Model/backend/documents_parser/tests
Khalim Conn-Kowlessar b473f6a1ec fix(elmhurst-mapper): classify top-floor flat from roof type, not room-in-roof
`_elmhurst_dwelling_type` derived a flat's roof exposure from
`room_in_roof is not None`, so a top-floor flat whose roof is a plain
external "PS Pitched, sloping ceiling" (no room-in-roof) fell through to
"Mid-floor flat". The cascade's `_dwelling_exposure` then treats a
mid-floor flat's roof as a party ceiling (RdSAP 10 §5 / §3 — party
surfaces carry no heat loss) and drops the entire roof term: cert
001431's 105 m² roof at U=2.3 = 241.68 W/K (30) vanished, collapsing
(33) fabric heat loss 320.06 → 78.38 and over-rating SAP by ~5 points
(on top of the age-band roof-U bug — see prior commit).

Read the roof TYPE instead — the dual of the floor's "Another dwelling
below" signal. A flat's roof is a party ceiling only when its Elmhurst
code is S / A / NR (Same/Another dwelling or Non-residential space
above); F / PN / PA / PS are exposed external roofs, so the dwelling is
on the top storey. `has_exposed_roof = room_in_roof present OR
_elmhurst_roof_is_exposed(roof)` — which is exactly what the function's
own docstring already described as the intent ("RR present or external
roof"), now implemented.

With both upstream fixes the full chain (Summary PDF → extractor →
mapper → cert_to_inputs → calculator) reproduces the worksheet's §11a
unrounded SAP 56.3649 at abs < 1e-4, with (30)/(33)/(37) matching to
the decimal. Only flat fixture reclassified; 000784 (top-floor, RR) and
000910 (ground-floor) unchanged. Regression suite green bar the 3
pre-existing unrelated fails.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-10 08:18:51 +00:00
..
fixtures fix(elmhurst-extractor): read Main Property age band from §3.0 Date Built block 2026-06-09 16:41:00 +00:00
__init__.py Map to RdSapSiteNotes from site notes JSON 🟥 2026-04-16 13:54:03 +00:00
test_elmhurst_end_to_end.py Slice S0380.17: map Elmhurst §11 glazing-type labels to SAP10 codes 2026-05-27 23:05:52 +00:00
test_elmhurst_extractor.py fix(extractor): drop windows-table header remnant from first window glazing type 2026-06-02 22:54:49 +00:00
test_end_to_end.py P6.1 follow-on: unbox BuildingPartIdentifier at backend boundaries 2026-05-20 09:58:23 +00:00
test_extractor.py Handle wall thickness "Unmeasurable" 🟩 2026-04-30 16:41:16 +00:00
test_heating_systems_corpus.py S0380.185: record CH6 pin-forever proof — distribution-loss is a Summary-export gap 2026-06-02 19:21:28 +00:00
test_pdf.py rename example site notes to PasHub_ and add Elmhurst example 2026-04-24 13:01:51 +00:00
test_room_heater_worksheet_001431.py S0380.239: system-build walls take masonry structural infiltration (0.35) 2026-06-05 19:00:02 +00:00
test_summary_pdf_mapper_chain.py fix(elmhurst-mapper): classify top-floor flat from roof type, not room-in-roof 2026-06-10 08:18:51 +00:00