The deal's third_party_surveyor_identifier is now required by the log
and amend flows: the trigger contract rejects messages without it
(blank treated as missing, since a blank resource makes OpenHousing
silently drop the appointment), and LogJobRequest/AmendJobRequest carry
it as a required field. The ABRI_RELAY_DEFAULT_RESOURCE fallback and
its config/terraform/workflow wiring are removed as dead code.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Carry third_party_surveyor_identifier on the Abri trigger message and
through dispatch into the log and amend flows, booking the job against
that resource. LogJobRequest gains the optional resource field
AmendJobRequest already had; the client falls back to the configured
default surveyor when the deal names no third-party resource, so
existing deals behave unchanged.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
* Electric-immersion DHW: bill at 100%, not the space boiler's efficiency 🟩
A separate electric immersion heater (SAP water-heating code 903) is 100%
efficient (SAP 10.2 Table 4a) and the space-heating boiler provides no water
heating, so Appendix D2.1 Eq D1 (the boiler seasonal-efficiency cascade) must
not apply to it. But `_water_heating_main` resolves DHW to the SPACE main — a
gas/oil boiler keeps its PCDB record — so three water-efficiency branches in
cert_to_inputs billed the immersion-heated cylinder at the boiler's ~87% summer
efficiency (a mongrel: electric fuel price x gas-boiler efficiency):
1. the scalar `water_eff = water_pcdb_main.summer_efficiency_pct / 100`,
2. the SAP §9.4.11 / Table 4c(2) -5pp no-interlock adjustment, and
3. the Eq D1 (winter, summer) seasonal pair from `pcdb_main`.
Gate all three on `not dhw_is_electric_immersion`; the correct immersion path
(`_water_efficiency_with_category_inherit` -> 1.0, Eq D1 off) then applies,
mirroring the Table 3 zero-primary-loss gate already present for WHC 903.
General bug — fires for any WHC-903 dwelling whose space main is a PCDB gas/oil
boiler. It surfaced via the PasHub campaign's #1600 no-water-heating default
(WHC 999 -> 903) on a gas-combi dwelling: 58 Hackle St M11 4WU, SAP 55.30 ->
57.67 (pre_sap 58, verified 59).
Guardrails: the gov-API RdSAP corpus IMPROVES 78.8% -> 78.9% within-0.5, MAE
0.625 -> 0.622 (a handful of corpus certs with a boiler space main + electric
immersion move closer to accredited) — MAE ceiling ratcheted 0.626 -> 0.625.
Regression pinned in test_cert_to_inputs (RED before / GREEN after). pyright
0-new (cert_to_inputs baseline 30).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
* PasHub SAP accuracy: thread low-energy lights + draught lobby (from_site_notes) 🟩
Two systematic silent-drops in the PAS Hub `from_site_notes` path, each a field
the gov-API/Elmhurst mappers thread but site-notes dropped, letting a favourable
default reach the SAP-10.2 calculator. Validated against the correct pashub
oracle (property_baseline_performance.effective_sap_score, portfolio 838):
cohort within-0.5 55.1% → 62.6%, MAE 0.599 → 0.521.
- Low-energy lights: when "exact LED/CFL known = No", PAS Hub lodges an aggregate
"Number of fixed low energy lights?" count. Previously dropped (no dataclass
field / extractor key / mapper thread) → calculator saw 0 low-energy bulbs and
applied the pessimistic L5b/L8c no-data default, under-rating SAP. Now threaded
into low_energy_fixed_lighting_bulbs_count, mirroring from_elmhurst_site_notes.
~6% of the cohort; resolves 58 Hackle (−0.43 vs oracle 59 with #1615).
- Draught lobby: _map_sap_ventilation set only the legacy `draught_lobby` field,
never the canonical `has_draught_lobby` §2 (13) gate the cascade reads, so the
surveyed lobby was ignored and infiltration over-stated. Now mirrors Elmhurst.
