Commit graph

562 commits

Author SHA1 Message Date
Daniel Roth
6335796d6e
Merge pull request #1471 from Hestia-Homes/feature/abri-api-integration
Abri OpenHousing DomnaRelay — GetTenantData vertical (tenancy signatories to HubSpot)
2026-07-06 16:15:36 +01:00
Daniel Roth
06354a166e Phone-number selection policy lives in the domain layer 🟪
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-06 14:47:37 +00:00
Jun-te Kim
c238a0e6a0
Merge pull request #1449 from Hestia-Homes/feat/sap-corpus-campaign
fix(rdsap): RdSAP 10 Table 13 200/280mm solid-brick wall boundary
2026-07-06 12:25:17 +01:00
KhalimCK
180863ed41
Merge pull request #1456 from Hestia-Homes/fix/electric-boiler-cpsu-companions
Electric boiler/CPSU overrides drag category 2 and the conservative Group 1 control (#1444 A+B for 191/192)
2026-07-06 12:07:25 +01:00
KhalimCK
6dfaecc352
Merge pull request #1460 from Hestia-Homes/fix/table-12a-underfloor-rows
Electric underfloor codes resolve their Table 12a Grid 1 rows (ADR-0050 deferred follow-up)
2026-07-03 17:53:59 +01:00
KhalimCK
adcdce4271
Merge pull request #1462 from Hestia-Homes/fix/floor-u-value-gate
Floor insulation gated on the derived floor U-value (ADR-0051 floor arm)
2026-07-03 17:53:34 +01:00
Khalim Conn-Kowlessar
04810896e0 A community override keeps an assessor-observed Group 3 control 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 16:33:40 +00:00
Khalim Conn-Kowlessar
2bfda711d8 Community-heating overrides default to Group 3 control 2313 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 16:32:15 +00:00
Khalim Conn-Kowlessar
128981289a Floor insulation is withheld when it cannot lower the derived floor U 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 16:05:04 +00:00
Khalim Conn-Kowlessar
f604672ae0 Electric underfloor codes resolve their SAP 10.2 Table 12a Grid 1 rows 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 15:57:37 +00:00
Daniel Roth
c0d36d1e67
Merge pull request #1458 from Hestia-Homes/feature/abri-api-integration
Abri DomnaRelay client — foundation + LogJob vertical (strictly typed)
2026-07-03 16:49:46 +01:00
Daniel Roth
caffa5c4e1 Abri job descriptions identify the visit as a Domna condition survey 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 14:33:40 +00:00
Daniel Roth
2c660bdb5d Abri unparseable confirmed time fails loudly rather than silently booking all day 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 14:33:12 +00:00
Daniel Roth
eccc03f9f2 Abri confirmed time at or after midday books the afternoon slot 🟩
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 14:32:49 +00:00
Daniel Roth
fcdab30b73 Abri confirmed time before midday books the morning slot 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 14:31:51 +00:00
Daniel Roth
da4caea407 Abri booking with no confirmed time books an all-day appointment 🟥
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 14:31:12 +00:00
Khalim Conn-Kowlessar
1925cdd65d An incomplete heating companion set raises instead of logging 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:21:34 +00:00
Khalim Conn-Kowlessar
61f9a63b66 Community-heating overrides drag the conservative Group 3 control (2301) 🟩
The last real archetype on the companion-gap log; the log test now
simulates a future incomplete archetype (warm-air heat pump, Group 5
control deliberately unmapped).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:21:03 +00:00
Khalim Conn-Kowlessar
950ec31d84 Community-heating overrides drag the conservative Group 3 control (2301) 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:19:52 +00:00
Khalim Conn-Kowlessar
6d414c7b51 Air-source heat-pump overrides drag the conservative Group 2 control (2201) 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:18:16 +00:00
Khalim Conn-Kowlessar
7a99c7eccb Electric boiler overrides no longer log an incomplete companion set 🟩
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:08:30 +00:00
Khalim Conn-Kowlessar
afa781719d Electric boiler and CPSU overrides drag the conservative Group 1 control (2101) 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:07:22 +00:00
Khalim Conn-Kowlessar
6d8139e47e Electric boiler and CPSU overrides stamp the Table 4a boiler category (2) 🟥
Supersedes the "direct-acting electric drags no control/category" pin:
None does not mean unset — it means inherit the replaced system's value
(ADR-0048 bug class), verified suppressing HHRSH on portfolio 796.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 14:06:06 +00:00
Jun-te Kim
f629b42bd2
Merge pull request #1448 from Hestia-Homes/fix/full-sap-export-capable-mapping
Full-SAP certs carry their lodged PV export-capability flag (WS3 of #1435)
2026-07-03 13:32:53 +01:00
Jun-te Kim
23ebd5e637
Merge pull request #1446 from Hestia-Homes/fix/ashp-size-to-dwelling-heat-loss
Size the ASHP to the dwelling's design heat loss (fix undersized fixed pump scoring below baseline)
2026-07-03 13:32:30 +01:00
Jun-te Kim
5cae4a0ce5 fix(rdsap): RdSAP 10 Table 13 200/280mm solid-brick wall boundary
_u_brick_thin_wall_age_a_to_e's `<= 280` check put an uninsulated solid-
brick wall of exactly 280mm in the "200 to 280mm -> 1.7" row; RdSAP 10
§5.7 Table 13 (spec PDF p.41) shares 280 as an unlabelled edge between
that row and "280 to 420mm -> 1.4", so the table text alone doesn't say
which row owns it.

