The Modelling glazing overlay's draught-proofing recompute (RdSAP 10 §8.1 —
a count over openable windows + doors) needs every openable window captured
with its draught_proofed flag. cert 001431's §11 lodges 17 windows but only
14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal. The backstop's only
pinned cert (000516 W6) hand-builds its sap_roof_windows and so is
unaffected.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows, 14
draught-proofed — reconstructing Elmhurst's lodged 84% (16/19 = (14 windows
+ 2 doors) / (17 windows + 2 doors)). Full calculator + modelling +
orchestration suites green (1885 pass); the 2 glazing draught-proofing
xfails remain (the overlay recompute is the glazing agent's front).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the lighting generator (ADR-0023): run recommend_lighting in
_candidate_recommendations (no planning gate). Price low_energy_lighting in the
offline catalogue + contingency table (0.26, the legacy rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both. A run_modelling test pins
the wiring end-to-end (an incandescent-lit dwelling gets the LED upgrade in the
optimised package).
Downstream updates, all because lighting now fires on any cert with non-LED
bulbs: report.py gains the low_energy_lighting trigger (the non-LED counts); the
two golden-cert report tests and the multi-measure integration test now expect
low_energy_lighting alongside the fabric measures (the sample/golden EPCs lodge
low-energy-unknown bulbs); first-run integration seeds a low_energy_lighting
MaterialRow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the lighting generator (ADR-0023): two real Elmhurst before/after
cascade pins, sourced from the low_energy_lighting recommendation folder. Both
close cleanly at 1e-4 with NO xfail — lighting changes only bulb counts →
Appendix L (232), no fabric coupling (contrast glazing's draught-proofing).
- zero existing LEDs: 20 incandescent → 20 LED
- some existing LEDs: 5 LED + 15 incandescent → 20 LED (partial-upgrade path)
The overlay-emits-correct-counts assertion lives in the Slice 2 unit tests.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of the lighting generator (ADR-0023): detect non-LED bulbs
(incandescent + CFL + low-energy-unknown > 0) and emit one "Lighting"
Recommendation whose single low_energy_lighting Option converts every bulb to
LED — the overlay sets led = total, the other three counts 0. Priced as a flat
per-bulb average x the non-LED count, contingency 0.26; the description names
"LED" while the measure_type stays MEASURE_MAP-aligned. None when already
all-LED or no bulb counts are lodged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the lighting generator (ADR-0023): the first whole-dwelling,
top-level overlay surface. LightingOverlay carries the four fixed-lighting
bulb-count fields by their exact EPC names (all Optional, absolute counts) +
EpcSimulation.lighting. The applicator's _fold_lighting writes the non-None
counts directly onto the result EpcPropertyData by name (setattr) — simpler
than ventilation's nested fold since the counts live top-level. Baseline
unmutated; pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
With the mapper now in main, cert 001431 parses: it lodges four single-glazed
windows — codes 1 ("Single") and 15 ("single glazing, known data", a single
pane with manufacturer U/g). The generator only detected code 1, so it missed
two panes. Detect {1, 15}; set the secondary target to code 11 ("Secondary
glazing - Normal emissivity", what the cert re-lodges; score-neutral vs 7 but
exact).
A deterministic green pin proves the overlay reproduces the after's 14 windows
exactly. The full-SAP before->after pins are xfail(strict) tripwires: the
overlay nails the windows, but the measure also re-lodges percent_draughtproofed
84->100 (sealed units draught-proof the replaced openings) plus a ~0.4 SAP
fabric residual the overlay doesn't model yet — a glazing-measure coupling to
close later.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0019 warns that wall_construction code 8 is Park home (PH), NOT system-
built. It was already excluded (8 isn't in the constructable-options map), but
only implicitly. Add an explicit early-return + named constant so a park home
can never be mis-keyed as system-built, with a pin as the tripwire. A park
home's proprietary panel is never EWI/IWI-suitable.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PR feedback (dancafc): the SQLModel column was Optional[str], but the
domain `SapBuildingPart.wall_insulation_thickness` is Optional[Union[str,
int]] — `_api_resolve_wall_insulation_thickness` returns an int mm when the
API lodges `wall_insulation_thickness == "measured"` (SAP 10.2 §5.7 /
Table 8). The plain str column round-trips that int back as the string
"100", corrupting the Table 8 insulated-wall U-value lookup.
