contract between this repo and the AutoGluon training repo. Owns the windows compression, building-parts compression, Top-N Code Taxonomy, and UCL folding decisions. Each version is tagged on the deployed scoring lambda; a mismatch is a deploy-time fail. Avoid: feature builder, ML mapper, EPC vectoriser

Feature Schema Version: The semver version of the EPC ML Transform (e.g. 0.1.0), included in the parquet output path and the deployed scoring lambda's tag. MAJOR bump when columns are removed or renamed; MINOR when optional columns are added; PATCH for non-behavioural fixes. Avoid: transform version, schema version (overloaded with the SAP RdSAP schema version on EPCs), model version

Primary Energy Intensity (PEUI): A Property's total annual primary energy use per square metre of floor area (kWh/m²/yr), the SAP10 quantity recorded as energy_consumption_current on the EPC. Covers all end uses (heating, hot water, lighting, appliances, cooking) weighted by SAP primary energy factors per fuel. The quantity the UCL Correction aligns to metered consumption. Avoid: heat demand (which colloquially means the building's space heating thermal requirement — a distinct concept), energy demand, total energy use, kWh per square metre

PV Capacity Source: A flag on the EPC ML Transform feature set indicating whether a Property's PV capacity is measured (from sap_energy_source.photovoltaic_supply[].peak_power), estimated_from_roof_area (the percent_roof_area fallback used when the surveyor could not confirm array configuration), or none (no PV present). Lets the model weight the correct capacity signal per property. Avoid: PV source, PV configuration type, solar source

Top-N Code Taxonomy: The empirical top-N SAP code list (covering ~95% of mass on the training sample) committed by the EPC ML Transform for each list-aggregated categorical field (wall_construction, glazing_type, frame_material, etc.). Rare codes go into a per-field _other bucket. The taxonomy is locked at each Feature Schema Version; changes warrant a MINOR bump (adding) or MAJOR bump (removing codes). Avoid: code list, code dictionary, vocab

Reference data

Fuel Rates: The current per-fuel rate (pence/kWh) and standing charge used to compute a Property's bills; time-versioned and regional. Sourced for now from a committed static snapshot (national, Ofgem-cap period for gas/electricity + DESNZ/NEP for off-gas fuels), read via FuelRatesRepository; an Ofgem-cap ETL automating the refresh is future, not a prerequisite. The Smart Export Guarantee rate sits in the same set as electricity_export. Consumed by Bill Derivation. Avoid: fuel prices (commodity prices, different concept), tariff, energy cost

Carbon Factors: The per-fuel CO2 emission factor (kgCO2e/kWh) used to compute a Property's carbon emissions; time-versioned, refreshed from Defra's annual publication. Consumed by Bill Derivation. Avoid: emission factors (ambiguous), CO2 rates

Outputs

Scenario: A named portfolio-level retrofit plan, built by a user in the scenario-builder UI and persisted before any modelling fires; carries the overall goal (e.g. Increasing EPC), budget, exclusions, housing type, and the set of measure types it permits. The model is triggered against one or more Scenarios at once; each Scenario yields one Plan per Property. Avoid: project, batch, run-set

Scenario Snapshot: A frozen copy of a Scenario pinned at trigger time, keyed by (task, scenario); used by the modelling pipeline so mid-run edits to the live Scenario do not affect an in-flight job. Snapshots are read-only and may be garbage-collected after the task completes. Avoid: scenario version, frozen scenario, pinned scenario

Plan: The per-Property output of one Scenario's modelling run; carries the Optimised Package selected for the Property (its Plan Measures) and the Property's post-retrofit figures (SAP / kWh / CO₂ / bills). A Property modelled against N Scenarios in one trigger ends up with N Plans. Avoid: recommendation set, output, result

Plan Measure: One selected Measure Option as persisted inside a Plan — the single Option the Optimiser kept for a given Recommendation, recorded with its installed Cost and its final-package (role-3) attributed impact (the SAP points and CO₂ / energy savings that telescope exactly to the Plan's package total, per ADR-0016). It is the output counterpart to a Recommendation's candidate Option: a Recommendation proposes mutually-exclusive Options carrying no stored impact, whereas a Plan Measure is the one that was chosen with its truthful attributed impact frozen in. The persisted set of a Plan's Plan Measures is its Optimised Package. Avoid: recommendation (that is the candidate — never persist an output as a Recommendation), installed measure, selected measure (that names the package, not the line), plan item, plan recommendation

