Pin the coal-boiler-with-cylinder upgrade and add the `boiler_flue_type`
end-state field. A solid-fuel (coal) boiler (fuel 11, SAP code 153) on a
mains-gas street converts to a gas condensing boiler (fuel 11->26, code 102) —
the non-gas->gas path for a solid-fuel system, eligible because code 153 is in
the wet-boiler solid-fuel range 151-161 and mains gas is present.
New `boiler_flue_type` HeatingOverlay field, routed to main_heating_details[0]
and set to 2 (room-sealed/balanced) on both boiler shapes: every relodged after
lodges flue type 2, but coal's before lodged none. The field is SAP-inert (the
cascade score is unchanged by it), so it is written purely for end-state
fidelity — the overlay now represents the installed condensing boiler's flue.
Validated via the overlay-equality unit tests.
The coal after predates the user-locked "always add a cylinder thermostat when
absent" rule, so it stale-lodged thermostat 'N'; the pin corrects it to the
rule's end-state 'Y' in-test (the gas with-cylinder after got the same
correction by re-lodging). The cylinder is already 80 mm insulated, so the
jacket is skipped and only the thermostat is added; controls (2106) are
unchanged. Cascade-pinned delta 0 (SAP/CO2/PE).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Two more boiler-upgrade cascade pins, validating the existing generator across
fuels and cylinder states (no source change):
- oil combi: an oil boiler (fuel 28, code 130) on a mains-gas street converts to
a gas condensing combi (fuel 28->26, code 104). Proves the non-gas -> gas
conversion gated on a mains-gas connection (ADR-0024 revised).
- already-insulated cylinder: a gas boiler heating a pre-jacketed cylinder
(type 2 / 80 mm, no thermostat) gets a new boiler + a thermostat, with the
jacket NOT re-applied. Proves the cylinder path's skip-jacket branch against a
real cert. (Sourced from an LPG re-lodgement whose fuel the Summary mapper
reads as mains gas 26 — a separate LPG fuel-mapping gap, noted in the test.)
Both pin delta 0 (SAP/CO2/PE) against the relodged after.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Extend the gas-boiler-upgrade Option to combi (no-cylinder) dwellings and add
the controls upgrade shared by both boiler shapes. A dwelling has a cylinder or
it does not, so the one `gas_boiler_upgrade` Option is shaped per dwelling:
- no cylinder -> a gas condensing combi (Table 4b code 104), no cylinder fields
touched;
- a cylinder -> a regular boiler (code 102) heating it, with the conditional
cylinder jacket/thermostat (slice 1).
Controls: bring an inadequate boiler control up to full programmer + room
thermostat + TRVs (SAP 10.2 Table 4e Group 1 code 2106). "Inadequate" = the
Group-1 codes with NO room thermostat (2101, 2102, 2107, 2108, 2109, 2111) —
these lack boiler interlock (Table 4c(2) / footnote c) p.171), so adding a room
thermostat genuinely improves SAP. Room-thermostatted (2103/2104/2105/2106/2113)
or better zone controls (2110/2112) are left unchanged — never downgraded, so
no phantom uplift. The with-cylinder cert (control 2106) is therefore untouched
and its pin still holds at delta 0.
Validated by the combi before/after re-lodgement (cert 001431, gas boiler
upgrade - no cylinder): control 2111 "TRVs and bypass" -> 2106, fan flue
False->True, SAP code 112 -> 104. Cascade-pinned delta 0 (SAP/CO2/PE). Removed
the slice-1 placeholder test asserting no boiler Option fires without a cylinder
(the combi Option now correctly fires there).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add the first boiler-upgrade option to the single "Heating & Hot Water"
Recommendation (ADR-0024 expansion): a dwelling whose existing wet boiler heats
a hot-water cylinder is offered a new gas condensing boiler, with the cylinder
jacketed when under-insulated and given a thermostat when absent. One competing
Option (the Optimiser picks <=1), folded into one composite Plan line.
The end-state is read from the Elmhurst before/after re-lodgements (cert 001431,
gas boiler upgrade - with cylinder), which REVISE ADR-0024:
- Target is always a gas condensing boiler, not fuel-preserving: every after
lodges fuel 26. Gas->gas always; a non-gas wet boiler ->gas only with a
mains-gas connection; electric boilers are left alone (electrification is the
upgrade path). Eligibility = wet-boiler SAP code (Table 4a/4b 101-141 /
151-161 / 191-196) + not an electric boiler + mains gas present.