This column was missed in the round-trip-fidelity §1 JSONB sweep
(#1129) — its `Union[str, int]` sibling `roof_insulation_thickness` was
converted, but `wall_insulation_thickness` was not, and no 21.0.0/21.0.1
fixture lodges "measured" so the gap stayed latent. Convert to JSONB
(matching `roof_insulation_thickness` / `flat_roof_insulation_thickness`),
align the column type to Optional[Union[str, int]] (also removes a pyright
type-mismatch), record it in the migration doc §1, and add a round-trip
guard test asserting an int survives as an int (fails as '100' == 100 on
the old str column).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The merged per-cert-mapper-validation work disambiguates Elmhurst 'SY System
build' from 'B Basement wall' (both lodged wall_construction=6), so
main_wall_is_basement is no longer wrongly True for system-built and the
solid-wall generator offers EWI+IWI. The strict xfail now XPASSes; drop the
marker so it stands as a real green cascade pin.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A room-in-roof carries its insulation on its own sloping/stud/gable surfaces
(RdSAP 10 §3.10, Table 17/18), which the roof overlay's flat
roof_insulation_thickness bump cannot model. Without a guard a RR with an
uninsulated loft fell through to the loft fallback and mis-recommended 300 mm
loft insulation. Return None when the main part lodges a sap_room_in_roof,
deferring until a dedicated RR branch lands (ADR-0021).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The worksheet build_epc() fixtures wrapped a module-level SECTION_6_VERTICAL_
WINDOWS tuple in list(), so every call returned the SAME SapWindow objects. A
test that mutated a returned window (the glazing slices flip glazing_type to
single) leaked that change into every later build_epc() -- which surfaced as
double_glazing-product failures in the first-run integration tests only when
test_console ran first in the same process.
Deep-copy the windows per call in all six fixtures (000474/477/480/487/490/516)
so each EpcPropertyData owns an independent window graph, and drop the
now-redundant defensive copy at the glazing test's call site.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the glazing generator (ADR-0022): run recommend_glazing in
_candidate_recommendations, threading the Property's PlanningRestrictions so a
protected dwelling is offered secondary glazing instead of double (mirrors
recommend_solid_wall). Price both Measure Types in the offline catalogue
(double £600/window, secondary £510 -- the legacy 0.85x scaling) and the
contingency table (0.15, the legacy windows_glazing rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both entries exist.
run_modelling tests pin the wiring end-to-end on an all-single-glazed dwelling:
double when unrestricted, secondary when listed. The first-run integration test
seeds a double_glazing Product because its lodged EPC has a single-glazed
window. _single_glazed_epc() deep-copies build_epc() (which shares its window
objects) so the mutation can't leak into other tests' baselines.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the glazing generator (ADR-0022): a conservation/listed/heritage
protection (PlanningRestrictions.blocks_external) hard-picks secondary_glazing
instead of double_glazing -- an internal second pane, since the external units
can't be replaced on a protected building. Each single-glazed window upgrades
to the secondary target pinned from cert 001431 (glazing_type=7, u_value=2.90,
solar_transmittance=0.85 -- the outer single pane still drives solar gain).
The before/after cascade pins for both measures remain deferred behind the
glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The glazing Recommendation Generator (ADR-0022): detect single-glazed
windows (SAP10.2 Table U2 code 1) and emit one "Windows" Recommendation whose
single Option rewrites every single-glazed window to the double-glazing target
pinned from cert 001431's before->after (glazing_type=5, u_value=1.40,
solar_transmittance=0.72). The overlay writes the per-window U/g into
WindowTransmissionDetails because the calculator consumes those directly.
Priced as a flat per-window average x count. No single-glazed windows -> None.
Planning gate (-> secondary) and the before/after cascade pins land next; the
pins are blocked on glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The double_glazing / secondary_glazing Elmhurst before→after Summaries the
glazing generator's cascade pins will use (ADR-0022). NB: these don't parse
yet — cert 001431 lodges several unmapped glazing labels ("Secondary glazing",
"Secondary glazing - Normal emissivity", "Triple pre 2002", truncated
"Double…"/"Triple…" variants) that the mapper must cover first.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix G4 (PDF p.72-73). A PV diverter routes surplus PV
generation (the would-be export EPV,m × (1 − βm)) to an immersion heater
in the hot-water cylinder. Per G4 step 4:
SPV,diverter,m = EPV,m × (1 − βm) × 0.8 × fPV,diverter,storageloss
(0.8 = cylinder heat-acceptance; fPV,diverter,storageloss = 0.9 for the
higher storage temperature), clamped to ≤ (62)m + (63a)m, and entered as
the negative worksheet (63b)m (step 5). The β factor is computed on the
PRE-diverter (219) per the §3a note (lines 5485-5486). Effects:
- (64)m = (62)m + (63b)m → less main-system water-heating fuel (219);
- export drops to EPV,ex,m = EPV,m(1 − βm) + (63b)m / 0.9 (§4 p.94
line 5501); the onsite dwelling portion EPV,m × βm is unchanged.