Two other audited levers were REJECTED against the pashub oracle (they matched
the gov-cert/RdSAP convention but pashub does not apply them): percent_draughtproofed
(cohort 30.8%) and the §A.2.2 assumed secondary heater (19.2%). A heat-network
control-code fix (2306→2303 for 16 Bingley) is HELD pending spec/Elmhurst
adjudication — it contradicts ADR-0053; see the NOTE on _PASHUB_HEAT_NETWORK_CONTROL_TO_SAP10.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
* PasHub heat-network control: room-thermostat-only maps to 2308, not 2306 🟩
The Table 4e Group 3 label "charging linked to use of community heating, room
thermostat only" was mapped to 2306 — the linked-to-use *with-TRVs* code
(control type 3, space charging 1.00). The label explicitly excludes TRVs, so
it is control type 2 / space 1.05 = code 2308/2309 (linked-to-use → DHW 1.00).
2306 asserted TRVs the survey doesn't have and over-rated the cohort's sole
heat-network dwelling (16 Bingley Close 56.89 → 54.01 vs pashub oracle 52).
Verified against SAP 10.2 Table 4e as encoded in cert_to_inputs.py
(_CONTROL_TYPE_BY_CODE 2308→2, space-charging 2308→1.05, DHW 2308→1.00) and the
RdSAP control-label vocabulary in MainheatControlAttributes.py. 2303 (the earlier
audit's guess) is rejected: it is a flat-rate code (DHW 1.05) whose oracle match
was a coincidence of two offsetting spec violations. The residual +2.0 to oracle
52 is the documented SAP-10.2-engine-vs-lodged offset, not a fuel/flags gap
(those were threaded by the #1590 follow-up) — supersedes the ADR-0053 /
HANDOVER_838 "community fuel/flags" attribution.
16 Bingley is the only heat-network fixture in portfolio 838, so this moves one
fixture strictly toward its oracle. Harness ratcheted: within-0.5 0.51→0.58,
MAE 0.625→0.521 (observed 58.5% / 0.520 with all three 2026-07-15 levers).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
* PasHub SAP accuracy: restore 3 dropped §2 infiltration inputs (from_site_notes)
`from_site_notes` uniquely dropped three ventilation inputs that the gov-API
and Elmhurst sibling mappers all set, causing a systematic cohort-wide SAP
under-rate vs the company's own accredited SAP-10.2 certs
(property_baseline_performance.effective_sap_score, portfolio 838):
1. percent_draughtproofed — never set, so §2(15) window infiltration was
pinned at its 0.25-ACH worst case on every dwelling. Reconstructed as the
area-weighted % of draught-proofed windows (mirrors Elmhurst
`draught_proofing_percent`). Dominant term.
2. Upper-storey +0.25 m joist void — omitted; now added, matching
`_UPPER_FLOOR_HEIGHT_ADD_M` on the gov-API/Elmhurst paths. This
RE-ADJUDICATES #1601 ("keep raw"): that call was confounded by the
then-present draught-proofing drop suppressing every verified dwelling.
3. sheltered_sides — left None → calculator's flat default of 2, which
over-shelters end/semi/detached (RdSAP §S5 = 1/1/0). Now derived from
built form.
The three are NON-ADDITIVE — each overshoots alone (which is why all three
were previously rejected individually) — but together they land all 7
verified ground-truth dwellings toward truth (none regress) and every built
form near zero. Cohort 62.1% -> 83.3% within-0.5, MAE 0.507 -> 0.377.
Guardrails: gov-API RdSAP corpus unchanged (78.9%, these are from_site_notes-
only helpers). pashub harness 58.5% -> 79.5% / MAE 0.520 -> 0.389; ratchets
tightened 0.58->0.78 and 0.521->0.40. pyright zero-new (mapper baseline 39).