- End-state is a Table 4b SAP code, not a PCDB index: code 102 (regular boiler
+ cylinder). The calculator derives the condensing seasonal efficiency from
the code, so no efficiency input exists or is needed.
- A modern condensing boiler has a fanned flue: the after flips
`fan_flue_present` False->True on every cert (SAP 10.2 Table 4f flue-fan +
the Table 4b condensing-efficiency basis). Added as a new HeatingOverlay
field, routed to main_heating_details[0].
- Cylinder thermostat is always added when absent (user-locked); the jacket is
the 80 mm `cylinder_insulation_type=2` end-state, applied only when the
cylinder is below 80 mm (never downgrading a better one). Both are conditional
per-dwelling components, not a frozen overlay.
Cascade-pinned delta-0 (SAP/CO2/PE) against the relodged after via
`_assert_overlay_reproduces_after`. NB the absolute SAP on this dwelling is
subject to a separate Summary-path mapper roof-fidelity gap (we read the roof
better-insulated than Elmhurst, scoring ~75 vs the printed 56); the gap is
identical on before+after (the boiler measure never touches the roof) so it
cancels and the pin still proves the exact heating field-delta. Tracked on the
calculator branch.
Wires the new `gas_boiler_upgrade` MeasureType through contingencies (0.26),
the offline sample catalogue, the catalogue-coverage list, and the ARA
first-run integration seed (the option fires on any mains-gas boiler+cylinder
dwelling).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Add domain/modelling/considered_measures.py::restrict_to_considered_measures —
the pure allowlist that limits a run to a chosen set of MeasureType (mirroring
the legacy engine's `inclusions`). It filters at the Option level, so a
multi-option Recommendation (e.g. Heating & Hot Water competing HHRSH against
an ASHP bundle) is kept with only its allowed Options; a Recommendation left
with none is dropped. None = consider everything (unrestricted default).
Thread `considered_measures: frozenset[MeasureType] | None` through
ModellingOrchestrator.run -> _plan_for -> _scored_candidate_groups /
_candidate_recommendations (applies the filter) and _measure_dependencies
(suppresses a forced dependency whose required measure is outside the
allowlist, so a restricted run forces nothing it is not considering). The
local-run seam (harness.console.run_modelling) gains the same param.
The Optimiser still freely chooses among survivors — including none. Tests:
the pure filter (3 cases) + an orchestrator-seam test proving a
{solar_pv}-restricted run yields only solar_pv options. 257 pass + 3 xfail;
pyright clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Tighten the recommendation/plan vocabulary off generic str:
MeasureOption.measure_type and PlanMeasure.measure_type are now MeasureType
(also _GlazingTarget.measure_type, MeasureDependency.triggers ->
frozenset[MeasureType], and the optimiser's chosen/required-type locals).
Because MeasureType is a StrEnum the change is transparent to persistence
(the `recommendation` varchar column), the optimiser group-by key, and every
`== "solar_pv"`-style comparison — so pyright now enforces the enum at every
construction site with no runtime behaviour change.
The catalogue boundary stays str: ProductRepository.get(measure_type: str)
and Product.measure_type are unchanged (they map arbitrary DB/JSON rows), so
the fake product repos in tests need no edit. Test construction helpers coerce
their str arg via MeasureType(...); direct constructions use members.
Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on production + tests (pre-existing moto + property-
override-rowcount baselines untouched).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Introduce domain/modelling/measure_type.py — a StrEnum with one member per
modelled measure (the 15 the generators emit). A StrEnum so each member *is*
its string value: it persists straight into the `recommendation` varchar
column, is the optimiser's group-by key, and compares equal to the catalogue /
EPC strings — so it replaces the per-generator string constants with no
persistence or optimiser change.
Repoint every generator's measure-type constant/literal to a MeasureType
member (wall, solid_wall, roof, floor, glazing, lighting, ventilation,
heating, solar). Field annotations stay `str` for now; tightening them to
MeasureType is the next slice.
This is the enum the historical engine deferred (engine.py:970
"TODO - formalise property measure types into an enum") and the vocabulary the
forthcoming `considered_measures` allowlist will speak (mirroring the legacy
`inclusions`).