Found by building cert 100031768368 (280mm exactly, band C) in Elmhurst
and comparing every worksheet line to the calculator: volume/ACH/floor/
doors matched exactly, but the wall didn't (1.70 vs Elmhurst's 1.40)
despite an identical input crosswalk. Initially reverted a first attempt
at this fix when it appeared to regress an already-pinned cert
(217091901, band A, also nominally 280mm, previously "confirmed" at
U=1.70) — but that cert's build script never actually set a wall
thickness field, so its shared Elmhurst assessment had silently
inherited a stale 260mm from an earlier build. Fixed that build script
and rebuilt with the correct 280mm entry: Elmhurst's worksheet now also
gives U=1.40, matching 100031768368 and confirming the fix rather than
contradicting it.

Both certs move to (near-)exact lodged matches: 100031768368 59.12 ->
61.21 (lodged 61, within 0.5); 217091901 60.82 -> 61.59 (lodged 62,
exact). Corpus gauge 77.8% -> 78.6% within-0.5, MAE 0.636 -> 0.627 (14
corpus certs lodge exactly 280mm solid brick). TDD'd, 46 pins + full
suite green (2310 passed).

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 12:25:07 +00:00
KhalimCK
ebca28f704
Merge pull request #1447 from Hestia-Homes/fix/electric-underfloor-pathway-and-noop-walls
Electric underfloor gets its heating pathway; wall insulation gated on derived U (WS2 of #1435)
2026-07-03 13:17:36 +01:00
Khalim Conn-Kowlessar
325c0ea257 Merge remote-tracking branch 'origin/main' into fix/full-sap-export-capable-mapping 2026-07-03 12:11:25 +00:00
Khalim Conn-Kowlessar
c5b55197b4 Full-SAP certs carry their lodged PV export-capability flag 🟩
`from_sap_schema_17_1` hardcoded is_dwelling_export_capable=False, so
SAP 10.2 Appendix M1 zeroed the PV export credit on every export-capable
full-SAP cert. Cert 0380-3044-6070-2305-5925 (property 741840, PRD #1435
WS3) now reproduces its lodged 92 exactly (was 89); the existing
19.1.0 pin 10096028301 closes its documented -1 residual (84 -> 85 =
lodged). The full-SAP top-level pv_connection is deliberately NOT
carried: its enum disagrees with the RdSAP one the calculator gates on.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 12:09:04 +00:00
Khalim Conn-Kowlessar
6656d8dec2 A full-SAP export-capable PV cert reproduces its lodged SAP 10.2 score 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 12:05:04 +00:00
Jun-te Kim
5c510e1b15
Merge pull request #1439 from Hestia-Homes/feat/sap-corpus-campaign
test(accuracy): corpus-1000 — 74.2% → 77.7% within-0.5, MAE 0.721 → 0.637 (8 fixes; mapper+calc validated vs Elmhurst)
2026-07-03 12:52:57 +01:00
Khalim Conn-Kowlessar
da4aec9840 Treatable old-band solid walls keep their EWI and IWI options under the gate 🟩
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:41:56 +00:00
Khalim Conn-Kowlessar
5f74c34f9a Cavity fill is withheld when it cannot lower the derived wall U 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:41:02 +00:00
Khalim Conn-Kowlessar