New focused tests in TestFromSiteNotesInfiltrationFixes cover all three
fields incl. area-weighting and the built-form shelter map; goldens updated.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
---------
Co-authored-by: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Enumerates the 3 corpus certs that can move (all WHC 950) individually per
#1592 sub-task D: two improve (one crossing inside 0.5), one worsens and is
handed to sub-task C for an accredited oracle. No loosening required.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
pytest.approx is untyped under pyright strict, so the new assertions added
3 errors against the repo's zero-new-errors bar. Switches to the abs(...)
<= tol form already dominant in this file. No behaviour change.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
950 boilers / 951 CHP / 952 community heat pump differ only in plant
efficiency, which SAP 10.2 §4.3 puts in the Table 12 heat price — so the
dwelling's delivered-heat demand must not vary with it. Passes on the
previous commit's expression; verified RED against the prior impl, where
951 leaked 0.80/0.75 and 952 under-billed its DHW fuel by 3.15×.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
SAP 10.2 §4.3 (p.24) puts the water-heating efficiency in the Table 12
heat price, and C4 (p.53) scopes the plant efficiency to CO2/PE only, so
worksheet (310) = (64) × (305a) × (306) carries no efficiency term. The
dwelling-side divisor was applying it a second time.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Read stored lodged EPCs whatever refetch_epc says, so a stored assessment
can win the ADR-0001 Recency Tie-Break against the gov register.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
ADR-0054 gives a prediction conditioned by an expired Historic EPC the source
"expired", so reporting can tell "no EPC at all" apart from "only an expired
one". It was implemented in IngestionOrchestrator — but the pipeline that
actually runs is modelling_e2e, which predicts through its own _predict_epc and
never adopted it. Result: zero `expired` rows have ever been written, and
`epc_property.source` holds only 'lodged' and 'predicted'.
Two things kept the flavour unreachable here, and both had to go:
- _predict_epc never looked at the historic backup at all, so no prediction
was ever conditioned.
- _flush_writes passed the literal source="predicted", and _PropertyWrite had
no field to carry a flavour, so one would have been dropped before the write
even if computed.
_predict_epc now mirrors IngestionOrchestrator._predict: the expired cert's
stable attributes fill the gaps Landlord Overrides left (overrides still win
where both speak) and condition the cohort, and it returns the source alongside
the EPC. _PropertyWrite carries it; _flush_writes persists it. save_batch
already groups deletes by source family, so a mixed predicted/expired batch
clears the shared slot correctly.
Ships dark: the reader is built only when HISTORIC_EPC_S3_ROOT is set, so
without it every prediction stays plain "predicted", exactly as today.
DEFAULT_S3_ROOT names the dev bucket, so defaulting to it would have a prod
lambda silently reading dev data — Terraform sets the var per environment.
Note this also rescues properties that currently fail to model outright: an
expired cert can supply the property_type no override resolved, where today
that raises UnresolvedPropertyTypeError.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
inspection_date is non-null on epc_property, so it is a better winner for
a shared-UPRN collision than insertion order: the latest-surveyed lodged
row wins. id DESC stays as the deterministic secondary, so a same-UPRN,
same-inspection_date tie falls to the highest id.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
An epc_property row can carry a null property_id (FE/historic ingestion
persists EPC rows never linked to a property row), so a property_id-keyed
read silently misses them. UPRN is the durable key both the property row
and the epc_property row share. Repoint the lodged reads (get_for_property
+ get_for_properties) onto UPRN; the predicted reads stay on property_id
because a predicted EPC deep-copies a neighbour's UPRN, so its UPRN column
is never the property's own.
UPRN is not unique on epc_property, so the read tie-break is now load-
bearing (it was dormant under property_id, where the write path guarantees
one lodged row per property): the most recently ingested (highest-id) row
wins. Write path stays keyed on (property_id, source).
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Locks the gate edges — a lodged pitched loft below 270mm is recommended, a
loft at 270mm is left alone, and the 'Nmm+' form ('300mm+') parses to its
number and stays ineligible. These passed on arrival (they fell out of the
numeric-parse gate added in the previous commit); pinned as regression guards.