Inclusion (G4 step 1) requires ALL of: a PV system connected to the
dwelling; a cylinder larger than (43) average daily HW use; no solar
water heating; no battery — else the diverter is disregarded.
Three layers:
- extractor reads Summary §19 "Diverter present"; schema 21.0.0/21.0.1
SapEnergySource gains `pv_diverter` (API `sap_energy_source.pv_diverter`);
- `Renewables.pv_diverter_present` + domain `SapEnergySource.pv_diverter_present`,
set in both the Elmhurst and API mapper paths;
- `_pv_diverter_monthly_kwh` applies the G4 math after the β split;
`cert_to_inputs` recomputes (219) and the PV export.
On simulated case 19 (electric storage heaters, 7-hour, PV + diverter):
SAP continuous 50.33 → 51.34 (worksheet 51.2221; both round to the
lodged 51), cost (255) 1847.5 → 1812.3 (ws 1816.6), CO2 (272) 3331 →
3120 (ws 3126), with (233a) dwelling 1280.6 (ws 1280.4). The residual
+0.11 SAP is an upstream winter Appendix-M monthly-EPV-shape gap +
fabric (33) +1.0, tracked as the next case-19 cause. Suite: 2412 pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix M1 §6 (PDF p.94, lines 5510-5513): "apply the normal
import electricity price to PV energy used within the dwelling and the
'electricity sold to grid, PV' price from Table 12 to the energy
exported. In the case of the former, use a weighted average of high and
low rates (Table 12a)."
`_pv_dwelling_import_price_gbp_per_kwh` was returning the bare off-peak
LOW rate (5.50 p/kWh on a 7-hour tariff) for the PV-used-in-dwelling
credit. PV self-consumption displaces the dwelling's "all other uses"
electricity (lighting / appliances / pumps), which on an off-peak tariff
bills at the Table 12a Grid 2 ALL_OTHER_USES weighted blend, not the low
rate. On simulated case 19 the worksheet (252)/(269) credits
PV-used-in-dwelling at 14.3110 p/kWh = 0.90 × 15.29 + 0.10 × 5.50; we
credited it at 5.50, under-crediting onsite PV by ~£0.088/kWh on every
off-peak PV cert.
Fix delegates to `_other_fuel_cost_gbp_per_kwh(tariff, prices)` (the same
ALL_OTHER_USES rate): STANDARD tariff still returns the flat Table 32
code 30 13.19 p/kWh (golden cohort unchanged — all 2412 tests pass);
off-peak returns the weighted high/low blend. Call sites now pass the
resolved `_rdsap_tariff(epc)`. The now-unused
`_off_peak_low_rate_gbp_per_kwh_via_meter_heuristic` (its only caller)
is removed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the glazing generator (ADR-0022). `WindowOverlay` (all-optional
partial of one SapWindow) + `EpcSimulation.windows` keyed by sap_windows index.
The applicator folds it onto sap_windows[i]: glazing_type flat on the window,
u_value/solar_transmittance routed into its WindowTransmissionDetails (created
if absent) — the applicator's first nested write, because that's where the
calculator reads window heat loss and solar gain. Baseline left unmutated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix M1 §3a (PDF p.93, lines 5470-5476): "E_space,m =
(211)m + (213)m + (215)m, where (211), (213) and/or (215) should be
included only where the fuel code applied to them in Section 10a of the
SAP worksheet is 30, 32, 34, 35 or 38 (i.e. electricity not at the
low-rate)."
The PV-eligible demand D_PV,m was adding 100% of the main space-heating
fuel (211)m whenever the main's Table-12 code was in the eligible set
(30, …), ignoring the off-peak high/low split that §10a already bills
via `_space_heating_fuel_cost_gbp_per_kwh`. Electric STORAGE heaters on
a 7-hour tariff are charged wholly at the low rate (Table 12a Grid 1 SH
fraction 0.00; worksheet (240) high-rate cost = 0), so none of (211)
may enter D_PV — but the cascade counted it all, inflating R_PV,m =
E_PV,m / D_PV,m and therefore the β onsite-PV split in the heating
months.
Fix mirrors the cost-side rate split: `_main_space_heating_high_rate_
fraction(main, tariff)` returns the high-rate portion (1.0 for
non-electric / STANDARD, the published Grid 1 SH fraction otherwise,
0.0 when the Grid 1 SH row is unwired → 100% low rate), and
`_pv_eligible_demand_monthly_kwh` scales the (211)m contribution by it.