Suite green: tests/domain/modelling + orchestration + harness 253 pass + 3
xfail; pyright clean on the enum + generators.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pulls in 42 commits of calculator/mapper accuracy fixes from the per-cert
mapper-validation and floor/roof/heating fronts.
Conflict resolutions:
- mapper `_is_elmhurst_roof_window`: main dropped the branch's "wall location →
vertical" guard (it broke cert 000516's rooflight), but that re-broke cert
001431's two External-wall U>3.0 windows (which must stay vertical). The two
certs lodge a BYTE-IDENTICAL §11 row, so neither location nor U separates
them — the real discriminator is the room-in-roof context. Replaced the
unconditional U>3.0 backstop with one gated on the BP having a room-in-roof
(`_elmhurst_bp_has_room_in_roof`): 000516's Main BP has a "Room in roof type
1" (→ rooflight), 001431's does not (→ vertical). Validated against BOTH —
full Elmhurst worksheet suite 1038 pass + the 001431 window-extraction pin.
- property_postgres_repository: kept main's `ids_by_uprn` method + the branch's
`_restrictions_of` helper.
- sap_fuel.py: the branch relocated it to domain/billing/ (already carrying
main's to_table_32_code normalization), so kept the old path deleted.
Fallout from main's fabric fixes (validated by the boiler-3 real-cert pin which
still reproduces at delta 0):
- re-pinned the boiler-1 + boiler-instant-hw ASHP snapshot scores;
- main's §14.2 gas-boiler main-fuel derivation resolved the BGB/102 baseline
gap, so `test_gas_boiler_instant_hw_before_baselines` is now a passing test
(was an xfail tripwire).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 9 of the Solar PV Recommendation Generator (ADR-0026). Pins the
overlay→calculator PV cascade against Elmhurst's before/after re-lodgements of
cert 001431, across the orientation/pitch/overshading config space (the certs
lodge synthetic 1.00 kWp test vectors):
- SE/SW, shaded (overshading 3/2), pitch 30°/45°
- E/W, unshaded, pitch 60°/45°
- NW/N, unshaded, pitch 60°/45° (the low-yield orientations)
Each hand-built SolarOverlay reproduces the relodged after at abs ≤ 1e-4 on
SAP / CO2 / primary energy.
Battery tripwire (per user): the "with battery" cert lodges a §19 5 kWh battery
the current extractor does NOT parse, so it scores identically to its
no-battery twin — the no-battery overlay reproduces it today, and the pin will
fail (alerting us to switch to the with-battery overlay) once the extractor
parses the battery. A companion test pins that the calculator already models
the 5 kWh battery (it raises SAP), so the fix target is established.
All five certs share an EES 'WGK' / SAP-code-502 main-heating lodgement the
mapper doesn't yet derive a fuel for; the pins patch the shared fuel (mains gas
26) identically on before+after to isolate the PV delta (the solar overlay
never touches heating), and `test_solar_before_baselines` xfails as the
forcing-function tripwire for that separate mapper-front gap.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 6 of the Solar PV Recommendation Generator (ADR-0026). `recommend_solar`
emits one "Solar PV" Recommendation of up to five conservatively-sized configs
× {no battery, battery} = ≤10 competing Options (a free Optimiser candidate).
Each Option folds a SolarOverlay built from the chosen config: one
PhotovoltaicArray per non-north segment (peak_power = panels × panelCapacityW /
1000; orientation/pitch from geometry; generation-calibrated overshading),
is_dwelling_export_capable set True absolutely, a diverter when the dwelling
has a cylinder (None for a combi), a 5 kWh battery for the battery variant, and
the per-config composite cost from Products.solar_bundle_cost.
Eligibility = house/bungalow ∧ not listed/heritage (blocks_internal, the same
gate as ASHP — a conservation area does NOT block PV) ∧ no existing PV ∧ a
feasible SolarPotential. Flats and existing-PV top-up are deferred.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 7 of the Solar PV Recommendation Generator (ADR-0026). Adds the
composite per-dwelling Solar PV cost on the Products collection (ADR-0025
pattern): pv_system(kWp band, nearest of the ECOPV06-13 EA bands 1.0→4.5 kWp,
floor/cap at the ends) + scaffolding(£900 first elevation + £450 each
additional, default 2) + enabling base (EICR £150 + DNO £50 + 2-way consumer
unit £330) + [diverter £980 if cylinder] + [battery if the with-battery
variant] → Cost(total, contingency_rate 0.15).