Recommendation: The finding that a Property needs work on a given target surface — a building part (the MAIN wall, an extension roof…) or a system (heating + hot water + controls, treated as one). Carries one or more mutually-exclusive Measure Options; the Optimiser selects at most one. The target itself is encoded in each Option's Simulation Overlay (which addresses a building part, a specific window, or a system) — never as a typed key on the Recommendation, so the type stays stable as new surfaces land. Recommendations partition the modifiable surface of EpcPropertyData: no two Recommendations write the same field of the same target, so selected Options never collide. Exclusivity between competing treatments (cavity-fill vs EWI; a boiler bundle vs an ASHP) is captured within one Recommendation, never across them. Avoid: suggestion, recommendation engine, keying by measure type (a Recommendation can span measure types — e.g. a heating + hot-water bundle), the persisted selected-measure output line (that is a Plan Measure, which carries impact; a Recommendation never does)

Measure Option: One mutually-exclusive way to satisfy a Recommendation — possibly a bundle of sub-measures (e.g. "new condensing boiler + cylinder insulation"), possibly a single intervention at a chosen size/product (a 4 kWp PV array of product X). Carries its total cost and a Simulation Overlay for its combined effect on the target surface. Cost is intrinsic to the Option; SAP / kWh / carbon impact is not — impact is cascade-conditional (depends on what is already installed) and is produced by scoring, never stored on the Option. Two Options under one Recommendation may share an identical Simulation Overlay (differing only on cost/product) or differ (e.g. PV kWp), so scoring runs per distinct Overlay. Avoid: option (too generic), variant, SKU

Simulation Overlay (type EpcSimulation): The change a single Measure Option makes to a Property's EpcPropertyData, expressed as an all-optional partial mirror of EpcPropertyData and its nested types — covering only the retrofit-relevant surface (walls/roofs/floors, windows, heating + controls, hot water, ventilation, lighting, PV, draughtproofing), never identity/location fields. Targets a specific building part by BuildingPartIdentifier (MAIN, EXTENSION_1..4) so "insulate the cavity wall" addresses the exact SapBuildingPart; targets a specific window by its index in sap_windows (the PDF's W1/W2/W3) — glazing measures address windows directly by number, regardless of which wall they sit on; the window's building-part association is carried separately via window_location (resolved by _window_bp_index), not used for targeting; and targets whole-dwelling systems (e.g. sap_heating) directly. Carries no scores. It is not an EpcPropertyData (composition, not inheritance — an all-None overlay is not a valid EPC). A domain operation folds a baseline EpcPropertyData + an ordered set of Overlays into a throwaway EpcPropertyData handed to the calculator; only the score is kept, the EPD is discarded. Avoid: simulation config (the legacy EPC-API flag object), patch, delta, diff

Product: A catalogue entry a Measure Option installs — insulation, glazing units, heat pumps, boilers, cylinders, PV panels, inverters, batteries — carrying the data to price an Option and shape its Simulation Overlay. Named Product, not material: the catalogue is dominated by equipment and appliances, and a heat pump is not a building material. Read via ProductRepository, which for now combines two inputs — the Products in the database plus a committed costs file holding what the ETL does not yet supply. Single-source unification (ETL-supplied costs) is separate, queued work; legacy Costs.py is retained but queued for deletion. Avoid: material, building material (inaccurate for appliances), part (the per-Option installed line item), SKU

Products (the catalogue collection): The rich in-memory domain collection over Product — an iterable the ProductRepository yields, carrying the cost-composition behaviour a single Product row cannot. Where a simple measure prices as one row (unit cost × area), a composite measure (an ASHP bundle) prices by selecting and summing many priced line items — so Products exposes per-measure cost methods (e.g. ashp_bundle_cost) that filter the relevant catalogue rows and sum them into a Cost. The split is load-bearing: Products owns the catalogue math (line-item lookup + summation from clean cost-inputs) and stays free of EpcPropertyData / the Sap10Calculator; the dwelling interpretation that produces those inputs (sizing a heat pump from heat loss, proxying beds/radiators, detecting a reusable wet system) lives in the modelling layer, which may depend on the calculator. ProductRepository = fetch; Products = behaviour. Avoid: ProductRepository (that is the IO port, not the domain collection), putting sizing/EPC logic on Products

Cost (of a Measure Option): A single fully-loaded total — products + labour + preliminaries + VAT + margin rolled into one figure — plus a separately-carried Contingency. Only contingency is broken out; the rest is not decomposed, as that breakdown proved unhelpful.