Backward-compatible: STANDARD-tariff electric mains and the gas-main /
electric-secondary PV cohort are unchanged (fraction 1.0).
On simulated case 19 (electric storage heaters, 7-hour, PV) this takes
β_Jan 0.894 → 0.792, matching the worksheet 0.791, and the summer months
(no main heating) already pinned exactly.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 (ADR-0021). The roof dispatcher can now emit sloping_ceiling_insulation
and flat_roof_insulation, so wire both into contingencies and the sample
catalogue; the forcing-function test now asserts every generator measure type
is both priced and has a contingency rate, so an offline/live run over a
sloping or flat roof never dies on a missing entry.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The gov-EPC API mapper sets BOTH roof_construction (int) and
roof_construction_type (str, derived via _API_ROOF_CONSTRUCTION_TO_STR),
but the Elmhurst mapper set only the string — leaving roof_construction
None on every site-notes cert. The SAP cascade reads the STRING (so SAP
cross-mapper parity always held), but consumers of the int (e.g.
domain/sap10_ml/transform.py ML aggregates `main_dwelling_roof_
construction`) silently saw None on the Elmhurst path.
New `_elmhurst_roof_construction_int` maps the Elmhurst roof-type code to
the same SAP10 int the API lodges (F→1, PN→3, PA→4, PS→8, S/A→7),
harvested from the committed Summary fixtures. Unlike the wall map it
returns None (not a strict-raise) for unmapped codes: the int is not
cascade-load-bearing, so an unknown roof must not block the cert (vaulted
5 / thatched 6 / NR omitted until a fixture surfaces them).
The 6 hand-built U985 reference fixtures gain the matching
roof_construction int (4/4/3 etc.) so test_from_elmhurst_site_notes_
matches_hand_built_* still asserts structural parity. SAP output is
unchanged (cascade reads the string). §4 suite green (2407 passed); the
two pre-existing stone-§5.6 sap10_ml failures are unrelated/out of scope.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 (ADR-0021). The dispatcher gains a flat-roof branch: a "flat"
roof_construction_type with no lodged thickness (uninsulated → None on the
Elmhurst path) gets a single flat_roof_insulation Option whose overlay raises
roof_insulation_thickness to 200 mm — tested before the loft fallback so a flat
roof's None doesn't trip the loft trigger. Pinned against the Elmhurst
before→after cert at 1e-4. Golden cohort roof firing unchanged (none across 57).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 (ADR-0021). `recommend_roof_insulation` now owns the loft branch as the
fallback — a plain pitched loft, a thatched roof (the covering doesn't block
insulating the loft floor), or an unlodged roof type all take loft (joist)
insulation at 300 mm when `roof_insulation_thickness == 0`. Sloping is tested
first; a no-access roof gets nothing. Retired the standalone
`recommend_loft_insulation`; the orchestrator and its tests now call the
dispatcher.
Pinned: thatch before→after (None→300) reproduces at 1e-4; the existing loft pin
still holds through the dispatcher. Behaviour-preserving on the golden cohort
(roof measure unchanged: none across all 57) — the dispatch is strictly more
precise (won't fire loft on a sloping/no-access roof).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the roof-insulation generator (ADR-0021). New `recommend_roof_insulation`
dispatcher keys on the `roof_construction_type` string: a "sloping ceiling" roof
that is uninsulated (roof_insulation_thickness 0/None) gets a single
`sloping_ceiling_insulation` Option whose overlay raises roof_insulation_thickness
to 100 mm. Pinned against the Elmhurst before→after cert 001431 at 1e-4.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §12 (PDF p.62) Dual-meter dispatch: "the choice between 7-hour
and 10-hour is made by the main heating type ... if the main system is a
direct-acting electric boiler (191), or electric room heaters ... it is
10-hour tariff." The electric room-heater codes — Table 4a 691 (panel/
convector/radiant), 692 (fan), 693 (portable), 694 (water-/oil-filled),
699 (assumed) — were missing from `_RULE_3_TEN_HOUR_CODES` (the long-
standing TODO there), so a Dual-meter room-heater cert fell through to
Rule 4 (7-hour default).
Compounded with S0380.230 (which routes room heaters to Table 12a
OTHER_DIRECT_ACTING_ELECTRIC): at 7-hour the high-rate fraction is 1.00
(all at 15.29 p), but at the correct 10-hour it is 0.50 split over the
10-hour rates (14.68 / 7.50 p) → blended ~11 p. Without this fix .230
over-charged and flipped the cluster from over- to under-rating.
