A "Pitched, sloping ceiling" (roof_construction == 8) lodges its
insulation in the dedicated `sloping_ceiling_insulation_thickness` field,
not `roof_insulation_thickness` (which stays None — the loft-joist field
is meaningless for a slope-following ceiling). The schema dataclasses
dropped that field, so `from_dict` discarded it and the cascade treated
the slope as uninsulated; worse, the pre-1950 None-fallback forced 0 mm
(U=2.30), over-stating roof heat loss ~74%.
Surface the field on SapBuildingPart (schemas 21.0.0 / 21.0.1) and prefer
it in `_api_resolve_sloping_ceiling_thickness` when it carries a NUMERIC
thickness: "100mm" now reaches Table 17 column (1a) "Insulated slope –
sloping ceiling, mineral wool/EPS" (RdSAP 10 §5.11.3 p.44 — 100 mm →
U=0.40) instead of 2.30. Categorical lodgements ("AB" As Built / "NI")
are not measured thicknesses, so they fall through to the existing
as-built rule (Table 18 col (3) via is_pitched_sloping_ceiling).
Cert 9884-3059-9202-7506 (code 8, age B, sloping 100 mm): SAP −5.54 → +0.06.
Cert 8036-2925-6600-0202: −4.94 → +1.55. No regressions in the roof-8
cohort (the "AB" certs are unchanged). Eval headline 43.8% → 44.3% within
0.5; golden fixtures incl. 6035 green.