Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.
The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:
- Target is always a gas condensing boiler, not fuel-preserving: every after
lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
mains-gas connection; electric boilers are left alone (electrification is the
upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
+ cylinder). The calculator derives the condensing seasonal efficiency from
the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
`fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
cylinder is below 80 mm (never downgrading a better one). Both are conditional
per-dwelling components, not a frozen overlay.
Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.
Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 7 of the Solar PV Recommendation Generator (ADR-0026). Adds the
composite per-dwelling Solar PV cost on the Products collection (ADR-0025
pattern): pv_system(kWp band, nearest of the ECOPV06-13 EA bands 1.0→4.5 kWp,
floor/cap at the ends) + scaffolding(£900 first elevation + £450 each
additional, default 2) + enabling base (EICR £150 + DNO £50 + 2-way consumer
unit £330) + [diverter £980 if cylinder] + [battery if the with-battery
variant] → Cost(total, contingency_rate 0.15).
Rates are data in the committed solar_rates.json (Southern Housing "SOLAR PV &
BATTERY" EA column), loaded via SolarRates.from_json/.default and injectable.
The £2,000 / 5 kWh battery is NOT on the rate sheet — a flagged estimate
(battery_estimate=true), confirmed with the user to stand in until a DB rate.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_heating now receives planning_restrictions in the orchestrator (the
ASHP planning gate); the ASHP bundle joins the free candidate pool for every
house/bungalow. Catalogue + contingency (legacy 0.25) gain air_source_heat_pump;
report.py _triggers_for explains the ASHP trigger; the harness forcing test
covers it. Integration tests seed an air_source_heat_pump MaterialRow (ASHP
fires on every house, the broadest trigger yet). NB the optimiser correctly does
NOT select ASHP for an EPC-band goal — gas->electric does not improve the SAP
cost-rating; ASHP is a CO2/PE measure, selectable once non-EPC goals land. ASHP
bundle COMPLETE (S5-S7). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_heating joins the free candidate pool in _candidate_recommendations;
the HHR storage bundle reaches the optimised package for an electric/off-gas
dwelling. Catalogue + contingency (legacy 0.10) gain
high_heat_retention_storage_heaters; report.py _triggers_for explains the
heating trigger (electric/off-gas main); the harness _GENERATOR_MEASURE_TYPES
forcing test covers it. ASHP + boiler bundles still to come. ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the lighting generator (ADR-0023): run recommend_lighting in
_candidate_recommendations (no planning gate). Price low_energy_lighting in the
offline catalogue + contingency table (0.26, the legacy rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both. A run_modelling test pins
the wiring end-to-end (an incandescent-lit dwelling gets the LED upgrade in the
optimised package).
Downstream updates, all because lighting now fires on any cert with non-LED
bulbs: report.py gains the low_energy_lighting trigger (the non-LED counts); the
two golden-cert report tests and the multi-measure integration test now expect
low_energy_lighting alongside the fabric measures (the sample/golden EPCs lodge
low-energy-unknown bulbs); first-run integration seeds a low_energy_lighting
MaterialRow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the glazing generator (ADR-0022): run recommend_glazing in
_candidate_recommendations, threading the Property's PlanningRestrictions so a
protected dwelling is offered secondary glazing instead of double (mirrors
recommend_solid_wall). Price both Measure Types in the offline catalogue
(double £600/window, secondary £510 -- the legacy 0.85x scaling) and the
contingency table (0.15, the legacy windows_glazing rate); the
_GENERATOR_MEASURE_TYPES forcing test enforces both entries exist.