1,000-cert 2026 API sample: cat-10 mean |err| 7.11 → 5.26, signed mean
+5.08 → -0.86 (now balanced, 22 over / 26 under — the systematic
directional bias is gone). Overall mean |err| 2.16 → 2.04. Full §4 suite
green (2406 passed).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Table 12a Grid 1 (PDF p.191): an electric room heater (RdSAP
main_heating_category 10, e.g. SAP code 691) is direct-acting electric,
so it sits on the "Other systems including direct-acting electric" row —
7-hour high-rate fraction 1.00, 10-hour 0.50. It runs on demand, mostly
at the HIGH rate; it does NOT earn the 100%-low-rate of overnight storage
charging (which is category 7).
`_table_12a_system_for_main` only mapped ASHP, so an electric room heater
fell through to the "100% low-rate" fallback (5.50 p, £0.0550), under-
charging space heating by ~9.79 p/kWh and systematically OVER-rating the
cluster. Now maps electric cat-10 mains to OTHER_DIRECT_ACTING_ELECTRIC
(gated on `_is_electric_main`, so gas/solid-fuel cat-10 room heaters are
excluded). The same Table 12a fraction flows through cost, CO2 (Table
12d) and PE (Table 12e) — all three callers already pre-gate on electric.
Mirror of S0380.228 (same fallback bug for electric SECONDARY heating).
1,000-cert 2026 API sample (no worksheet for this cluster — ±0.5-vs-lodged
fallback bar): cat-10 mean |err| 9.49 → 7.11, %<0.5 10.4% → 16.7%;
headline %<0.5 42.5% → 42.9%, overall mean |err| 2.29 → 2.16. cat-7
(storage) and cat-2 (gas) unchanged. Full §4 suite green (2405 passed).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP10 `wall_construction == 6` is canonically WALL_SYSTEM_BUILT — a
WALL TYPE — but the gov-EPC basement heuristic hijacked it: Elmhurst
lodges both "SY System build" and "B Basement wall" as code 6, and the
API lodges basements as code 6 too, so a system-built wall was
mis-flagged `main_wall_is_basement` → wrong RdSAP §5.17 / Table 23
u_basement_wall/u_basement_floor overrides, and downstream the solid-wall
Recommendation Generator couldn't offer EWI/IWI on system-built walls.
System-built stays the wall type on its canonical code 6; the basement
signal moves OFF code 6 to a dedicated `is_basement` (SapAlternativeWall)
/ `wall_is_basement` (SapBuildingPart) Optional[bool] flag:
- Elmhurst: `_elmhurst_wall_is_basement` sets it from the distinct
"SY"/"B" labels (False for SY, True for B, None otherwise).
- gov-EPC API: per-wall code 6 can't be told apart at lodging time, so
`from_api_response` post-processes via `_clear_basement_flag_when_
system_built` — when the cert addendum marks the dwelling system-built,
the code-6 basement heuristic is cleared. A genuine basement (no
addendum signal) keeps the code-6 fallback.
- `main_wall_is_basement` / `is_basement_wall` honour the flag when set,
else fall back to the code-6 heuristic — so untouched API basements and
the cert 000565 "B" cohort are unchanged.
`EpcPropertyData.system_build` is a derived property over the wall type:
the MAIN wall is system-built iff `wall_construction == 6` and it is not
flagged basement. System-built lives on `wall_construction`; the basement
attribute is separate.
Acceptance: a system-built main wall (Elmhurst SY, or API addendum
system_build) → wall_construction == 6, main_wall_is_basement is False,
system_build is True; a genuine basement main wall → main_wall_is_basement
is True, system_build is False. Full §4 suite green (2404 passed).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP10 `wall_construction == 6` is canonically WALL_SYSTEM_BUILT, but
the gov-EPC basement heuristic hijacked it: Elmhurst lodges both "SY
System build" and "B Basement wall" as code 6, so a system-built wall
was mis-flagged `main_wall_is_basement` and routed to the RdSAP §5.17
`u_basement_wall` override instead of the system-built U-value table.
System-built stays on its canonical code 6; the basement signal moves
to an explicit `is_basement` (SapAlternativeWall) / `wall_is_basement`
(SapBuildingPart) Optional[bool] flag, set by the Elmhurst mapper from
the distinct "SY"/"B" codes via `_elmhurst_wall_is_basement` (True for
B, False for SY, None otherwise). The `main_wall_is_basement` /
`is_basement_wall` properties honour the flag when set and fall back to
the gov-EPC API code-6 heuristic when None — so the API path (basement
lodged as integer 6, no flag) and the cert 000565 "B" cohort are
unchanged.