Contingency: A per-Measure-Type percentage uplift on an Option's cost covering job-specific risk (e.g. cavity-wall 10%, internal/external wall 26%, ASHP 25% — cf. legacy Costs.CONTINGENCIES). The one cost component carried separately from the fully-loaded total, because the rate is measure-type-specific and meaningful to surface. Avoid: preliminaries (a different, rolled-in 10%), margin

Measure Dependency: A "selecting A requires B" edge between Recommendations, for couplings that are real but that the Optimiser would not choose on its own — e.g. wall (and possibly roof) insulation requires adequate ventilation. The required Option is excluded from the optimiser's candidate pool (it is mandatory-when-triggered, not a free choice) but is injected into the Optimised Package before the package re-score, so its real SAP contribution — which for ventilation is negative — is captured in the true package score and in the undershoot/repair loop. Trigger set is held as data (cf. legacy assumptions.measures_needing_ventilation), not control flow, so extending the triggers (e.g. to roof insulation) is a data edit. Distinct from the legacy post-optimisation best-practice add, which tacked cost on after scoring and so undershot. Avoid: best-practice measure (legacy term), forced measure

Optimised Package: The subset of a Property's Recommendations selected by the Optimiser Service for installation. For an Increasing EPC goal the objective is least-cost-to-target: the cheapest package that reaches the goal band — so it stops at the target and does not overshoot into a higher band, leaving surplus budget unspent. When the target is unreachable within budget, it falls back to the maximum improvement the budget buys (best effort, below target). With no budget it is simply the cheapest package that reaches the target. Reaching the target is judged on the true whole-package re-score (ADR-0016), not on summed per-measure scores. (Other goals — Energy Savings, Reducing CO₂ — don't yet set a target and currently maximise improvement within budget; future work.) Avoid: selected measures, default measures, optimal solution, recommended bundle

Measure Type: The catalogue classification of a retrofit measure (e.g. solar_pv, loft_insulation, ashp); one or more Recommendations reference the same Measure Type with property-specific cost and impact. Avoid: measure (ambiguous), category

Solar Potential: The typed domain projection over a Property's Google Solar buildingInsights response (fetched by Ingestion, persisted whole as JSONB, read by Modelling — never re-fetched). It carries the per-roof-segment geometry the PV simulation needs — azimuthDegrees (→ SAP orientation octant), pitchDegrees (→ SAP pitch), per-segment panel counts, per-segment centre + area (for the Dwelling-Roof Cap), panel capacity, and sunshineQuantiles (→ overshading) — plus the candidate panel layouts (solarPanelConfigs). It is the source of the PV Overlay: the solar Recommendation Generator reads the Solar Potential (NOT the EPC's photovoltaic_arrays, which is the dwelling's existing PV) and builds competing PV Options from it. Distinct from existing/installed PV. Avoid: solar config (ambiguous — the API response vs the chosen array set), Google insights (the raw JSON, not the typed projection)

Footprint Conflation: When Google Solar (typically on medium-quality imagery, and most often for semi-detached / terraced homes) reports the whole building's roof for a single dwelling — merging the target with its attached neighbour — so the Solar Potential describes more roof than the dwelling owns. The failure mode the Dwelling-Roof Cap corrects; without it the array is sized to two or more homes. Avoid: duplicate surfaces (the legacy heuristic's name, not the concept)

Dwelling-Roof Cap: The bound that limits a Solar PV Recommendation's array to the dwelling's own usable roof, defeating Footprint Conflation (ADR-0038). A surface-area budget — the EPC's RdSAP §3.8 roof plan area (roof_area) ÷ cos(pitch) × a usable fraction (~0.5, one non-north plane) — caps the panel count via min(budget, 0.70 × maxArrayPanelsCount), so it is a no-op on correctly-matched homes and only bites under conflation. Segments are ranked by proximity to the dwelling's own lat/long (not Google's building centre) to keep the home's roof and drop the neighbour's. Used only for sizing — distinct from Solar PV Eligibility, which still uses the real Solar Potential, never a roof-area-from-floor-area estimate. Avoid: roof-area haircut (overloads the MCS coverage haircut), double-property halving (the legacy semi-detached-only mechanism this replaces)