ADR-0063.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Properties 741843/741872 (uprns 100060714155/100021944594) failed
modelling_e2e subtasks 6ac7841a-9338-4efe-97e5-7e0d19b3055d and
c5450f03-5b0d-4068-a3b3-d1470bc0af57 with a bare StopIteration: their
SAP-Schema-15.0 (2011-era LIG-lodged) certs identify the main dwelling's
building part as "Main building" rather than "Main Dwelling", so
from_api_string fell to OTHER and left the property with no MAIN part —
crashing wall_recommendation.py's unguarded next(...).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Review findings on PR #1527:
- The overlay constants, ScoredOption builder, ventilation dependency and
selected_types helper come from the shared _optimiser_fixtures module
(landed on the fabric-first base) instead of local copies; the boiler
overlay is the shared BOILER_OVERLAY (SAP Table 4a code 104, a mains-gas
combi) rather than code 201, which is neither a boiler nor a heat pump.
_IWI_OVERLAY (solid-wall internal, type 3) stays local — no shared
equivalent — and the carbon stubs stay bespoke (the shared StubScorer has
no CO2 knob).
- The optimise_package_fabric_first import is lifted to module scope.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
An unrecognised schema_type used to raise ValueError and abort the whole
call; now from_api_response logs a warning and returns None so one
unmapped cert doesn't break a batch. Schema 15.0 already has a mapper
(PR #1531) so it's unaffected; only genuinely unmapped versions skip.
OpenHousing logs a job but silently drops the appointment when no bookable
resource is sent, so the survey date never lands. log_job already sends the
configured default_resource; amend_job omitted the parameter unless the
request carried an explicit surveyor. Default amend's resource to the
configured surveyor too, and fail loudly at config load on a blank
ABRI_RELAY_DEFAULT_RESOURCE so the misconfiguration can't ship an empty
resource again.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Review findings on PR #1526:
- tests/domain/modelling/_optimiser_fixtures.py is the one home for the
overlay constants, the ScoredOption builder, the additive per-kind
StubScorer and the forced ventilation dependency; test_optimiser.py and
test_optimiser_fabric_first.py had byte-identical copies of each
(and _StubScorer / _VentStubScorer fold into one parameterised stub).
- Fixture worlds are domain-plausible per team convention: the fabric-vs-
heating contrast is a £12,000 EWI against a £3,200 gas boiler rather
than a £500 heat pump undercutting a £1,000 cavity wall; heating
overlays carry real identities (SAP Table 4a code 104 for the boiler,
a PCDF index for the heat pump) instead of code 201 doubling as both;
whole-dwelling double glazing is £3,500, not £500.
- Dead knobs removed: the unused _ROOF_OVERLAY, the always-zero roof
gain, the duplicate _BOILER_OVERLAY, and the nested conditional
expressions in the interaction stubs.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Re-attempted entering this SAP-15.0 cert's 4 real N/E/S/W windows (gov-API
sap_windows, 2.516 m^2 each) as separate Elmhurst Openings rows instead of
the accepted single combined South row, to test whether it closes the
residual ~2pt gap (engine 53 vs Elmhurst worksheet 51).
Reproduced live the documented elmhurst_lib.py window-grid limitation:
adding a 2nd row wipes the previously-added row's width/height to 0.00,
in both same-session and fresh-session-per-window attempts. Not fixable
via current Playwright automation. Restored the assessment to its original
single South 10.06 m^2 row (no PDFs re-downloaded, no worksheet change).