Rates are data in the committed solar_rates.json (Southern Housing "SOLAR PV &
BATTERY" EA column), loaded via SolarRates.from_json/.default and injectable.
The £2,000 / 5 kWh battery is NOT on the rate sheet — a flagged estimate
(battery_estimate=true), confirmed with the user to stand in until a DB rate.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 5 of the Solar PV Recommendation Generator (ADR-0026). Adds the flat
`SolarOverlay` and `_fold_solar`, the sixth Simulation Overlay surface: like
the ventilation/lighting overlays it targets no building part and folds its
fields onto `sap_energy_source` (home of the SAP Appendix M PV inputs) —
photovoltaic_arrays (absolute target, one PhotovoltaicArray per non-north
segment, replacing the dwelling's existing arrays), pv_diverter_present,
pv_connection, is_dwelling_export_capable (set True absolutely), pv_batteries.
Omitted fields leave the baseline unchanged (combi → no diverter); the
baseline is never mutated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of the Solar PV Recommendation Generator (ADR-0026).
`select_conservative_configs` turns Google's full solarPanelConfigs ladder
into up to five competing array configs for the Optimiser: drop north-facing
planes (within 30° of due north, wrap-aware), cap usable panels at ~70% of
maxArrayPanelsCount (imagery misses obstructions; MCS edge setback), collapse
rungs that trim to the same usable size keeping the higher-generation layout,
then sample five spanning min→max by expected generation. Returns () when
nothing usable remains.
Real London example → 5 rungs at 4/12/19/26/34 panels (all ≤34.3 = 70% of
49); synthetic cases pin the north-drop and the 70% cap.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the Solar PV Recommendation Generator (ADR-0026). Per roof segment,
back-solve the effective overshading factor ZPV from Google's expected
generation against SAP's own unshaded annual output:
ZPV = (yearlyEnergyDcKwh × 0.955) / (0.8 × kWp × S)
reusing the calculator's Appendix U3.3 annual solar radiation S via a new
public seam `pv_annual_solar_radiation_kwh_per_m2`. Dividing Google's
generation by SAP's S cancels orientation/tilt and isolates shading; the
result snaps to the RdSAP bucket {1:1.0, 2:0.8, 3:0.5, 4:0.35} via the
ADR-0026 midpoint cutpoints (≥0.90→1, 0.65–0.90→2, 0.425–0.65→3, <0.425→4;
ZPV>1→1). The real London example's planes all back-solve to ZPV>1 → code 1.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of the Solar PV Recommendation Generator (ADR-0026). Adds the
strictly-typed `SolarPotential` domain projection over the raw Google Solar
`buildingInsights` JSON that Ingestion persists (SolarRepository): the
`solarPanelConfigs` ladder, each rung broken into its roof segments with
Google's continuous azimuth/tilt mapped to the SAP octant
(`azimuth_to_sap_octant`, 0°=N clockwise → 1=N..8=NW, matching the
calculator's ORIENTATION_BY_SAP10_CODE) and RdSAP §11.1 pitch code
(`pitch_to_sap_code`, snap to {0→1,30→2,45→3,60→4,90→5}).
Pinned against the real London buildingInsights example (mirrored into
fixtures from the user-provided RTF): 400 W panels, maxArrayPanelsCount 49,
46-rung ladder, per-segment SE/NW/NE/SW octants at ~32° → pitch code 2.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The boiler-1 and boiler-2 after-certs predate the Vaillant product swap (they
lodge the old aroTHERM index 101413), so rather than wait on regenerated certs
these now snapshot the Vaillant overlay's own output on the before (SAP/CO2/PE
at 1e-4), taken as correct because the same overlay reproduces the corrected
Vaillant cert at delta 0 in the boiler-3 (system-boiler) pin. Drops the xfail
markers and the two stale, now-unreferenced after-cert fixtures.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 10 of ADR-0025 costing. The Southern Housing rate table moves from code
constants into ashp_rates.json (structured rows the flat scalar catalogue can't
hold), loaded via AshpRates.from_json. Products takes an injected AshpRates
(default: the committed sheet), so rates are now data -- tunable (e.g.