Solar PV Recommendation: The single "Solar PV" Recommendation for a Property, carrying competing whole-array Measure Options built from the Solar Potential (ADR-0026). Up to five conservatively-sized array configs (capped, ranked by energy generation as the size-suitability proxy; deliberately not full-roof — imagery can miss obstructions, so a coverage/edge-setback haircut applies per MCS, and the Dwelling-Roof Cap bounds the array to the dwelling's own roof under Footprint Conflation), each offered with and without a battery (≤ 10 Options). Each Option is priced at a single price point from the rate sheet (kWp band + scaffolding-by-elevation + optional battery/diverter) — no multi-product price variants. The PV Overlay sets photovoltaic_arrays (one per segment: peak_power, orientation, pitch, overshading) plus pv_diverter_present, pv_connection, and is_dwelling_export_capable=True (an export meter is ensured post-install); the battery variant adds pv_batteries. Avoid: solar bundle (PV is competing sized Options, not one fixed bundle like ASHP)

Solar PV Eligibility: The rule fixing whether the Solar PV Recommendation is offered (ADR-0026): a house or bungalow, not listed and not heritage, with no existing PV, and a feasible Solar Potential (the Google Solar API returned usable, non-north roof segments). Crucially a conservation area does NOT block PV — panels are offered (installed sympathetically), so the planning gate is not blocks_internal (listed/heritage only), not blocks_external; this is the opposite of an external fabric measure like EWI, and is deliberate (legacy + planning practice allow conservation-area PV on non-prominent roofs). Flats/maisonettes (building-level shared roof) are deferred. Avoid: blocking conservation-area PV (only listed/heritage block), roof-area-from-floor-area estimate (eligibility uses the real Solar Potential)

External Wall Insulation (EWI) / Internal Wall Insulation (IWI): The two competing Measure Options for insulating a solid (non-cavity) main wall — insulation fixed to the outside face (wall_insulation_type = 1) or the room side (wall_insulation_type = 3), both 100 mm at λ = 0.04 W/m·K; the calculator derives the post-insulation U-value from the type + thickness (the lodged cert carries no U-value). IWI additionally lowers the wall's thermal-mass parameter (changing heating demand); EWI does not. Avoid: solid wall insulation (that names the pair, not one Option), cladding, drylining

Wall Insulation Eligibility: The rule fixing which wall Option(s) the main-wall Recommendation offers, by wall construction then planning status. By construction: cavity → cavity fill only (never solid insulation); solid brick / system-built → IWI + EWI; timber-frame → IWI only (EWI is not constructable); cob / granite or whinstone / sandstone or limestone → none (breathable fabric — standard insulation risks trapping moisture). Then, as planning gates: a conservation area or flat removes EWI (external-appearance / whole-block constraints), and a listed or heritage building removes both EWI and IWI (protected fabric). Avoid: restricted measures (legacy collapsed conservation/listed/heritage into one boolean — they now gate different Options, so keep them distinct)

Roof Insulation Eligibility: The rule fixing which single roof Measure the main-roof Recommendation offers, by roof type. One Measure per roof — never a menu the Optimiser chooses between (ADR-0021): pitched with an accessible loft (incl. thatch — the covering doesn't block insulating the loft floor) → loft insulation (laid flat at the ceiling joists, 300 mm); pitched with a sloping ceilingsloping-ceiling insulation (at the rafters, 100 mm); flat roofflat-roof insulation (200 mm); pitched, no access → none (can't reach the void). A room-in-roof takes neither loft nor sloping-ceiling insulation — it is insulated at its own slopes/stud-walls (rafter-area, not floor-area, quantity) as a distinct room-in-roof insulation Measure, currently deferred (pending retrofit-specialist examples). A Measure is offered only when the roof is genuinely uninsulated ("As Built" / "None" / 0 mm). Avoid: "roof insulation" (name the specific Measure — loft / sloping-ceiling / flat-roof / room-in-roof); "joist insulation" (use loft insulation, the established Measure Type)

Glazing Eligibility: The rule fixing the single glazing Measure the Windows Recommendation offers. We upgrade only single-glazed windows (a pragmatic scope — already-double/secondary/triple windows are left alone), all of them together as one Measure. Planning status hard-picks the Measure (not a choice the Optimiser makes — ADR-0022): unrestricted → double glazing (replace the units); a conservation area / listed / heritage building → secondary glazing (an internal second pane, since the external units can't be replaced). Priced at a flat average price per window × the count of single-glazed windows (we have per-window areas but no size-varying prices, so size is ignored). When the dwelling has no single-glazed windows, no Recommendation is offered. Avoid: "windows" as a Measure (name double glazing / secondary glazing); pricing glazing by area (it's per-window count × average)

