The financial-uplift model per ADR-0018. `estimate_valuation_uplift(
current_band, target_band, current_value=None, total_cost=None)` returns
a `ValuationUplift`: band-transition uplift compounded from four broker
tables (MoneySupermarket / Lloyds per-step, Knight Frank / Rightmove
whole-jump), taking min/max/mean across the covering sources. Always a
percentage; absolute £ forms (increase at each bound + post-retrofit
value) only when a current market value is supplied; the 2x ROI cap
rescales the percentages and can only bite once a value is known. A
non-improving jump is a clean 0% no-op.
Pure function, no external dependency. Persisting it (where the value
lands) and sourcing the current market value stay deferred (ADR-0018).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Cert 9390 (community mains-gas boiler, API main_fuel_type=20) drew £0
standing charge → fuel cost under-counted → SAP read +4 high (71 vs 67).
Root cause: the standing-charge logic (`additional_standing_charges_gbp`)
only knows the GAS branch (`_is_gas_code`) and the off-peak-electric branch.
A heat-network community fuel is not a Table-32 gas code — EPC 20 = "mains
gas (community)" normalises to Table-32 code 20 (biomass), so
`_is_gas_code(20)` is False and the standing came out £0. The Summary path
masks this because it lodges community gas as Table-32 code 1 (ordinary
mains gas), which IS gas-recognised and already draws the £120 gas standing
— so the CH1-6 corpus was unaffected while the API path lost the charge.
Spec basis (verified against SAP 10.2 spec PDF):
- Table 12 (p.191) "Heat networks" row standing charge = £120/yr, note (k).
- Note (l): "Include half this value if only DHW is provided by a heat
network."
- §C3.2 (p.58): the full charge applies when the space heating is also a
heat network.
Worksheet-validated: simulated case 14 (community boilers + mains gas,
space + water) → worksheet (351) Additional standing charges = £120.
Fix: new `_heat_network_standing_charge_gbp(epc, main)` returns the
heat-network standing (£120 full when the space main is a heat network;
£60 when only DHW is on the network) or None otherwise. Applied at both
fuel-cost call sites, REPLACING the fuel-based `additional_standing_charges
_gbp` for heat-network mains (NOT additive) so a Summary-path community-gas
main — already £120 via the gas branch — is not double-counted to £240. The
CH1-6 community corpus stays exactly £120 (59 corpus tests pass).
9390 SAP +4 → -2 (cont 65.39 vs lodged 67): the spec-correct £120 standing
EXPOSES a separate ~7% demand over-count (also visible as PE 220 vs lodged
205) — a heat-source-efficiency-default / fabric residual, follow-up scope.
9390 is unpinned (retired P2.2 per ADR-0010 §10); helper locked by 2 unit
tests. Full suite 2386 passed, 1 skipped.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Cert 9390-2722-3520 (community mains-gas boiler scheme, sap_main_heating_
code=301, main_fuel_type=20) emitted CO2 0.44 t vs lodged 2.8 t — 6.4x low.
Root cause: the EPC `main_fuel_type` enum and the SAP Table 12 / Table 32
fuel-code numbering COLLIDE in the 18-25 range. Per
`datatypes/epc/domain/epc_codes.csv` (RdSAP-Schema-17.0) EPC fuel
20 = "mains gas (community)", but Table 12/32 code 20 is a solid biomass
fuel (CO2 0.028, PE 1.046, wood-logs price). The factor lookups
(`co2_factor_kg_per_kwh` / `primary_energy_factor` / `unit_price_p_per_kwh`)
check the Table-12/32 dict FIRST, so the EPC community fuel 20 silently
returned the biomass factor instead of translating 20 -> Table 12 code 51
(community mains gas: CO2 0.210, PE 1.130, mains-gas price).
Fix: new `_heat_network_factor_fuel_code(main)` translates the EPC community
fuel to its Table-12 code via `API_FUEL_TO_TABLE_12`, but ONLY for
heat-network mains (`_is_heat_network_main`) — a genuine biomass boiler
(non-community) keeps its raw Table-12 factor. Applied at the five
heat-network factor sites: space-heating CO2 / PE / unit-price and
water-heating (WHC 901) CO2 / PE. The Summary path is unaffected (it maps
"Mains gas - community" to code 1, no collision), so the community-heating
corpus (CH1-6) is untouched.
Worksheet-validated against simulated case 14 (community boilers + mains
gas, SAP code 301): worksheet (367) CO2 factor 0.2100, (467) PE factor
1.1300 — exactly the Table-12 code-51 values the translator now reaches.
9390 CO2 0.44 -> 3.03 t (lodged 2.8; spec-correct factors over the API-only
register residual per [[feedback-worksheet-not-api-reference]]), PE 204 ->
220 (the spec-correct 1.13 factor; the prior 204≈205 match was the
collision coinciding with the register residual). 9390 is unpinned (retired
at P2.2 per ADR-0010 §10); the translator is locked by two unit tests.
REMAINING (separate follow-up): 9390 SAP +4 is a cost-side gap — the
heat-network cost path does not apply the 1/heat_source_eff (1/0.80)
scaling that the CO2/PE paths do, so community fuel cost under-counts.
Suite: 2616 passed, 1 skipped (community corpus green); the 2
test_rdsap_uvalues stone-formula failures are pre-existing (HEAD 58ff7d88).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Closes the Ext1 vaulted-roof over-count that S0380.209 exposed on golden
cert 0240-0200-5706. BP2 lodges roof_construction=5 (vaulted ceiling),
roof_insulation_thickness="NI" (parsed to 0), description "Pitched,
insulated (assumed)", band J. The cascade returned U=0.68 — the RdSAP 10
§5.11.4 (p.44) retrofit-50 mm "insulation at joists" row. A vaulted /
sloping ceiling has no ceiling-joist void, so that row does not apply; per
RdSAP 10 §5.11 Table 18 (p.45) it takes the column (1) age-band default
(band J = 0.16).
The arbiter is the cohort, not the spec text alone: 33 cohort-2 certs
lodge "ND" (thickness None) vaulted roofs (roof_construction=5, band D)
that already pin to their dr87 worksheets at U=0.40 = Table 18 col (1) by
falling through the age-band default. 0240's only difference is the "NI"
sentinel (insulation present, unknown thickness) which uniquely hit the
0.68 override. (The S0380.209 note's predicted "cont ≈ 72.31" assumed a
col-3 0.25 value; the cohort's ND vaulted roofs disprove that — they use
col (1), so 0240 lands at cont 72.4617.)
Implementation: new `u_roof(is_sloping_ceiling=...)` flag, threaded from
heat_transmission for roof_construction_type containing "sloping ceiling"
(code 8) or "vaulted" (code 5). It fires only for the NI case
(thickness 0 + "insulated (assumed)"), routing to the col (1) age-band
default; the "ND"/None path is untouched (already col 1) and a NORMAL
pitched-with-loft roof still takes the §5.11.4 50 mm row (flag defaults
False). roof 76.93 → ~68 W/K → 0240 PE +5.5044 → +1.5181, CO2 +0.2757 →
+0.0728 (SAP integer 72 unchanged — the true value; lodged 73 needs the
unpreserved 2013+ pump).