reuse_distribution_fraction) without a code change, and ready for ETL/DB-supplied
rates later. Behaviour-preserving: the 6 pinned cost tests still hold against the
default, plus a new test proving injected rates drive the total.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The representative heat pump is now the Vaillant aroTHERM plus 5 kW (index
110257, committed with the generator). boiler-3's after-cert is re-sourced from
the corrected Vaillant relodgement and its cascade pin passes at delta 0
(SAP 63.85 -> 72.30). boiler-1 and boiler-2(instant-HW) pins are xfail pending
their own corrected Vaillant after-certs (_ASHP_PRODUCT_REPIN_REASON).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 9 of ADR-0025 costing. _ashp_option now prices via Products.ashp_bundle_
cost(ashp_cost_inputs(epc)) instead of the flat catalogue scalar; the catalogue
row is still read for its material_id. Pinned on boiler-3: gas reuse dwelling
composes to 15600.60 (decommission 720 + pump 9720 + cylinder 2382.60 + reuse
distribution 2778) with 25% contingency.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 8 of ADR-0025 costing. _existing_system keys on the heating fuel code,
not the mains_gas flag -- the 001431 electric fixtures all lodge mains_gas=True
(gas available at the property) while heating electrically (fuel 30), which the
flag-based check misread as gas (and would have wrongly reused a non-existent
wet system). Electric/gas/oil/LPG map to their categories; empty details ->
NONE; unrecognised -> OTHER (gas-line fallback).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 7 of ADR-0025 costing: the modelling-layer interpretation half of the
split. ashp_cost_inputs derives existing system (mains_gas/fuel/SAP-code),
size band (floor area <= 75 m2), design heat loss (floor_area x 0.05 -- the
chosen proxy over HLC, ADR updated), radiator count (habitable + 3, floor-area
fallback) and reusable-wet-system flag. Catalogue math (Products) stays
EPC-free. ADR-0025 updated to record the floor-area pump-sizing choice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 6 of ADR-0025 costing. Characterises the distribution clamp built in the
tracer: a radiator proxy below 4 prices as the 4-rad band, above 12 as the
12-rad band, in-range exact.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 5 of ADR-0025 costing. Characterises the pump-band selection built in
the tracer: a design heat loss is rounded UP to the smallest covering band
{5,8,11,15,16+} kW, and loads above the largest band take the top rate. Edge
pins (5.0/5.01/8.0/8.01/11.0/15.0/15.01/25.0) lock the boundaries.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 4 of ADR-0025 costing. ASHP is offered to any house regardless of fuel,
so _decommission now prices a fallback instead of raising: no system -> 0,
electric room/panel heaters -> electric-storage line, anything else -> gas
line (representative default). Never blocks ASHP eligibility.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of ADR-0025 costing. When the dwelling has a reusable wet system,
_distribution charges a power-flush (168) plus _REUSE_DISTRIBUTION_FRACTION
(0.5) of the full radiator band -- a documented stand-in for partial radiator
upsizing at ASHP flow temps, the headline uncertainty in the model. Without a
wet system the full new distribution is priced.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of ADR-0025 costing. _decommission maps the existing system to its
Southern Housing line: gas/oil flat 720, LPG 960 (tank+fuel removal),
electric-storage 570/840 by property-size band. Unmapped systems raise for
now -- the no-system/electric-other/other fallbacks land in the next slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
First slice of the per-dwelling ASHP bundle costing (ADR-0025). Products is
the rich catalogue collection over Product, owning the catalogue math: given
a typed AshpCostInputs it sums the applicable Southern Housing rate lines
(decommission + heat-pump band + fixed cylinder + full wet distribution) into
a Cost with the separate 25% ASHP contingency. Pure -- no EpcPropertyData or
calculator. Pinned exact (1e-9) against the real rate sheet. Reuse branch,
decommission variants, fallbacks, band edges and radiator clamp follow.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pins the cylinder-OVERWRITE path the earlier ASHP pins did not exercise:
boiler-1/boiler-2 added a cylinder where none existed, whereas boiler-3's
before is a mains-gas regular boiler (SAP code 101) that already heats its
own cylinder (size 2 / insulation type 2 / 80 mm). The fixed _ASHP_OVERLAY
overwrites it to the heat-pump cylinder (size 4 / insulation type 1 / 50 mm)
and switches the dwelling off mains gas (fuel 26->30, code 101->index 101413
+ category 4). The existing overlay reproduces the re-lodged after at delta 0
on SAP / CO2 / primary energy -- no overlay change needed; immersion_heating_
type is None in both, so that field (the electric-with-cylinder case) is
untouched here.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Second ASHP before/after (boiler 2): a gas boiler whose hot water is electric/
instantaneous (water-heating SAP code 909, no cylinder). The cascade pin passes
at 1e-4, exercising the overlay's water_heating_code reset 909 -> 901 that the
boiler-1 pin (already 901) did not. (After lodges control 2209 vs the overlay's
2210 — SAP-equivalent zone controls.)