Acceptance (a recommendation-summary generator depends on it): a
system-built MAIN wall reports wall_construction == 6 AND
main_wall_is_basement is False; a genuine basement main wall still
reports main_wall_is_basement is True.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Table 3 (PDF p.160) row 1: primary circuit loss applies when
"hot water is heated by a heat generator (e.g. boiler) connected to a
hot water storage vessel via insulated or uninsulated pipes". The Table
4a hot-water-only codes (PDF p.166) 911 gas / 912 liquid / 913 solid
boiler-circulator + 921-931 range cooker with boiler are each a heat
generator feeding the cylinder through a primary loop.
`_primary_loss_applies` keyed only off the resolved DHW `main` — but for
these certs `_water_heating_main` returns the SPACE main (e.g. electric
storage heaters, SAP code 402, which has no primary loop), so every
boiler branch missed the gas water-boiler's primary circuit and (59)m
went to zero. New branch keys off `water_heating_code` ∈
`_WATER_HEATING_BOILER_CIRCULATOR_CODES`. 941 (electric HP for water
only) is excluded — HP DHW vessels follow the Table 3 integral-vessel
rules.
Simulated case 19 (electric storage main + WHS 911 + 210 L cylinder):
(62)m total HW demand 2493.30 → 3169.98 kWh/yr, matching the worksheet
(the missing 676.68 kWh/yr = the worksheet's (59) primary-loss annual
sum, h=5/p=0). The remaining (64)/(219) gap is the PV diverter (63b),
deferred to its own slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Reference the calculator-side wall_construction=6 disambiguation issue from the
strict-xfail tripwire and ADR-0019, so the blocker is traceable both ways.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
System-built (precast/no-fines concrete) takes both solid-wall Options like
solid brick (ADR-0019), keyed on `wall_construction == 6` (WALL_SYSTEM_BUILT,
Elmhurst `SY`). A basement-suitability guard (`main_wall_is_basement`) is added
since a below-ground basement wall is never EWI/IWI-suitable.
This is currently inert: `B Basement wall` also maps to 6 (mapper.py:2100) and
`main_wall_is_basement` is derived as `wall_construction == 6`, so every code-6
wall reads as basement and is guarded out — the live cohort is unchanged. The
system-built EWI/IWI cascade pin is committed as a strict-xfail tripwire that
flips green the moment the calculator disambiguates system-built from basement
(MAIN wall_construction==6 with main_wall_is_basement False). `wall_construction
== 8` is Park home, not system-built — not keyed.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Table 12a Grid 1 (PDF p.191): secondary heating is a direct-
acting electric room heater (RdSAP 10 §A.2.2 default), on the "Other
systems including direct-acting electric" row — 7-hour high-rate fraction
1.00, 10-hour 0.50. A room heater runs on demand, mostly at the high
rate; it does NOT earn the 100%-low-rate of overnight storage charging.
`_secondary_fuel_cost_gbp_per_kwh` previously returned the flat off-peak
LOW rate (5.50 p, £0.0550) for every off-peak electric secondary, under-
charging by 9.79 p/kWh. New `_secondary_off_peak_rate_gbp_per_kwh` mirrors
`_space_heating_fuel_cost_gbp_per_kwh`: it blends the Table 12a high-rate
fraction (OTHER_DIRECT_ACTING_ELECTRIC) against the Table 32 high/low
rates, with the 18-/24-hour fallback to the low rate.
Simulated case 19 (electric storage main + electric secondary, Dual/7-hour
meter) is the worksheet case (242): "Space heating - secondary
(1.00*15.29 + 0.00*5.50)" → 15.29 p/kWh = £0.1529. This was the primary
cat-7-cluster cost driver: total cost 1485.68 → 1835.53 (worksheet
1816.58), SAP cont 60.11 → 50.67 (worksheet ~51.22). Remaining +19 cost
is HW/space-heating kWh (next slices).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.6. The integrating proof through real Postgres: two solid-brick
uninsulated dwellings, identical but for the planning status Ingestion caches
per UPRN. Ingestion writes the spatial reference; Modelling reads it back off
the Property and gates the wall measures — the listed dwelling gets neither
EWI nor IWI, the unrestricted one gets a wall measure. Closes slice 3c
(ADR-0019/ADR-0020).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Table 2b note b (PDF p.159) applies the ×0.9 temperature-factor
reduction only when DHW is "separately timed" relative to space heating
on a SHARED heat generator ("boiler systems, warm air systems and heat
pump systems"). Per RdSAP 10 §10.5.1 (PDF p.55) a separate boiler/
circulator providing DHW only (water-heating code 911 = "Gas boiler/
circulator for water heating only") is NOT the main space-heating system
— so there is no shared timer to apply the ×0.9 against. `_separately_
timed_dhw` now returns False when water_heating_code is not "from main /
2nd-main system" ({901,902,914}), mirroring the existing WHC 903 electric-
immersion carve-out.