Lighting Eligibility: The rule fixing the single lighting Measure the Lighting Recommendation offers. We convert all non-LED bulbs (incandescent + CFL + low-energy-unknown) to LED — all the way to LED, not the legacy "fill to low energy", because SAP rates LED efficacy above CFL (ADR-0023). One Measure, no planning gate (lighting isn't planning-restricted). Offered only when the dwelling lodges at least one non-LED bulb; a dwelling already all-LED, or one that lodged no bulb counts (nothing to size against), gets no Recommendation. Unlike the fabric measures it is a whole-dwelling Measure — its Simulation Overlay writes the four top-level bulb counts directly (led = total, others 0), the first overlay surface that isn't a building part / window / system sub-object. Priced at a flat average price per bulb × the count of non-LED bulbs replaced. A free Optimiser candidate (it improves SAP), contrast the forced ventilation Measure Dependency. Avoid: "low energy lighting" as the upgrade target (we go to LED); treating it as a forced dependency (it is a free candidate); pricing by floor area (it's per-bulb count × average)

Coherent Heating System: The set of fields that together describe a dwelling's heating and must move as a unit whenever a heating system is synthesised — never a subset. It spans the main heating cluster (fuel, system, emitter, controls), the hot water it implies, the off-peak meter an electric-storage or CPSU system runs on, and the hot-water cylinder / solar flags. The fields are physically scattered across the EpcPropertyData (a gov-API schema mirror — the cluster, a loose meter on the energy source, loose top-level flags), but the concept is one system. Three places synthesise a heating system and each must cover the whole set with its own fill policy: a Measure Option sets a designed end-state (HHRSH / ASHP), a Landlord Override completes the partial system the landlord named with conservative assumptions for the fields they couldn't tell us (the off-peak meter is derived from the SAP code; an unobserved storage charge control defaults to the conservative manual one), and EPC Prediction's heating donor carries a real neighbour's whole coherent set. Setting only a subset mis-scores: an electric-storage system left on a single-rate meter bills its overnight heat at the peak rate and collapses the SAP. Coherence is owned by the synthesiser, never by the calculator — a real lodged cert is scored exactly as lodged (ADR-0035). Avoid: heating overlay (that is one mechanism, not the field set); meter as a separate concern (it is part of the system); normalising a lodged EPC (coherence is a synthesis-time obligation only)

Heating Eligibility: The rule fixing which Measure Options the single Heating & Hot Water Recommendation offers (ADR-0024, expanded). The competing Options are mutually-exclusive (the Optimiser picks at most one) and fall in two families: whole-system replacementshigh_heat_retention_storage_heaters, air_source_heat_pump — which change main heating + controls + fuel + meter + the implied hot water at once (never a separate HW measure; the legacy heating-vs-HW split double-counted); and, for a dwelling keeping a serviceable wet boiler, partial upgradesgas_boiler_upgrade (a like-for-like condensing gas boiler: gas→gas, or non-gas→gas only where mains gas is present; combi or regular-plus-cylinder, shaped by the dwelling) and the system tune-up (keep the boiler; install better controls + fix the cylinder), the tune-up offered at two competing control levels: system_tune_up (standard, SAP code 2106) and system_tune_up_zoned (time-and-temperature zone control, 2110 — more SAP uplift, more cost). Each Option is a fixed, real, contractor-installable end-state (ASHP via a fixed PCDB heat-pump index; HHR storage via sap_main_heating_code=409; the gas boiler via Table 4b code 102/104; controls via 2106/2110), not a derived ideal; Product stays cost-only, but a partial/bundle cost is composed per dwelling from the components the overlay installs (ADR-0025/0027), not a flat scalar. Eligibility encodes only physical/planning installability — the Optimiser owns the economics, so it must not re-gate on cost proxies: ASHP → houses/bungalows that are not listed/heritage and not already a heat pump (flats excluded — individual siting needs a survey; a conservation area still gets the offer, unlike glazing); HHR storage → off-gas or currently-electric dwellings, not community-heated or already HHR; boiler upgrade / tune-up → an existing (non-electric) wet boiler, the gas end-state gated on a mains-gas connection, a partial control upgrade offered only when it genuinely improves the existing control (never a downgrade or no-op). Floor area, fabric, fuel, and built form are not gates (the legacy ASHP built-form / 120 m² rule is dropped — no authoritative basis). A free Optimiser candidate, not a forced Measure Dependency. Avoid: separate "heating" and "hot water" recommendations (HW folds into each Option); gating ASHP on floor area / built form / fabric (eligibility is physical/planning only — the Optimiser decides cost-effectiveness); treating the whole-system replacements and the partial boiler/tune-up upgrades as separate Recommendations (they are mutually-exclusive Options within the one heating rec — separate recs would let the Optimiser co-select and double-charge); a standalone hot-water-only or controls-only Recommendation (controls + cylinder fold into the boiler/tune-up Option)