Also corrects test_u_wall_cavity_as_built_partial_insulation_routes_to_
filled_cavity_row → ..._routes_to_as_built_row: a missed S0380.210
follow-up. That test (in domain/sap10_ml/tests/, which the AGENT_GUIDE §4
suite command does not run) asserted the pre-S0380.210 "partial insulation
→ filled" behavior on legacy-map parity, not worksheet evidence; S0380.210
corrected it to the as-built row per RdSAP 10 Table 6 + golden cert 0390's
four-metric closure.
Suite: 2614 passed, 1 skipped; the 2 remaining failures in
test_rdsap_uvalues.py (stone §5.6 thin-wall formula vs Table-6 1.7 cap)
are pre-existing (fail at HEAD 58ff7d88, before this branch's work).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Golden cert 0390-2954-3640 (detached, TFA 360, age F) carried a +7 SAP /
-28 kWh/m² PE residual the audit attributed to a demand-side fabric gap.
Walking the §3 cascade localised it to the Main wall: lodged
wall_construction=4 (cavity), wall_insulation_type=4 (as-built / assumed),
description "Cavity wall, as built, partial insulation (assumed)". The
cascade mis-routed it to the Table 6 "Filled cavity" row (band F = 0.40)
because `_described_as_insulated` matches the "partial insulation"
substring.
RdSAP 10 Specification (10-06-2025) Table 6 — Wall U-values, England
distinguishes two cavity rows:
"Cavity as built" A-E 1.5, F 1.0, G 0.60, H 0.60, I 0.45, J 0.35, ...
"Filled cavity" A-E 0.7, F 0.40, G 0.35, H 0.35, I 0.45†, J 0.35†, ...
An "as built ... partial insulation (assumed)" cavity is the as-built
partial fill of the age band, NOT a retrofit cavity fill (a genuine fill
lodges the distinct "Cavity wall, filled cavity", wall_insulation_type=2).
It therefore routes to "Cavity as built" (band F = 1.0), mirroring the
worksheet-validated solid-brick rule in S0380.209 (cases 9/10: "as built,
insulated (assumed)" → as-built age-band row, not retrofit).
New `_cavity_described_as_filled` predicate is used only in u_wall's
cavity filled-row branch; it excludes the "partial insulation" substring
while keeping "insulated (assumed)" → filled (the unrelated, separately
asserted test_cavity_as_built_insulated_assumed_uses_filled_cavity_row is
unchanged). The shared `_described_as_insulated` (also consumed by the
roof/floor paths) is left untouched.
Wall HLC +53.6 W/K (U 0.40 → 1.0 over ~268 m²) lifts all four metrics
together — the signature of a real fabric bug, not a tuned offset:
SAP +7 → +0
PE -27.9745 → +0.5281 kWh/m²
CO2 -2.7134 → -0.1189 t/yr
Bands I-M are unaffected (the two rows coincide per the † footnote), so
golden certs 0535 (band M) / 7536 (band L) with "insulated (assumed)"
cavities continue to pin at 0. Full suite 2384 passed, 1 skipped.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The EPC renders a recent-band as-built wall as "<material>, as built,
insulated (assumed)". The API mapper populates epc.walls with that string,
and heat_transmission's wall_ins_present gate keyed off the "insulated"
substring → routed the wall to the RdSAP 50 mm "insulation of unknown
thickness" bucket (e.g. sandstone band J U=0.25) instead of the as-built
age-band row (U=0.35).
Per RdSAP 10 Table 8/9 footnote the 50 mm row applies ONLY when insulation
is "known to have been increased subsequently (otherwise 'as built'
applies)". An "as built ... (assumed)" description is the EPC's age-band
assumption — it only renders on RECENT bands (an old band renders "no
insulation (assumed)"), so the as-built row applies. Genuine retrofit is
signalled by wall_insulation_type (External/Internal/Filled), which the
gate still checks independently.
Worksheet-validated by two new Elmhurst worksheets, both As Built band J:
- simulated case 9: sandstone → (29a) U 0.35
- simulated case 10: solid brick → (29a) U 0.35
both the as-built row, NOT 50 mm (0.25).
Fix: restrict the description-based gate to genuine retrofit via the new
local `_described_as_retrofit_insulated` (excludes "as built"/"(assumed)").
The cavity filled-row routing inside `u_wall` (which uses
`_described_as_insulated` directly) is untouched — the 3 cavity API certs
(0390/0535/7536) are unaffected.
test_heat_transmission: the old `..._uses_50mm_row` test asserted 50 mm via
an IMPOSSIBLE band-B + "insulated (assumed)" combination; corrected to a
valid recent-band (J) scenario asserting the as-built row (35 W/K).
Golden 0240: walls 24.45 → 34.23 W/K (U 0.25 → 0.35). SAP integer 72
unchanged; PE residual re-pinned +1.8687 → +5.5044, CO2 +0.0907 → +0.2757.
This spec-correct fix REMOVED the wall under-count that was masking the
Ext1 vaulted-roof over-count (cascade U 0.68 via the same "insulated
(assumed)" description vs case-9 sloping-ceiling 0.25) — that roof
over-count is the next slice; fixing both lands SAP cont ≈ 72.31 (=
Elmhurst case 9).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds simulated case 7: case 6 (P960-0001-001431) with the heating swapped
to a CONDENSING OIL COMBI (SAP code 130, Table 4b 82/73) and the cylinder
removed — combi instantaneous DHW (WHC 901), Table 3a keep-hot combi loss
(61) = 600 kWh/yr, no primary/storage loss, boiler interlock PRESENT (no
−5pp). This is the heating archetype golden cert 0240-0200-5706-2365-8010
uses, which case 6 (SAP code 127, a *regular* condensing oil boiler +
cylinder) never exercised.
The cascade reproduces the case-7 worksheet EXACTLY at abs=1e-4 on every
top-level SapResult output with ZERO calculator changes:
(211) 7865.4304 (213) 7556.9821 (219) 3496.8121 (98c) 12646.3783
(255) 1123.3372 (257) 1.9631 (272) 5738.9315 (258) 73
This validates the SAP 10.2 Appendix D Eq D1 combi efficiency blend +
Table 3a keep-hot combi loss + Table 4b code 130 (82/73) path, and
exonerates the combi mechanism as the source of 0240's API-path residual
— which therefore lives in 0240's fabric/demand or the API mapper.
Test-only slice (no impl change). New fixture file: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Pull the cumulative-prefix scoring out of `marginal_impacts` into a reusable
`cascade_scores(scorer, baseline, overlays) -> list[Score]` (index 0 the
baseline, one calculator run per prefix) plus a pure `marginals_from_scores`.