Adds an xfail(strict) tripwire test_gas_boiler_instant_hw_before_baselines: the
raw before is not scorable on its own because the mapper maps the 'BGB' gas-
boiler EES code to an empty main_fuel_type (boiler-1's 'RGE' resolves to 26),
so Sap10Calculator raises MissingMainFuelType. Harmless to the pin (the overlay
overwrites fuel -> 30); flips green when the mapper derives mains gas from the
gas-boiler SAP code (separate mapper-front fix). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The ASHP bundle is a fixed whole-system end-state (confirmed: always the same
contractor cylinder), so the hot-water arrangement is fixed too. The overlay now
sets water_heating_code=901 ("from main system") absolutely, so a combi (909/611)
or electric (903/908) before is reset to HW-from-the-heat-pump — previously the
overlay relied on the before already lodging 901 (true for boiler-1, not in
general). No-op for the boiler-1 pin (stays 1e-4). Cascade pins for combi /
electric-with-cylinder befores await example certs. ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A typical mains-gas combi house re-lodged as an air-source heat pump closes at
1e-4 (gas-boiler 1 example from the technical specialist). Closes one named gap
the pin surfaced: a whole-system replacement to a PCDB-indexed system left the
old Table 4a sap_main_heating_code (104) beside the new heat-pump index, and the
stale code won the calculator's efficiency dispatch (hot water billed at boiler
not HP efficiency, ΔSAP 3.98). _fold_heating now enforces the mutual exclusion
of the two efficiency anchors (setting an index clears the SAP code and vice
versa). Also fixed a pre-existing pyright annotation in the lighting applicator
test. ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the air-source heat-pump Option to the competing "Heating & Hot Water"
bundles. Its overlay is the absolute heat-pump end-state (fixed representative
PCDB index 101413 + category 4 + control 2210 + HWP cylinder + single meter +
off mains gas), pinned against the relodged after-cert next slice. Eligibility
is physical/planning only (ADR-0024, research-grounded): any non-flat
house/bungalow, not listed/heritage (PlanningRestrictions.blocks_internal —
conservation is offered with a caveat, not excluded), not already a heat pump;
floor area / built form / fuel / fabric are deliberately not gates. recommend_
heating gains a restrictions param (defaulted). An already-HHR electric house
now correctly gets ASHP as a better end-state.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The same absolute-target HHR overlay reproduces the common relodged after from
two different base systems (existing electric storage; "no system present"
electric) — proving the bundle is a true whole-system end-state. Closes one
named gap the pin surfaced: the relodged HHR cylinder lodges
cylinder_thermostat='Y', so HeatingOverlay + _fold_heating + the HHRSH overlay
gain cylinder_thermostat (ΔSAP 0.065 -> <1e-4). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The heating Recommendation Generator (HHRSH first). Emits one "Heating & Hot
Water" Recommendation whose competing whole-system bundles the Optimiser picks
from; this slice builds the high-heat-retention storage Option. Its overlay is
the absolute HHR end-state (Table 4a code 409 + control 2404 + dual off-peak
meter + off-peak electric cylinder), pinned against the relodged after-cert in
the next slice. Eligibility translates legacy is_high_heat_retention_valid to
structured predicates (electric or off-gas main, not already HHR/heat-pump).