run_modelling tests pin the wiring end-to-end on an all-single-glazed dwelling:
double when unrestricted, secondary when listed. The first-run integration test
seeds a double_glazing Product because its lodged EPC has a single-glazed
window. _single_glazed_epc() deep-copies build_epc() (which shares its window
objects) so the mutation can't leak into other tests' baselines.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 (ADR-0021). The roof dispatcher can now emit sloping_ceiling_insulation
and flat_roof_insulation, so wire both into contingencies and the sample
catalogue; the forcing-function test now asserts every generator measure type
is both priced and has a contingency rate, so an offline/live run over a
sloping or flat roof never dies on a missing entry.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2e. recommend_solid_wall joins the orchestrator's fabric generator pool
(restrictions default unrestricted until slice 3 sources them); the harness
catalogue + contingencies (26%) gain external_wall_insulation /
internal_wall_insulation. run_modelling on an uninsulated solid-brick dwelling
(baseline SAP 36.6) now selects internal wall insulation into the optimised
package; the catalogue-completeness guard covers both new measure types.
Golden cohort 57/57 still error-free; IWI now fires on a real cohort cert.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ModellingOrchestrator builds the ventilation dependency per Property
(suppressed when already mechanically ventilated) and passes it to
optimise_package, so a selected wall measure forces MEV into the package before
the re-score. Ventilation joins the role-3 cascade in best-practice order
(walls -> roof -> ventilation -> floor) and persists as a Plan Measure carrying
its real negative marginal and its cost. Added the mechanical_ventilation
contingency rate (0.26, per legacy Costs.CONTINGENCIES). Integration test now
seeds the ventilation Product and asserts the forced measure persists with
<=0 SAP and 2x900 cost; the full-pipeline test seeds the Product too (the
dependency is built for every not-yet-ventilated dwelling). On 000490 the real
calculator scores MEV at -1.275 SAP.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_floor_insulation(epc, products) detects an uninsulated ground floor
(SapBuildingPart.floor_insulation_thickness blank/zero) and its construction
from floor_construction_type — 'Suspended timber' -> suspended_floor_insulation,
'Solid' -> solid_floor_insulation — emitting the matching single Option (a
floor is one construction, like a cavity wall) with the overlay
(floor_insulation_thickness = 100 mm) and a priced Cost (ground-floor area x
the Product's fully-loaded unit cost + contingency).
- building_geometry.ground_floor_area(epc, identifier): the lowest floor's
(floor == 0) area. Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains floor_insulation_thickness (generic Applicator
writes it unchanged). suspended (0.20) / solid (0.26) floor contingencies.
Progress on #1159 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and parser. Four behaviour tests (suspended / solid
/ none / cost) + geometry pin. pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_loft_insulation(epc, products) detects an uninsulated main loft
(SapBuildingPart.roof_insulation_thickness == 0) and emits a
Recommendation("Roof") with one loft_insulation Option carrying the overlay
(roof_insulation_thickness = 270 mm, the recommended top-up) and a priced
Cost (roof area x the Product's fully-loaded unit cost + contingency).
- building_geometry.roof_area(epc, identifier): the part's greatest
per-storey floor area (RdSAP 10 §3.8). Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains roof_insulation_thickness; the generic Overlay
Applicator writes it with NO change (validated by the tracer) — the
deep-module field-fold paying off.
- loft_insulation contingency (0.10) added.
Progress on #1158 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and the parser fix. Four behaviour tests
(geometry pin; detect / none / cost). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Product(measure_type, unit_cost_per_m2, contingency_rate). ProductRepository
is the DDD port abstracting the catalogue source; ProductPostgresRepository
reads the externally-owned material table (defensive SQLModel view
MaterialRow) and maps an active row to a Product — total_cost becomes the
fully-loaded unit_cost_per_m2 — joining the per-measure-type contingency
(contingencies.py, mirrors Costs.CONTINGENCIES; cavity 0.10). Strict-raise
on missing/inactive row. A JSON-backed impl will follow behind the same
port for ETL-gap costs.
Two DB tests against an ephemeral Postgres (map active row; raise on
inactive-only). Toward #1155 cost (4b). Also generalises the CONTEXT
Simulation Overlay wording: windows are targeted by index, building-part
association carried via window_location (_window_bp_index). pyright clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>