Each Score carries its SapResult, so the next slice's telescoping per-measure
bill cascade can re-bill the same prefixes the role-3 attribution already
scores — no extra `calculate` calls (ADR-0014 / ADR-0016). `marginal_impacts`
now delegates; behaviour unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Plan gains optional baseline_bill / post_bill (the Bills derived for the
unmodified and post-package end-states at one Fuel Rates snapshot) and derives
the four plan-level columns: post_energy_bill (post total), energy_bill_savings
(baseline - post), post_energy_consumption (Σ post section kWh), and
energy_consumption_savings (baseline - post delivered kWh). All return None until
billing runs (persisted as NULL), so existing Plan construction and the
not-yet-wired orchestrator stay green. Plan-level only; per-measure savings are a
later slice (ADR-0014 amendment).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Score gains sap_result: Optional[SapResult], populated by PackageScorer with the
calculator output its headline figures came from. This lets the Modelling stage
price the post-package (and baseline) end-state via Bill Derivation reusing a
SapResult already computed by the optimiser's re-score / the orchestrator's
baseline score — no second calculate (ADR-0014 amendment). The optimiser reads
only sap_continuous, so it stays domain-agnostic and the stub scorers (which omit
sap_result) are unaffected — all optimiser tests pass unchanged.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Bill / EnergyBreakdown / BillDerivation / sap_fuel were under
domain/property_baseline/ only because Baseline was built first. The Modelling
stage now needs them too, so move them (and their tests) to a neutral
domain/billing/ — Fuel/FuelRates already live in the shared domain/fuel_rates/.
Avoids a modelling -> property_baseline cross-stage import and a package name
that wrongly implies ownership (ADR-0011, ADR-0014 amendment). Pure git mv +
import rewrite across 10 files; 40 billing/baseline/repo tests pass, pyright
strict clean. CONTEXT.md Bill Derivation location updated.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The warm-start (and max-gain fallback) now price each forced Measure Dependency
the candidate triggers, not just inject it afterwards: optimise/optimise_min_cost
fold dependencies into each candidate's cost+gain via _augmented_cost_gain, and
optimise_package scores each dependency's true role-1 signal (_with_role1_signals)
instead of the 0.0 placeholder. This stops the min-cost objective (i) ignoring the
~£900 a wall drags in (a wall-free package reaching target can be cheaper) and
(ii) picking a small-gain wall whose mandatory ventilation (down to -5 SAP) makes
it net-negative, which repair cannot un-pick.
Budget is now a hard envelope: the constraint applies to the augmented (measure +
its ventilation) cost, so a wall that fits alone but whose ventilation would bust
the budget is DROPPED rather than forced over budget. This reverses the earlier
'forced regardless of budget' call (which made sense when selection was
ventilation-blind). Safety invariant intact — presence still injected on every
path; we just never recommend a wall we can't afford to ventilate. ADR-0016
amendment updated. 94 modelling+orchestration tests pass.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
With S0380.201-206 closing every line ref, the detached dual-oil case 6
(Main 1 radiators 51% / Main 2 underfloor 49%, different parts, no boiler
interlock, 6 roof-of-room rooflights) now matches its P960-0001-001431
worksheet to 1e-4 on the whole SapResult. Registered in
`test_e2e_elmhurst_sap_score.py::_FIXTURE_PINS` (11 pins):
SAP 72 / cont 71.6597, ECF 2.0316, cost 1162.5374, CO2 5953.6679,
space heat (98c) 11991.9611, main fuel (211)+(213) 14736.9564,
HW (219) 4902.8601, lighting (232) 357.6571, pumps (231) 356.0.
This was the validation target the S0380.200 handover set. Updated the
fixture docstring's stale "§3-windows-only" scope note.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SAP 10.2 Appendix D §D2.1(2) Equation D1 blends the monthly water-heater
efficiency by the ratio of the boiler's space-heating load to its water
load. On a dual-main cert the DHW boiler does only its OWN share of space
heating ((204) for Main 1, (205) for Main 2), but the cascade fed Eq D1
the dwelling total ((202) = 1 − secondary). That over-weighted η_winter
and under-stated HW fuel — simulated case 6 (Main 1 serves DHW + 51% of
space heat) was HW −78 kWh vs the worksheet.
New `_water_heating_main_space_fraction` returns the DHW main's total-
space share via `_water_heating_main` (WHC-901 → Main 1 (204); WHC-914 →
Main 2 (205)); single-main / WHC-901 single systems get (202) = 1 −
(201), so they are unchanged. Case 6 (219) HW now 4902.8601 EXACT.
With S0380.205 (demand exact), case 6 now closes to 1e-4 on EVERY metric:
SAP cont 71.6597, ECF 2.0316, cost 1162.5374, (211)+(213) 14736.9564,
(219) 4902.8601, (231) 356, (232) 357.6571, CO2 5953.6679 (rating) /
4895.2137 (demand).
Re-pin: 0240 (dual combi, WHC 901, Main 1 51%) HW rises slightly → PE
+1.6893 → +1.8687, CO2 +0.0815 → +0.0907 (SAP 72 unchanged). Single-main
certs unchanged (2360 pass + 0 fail).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
When two main heating systems heat different parts of a dwelling, SAP
10.2 §7 (PDF p.186) adapts the mean-internal-temperature calculation:
- Table 9b weighted responsiveness: R = (1−(203))·R_sys1 + (203)·R_sys2.
- Rest-of-dwelling temperature (90)m = weighted average of T2 computed
under EACH system's control schedule, weights (203)/[1−(91)] for sys2
and [1−(203)−(91)]/[1−(91)] for sys1 (or sys2's control alone when
(203) ≥ 1−(91)).
The cascade used Main 1's control + R=1.0 for the whole dwelling,
over-stating MIT by +0.037 °C on simulated case 6 (Main 1 radiators/2106
type 2 living + Main 2 underfloor/2110 type 3 elsewhere, R 1.0/0.75). That
inflated (97) heat loss by ~11 W → demand +61 kWh/yr.
`mean_internal_temperature_monthly` gains `main_2_control_type`,
`main_2_fraction`, `main_2_responsiveness`; cert_to_inputs derives them
from the second main detail (gated on main_heating_fraction > 0, so
single-main / DHW-only second mains pass the defaults → unchanged).
Case 6: (87) living, (90) elsewhere, (98c) demand 11991.96 and per-system
fuel (211)=7741.6458 / (213)=6995.3106 all match the worksheet to 1e-4.
Re-pin: golden 0240 (same 2106/2110 archetype, API-only) — PE +2.1519 →
+1.6893, CO2 +0.1051 → +0.0815 (both closer to zero; SAP 72 unchanged).
Single-main certs unchanged (2360 pass + 0 fail).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Prerequisite for the SAP 10.2 p.186 two-systems-different-parts MIT.
When two main systems heat different parts of a dwelling, §14.1 Main
Heating2 lodges its OWN "Heat Emitter" + "Main Heating Controls Sap"
(simulated case 6: Main 1 radiators / control 2106 serving the living
area, Main 2 underfloor / control 2110 serving elsewhere). The extractor
+ mapper dropped both — `MainHeatingDetail.heat_emitter_type` and
`main_heating_control` came through as empty-string sentinels, so the
cascade saw system 2 as having no responsiveness (defaulted R=1.0) and no
control type.
- `MainHeating2` datatype gains `heat_emitter` + `heating_controls_sap`.
- The extractor reads them from the §14.1 block.