mains_gas and the heat emitter are unchanged by the measure, so unset. ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The 5th EpcSimulation overlay surface and the deepest applicator fold yet: a
heating bundle is a whole-system replacement, so _fold_heating routes its
absolute-target fields across main_heating_details[0] (fuel/emitter/control +
sap_main_heating_code OR index+category), sap_heating (water_heating_* +
cylinder), the top-level EpcPropertyData (has_hot_water_cylinder), and
sap_energy_source (meter_type, mains_gas). ADR-0024.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Modelling glazing overlay's draught-proofing recompute (RdSAP 10 §8.1 —
a count over openable windows + doors) needs every openable window captured
with its draught_proofed flag. cert 001431's §11 lodges 17 windows but only
14 surfaced, via two distinct gaps:
1. Extractor (_extract_windows_from_layout): the one "Double glazing, known
data" row whose §11 Data-Source cell is "BFRC data" was rejected — it is
laid out as a standalone keyword line with the U-value on the next line
and lodges no Frame Type/Factor/Gap cells, so it never matched the joined
"<source> <U>" Manufacturer-line shape. Now anchored by a standalone
data-source form, with the RdSAP 10 §3.7 default frame factor (0.7) for
the absent frame cell.
2. Mapper (_is_elmhurst_roof_window): the two "Double pre 2002" rows
(U 3.1 / 3.4 > 3.0) were reclassified as roof windows by the U-value
backstop even though both are lodged on an "External wall". A window
lodged on a wall is vertical by definition; guard the U-value backstop so
it only fires when location/BP give no roof signal. The backstop's only
pinned cert (000516 W6) hand-builds its sap_roof_windows and so is
unaffected.
With both closed: 17 sap_windows, 0 misrouted to sap_roof_windows, 14
draught-proofed — reconstructing Elmhurst's lodged 84% (16/19 = (14 windows
+ 2 doors) / (17 windows + 2 doors)). Full calculator + modelling +
orchestration suites green (1885 pass); the 2 glazing draught-proofing
xfails remain (the overlay recompute is the glazing agent's front).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the lighting generator (ADR-0023): two real Elmhurst before/after
cascade pins, sourced from the low_energy_lighting recommendation folder. Both
close cleanly at 1e-4 with NO xfail — lighting changes only bulb counts →
Appendix L (232), no fabric coupling (contrast glazing's draught-proofing).
- zero existing LEDs: 20 incandescent → 20 LED
- some existing LEDs: 5 LED + 15 incandescent → 20 LED (partial-upgrade path)
The overlay-emits-correct-counts assertion lives in the Slice 2 unit tests.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of the lighting generator (ADR-0023): detect non-LED bulbs
(incandescent + CFL + low-energy-unknown > 0) and emit one "Lighting"
Recommendation whose single low_energy_lighting Option converts every bulb to
LED — the overlay sets led = total, the other three counts 0. Priced as a flat
per-bulb average x the non-LED count, contingency 0.26; the description names
"LED" while the measure_type stays MEASURE_MAP-aligned. None when already
all-LED or no bulb counts are lodged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the lighting generator (ADR-0023): the first whole-dwelling,
top-level overlay surface. LightingOverlay carries the four fixed-lighting
bulb-count fields by their exact EPC names (all Optional, absolute counts) +
EpcSimulation.lighting. The applicator's _fold_lighting writes the non-None
counts directly onto the result EpcPropertyData by name (setattr) — simpler
than ventilation's nested fold since the counts live top-level. Baseline
unmutated; pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
With the mapper now in main, cert 001431 parses: it lodges four single-glazed
windows — codes 1 ("Single") and 15 ("single glazing, known data", a single
pane with manufacturer U/g). The generator only detected code 1, so it missed
two panes. Detect {1, 15}; set the secondary target to code 11 ("Secondary
glazing - Normal emissivity", what the cert re-lodges; score-neutral vs 7 but
exact).
