`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).
Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.
With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.