- `_map_elmhurst_main_heating_2` maps them via the same helpers as Main 1
(`_elmhurst_heat_emitter_int` → underfloor-in-screed = emitter 2, Table
4d R=0.75; `_elmhurst_sap_control_code` → 2110, Table 4e type 3),
threading the dwelling floor + age band for the underfloor subtype.
Empty-string fallback preserved for the legacy DHW-only Main 2 (cert
000565 §14.1 omits emitter/control). No cascade output changes yet — the
MIT consumer lands in S0380.205. Full suite 2358 pass + 0 fail.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Rewire the objective per the ADR-0016 amendment. With a target_sap (Increasing
EPC): warm-start optimise_min_cost (cheapest package reaching target_gain =
target_sap - baseline within budget) -> inject dependencies -> re-score ->
repair toward target; if the warm-start is infeasible or the repaired package
still falls short on the true score, fall back to max-gain-within-budget (best
effort). Without a target_sap: max-gain (unchanged). The min-cost objective
stops at the target without overshooting into a higher band; surplus budget is
left unspent. Extracted _max_gain_package (no-target path + fallback) and
_repair_to_target (inject + re-score + greedy repair). Dependency injection and
the repair loop are preserved; all prior optimiser + dependency tests pass
unchanged. Ventilation-aware *selection* is the next slice; injection is still
post-warm-start here.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Exact-enumeration sibling to optimise(): pick <=1 option per group to minimise
total cost subject to total gain >= target_gain and cost <= budget (None =
unconstrained). Ties broken toward higher gain ('recommend more'). Returns None
when no package within budget reaches the target (caller falls back to
max-gain); a non-positive target is met by the empty package. This is the
warm-start objective for an Increasing EPC goal per the ADR-0016 amendment
(least-cost-to-target, not max-gain). Dependency-blind for now; ventilation-aware
selection lands in a later slice.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A rooflight deducts from the gross area of the roof element it pierces
(RdSAP 10 §3.7, PDF p.19). A "Roof of Room" rooflight (window_wall_type=4
/ site-notes "Roof of Room") sits on the room-in-roof sloped ceiling, so
its area must deduct from the §3.10.1 RR residual roof — not the flat /
loft external roof.
The cascade deducted every rooflight from the regular roof (heat_
transmission line 814). Simulated case 6's worksheet is the first
worksheet evidence for "Roof of Room" rooflight billing: "Roof room Main
remaining area" net 55.54 = gross 61.73 − 6.19 rooflights (U_RR=0.30),
while "External roof Main" 14.52 carries no opening. New
`_bp_rr_roof_absorbs_rooflight` routes the rooflight area to the RR roof
(simplified A_RR_final or detailed §3.10.1 residual) ONLY when the BP's
RR contributes such a shell AND lodges no explicit roof surface (slope /
flat_ceiling / stud_wall). Case 6 roof (30) 20.2284 → 19.0523 EXACT;
demand gap +153 → +61 kWh/yr.
Preserved: certs 000565 (Ext2 stud walls) and 000516 (slopes) lodge
explicit roof surfaces → rooflight keeps deducting from the regular roof
(their 1e-4 worksheet pins hold). Simplified Type 1 RR is excluded too.
Re-pin (uniform spec application per [[feedback-software-no-special-
handling]] + worksheet-is-truth): API certs 6035 and 0240 are detailed-RR
gables-only like case 6 (no worksheet of their own for rooflights), so
their "Roof of Room" rooflights now deduct from the RR residual too. This
SUPERSEDES the unvalidated S0380.198 "deduct from loft" assumption.
- 6035: roof 78.0648 → 73.9176; the previously-"unexplained" +1.37 PE
residual COLLAPSES to -0.14 (CO2 -0.0004 → -0.0362; SAP exact 70) —
strong corroboration the rooflight-on-RR treatment is correct.
- 0240: PE +2.5812 → +2.1519, CO2 +0.1269 → +0.1051 (SAP 72 unchanged).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The §5 (70) internal-gains mirror of S0380.201's Table 4f (230c). SAP
10.2 Table 5a note a) (PDF p.177) verbatim: "Where there are two main
heating systems serving different parts of the dwelling, assume each has
its own circulation pump and therefore include two figures from this
table. ... Where two main systems serve the same space a single pump is
assumed."
Simulated case 6 (dual oil, 51% radiators + 49% underfloor) lodges Main
1 "2013 or later" (3 W) + Main 2 unknown date (7 W) → worksheet (70) =
10 W in the 8 heating months. The cascade billed a single Main 1 pump
(3 W). New `_second_main_central_heating_pump_gain_w` adds the second
main's gain (at its own pump-age bucket), gated on a lodged
main_heating_fraction > 0 — the same genuine-second-space-heating-main
test as S0380.201, so DHW-only second mains (cert 000565 Main 2 combi via
WHC 914, fraction 0) keep a single pump (70)=3. Refactored the per-detail
pump predicate (`_main_detail_has_central_heating_pump`) and date bucket
(`_pump_date_category_for_detail`) out of the orchestrator.
Re-pin: golden 0240 (dual-main oil combi, both unknown date) (70) 7 → 14
W; the extra internal gain lowers space-heating demand → SAP cont 72.18 →
72.24 (integer 72 unchanged), PE +2.8092 → +2.5812, CO2 +0.1385 →
+0.1269 (both closer to zero). Validated against the case-6 worksheet.
This closes the (70) leg of case 6's space-demand gap. Remaining for full
case-6 closure: roof fabric (37) +1.176 W/K (room-in-roof shell) and HW
(216) Eq-D1 water efficiency −1.6%.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
measure_dependency.py now owns only the selection semantics: the trigger set and
the forced-edge wrapping. It delegates production (detection + pricing) to
recommend_ventilation and wraps the returned Recommendation into the
MeasureDependency, picking the cheapest Option (one MEV today; readies the seam
for MEV-c / MVHR). The orchestrator's _measure_dependencies call is unchanged.
Trimmed the now-redundant option-detail assertions — those live in
test_ventilation_recommendation. 138 pass, behaviour-preserving.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_ventilation(epc, products) does the same two jobs as wall/roof/floor —
detect applicability (the has_ventilation guard) and price the work (2 MEV units
+ contingency) — and returns a Recommendation. Ventilation is a Recommendation
like the others; what makes it special (forced when fabric is selected, excluded
from the free pool) stays in the Measure Dependency layer. Detect + price now
live in generators/, not inline in measure_dependency.py. Note it is NOT run by
the candidate-pool runner — it is consumed only by the dependency path.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Simulated case 6 (P960-0001-001431, dual oil boiler 51% rads + 49%
underfloor) worksheet (231) = 356 = (230c) central-heating pump 156 +
(230d) oil boiler pump 200. (230c) decomposes per SAP 10.2 Table 4f
note c) (PDF p.175): "Where there are two main heating systems include
two figures from this table" — Main 1 41 kWh (pump age "2013 or later")
+ Main 2 115 kWh (pump age unknown). The cascade summed only Main 1's
circulation pump, giving (231) = 241.
cert_to_inputs now adds the second main's circulation pump, gated on a
lodged main_heating_fraction > 0 (a genuine second SPACE-heating main —
the same test §9a uses to split space-heating demand). This excludes
DHW-only second mains (cert 000565 Main 2 = gas combi via WHC 914,
fraction 0); without the gate 000565's worksheet pins regressed +115 kWh.