Secondary Heating Removal: The rule fixing the single Measure the Secondary Heating Removal Recommendation offers — strip the dwelling's lodged secondary heating system so the main system serves 100% of space heating (ADR-0028). A standalone, co-selectable Recommendation, not an Option in the Heating & Hot Water rec: removing a secondary heater is independent of (and combinable with) a tune-up or boiler upgrade, so it must not be made mutually-exclusive with them. Eligibility is purely physical — offered iff a secondary is lodged (secondary_heating_type is set); since RdSAP only records a secondary when a fixed emitter is present (portable plug-in heaters are ignored), a lodged secondary is by definition a fixed unit worth removing. There is no effectiveness gate: on an electric-storage main, RdSAP §A.2.2 forces a default secondary back, so removal yields zero SAP change — the Optimiser de-selects those (it owns the economics), eligibility does not pre-filter them. The change is a dedicated Simulation Overlay (SecondaryHeatingOverlay) that clears the secondary fields — the one overlay that sets a value to absent rather than to a target state. Priced at a flat per-dwelling decommission cost (one electrician visit to disconnect a fixed/hard-wired heater + localised making-good), not scaled by room count (the EPC carries no heater count). Avoid: making it an Option inside the Heating & Hot Water rec (it is independent, not mutually-exclusive); gating out electric-storage dwellings where removal is a no-op (that is the Optimiser's call, not eligibility's); pricing by room count (the legacy room proxy — the EPC lodges one secondary system with no count); "secondary heating" as the Measure name (name the action: Secondary Heating Removal)

Valuation

Property Valuation: The current open-market value of a Property — an externally-sourced Baseline attribute (customer upload or, later, an estimate), absent for most Properties and never derived from the EPC. Avoid: valuation (ambiguous with Valuation Uplift), market price, current value, house price

Valuation Uplift: The estimated increase in a Property's market value produced by a Plan's retrofit — plan-conditional (it depends on the Plan's target EPC Band) and percentage-primary: always expressible as a % from the Band jump (current → target), and as an absolute £ amount only when a Property Valuation is known. Capped so the £ uplift never exceeds twice the Plan's cost (the cap can only bite once a Property Valuation supplies the £ form — see ADR-0018). Avoid: valuation increase, value gain, financial uplift, property_valuation_increase (pick one — Valuation Uplift is canonical)

Address matching

Lexiscore: A similarity score in [0, 1] between a User Address and a candidate EPC address; combines token overlap and character-level similarity. Avoid: score, match score, similarity

Lexirank: Dense rank of candidates sorted by Lexiscore descending; rank 1 = best match. Avoid: rank, position

UPRN Candidate: An EPC Search Result that is a plausible match for a given User Address, before scoring decides the winner. Avoid: match candidate, result

Score Threshold: The minimum Lexiscore (currently 0.6) below which no match is returned even if a candidate exists. Avoid: minimum score, cutoff

Ambiguous Match: A matching outcome where two or more candidates share Lexirank 1, making it impossible to select a unique winner. Avoid: tie, draw, duplicate

Best Match: The single UPRN Candidate with Lexirank 1 that meets or exceeds the Score Threshold. Avoid: winner, top result

API and integration

EPC Search Result: A lightweight record returned by the government domestic search endpoint — address lines, postcode, UPRN, band, and certificate number, but not full certificate data. Avoid: search row, EPC row, result

EPC Property Data: The fully mapped domain object produced after fetching and parsing a complete EPC certificate; the schema the modelling pipeline operates against. Avoid: EPC data, certificate data, parsed EPC

Old EPC API: The retired government API (epc.opendatacommunities.org) using HTTP Basic auth; decommissioned 30 May 2026. Avoid: legacy API

New EPC API: The replacement government API (api.get-energy-performance-data.communities.gov.uk) using Bearer Token auth. Avoid: new API, current API

Bearer Token: The auth credential required by the New EPC API; stored in the EPC_AUTH_TOKEN environment variable. Avoid: API key, auth token, secret

Team

Who's who on the project, so commit authorship and review history read correctly. The git author names below map to people as follows.