A deterministic green pin proves the overlay reproduces the after's 14 windows
exactly. The full-SAP before->after pins are xfail(strict) tripwires: the
overlay nails the windows, but the measure also re-lodges percent_draughtproofed
84->100 (sealed units draught-proof the replaced openings) plus a ~0.4 SAP
fabric residual the overlay doesn't model yet — a glazing-measure coupling to
close later.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ADR-0019 warns that wall_construction code 8 is Park home (PH), NOT system-
built. It was already excluded (8 isn't in the constructable-options map), but
only implicitly. Add an explicit early-return + named constant so a park home
can never be mis-keyed as system-built, with a pin as the tripwire. A park
home's proprietary panel is never EWI/IWI-suitable.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The merged per-cert-mapper-validation work disambiguates Elmhurst 'SY System
build' from 'B Basement wall' (both lodged wall_construction=6), so
main_wall_is_basement is no longer wrongly True for system-built and the
solid-wall generator offers EWI+IWI. The strict xfail now XPASSes; drop the
marker so it stands as a real green cascade pin.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A room-in-roof carries its insulation on its own sloping/stud/gable surfaces
(RdSAP 10 §3.10, Table 17/18), which the roof overlay's flat
roof_insulation_thickness bump cannot model. Without a guard a RR with an
uninsulated loft fell through to the loft fallback and mis-recommended 300 mm
loft insulation. Return None when the main part lodges a sap_room_in_roof,
deferring until a dedicated RR branch lands (ADR-0021).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 of the glazing generator (ADR-0022): a conservation/listed/heritage
protection (PlanningRestrictions.blocks_external) hard-picks secondary_glazing
instead of double_glazing -- an internal second pane, since the external units
can't be replaced on a protected building. Each single-glazed window upgrades
to the secondary target pinned from cert 001431 (glazing_type=7, u_value=2.90,
solar_transmittance=0.85 -- the outer single pane still drives solar gain).
The before/after cascade pins for both measures remain deferred behind the
glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The glazing Recommendation Generator (ADR-0022): detect single-glazed
windows (SAP10.2 Table U2 code 1) and emit one "Windows" Recommendation whose
single Option rewrites every single-glazed window to the double-glazing target
pinned from cert 001431's before->after (glazing_type=5, u_value=1.40,
solar_transmittance=0.72). The overlay writes the per-window U/g into
WindowTransmissionDetails because the calculator consumes those directly.
Priced as a flat per-window average x count. No single-glazed windows -> None.
Planning gate (-> secondary) and the before/after cascade pins land next; the
pins are blocked on glazing-label mapper coverage (owned by another agent).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The double_glazing / secondary_glazing Elmhurst before→after Summaries the
glazing generator's cascade pins will use (ADR-0022). NB: these don't parse
yet — cert 001431 lodges several unmapped glazing labels ("Secondary glazing",
"Secondary glazing - Normal emissivity", "Triple pre 2002", truncated
"Double…"/"Triple…" variants) that the mapper must cover first.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the glazing generator (ADR-0022). `WindowOverlay` (all-optional
partial of one SapWindow) + `EpcSimulation.windows` keyed by sap_windows index.
The applicator folds it onto sap_windows[i]: glazing_type flat on the window,
u_value/solar_transmittance routed into its WindowTransmissionDetails (created
if absent) — the applicator's first nested write, because that's where the
calculator reads window heat loss and solar gain. Baseline left unmutated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 3 (ADR-0021). The dispatcher gains a flat-roof branch: a "flat"
roof_construction_type with no lodged thickness (uninsulated → None on the
Elmhurst path) gets a single flat_roof_insulation Option whose overlay raises
roof_insulation_thickness to 200 mm — tested before the loft fallback so a flat
roof's None doesn't trip the loft trigger. Pinned against the Elmhurst
before→after cert at 1e-4. Golden cohort roof firing unchanged (none across 57).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 (ADR-0021). `recommend_roof_insulation` now owns the loft branch as the
fallback — a plain pitched loft, a thatched roof (the covering doesn't block
insulating the loft floor), or an unlodged roof type all take loft (joist)
insulation at 300 mm when `roof_insulation_thickness == 0`. Sloping is tested
first; a no-access roof gets nothing. Retired the standalone
`recommend_loft_insulation`; the orchestrator and its tests now call the
dispatcher.
Pinned: thatch before→after (None→300) reproduces at 1e-4; the existing loft pin
still holds through the dispatcher. Behaviour-preserving on the golden cohort
(roof measure unchanged: none across all 57) — the dispatch is strictly more
precise (won't fire loft on a sloping/no-access roof).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of the roof-insulation generator (ADR-0021). New `recommend_roof_insulation`
dispatcher keys on the `roof_construction_type` string: a "sloping ceiling" roof
that is uninsulated (roof_insulation_thickness 0/None) gets a single
`sloping_ceiling_insulation` Option whose overlay raises roof_insulation_thickness
to 100 mm. Pinned against the Elmhurst before→after cert 001431 at 1e-4.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>