Re-pin: golden 0240 (dual-main oil combi, API-only, no worksheet) gains
its Main 2 pump too (pumps_fans 315 → 430). Spec-correct per
note c and validated by the case-6 worksheet; SAP cont 72.55 → 72.18
(integer 73 → 72, resid +0 → -1), PE +1.9459 → +2.8092, CO2 +0.1226 →
+0.1385. The lodged 73 carries Elmhurst's own residual; the worksheet-
backed case 6 is the spec authority for the archetype.
Note: the boiler-interlock −5pp per-main determination the prior
handover flagged as the priority is already implemented (S0380.141
cylinder-thermostat path + S0380.177 room-thermostat path) — case 6
already produces (206)=79 / (207)=84 exactly, and 0240 is a combi with
no cylinder so correctly unpenalised.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
domain/modelling/ had grown to 15 flat modules. Group the behavioural ones into
subpackages — generators/ (wall/roof/floor Recommendation Generators), scoring/
(overlay applicator, package scorer, role-1/3 scoring), optimisation/ (optimiser
+ measure dependency) — and leave the shared value-object vocabulary
(recommendation, plan, scenario, product, contingencies, simulation) flat at the
top, since it is imported everywhere. Pure move + import-path rewrite across 89
import sites; no behaviour change. 136 pass, pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
ventilation_dependency(epc, products) returns the forced 'fabric requires
ventilation' edge: triggers = MEASURES_NEEDING_VENTILATION (cavity/internal/
external wall, mirroring legacy assumptions.measures_needing_ventilation), and a
required Option installing decentralised MEV (mechanical_ventilation_kind=
EXTRACT_OR_PIV_OUTSIDE), priced at two fully-loaded units. Returns None when the
dwelling already lodges a mechanical ventilation kind (legacy has_ventilation
guard), so MEV is never forced onto an already-ventilated dwelling.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
MeasureDependency(triggers, required) is a data-declared 'A requires B' edge.
optimise_package gains a dependencies param: after the warm-start it injects any
dependency whose triggers intersect the selected measure-types, BEFORE the
whole-package re-score, so the dependency's (negative) SAP lands in the truthful
figure and the undershoot/repair decision (ADR-0016). Forced — injected
regardless of budget — but its cost counts toward package spend, so repair sees
less headroom. Repair candidates fold in any dependency they newly trigger, so
their marginal SAP-per-£ and incremental cost are truthful. The dependency never
competes in the optimiser pool. Returned selected includes the injected deps.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
VentilationOverlay (all-optional partial of SapVentilation) + EpcSimulation.
ventilation; apply_simulations folds it onto sap_ventilation, creating one when
the baseline lodged none. This is the surface a Measure Dependency (ventilation)
writes — whole-dwelling, no building part.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The cascade lumped a dwelling with two main heating systems into one:
`space_heating_fuel_monthly_kwh` hard-coded (203)=0 (a documented
scope-A placeholder) and the calculator's per-month fuel read only
main_1, so the full §8 space-heat demand billed against system 1's
efficiency. Simulated case 6 (one oil boiler feeding radiators 51% +
underfloor 49%) exposed it: main fuel ≈ demand/eff1 instead of the
worksheet's (211)+(213) per-system split.
Implements the SAP 10.2 §9a two-main model:
(204) = (202) × (1 − (203)) → system 1 share of total heat
(205) = (202) × (203) → system 2 share of total heat
(211)m = (98c)m × (204) × 100 / (206)
(213)m = (98c)m × (205) × 100 / (207)
(203) = the second system's lodged `main_heating_fraction`; (207) = its
own seasonal efficiency via the new per-detail `_main_heating_detail_
efficiency` (the core of `_main_heating_efficiency`, now reused for
system 2). Calculator `_solve_month` aggregates main_1 + main_2 into
`main_heating_fuel_kwh`. Cost (§10a 241), CO2 (§12 262) and PE (§13 276)
main_2 paths were already wired and now activate.
Site-notes gap also fixed: §14.1 Main Heating2 omits the "Fuel Type"
cell when the second system shares Main 1's fuel (case 6: one oil boiler,
two emitters). `_map_elmhurst_main_heating_2` now inherits Main 1's
resolved fuel as a fallback.
Blast radius: only dual-main certs. 0240 (2× oil code 130, identical
Eq-D1 efficiency) is unchanged — its split collapses to the lumped total.
Suite: 2355 passed, 1 skipped. New code: 0 pyright errors.
NOTE: case 6 is not yet fully pinnable end-to-end — its two systems have
DIFFERENT efficiencies (radiators 55°C → 79%, underfloor 35°C → 84%), a
flow-temperature boiler-efficiency adjustment not yet modelled, and its
dual-system auxiliary pumps ((230c)+(230d)=356) differ from the cascade.
Both are separate follow-on features; this slice is the §9a fuel split.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The Elmhurst extractor crashed parsing simulated-case-6's room-in-roof
window rows: the §11 "Location" cell "Roof of Room in Roof" wraps across
the layout prefix/suffix blocks and leaked into the glazing-type phrase
("Double between 2002 Roof of Room and 2021 in Roof" → UnmappedElmhurst-
Label). Fix (`_parse_window_from_anchors`): detect the roof-of-room
location tokens, strip them from the before/after blocks so the glazing
phrase reconstructs cleanly, and set location="Roof of Room".
Mapper: `_is_elmhurst_roof_window` gains a "Roof of Room" location branch
(highest-confidence rooflight signal, above the BP-roof-type / U>3.0
gates); `_ELMHURST_ROOF_WINDOW_U_BY_GLAZING` gains "Double between 2002
and 2021" → 2.30 (case 6 lodges the already-inclined roof-window U, so
the +0.30 inclination adjustment must not double-apply).
This is the site-notes mirror of S0380.198 (API window_wall_type=4):
both paths now route room-in-roof rooflights to (27a) at the inclined U.
Validated against the case-6 P960 worksheet at abs=1e-4:
(27) Windows = 22.7408 (cascade 22.7407)
(27a) Roof Windows = 13.0375 (cascade 13.0375, EXACT)
(31) ext area = 336.13
Case 6 is pinned only on the §3 window line refs (new standalone test,
not added to the section-pin `_FIXTURES`) because its DUAL main heating
(51% rads + 49% underfloor, oil) makes the §10/§12 per-system lines
non-comparable to SapResult's aggregated fields — documented in the
fixture module. Summary mirrored to Summary_001431_case6.pdf.
Suite: 2355 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of #1160 — the ADR-0016 truth step on top of the warm-start
knapsack. optimise_package(groups, scorer, baseline_epc, budget,
target_sap) -> OptimisedPackage:
warm-start optimise() (role-1 signal) → re-score the chosen package on
the real scorer (role-2 truth) → while the true SAP undershoots
target_sap and budget remains, greedy-add the untreated-group Option
with the best *marginal* SAP-per-£ (re-scored, not the role-1 signal),
re-score, repeat until the target is met, nothing positive-marginal is
affordable, or the budget is spent.