Simulated case 19 (electric storage main SAP 402 + WHS 911 + 210 L
loose-jacket cylinder) is the worksheet case. The single flag drives both:
- (53) Temperature factor: 0.54 → 0.6000 (worksheet base, no ×0.9)
- (55) storage loss/day: → 3.4531; (56)/(57)m Jan → 107.0456 (1e-4)
- (59)m primary loss: h=3 (43.31) → h=5 (Jan 64.5792), worksheet-exact
This also worksheet-pins S0380.224's loose-jacket storage loss magnitude
at 1e-4, previously only direction-validated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.5. `PropertyPostgresRepository` takes an injected `SpatialRepository`
and hydrates `Property.planning_restrictions` by UPRN (bulk in `get_many`,
single in `get`). A UPRN with no cached row — or a property with no UPRN —
defaults to unrestricted, matching legacy `empty_spatial_df` (ADR-0020). This
closes the loop: Ingestion caches the protections, Modelling reads them off the
Property to gate solid-wall EWI/IWI (ADR-0019).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.4. Ingestion now resolves the whole spatial reference in one lookup
(`spatial_for`) — the coordinates drive the Solar fetch as before, and the
reference (coordinates + planning protections) is persisted per-UPRN via
`uow.spatial` in the same write batch, so Modelling can read the protections
back off the Property (ADR-0020). `_Fetched` carries the UPRN and the reference
into the write phase.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.3. Ingestion writes the OS spatial reference cache through the same
unit it persists the EPC/solar enrichments with, so `UnitOfWork` declares a
`spatial` repo, `PostgresUnitOfWork` binds a `SpatialPostgresRepository` to the
session, and `FakeUnitOfWork` gains a `FakeSpatialRepo` (seedable for read
tests, recording writes for ingestion-side assertions).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.2. The OS Open-UPRN reference set is too large to host in Postgres, so
it lives in S3 and is cached per-UPRN in the existing `property_details_spatial`
table (ADR-0020). `PropertyDetailsSpatialRow` mirrors that table (uprn unique);
`SpatialRepository` / `SpatialPostgresRepository` upsert one shared row per UPRN
and read the planning protections back by UPRN (a null flag reads as
unrestricted; absent UPRNs are omitted so the caller defaults them).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3c.1. Ingestion will persist a UPRN's coordinates and planning
protections together as a write-through cache, so resolve them in a single
partition read rather than two. `SpatialReference` bundles the coordinates
(which drive the Solar fetch) and the `PlanningRestrictions` (which gate wall
insulation per ADR-0019/ADR-0020); `GeospatialRepository.spatial_for(uprn)`
returns it, and `coordinates_for`/`planning_restrictions_for` now delegate to
the one lookup.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3b+3d (ADR-0019/0020). Property gains a planning_restrictions attribute
(default unrestricted); the ModellingOrchestrator threads it from the Property
through _plan_for -> _scored_candidate_groups -> _candidate_recommendations into
recommend_solid_wall, replacing the unrestricted default. run_modelling exposes
a planning_restrictions param so the offline harness can inspect restricted
properties. Integration test: a listed solid-brick dwelling that gets IWI when
unrestricted now yields no wall insulation. 145 tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The §10.7 no-water-heating default cylinder raised UnmappedSapCode for
age bands A-F (2 certs in a 2026 sample, bands B + C) because Table 29's
"A to F: 12 mm loose jacket" row wasn't plumbed — the loose-jacket
storage-loss branch didn't exist. S0380.224 added it, so this slice
completes the Table 29 lookup.
Restructure _TABLE_29_DEFAULT_CYLINDER_INSULATION_BY_AGE to carry
(cylinder_insulation_type, thickness_mm) per band — A-F → (loose jacket,
12), G/H → (factory, 25), I-M → (factory, 38) per RdSAP 10 Table 29
(PDF p.56) — and have the default read both, setting the loose-jacket
type for A-F instead of hardcoding factory. The strict-raise is retained
only for an absent / out-of-A-M age band (no Table 29 row).
Validated: certs 2211 (band B, SAP 49.8 vs lodged 52) and 3420 (band C,
11.2 vs 11) now compute. §4 + golden suite 2395 passed — the corpus
"no system" cert (age G, 25 mm factory) is unchanged. cert_to_inputs.py
pyright unchanged at 32; new test suppresses reportPrivateUsage.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3a (ADR-0020). PlanningRestrictions relocated out of the solid-wall
generator into domain/geospatial/ as the shared, Property-level value object
(three distinct flags + measure-specific blocks_external/blocks_internal).