574e58a5c8 Solid-wall insulation is withheld when it cannot lower the derived wall U 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:39:32 +00:00
Khalim Conn-Kowlessar
573588d4e7 Underfloor overrides no longer log an incomplete companion set 🟩
Regression guard: category 8 + control 2701 keep the ADR-0048 coherence
invariant satisfied for SAP codes 421/422/424.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:37:57 +00:00
Khalim Conn-Kowlessar
566374bf34 Electric underfloor override drags the conservative Group 7 control (2701) 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:36:51 +00:00
Khalim Conn-Kowlessar
51fa497793 Electric underfloor override stamps the Table 4a underfloor category (8) 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:35:55 +00:00
Khalim Conn-Kowlessar
ac2b600bbd Merge remote-tracking branch 'origin/main' into fix/ashp-size-to-dwelling-heat-loss 2026-07-03 11:02:42 +00:00
Khalim Conn-Kowlessar
bf240e3315 ASHP sizing targets the Appendix-N efficiency peak (realistic installed pump) 🟩
Sizing selects the aroTHERM plus rung nearest PSR ~0.8 (0.8 x design heat
loss) — the Appendix-N efficiency peak, reproducing the pump a real
installer fits — rather than the MCS PSR>=1.0 capacity target, which
oversizes. Validated against the relodged Elmhurst ASHP cert (delta 0
held at the 5 kW Vaillant); the two self-snapshot pins re-pin to their
correctly-sized larger pumps, and the orchestrator/harness thread the
calculator's design heat loss so production sizes to the dwelling. Manual
SapResult test stubs carry the new design_heat_loss_kw field.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 11:02:13 +00:00
Khalim Conn-Kowlessar
6f70e65bc4 ASHP cost sizes to the threaded design heat loss over the floor-area proxy 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:29:14 +00:00
Khalim Conn-Kowlessar
2dd637a657 The ASHP bundle sizes the heat pump to the dwelling's design heat loss 🟩
_ashp_option now selects the aroTHERM plus PCDB record matching the
threaded design heat loss (floor-area proxy fallback), so the overlay's
efficiency anchor is sized to the dwelling instead of a fixed 5 kW unit.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:28:08 +00:00
Khalim Conn-Kowlessar
df38dda7b0 The ASHP bundle sizes the heat pump to the dwelling's design heat loss 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:26:35 +00:00
Jun-te Kim
645789456e docs(corpus): find the third driver — mixer-shower default, 91% of gap now traced
Walked the water-heating worksheet section: assumed occupancy (42) matched
exactly (2.4234 both sides), but (43) average daily hot water use was
117.41 L/day (Elmhurst) vs 110.73 L/day (ours) — same occupancy, different
shower/bath demand. Root cause: the cert's shower_outlets field is
genuinely unlodged, which the mapper correctly maps to 0 mixer showers
per its documented, already-validated "no entry = no shower" convention.
Elmhurst's build shows a "Non-electric shower" fixture anyway — its UI
silently defaults one when the build script doesn't explicitly configure
"0 showers" to match the cert.