`Scorer` is a structural Protocol (PackageScorer satisfies it) so the
repair loop is tested with a stub scorer — no calculator, runs on ARM.
The key case: role-1 under-counts roof so the warm-start skips it, the
re-score undershoots, and repair adds roof back to hit the target. 3
repair tests + the 6 core tests; pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 1 of #1160. Recycles the GainOptimiser/CostOptimiser formulation
(≤1 Option per Recommendation, maximise SAP gain subject to budget) as a
clean typed DDD function — but as an exact pure-Python multiple-choice
knapsack rather than the legacy `mip` MILP, since mip's CBC backend does
not load on aarch64 (so the legacy solver path can't run / be tested
here). At retrofit scale the candidate space Π(|group|+1) is tiny, so
exhaustive enumeration is exact and instant; ADR-0016 only needs the
knapsack as a warm-start signal anyway (the truthful figure comes from
the whole-package re-score + repair, next slice).
`optimise(groups, budget) -> list[ScoredOption]`: maximise total gain,
tie-break toward lower cost, skip-per-group covers "select none". 6 tests
(budget-bound selection, ≤1/group, unconstrained, budget-too-small,
empty groups, partial-affordability); pyright strict clean.
Multi-phase remains descoped (ADR-0005) — single-phase optimiser.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Cert 0240's SAP residual (-1) and a chunk of its PE/CO2 was an API-mapper
bug: it flattened ALL windows into sap_windows, so the 6 windows lodged
with window_wall_type=4 — the RdSAP code for a roof window ("Roof of Room"
rooflight / inclined glazing) — were billed as vertical wall glazing on
worksheet (27) at U=2.0, instead of roof windows on (27a) at the Table 6e
Note 2 inclination-adjusted U (DG 2002+ vertical 2.0 + 0.30 = 2.30) with
45°-inclined solar gains.
window_wall_type=4 is the discriminator, NOT window_type=2 (certs 0390 /
7536 lodge window_type=2 on ordinary main-wall windows). Fix: partition
the 21.0.1 API window list into sap_windows (wall_type≠4) + sap_roof_
windows (wall_type=4); `_api_sap_roof_window` mirrors the site-notes
`_map_elmhurst_roof_window` (vertical U from the glazing Table-24 lookup +
0.30 inclination; 45° pitch; g/FF from the same lookup).
Validated against the simulated-case-6 worksheet, which bills these
identical windows on (27a) at U_eff 2.1062 (= 2.30 with the §3.2 R=0.04
curtain transform). The inclined solar gain dominates the higher U-loss,
RAISING the SAP:
- 0240: SAP cont 72.14 → 72.55 (resid -1 → +0 EXACT), PE +3.91 → +1.95,
CO2 +0.22 → +0.12
- 6035: 2 wall_type=4 rooflights — SAP still +0 exact, PE +1.84 → +1.37,
CO2 +0.01 → -0.0004
Blast radius is exactly these two certs (only golden fixtures with
wall_type=4). Suite: 2354 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Promotes user-simulated "case 5" (detached, sandstone-walled, room-in-roof
cousin of golden cert 0240) to an e2e worksheet fixture pinning the WHOLE
extractor → mapper → calculator pipeline at abs=1e-4 on all 11 Block-1
line refs. Its worksheet prints the exact RR-gable routing S0380.196
implements, validating that fix against ground truth:
Roof room Main Gable Wall 1 15.68 U=0.35 (29a) Exposed → walls @ main-wall U
Roof room Main remaining area 61.73 U=0.30 (30) A_RR shell − Σ gables
External roof Main 14.52 U=0.11 (30) loft residual
Roof room Main Gable Wall 2 15.68 U=0.25 (32) Party → party @ 0.25
gable area = 6.40 × 2.45 (§3.9.1 default RR storey height); A_RR remaining
= 12.5√(83.2/1.5) − 2×15.68 = 93.09 − 31.36 = 61.73 (RdSAP 10 §3.9.1(e)).
Confirms a DETACHED dwelling can lodge a Party RR gable (Table 4 p.22
row 2) — so my S0380.196 mapping (gable_wall_type 0=Party, 1=Exposed) is
correct; do not flip it.
Two extractor/mapper gaps surfaced and fixed (case 5 is the forcing test):
- Sandstone wall label "SS Stone: sandstone or limestone" had no
`_ELMHURST_WALL_CODE_TO_SAP10` entry (raised UnmappedElmhurstLabel).
Added "SS" → 2 (WALL_STONE_SANDSTONE), matching 0240's API
wall_construction=2 (cross-mapper parity).
- Roof "Insulation Thickness 400+ mm" was silently dropped: the four
thickness parsers used `.split()[0].isdigit()`, which rejects the
trailing "+" → None → u_roof fell back to the age-J default 0.16
instead of 0.11 (+1.09 W/K roof, the whole 0.12 SAP gap). Added
`_parse_thickness_mm` (strips to leading digits) and applied it at all
four sites (walls / alt-wall / roof / floor). The only existing fixture
with "400+ mm" (000565 Stud Wall) routes via the RIR regex, unaffected.
Result: case 5 cascade ≡ worksheet at 1e-4 on SAP/ECF/cost/CO2 + every
energy stream. Neither gap affects 0240 (its API path captures both the
sandstone code and "400mm+"); 0240's residual is therefore non-fabric.
Suite: 2353 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Slice 2 of #1157. The per-Property output of one Scenario's modelling
run, per ADR-0017.
- PlanMeasure: a selected Measure Option frozen with its installed Cost
and role-3 (final-package cascade) attributed MeasureImpact — the
output counterpart of a Recommendation's candidate Option.
- Plan: the selected Plan Measures + baseline/post-retrofit Scores.
Single-phase (ADR-0005); derives the persisted headline figures —
cost_of_works, contingency_cost, co2_savings_kg_per_yr (kg; the mapper
converts to tonnes), post_sap_continuous, and post_epc_rating (band
from the rounded SAP via Epc.from_sap_score).
1 unit test, pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Golden cert 6035's residual (SAP -2 / PE +19.16 / CO2 +0.42t) was a real
API-mapper bug, NOT lodged divergence (prior claim retracted).
The API `room_in_roof_type_1` block lodges gable walls by length only (no
height). The mapper carried just the scalar `gable_*_length_m`, and the
cascade's `_part_geometry` gable formula silently drops height-less gables
(needs a height) -> the whole A_RR shell `12.5√(A_RR_floor/1.5)` billed as
roof at U_RR=2.30 instead of the §3.9.1(e) residual
`A_RR − Σ gables`. On 6035 that over-counted roof by 22.78 m² × 2.30 =
+52.4 W/K (roof 130.73 -> 78.33, matching the site-notes case-4 replica at
1e-4 — cross-mapper parity).
RdSAP 10 §3.9.1(e) (PDF p.21): "the area of the room-in-roof gable walls
... is deducted from A_RR to give the residual roof area." Fix: route the
Type 1 gables through `detailed_surfaces` (gable area = L × the §3.9.1
default RR storey height 2.45 m; gable_wall_type 0=Party->gable_wall U=0.25,
1=Exposed->gable_wall_external "as common wall" per Table 4 p.22) so the
cascade's Detailed-RR residual fires — the same path the site-notes mapper
already uses.