Separately confirmed our own engine already models this cert's windows
per-orientation correctly from gov-API sap_windows via
solar_gains.py's ORIENTATION_BY_SAP10_CODE cascade -- this is an Elmhurst
build-tooling ceiling, not an engine or mapper bug. sap_score=53 remains
unchanged; no calculator/mapper code was touched. Full accuracy suite
re-run clean (66 passed/67 skipped/1 xfailed + corpus test passed).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Both flagged mismatches were Elmhurst input errors (same silent-stale-value
contamination class as the earlier chimneys/wall-thickness bugs), not
parser or calculator bugs:
- cylinder_size: build_100010086084.py's water_heating() selected
DropDownListCylinderSize by raw value "2", but this DOM's option values
ARE their visible litre-band text (no "2" among them) — Playwright
silently no-ops on a non-matching value, leaving a prior cert's "Medium
(131-170L)" selection in place. Fixed to match by text ("Normal"), and
added the missing mapper dict entries (Normal/Large litre-suffixed
labels) to _ELMHURST_CYLINDER_SIZE_LABEL_TO_SAP10 (a real mapper-coverage
gap — the calculator raises UnmappedElmhurstLabel rather than silently
mis-mapping).
- boiler_flue_type: the boiler-code search dialog's combined "Balanced/Open
Flue" Table 4b category doesn't drive the separate, independently
selectable RadioButtonListFlueType field, which was left at an inherited
"Balanced" from a prior cert. Fixed space_heating() to explicitly select
"Open" to match the lodged gov-API code. This field isn't consumed by
Sap10Calculator (ML/generator-only), so it had zero effect on the SAP
score.
Re-downloaded elmhurst_summary.pdf/elmhurst_worksheet.pdf after the fixes
(Recommendations page confirmed clean). Elmhurst-PDF-inputs path moved
46->47 SAP from the cylinder-volume correction; gov-API SAP (53) and
Elmhurst's own worksheet (51) are unchanged. Full accuracy suites re-run
clean (67 passed, 67 skipped, 1 xfailed, same as before).
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
The Elmhurst rebuild for this cert had two carryover bugs from the shared
Playwright session: TextBoxOpenChimneys silently inherited "2" from a prior
cert's build (this cert's register lodges open_fireplaces_count=0, which
the gov-API mapper already reads correctly), and wall thickness inherited
a stale 280mm. Also fixed a real bug in the space_heating() PCDB-ref-clearing
logic: input_value() returns the string "0" when already cleared, which is
truthy in Python, causing a spurious navigate-away that broke the next
E.goto() call.
Rebuilt cleanly (chimneys=0, wall thickness=220mm per RdSAP convention for
unrecorded solid-wall thickness, since CheckBoxWallThicknessUnknown does not
persist via Playwright in this tool version). Elmhurst's own worksheet score
moves from a contaminated 46/48 to 51, closing the gap against this engine's
53-on-gov-API-inputs from ~5-7pt to ~2pt. No mapper.py change was needed --
the gov-API mapper's open_chimneys_count=0 was correct all along.
Co-Authored-By: Claude Sonnet 5 <noreply@anthropic.com>
Built UPRN 100010086084 (the largest gov-API-vs-lodged outlier from the
20-cert batch) in Elmhurst's accredited RdSAP10 tool to get real ground
truth, per feedback that lodged rating isn't a valid comparison target.
Elmhurst worksheet: SAP 46-48 (orientation-dependent), vs this engine's
53 on gov-API inputs -- a real ~5-7pt residual gap. Ruled out with
direct empirical tests: total_floor_area, missing party_wall_length,
region/climate (SAP rating always uses UK-average weather per Appendix
U -- confirmed inert), boiler/secondary efficiency (exact match, 66%/
63% both sides). Confirmed real but NOT blind-fixed (need more than one
cert's evidence, and a wall-U-value patch tested the wrong direction in
isolation): a wall-thickness-unknown U-value fallback mismatch (this
engine 1.70, Elmhurst's own "unknown" resolution 1.40) and a window
U-value divergence (1.85 vs 2.52 W/m2K for the same nominal glazing
pick). Single-window orientation confirmed a ~2pt partial contributor.
Also fixes a small, separate, evidenced gap the build surfaced: the
Elmhurst summary parser didn't recognise the live tool's "Medium
(131-170L)" cylinder-size label (only the bare "Medium").
Full write-up is in the RealCertExpectation comment for this cert in
test_real_cert_sap_accuracy.py and the worklist. Residual gap is
intentionally left open for follow-up, not force-closed.