GeospatialRepository gains a non-abstract planning_restrictions_for defaulting
to None (sources without the flags need not implement it); GeospatialS3Repository
reads conservation_status/is_listed_building/is_heritage_building from the same
Open-UPRN partition as the coordinates (legacy column names — to confirm in the
S3 deep-dive). Shared _row_for helper dedups the partition lookup.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`_cylinder_storage_loss_override` returned None for any cylinder whose
cylinder_insulation_type wasn't 1 (factory), so a loose-jacket cylinder
(code 2, RdSAP 10 field 7-11) fell to the cascade's zero-storage-loss
combi/instantaneous default — its real storage loss vanished. SAP 10.2
Table 2 Note 1 gives loose jacket a SEPARATE, ~2× higher loss factor
(L = 0.005 + 1.76/(t+12.8) vs factory 0.005 + 0.55/(t+4)); the
cylinder_storage_loss_factor_table_2 helper already implements it — only
the dispatch was missing.
Fix: a `_cylinder_storage_loss_insulation_label` resolver maps the lodged
code to the Table 2 branch (1 → factory_insulated, 2 → loose_jacket;
None/0/unknown → None, keeping the conservative no-loss default). The
override and the HW storage call now route through it instead of
hardcoding "factory_insulated".
Evidence + validation: a random 2026 register sample has 22 loose-jacket
certs that over-predicted SAP by +2.29 mean (18/22 too high, 1/22 within
0.5) — the exact signature of under-counted HW storage loss. After the
fix their mean error collapses to +0.45 and 11/22 land within 0.5, with
ZERO regression across the worksheet-validated cohort (§4 + golden suite
2394 passed — no validated cert lodges loose jacket, so none shifts).
Also unblocks the §10.7 A-F no-water-heating default (next slice) which
needs the loose-jacket branch. cert_to_inputs.py pyright unchanged at 32.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2e. recommend_solid_wall joins the orchestrator's fabric generator pool
(restrictions default unrestricted until slice 3 sources them); the harness
catalogue + contingencies (26%) gain external_wall_insulation /
internal_wall_insulation. run_modelling on an uninsulated solid-brick dwelling
(baseline SAP 36.6) now selects internal wall insulation into the optimised
package; the catalogue-completeness guard covers both new measure types.
Golden cohort 57/57 still error-free; IWI now fires on a real cohort cert.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2d. A flat can take IWI (its own unit) but not EWI (whole-block
coordination) — ADR-0019. _is_flat handles both ingestion representations:
the Elmhurst name form ('Flat') and the API stringified RdSAP code ('2' = Flat
per PROPERTY_TYPE_LOOKUP). Completes slice 2's eligibility surface.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2c. recommend_solid_wall takes a PlanningRestrictions value object
(defaults unrestricted): a conservation area removes the EWI Option (external
appearance), a listed or heritage building removes both EWI and IWI (protected
fabric) -> None when nothing survives (ADR-0019). Plus a guard that a cavity
wall yields no solid-wall Recommendation (it is handled by recommend_cavity
_wall). PlanningRestrictions will be sourced onto the Property from the
geospatial layer in slice 3 (ADR-0020).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated 001431 case (the cert that drove S0380.189/.190)
as an Elmhurst-only e2e fixture: Summary PDF → extractor → mapper →
calculator, every Block-1 SapResult field pinned against the
P960-0001-001431 worksheet at abs=1e-4. All 11 pins pass with zero
residual — the case is clean, confirming the S0380.190 gas-combi fuel
derivation closes the Summary path natively.
Verified the handover's flagged "+0.0007 SAP" was a target artifact, not
a cascade gap: the worksheet displays ECF (257) rounded to 1.6047 and
integer SAP (258)=78; the cascade's continuous SAP is computed from the
UNROUNDED ECF = (255)*(256)/((4)+45) = 660.9750*0.4200/173.0, giving
77.6147 — which matches the worksheet's own unrounded value. Pinning the
continuous SAP from the display-rounded ECF (→ 77.6144) was the wrong
target. Block-1 line refs all match exactly: (211) 10699.7225, (219)
3327.1592, (231) 86.0, (232) 283.2229, (255) 660.9750, (272) 3000.1664,
Σ(98) 8987.7669.
Summary mirrored into the tracked fixtures dir as
Summary_001431_gas_combi.pdf (distinct name — the corpus reuses cert
001431 across every heating variant); source Summary + worksheet tracked
under sap worksheets/golden fixture debugging/ as the pin ground truth.
2302 passed (+11), 0 failed; pyright net-zero on new/changed files.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>