Khalim Conn-Kowlessar: CTO and the technical decision-maker — the boss. Treat his calls as authoritative when guidance conflicts. Git author: Khalim Conn-Kowlessar <kconnkowlessar@gmail.com> (also commits as KhalimCK, same email).

Daniel Roth ("Dan"): Software engineer. Git author: Daniel Roth <daniel_roth@hotmail.co.uk> (also Daniel Roth <36244509+dancafc@users.noreply.github.com>).

Jun-te Kim ("Junte"): Software engineer. Git author: Jun-te Kim <junte.kim@mealcraft.com> (also <juntekim@googlemail.com> and <39764191+kimjunte@users.noreply.github.com>).

Michael Duong: Contractor (software). Git author: Michael Duong <michael123ster@gmail.com> (also commits as <michaelduong22@gmail.com> and from local machine addresses <michaelduong@Michaels-MacBook-Pro.local>, <michael@11s-MacBook.local>).

Relationships

  • A Property represents a single physical dwelling for modelling; identified by (portfolio_id, UPRN) or (portfolio_id, landlord_property_id).
  • A Property has zero or more EPCs across time, exactly one Effective EPC, zero or one set of Site Notes, and zero or one set of Landlord Overrides.
  • An EPC belongs to exactly one Property and has one Certificate Number.
  • An EPC carries an EPC Band and is identifiable by its Registration Date; the most recent one is the current.
  • A UPRN identifies a physical dwelling permanently; it does not change when the property changes owner — but each portfolio gets its own Property keyed against it.
  • When a Property has both Site Notes and a public EPC, the newer of the two derives the Effective EPC. Landlord Overrides apply only when the EPC is the source — never when Site Notes are.
  • A Property's Baseline Performance holds two halves: Lodged Performance (the gov register's SAP / band / carbon / heat) and Effective Performance (what the modelling pipeline scored against). The two are equal unless Rebaselining fires.
  • Rebaselining produces Effective Performance by ML re-prediction across SAP score, CO2 emissions, Primary Energy Intensity, space heating kWh, and hot water kWh, when either (a) the Effective EPC was lodged under a pre-SAP10 schema, or (b) the Effective EPC's physical state diverges from the lodged EPC. Lodged Performance is never overwritten.
  • Bill Derivation derives fuel split and bills from kWh values (sourced from the EPC's renewable_heat_incentive fields for baseline SAP10 properties, or from ML when Rebaselining fires), reading current Fuel Rates and Carbon Factors from their respective repos.
  • EPC Prediction uses Comparable Properties for both gap-filling (the no-EPC path) and producing EPC Anomaly Flags (the has-EPC path).
  • Triggering the model against N Scenarios produces N Plans per Property. Each Plan holds one Optimised Package — its selected Plan Measures — plus the Property's post-retrofit figures.
  • A Scenario Snapshot is pinned at trigger time per (task, scenario) so mid-run edits to the live Scenario do not affect an in-flight modelling job.
  • A Recommendation references one Measure Type and carries property-specific cost and impact.
  • A Property Valuation (current market value) is a Baseline attribute and is mostly absent; a Valuation Uplift is a Plan output, always a percentage from the EPC Band jump and an absolute £ only when a Property Valuation exists.
  • Address Matching uses a User Address and Postcode to find a UPRN by scoring UPRN Candidates from an EPC search. A Lexirank of 1 with no Ambiguous Match and a Lexiscore ≥ the Score Threshold produces a Best Match.

Example dialogue

Dev: "A landlord uploads a corrected boiler for one of their properties. What happens?"

Domain expert: "That's a Landlord Override on the heating fields. Save it against the Property. The Effective EPC has changed, so Rebaselining runs to re-predict SAP / carbon / PEUI / space heating kWh / hot water kWh, and Bill Derivation re-runs to update the fuel split and bills based on the new kWh values and fuel deduction. With fresh Baseline Performance we regenerate Recommendations."