Re-pinned golden residuals:
- 6035: SAP -2 -> +0 (exact), PE +19.16 -> +1.84, CO2 +0.42 -> +0.01
- 0240: same fix applies (2 Party gables L=6.4); PE +5.80 -> +3.91,
CO2 +0.32 -> +0.22, SAP integer unchanged
Also corrected the stale "gable_wall_type 0 = external" schema comment
(6035's Summary proves 0=Party, 1=Exposed) and added a strict
UnmappedApiCode raise for unknown gable_wall_type codes.
Suite: 2342 passed, 1 skipped. New code: 0 pyright errors.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated case-4 worksheet as e2e fixture `001431_6035` —
reproduces golden cert 6035's full floor geometry (Main ground-floor HLP
15.99 + first-floor HLP 8.32, the asymmetric upper storey) and 8 windows.
All 11 Block-1 line refs pin at abs=1e-4 against the worksheet (SAP 68,
ECF 2.2802, cost 937.2341, CO2 4682.3494, space 15745.3260, main fuel
18744.4357).
This is the 4th independent 1e-4 confirmation across the 6035 archetype
(sim cases 1-4). Case 4 matches 6035 on floors + window areas; the
residual ~50 kWh / £11 cascade delta vs 6035 is two lodged inputs only
(largest window orientation N vs S; meter type "Dual" vs API 2), not
calculator behaviour.
Conclusion: the cascade reproduces the spec engine exactly for 6035's
geometry, so 6035's +19 PE vs the lodged register is lodged-register
divergence (the gov.uk register's rounded value vs the spec-exact
worksheet), NOT a calculator gap. 6035 is a "pin-forever" lodged-only
cert. Bugs surfaced + fixed along the way: S0380.192 (Simplified-RR
remaining area) and S0380.193 (suspended-floor sealed rule).
2341 passed (+11), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Adds the user-simulated case-3 worksheet as e2e fixture `001431_rr8` —
Main + Extension + Simplified room-in-roof with 8 windows (≈14.15 m²,
reproducing golden cert 6035's glazing) and Main ground-floor HLP 15.99.
All 11 Block-1 line refs pin at abs=1e-4 against the worksheet (SAP 68,
cost 951.3425, CO2 4767.4862, space 16086.3557, main fuel 19150.4235,
HW 3307.2639, lighting 262.0885).
This is the third independent 1e-4 confirmation that the cascade
reproduces the spec engine for the 6035 archetype (after S0380.192
Simplified-RR + S0380.193 suspended-floor). It differs from 6035 in one
input only — the Main first-floor HLP (15.99 here vs 6035's 8.32) — so
6035's +19 PE vs the lodged register is lodged-register divergence, not
a calculator gap. A byte-identical 6035 replica (first-floor HLP 8.32)
would let 6035 itself be pinned directly to close that out.
2330 passed (+11), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes #1159 end-to-end with solid and suspended-floor before/after
cascade pins on cert 001431, both closing at delta 0.000000.
Adds floor_insulation_type_str to BuildingPartOverlay (the generic
field-fold applicator picks it up with no change) and has
recommend_floor_insulation set it to "Retro-fitted". Insulating an
as-built floor re-lodges its insulation as retro-fitted; the calculator
keys on this for a suspended timber floor's sealed/unsealed
determination (cert_to_inputs.py: "retro" + no U-value supplied →
sealed). Without it the suspended-floor cascade left a +1.40 SAP gap
(the floor stayed "unsealed", wrong U-value); with it the cascade
closes exactly. Solid floors are unaffected by the seal logic and stay
at delta 0; both Elmhurst after-certs lodge "Retro-fitted", so setting
it uniformly is faithful.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Completes #1158 end-to-end. recommend_loft_insulation now emits a
300 mm overlay (was 270 mm). The Elmhurst before/after re-lodgement of
the loft-insulation measure on cert 001431 lodges the after-cert at
300 mm roof insulation; pinning before→overlay→after requires the
overlay to match that depth — at 270 mm the cascade left a +0.173 SAP
residual, at 300 mm it closes at delta 0.000000 on SAP/CO2/PE.
Adds test_loft_overlay_reproduces_the_relodged_after and updates the
roof generator unit test's thickness assertion to 300.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Closes#1154 — the Package Scorer's Elmhurst cascade pin. Drives
recommend_cavity_wall on the parsed `before` Summary, scores its
Option's overlay through PackageScorer, and asserts delta 0 (abs<=1e-4
on SAP/CO2/PE) vs the calculator's score on the re-lodged `after`
Summary.
Key finding: the handover's stated parser gate (parse_site_notes_pdf
throwing 'Manufacturer' on cert 001431) does NOT block these pins. The
Elmhurst recommendation Summaries route cleanly through the same
ElmhurstSiteNotesExtractor + EpcPropertyDataMapper chain the worksheet
e2e fixtures use (_elmhurst_worksheet_001431.build_epc). The Textract
path's window bug is unrelated and unused here.
The before→after field change is exactly wall_insulation_type 4
(uninsulated) → 2 (filled cavity), which is precisely the overlay
recommend_cavity_wall emits; the cascade closes at delta 0.000000 on
all three metrics. Before/after Summaries mirrored into
tests/domain/modelling/fixtures/ so the pin does not depend on the
unstaged workspace.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
RdSAP 10 §5 (PDF p.29) "Floor infiltration (suspended timber ground
floor only)", age band A-E, splits on whether a floor U-value is
supplied:
a) [U-value supplied] if floor U-value < 0.5 → "sealed", (12) = 0.1
b) [no U-value supplied] retro-fitted insulation → "sealed" 0.1;
otherwise "unsealed", (12) = 0.2
`_has_suspended_timber_floor_per_spec` fed the cascade's COMPUTED default
U into rule (a), so an as-built/uninsulated suspended-timber floor whose
default U happens to be < 0.5 was marked "sealed" (0.1) where Elmhurst
uses "unsealed" (0.2). That dropped (18) infiltration 0.85 → 0.75, (25)
effective ACH, HTC, and understated space heating ~450 kWh.
Fix: gate rule (a) on `floor_u_value_known` — a computed default U is not
a supplied value, so it falls through to (b). Verified against the
cert 001431 sim-case-2 worksheet: floor "As built", U=0.43 (matches the
worksheet's (28a) 0.4300 exactly), (12)=0.2 unsealed. Golden cert 6035
(also a suspended uninsulated floor) is unaffected — its U=0.63 ≥ 0.5
already routed to unsealed.
Promotes sim case 2 to the e2e harness as `001431_rr` (Main + Extension
+ Simplified room-in-roof — the 6035 archetype). All 11 Block-1 line
refs pin at abs=1e-4, locking BOTH this fix and S0380.192 (Simplified-RR
remaining area) end-to-end: SAP 69, cost 920.5046, CO2 4566.7090, space
15269.8593, main fuel 18178.4039. 2319 passed (+11), 0 failed; pyright
net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_floor_insulation(epc, products) detects an uninsulated ground floor
(SapBuildingPart.floor_insulation_thickness blank/zero) and its construction
from floor_construction_type — 'Suspended timber' -> suspended_floor_insulation,
'Solid' -> solid_floor_insulation — emitting the matching single Option (a
floor is one construction, like a cavity wall) with the overlay
(floor_insulation_thickness = 100 mm) and a priced Cost (ground-floor area x
the Product's fully-loaded unit cost + contingency).