Verified: a single 7 L/min vented mixer reproduces Elmhurst's (42a)
monthly series exactly (4 d.p., all 12 months) and closes hot water to
2616.04 vs Elmhurst's 2616.03. Corpus-wide check across 170 certs sharing
this "bath present, no shower data" pattern shows no systematic bias
(mean dSAP +0.12, median -0.04) — confirms the mapper convention is
correct on average; this is a build-entry artifact on this one cert, not
a mapper bug (no code change warranted).

Combining all three found causes (window orientation, Table 11, shower
default): SAP 72.4567 vs Elmhurst's precise 72.0681 — residual 0.39,
~91% of the original 4.26-point gap now precisely explained.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 10:19:05 +00:00
Khalim Conn-Kowlessar
cd4ed81185 The calculator exposes the dwelling design heat loss for heat-pump sizing 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:16:43 +00:00
Khalim Conn-Kowlessar
7707df3294 ASHP sizing caps at the largest pump for a high-heat-loss dwelling 🟩
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:14:10 +00:00
Khalim Conn-Kowlessar
b37be6327c ASHP sizing selects the smallest pump meeting the dwelling's design heat loss 🟥
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 10:13:19 +00:00
Jun-te Kim
d15ea8b7d4 docs(corpus): find the second driver of 100061275133's residual gap
Walked the worksheet section-by-section (dimensions, ventilation, fabric,
internal/solar gains, MIT, space-heating requirement, fuel cost) against
the calculator's matching intermediates. Internal gains and heat loss
matched closely, but solar gains (worksheet line 83) was 2.2x off in
January (56.9 W vs our 123.4 W) — traced to the Elmhurst BUILD entering
all 12 real windows (3 orientations: NW 7.05 m2, NE 1.21 m2, SE 7.06 m2)
as a single synthetic 15.32 m2 "North" group, understating solar gain.

Verified by reproducing both build artifacts in the calculator: real
windows + real Table-11 gating = 76.33 (our answer, matches lodged 76
exactly); collapsing to a synthetic single-North window + forcing Table
11 on = 72.62, reproducing Elmhurst's 72 almost exactly. Confirms neither
residual is a mapping or calculator bug — one is a deliberate,
regression-tested spec choice (Table 11) and the other is an artifact of
how this specific Elmhurst reconciliation build was entered.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 09:52:22 +00:00
Jun-te Kim
f69d345493 docs(corpus): correct 100061275133 pin comment — real driver is Table 11
The prior comment blamed a stale build-side combi artifact (already fixed
this session) and my earlier conversational claim that Elmhurst's overall
SAP used regional weather was wrong too — verified the worksheet's (5)
dwelling volume and wind table match our UK-average rating cascade exactly.

The actual, now-quantified driver: Elmhurst's worksheet (201)/(202)/(215)
show it unconditionally applies SAP 10.2 Table 11's 10% secondary/portable-
electric-heater fraction based on main heating category alone, with no
secondary lodged on the cert. Our `_secondary_fraction` deliberately gates
this on an actual lodged/forced secondary (see the adjacent S-B30 note:
applying it unconditionally regressed the full 1000-cert corpus MAE by
+0.16). Forcing Table 11 on for just this cert moves 76.33 -> 73.62 (~62%
of the 76.33-vs-72 gap) — confirms this, not a mapping error, drives the
residual. Documented so the next reader doesn't re-litigate it.

Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
2026-07-03 09:41:09 +00:00
Khalim Conn-Kowlessar
dd30903ace Merge remote-tracking branch 'origin/main' into fix/electric-room-heater-overlay-companions 2026-07-03 09:25:11 +00:00
Khalim Conn-Kowlessar
962a443ed2 A complete room-heater overlay does not log a companion gap 🟩
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-03 09:17:06 +00:00