Dev: "What if the same Property also has Site Notes?"

Domain expert: "Site Notes supersede the public EPC, so Landlord Overrides don't apply. We model from the Site Notes version of the Effective EPC. If the public EPC is newer than the Site Notes, that's the one exception — we use the newer one."

Dev: "After modelling we end up with a list of measures. Which ones get installed?"

Domain expert: "The Optimiser Service picks the Optimised Package — a subset of Recommendations that hits the Scenario goal within budget. The rest stay in the Plan as alternatives the user can swap in."

Dev: "I'm looking at a property where the EPC says cavity walls but every other house on the street has solid. Is that a bug?"

Domain expert: "That's an EPC Anomaly Flag. We compute it against the Comparable Properties for that postcode. It's advisory — the UI surfaces it and the landlord can apply a Landlord Override if it's wrong."

Dev: "The property card shows two SAP scores side by side. Why?"

Domain expert: "Those are Lodged Performance and Effective Performance. Lodged is what the gov register says — the EPC was rated under SAP 2012. Effective is what we scored against — we ran Rebaselining to predict the SAP10-equivalent rating because the methodology changed. Both stay on the Baseline Performance so users can see what's on record and what we're modelling against."

Flagged ambiguities

  • "property" was historically warned against in favour of "dwelling"; that has been inverted. Property is now canonical for the Ara domain aggregate. Legacy code still uses "dwelling" in places — treat as alias.
  • "energy assessment" in the existing codebase (energy_assessment_functions, energy_assessments_by_uprn) refers to what is now canonically called Site Notes. New code uses Site Notes.
  • "patch" / patch_epc in the existing codebase has been merged into Landlord Overrides; the original concept is deprecated.
  • "already_installed measures" in the existing codebase is likely subsumed by Landlord Overrides ("we have a heat pump now" → override the heating fields). Final call deferred to implementation.
  • "address" appears as both the raw User Address (free-text from customer data, or the structured UserAddress dataclass that wraps it) and a structured field on an EPC Search Result (normalised lines). Always qualify: "user address" vs "EPC address" or "address line 1". Within domain/, User Address specifically means the UserAddress dataclass; in upstream ingestion contexts (CSV columns, SQS payloads) it can still mean the raw string sense.
  • "score" is used for AddressMatch.score() output, the lexiscore column, and informally. Prefer Lexiscore in domain discussions; reserve "score" for method-level code comments.
  • "user_inputed_address" in backend/address2UPRN/main.py is a misspelling and a synonym for User Address — the canonical term. New code should use user_address.
  • "EPC" is overloaded as both the document and the rating band letter. Use EPC for the document, EPC Band for the letter.
  • "re-scoring" has two meanings in the codebase — Rebaselining (re-predicting baseline performance after an EPC change) and post-optimisation measure re-prediction. Prefer Rebaselining for the former; for the latter, the Optimiser Service step does its own scoring without a special name.
  • "phase" (sequencing measures into ordered steps within a Scenario/Plan) was a speculative, prospective-client feature and is deferred — out of scope (see ADR-0005). It is not a current domain term: a Scenario carries one set of measures, a Plan one Optimised Package. The only live use of "phase" is cut-over timeline language in the PRD ("Phase 0 — Status quo"), which is project-management vocabulary and does not enter code.
  • "valuation" was used for both a Property's current market value and the increase a retrofit produces — resolved into two distinct terms: Property Valuation (current value, a Baseline attribute) and Valuation Uplift (the plan-conditional, percentage-primary increase). The bare word "valuation" should be qualified to one of these.
  • "stale" appears in two senses: cache-freshness ("a Repo record is stale and the orchestrator should refetch") — a legitimate operational concept; and as loose shorthand for the EPC's recorded cost fields being unusable. The cost fields are not stale — they are pinned to the inspection-date fuel rates by design. Use "pinned to inspection date" or "pre-SAP10 schema" (whichever applies) instead.
  • "restricted_measures" (legacy backend/Property.py) collapsed in_conservation_area, is_listed_building, and is_heritage_building into one boolean that blocked EWI only. Resolved: the rebuild keeps the three flags distinct, because they gate different Options — a conservation area blocks EWI but allows IWI, whereas listed/heritage block both (see Wall Insulation Eligibility). Don't reintroduce a single collapsed flag.