- building_geometry.ground_floor_area(epc, identifier): the lowest floor's
(floor == 0) area. Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains floor_insulation_thickness (generic Applicator
writes it unchanged). suspended (0.20) / solid (0.26) floor contingencies.
Progress on #1159 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and parser. Four behaviour tests (suspended / solid
/ none / cost) + geometry pin. pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_loft_insulation(epc, products) detects an uninsulated main loft
(SapBuildingPart.roof_insulation_thickness == 0) and emits a
Recommendation("Roof") with one loft_insulation Option carrying the overlay
(roof_insulation_thickness = 270 mm, the recommended top-up) and a priced
Cost (roof area x the Product's fully-loaded unit cost + contingency).
- building_geometry.roof_area(epc, identifier): the part's greatest
per-storey floor area (RdSAP 10 §3.8). Pinned 14.85 m^2 on 000490 MAIN.
- BuildingPartOverlay gains roof_insulation_thickness; the generic Overlay
Applicator writes it with NO change (validated by the tracer) — the
deep-module field-fold paying off.
- loft_insulation contingency (0.10) added.
Progress on #1158 (generator + geometry); end-to-end + Elmhurst pin pending
the orchestrator (#1157) and the parser fix. Four behaviour tests
(geometry pin; detect / none / cost). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
A Simplified room-in-roof (RdSAP 10 §3.9.1, PDF p.21) does NOT measure
its slope / flat-ceiling / stud-wall surfaces — the Elmhurst Summary
lodges placeholder Length/Height cells (a 40 m flat-ceiling height, a
32 m slope on a 4.65 m-wide gable). The spec instead derives one
timber-framed "remaining area" from the floor area:
A_RR = 12.5 × √(A_RR_floor / 1.5) §3.9.1(d)
A_RR_final = A_RR − ΣA_RR_gable/other §3.9.1(e)
The cascade already computes A_RR_final itself (heat_transmission.py:
`12.5 × √(A_RR_floor/1.5) − rr_walls_in_a_rr_area` residual), but only
when `detailed_surfaces` carries no roof-going kind (`has_roof_lodgement`
gate). `_map_elmhurst_rir_surface` emitted the placeholder slope/ceiling
rows as raw L×H for every assessment type, flipping that gate and billing
1024 m² + 160 m² of explicit roof area — a 7.5× fabric-heat-loss
explosion (cert 001431 sim case 2: SAP −14.6 vs worksheet 69, space
heating 114 378 vs ~15 000 kWh).
Fix: for a Simplified assessment, drop the roof-going surfaces in the
mapper so the cascade's residual formula fires. This matches how the API
path already (correctly) handles the same Simplified RR — scalar gable
fields, no roof-going detailed_surfaces (golden cert 6035) — and the
gables-only cert 000565. Detailed (§3.10) assessments still measure these
surfaces and keep them.
With the fix, sim case 2 total external area = 232.94 (worksheet exact),
roof 78.33 (was 2725.89), SAP 69.29 → worksheet integer 69. A small
residual (~450 kWh main fuel) remains — a separate fabric gap to walk
next. 2308 passed (+2), 0 failed; pyright net-zero.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
scoring.py adds the telescoping marginal cascade that serves two of the three
ADR-0016 scoring roles:
- marginal_impacts(scorer, baseline, overlays): applies overlays cumulatively
in order and reports each measure's marginal MeasureImpact (sap_points +
carbon/energy savings). Role 3 (final-package attribution) — the marginals
telescope EXACTLY to the whole-package total.
- independent_option_impacts(scorer, baseline, options): role 1 — scores each
Option's overlay independently vs baseline, scoring each DISTINCT overlay
once (Options sharing an overlay reuse the result). Approximate signal for
the optimiser; never surfaced as a measure's true impact.
Role 2 (whole-package re-score) is PackageScorer.score directly. Three
behaviour tests on the real Sap10Calculator / a counting stand-in (hand-built
EPD): single-overlay marginal == improvement-over-baseline; two-overlay
marginals telescope to the package total; per-Option dedup scores each
distinct overlay once. Closes#1156. pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
PackageScorer(calculator: SapCalculator).score(baseline, simulations) folds
the Simulation Overlays onto the baseline via the Overlay Applicator and
scores the throwaway EpcPropertyData on the injected deterministic SAP
calculator, returning Score(sap_continuous, co2_kg_per_yr,
primary_energy_kwh_per_yr). Depends on the SapCalculator abstraction, not a
concrete engine. This is the reusable scoring primitive (ADR-0016) — the
same call serves the optimiser's whole-package re-score and a future live
re-score of a user-assembled plan.
Two behaviour tests against the real Sap10Calculator on a hand-built EPD:
filling the main cavity improves SAP (right-directional through the real
physics); an empty package scores the unmodified baseline (pins the
SapResult->Score mapping). The Elmhurst before/after cascade PIN (#1154's
acceptance) lands once cert 001431 parses (external _extract_windows fix).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_cavity_wall now takes a ProductRepository and prices the Measure
Option: Cost(total = gross_heat_loss_wall_area(MAIN) x product.unit_cost_per_m2,
contingency_rate = product.contingency_rate). Detection is unchanged and runs
before pricing, so ineligible walls still return None without a catalogue hit.
Completes #1155 — the cavity-wall Recommendation Generator now detects an
uninsulated main cavity wall and emits a priced Option carrying the filled-
cavity overlay. Four behaviour tests (detection x3 + fully-loaded cost).
pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
domain/building_geometry.gross_heat_loss_wall_area(epc, identifier) sums
heat_loss_perimeter x room_height across a building part's storeys — the
heat-loss wall area (party walls excluded by construction), not total
wall area. Lives outside the calculator so Modelling cost quantities can
reuse it; the calculator computes the same quantity inline today and
should be DRY'd onto this later (coordinated with the calculator branch).
Pinned at 45.93 m^2 against the 000490 MAIN part. Toward #1155 cost
(behaviour 4). pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
recommend_cavity_wall(epc) detects an uninsulated main cavity wall
(wall_construction=4, wall_insulation_type=4) and emits a Recommendation
whose single Measure Option carries the Simulation Overlay setting MAIN
wall_insulation_type=2 (Table 6 'Filled cavity'; cf. domain/sap10_ml/
rdsap_uvalues.py u_wall). Returns None for already-insulated or
non-cavity main walls.
Recommendation/MeasureOption reshaped per design review: the target is
encoded in the Option's overlay (addresses a building part / window /
system), not a typed key on Recommendation — generalises to glazing and
heating without changing the type. CONTEXT partition wording generalised
to match.
Three behaviour tests (hand-built EPD, no PDF). Cost (behaviour 4 of
#1155) outstanding — needs net heat-loss wall area + ProductRepository.
WIP on #1155. pyright strict clean.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>