e312aae95d Generalise to a 'broken schema type' gate keyed on assessment_type
Per review (Khalim): lift the full-SAP detection out of the SAP-Schema-16.x
branch into a single top-level gate in from_api_response, and key it on the
gov-API's own assessment_type declaration rather than the structural
sap_opening_types proxy.

- _is_full_sap_assessment(data): assessment_type == "SAP" — the authoritative
  SAP-vs-RdSAP classification. Verified to separate the entire fixture corpus:
  every full-SAP schema (SAP-Schema-17.x/18.x + the broken LIG 16.x) is "SAP";
  every reduced cert (RdSAP-Schema-* and reduced SAP-Schema-16.x, incl.
  sap_16_0.json) is "RdSAP". data_type / sap_opening_types agree but are derived
  shape artifacts; assessment_type is the meaning.
- A cert that is full-SAP by assessment_type but whose schema_type LABEL is not a
  recognised full-SAP schema is a *broken schema type* (label disagrees with the
  assessment). _record_broken_schema_type logs it — visible, not silently
  rerouted — so unreliable labels surface and coverage grows as new mislabels
  appear. Generalises beyond 16.x to any future mislabel.
- _from_full_sap maps it via the full-SAP 17.1 mapper (real measured openings,
  no defaulting; only `tenure` defaulted). Correctly-labelled full-SAP certs keep
  their dedicated branches (one-mapper-per-schema convention); reduced certs are
  unchanged.

Tests: broken cert routed AND recorded; correctly-labelled full-SAP not recorded.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 15:39:16 +00:00
Jun-te Kim
5e0963593a Route full-SAP certs lodged under SAP-Schema-16.x to the full-SAP mapper
A full-SAP cert (assessment_type=SAP, the as-designed LIG-* new-builds) lodged
under a SAP-Schema-16.x version failed to map with:

  ValueError: RdSapSchema17_1: missing required field 'door_count'

— crashing the property's modelling_e2e subtask. 89 distinct properties in the
2026-06-24 run hit this; ~22 of every 30 sampled are this full-SAP shape.

Root cause: from_api_response dispatches on the schema_type STRING only, and the
SAP-Schema-16.x branch assumed a single shape — "reduced-field (RdSAP-shaped)" —
sending every 16.x cert through _normalize_sap_schema_16_x -> RdSapSchema17_1.
But the SAP-Schema-16.x name covers two structurally different certs:

  * reduced RdSAP (assessment_type=RdSAP): top-level door_count / glazed_area
    band / construction-code building parts.
  * full SAP    (assessment_type=SAP): measured shape — sap_opening_types +
    structured sap_building_parts carrying measured U-values and door/window
    OPENINGS, with NO top-level door_count (the door is an opening). These omit
    the reduced-only count fields, so the reduced normaliser failed loud on the
    first one it checks (door_count) — and 14 others behind it.

Force-fitting a full-SAP cert to the reduced RdSAP schema was the bug: the data
was never missing, it was being validated against the wrong schema.

Fix: discriminate on shape (_is_full_sap_cert: assessment_type=SAP AND
sap_opening_types present) and route full-SAP 16.x certs to the existing
full-SAP 17.1 mapper, which reads the real measured openings (the lodged
0.9x2.1m door -> door_count 1) — no reduced-field defaulting. The only field the
16.x full-SAP shape omits that SapSchema17_1 needs is `tenure` (register
metadata, no SAP effect), defaulted. Reduced 16.x certs (assessment_type=RdSAP,
no opening types) are untouched — all pinned reduced 16.x fixtures stay on the
RdSAP path.

Regression test pins a real full-SAP-16.0 cert (0293-...-8795, lodged 83) mapping
via the full-SAP path + the reduced 16.2 cert staying on the RdSAP path.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 15:16:51 +00:00
Daniel Roth
f6e5e11d88
Merge pull request #1300 from Hestia-Homes/feature/notnullviolation-optional-fields-21-0-1
fix: coalesce omitted 21.0.1 optional count fields to 0 to prevent NotNullViolation on persist
2026-06-24 14:36:04 +01:00
Daniel Roth
514cfb5f9b
Merge pull request #1301 from Hestia-Homes/fix/prediction-main-bearing-template
Prefer a MAIN-bearing prediction template so EPC-less dwellings predict
2026-06-24 14:35:03 +01:00
Daniel Roth
10c975b1ae Fix test asserting None for cfl_fixed_lighting_bulbs_count on 21.0.1 cert 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:31:02 +00:00
Jun-te Kim
e2915d8042 Prefer a MAIN-bearing prediction template so EPC-less dwellings predict 🟩
A predicted EPC is seeded by deep-copying one representative neighbour's
structure. _template chose the member whose floor area was closest to the
cohort median, ignoring building-part labels. When that member's only part
was lodged with a null identifier (mapped to OTHER), the prediction had no
MAIN part and the modelling_e2e handler rejected it as "not predictable" —
discarding an otherwise-rich same-type cohort.

Restrict the template to MAIN-bearing members (median still over the whole
cohort); fall back to closest-on-size only when none are MAIN-bearing, so an
all-unlabelled cohort is left for the handler's MAIN-part guard to reject
rather than silently relabelling real data.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 13:20:43 +00:00
Daniel Roth
40a079e464 21.0.1 mapper coalesces omitted led_fixed_lighting_bulbs_count to 0 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:19:10 +00:00
Daniel Roth
e906bbecf8 21.0.1 mapper coalesces omitted led_fixed_lighting_bulbs_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:17:19 +00:00
Jun-te Kim
abb822c1c7 Prefer a MAIN-bearing prediction template so EPC-less dwellings predict 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 13:16:54 +00:00
Daniel Roth
71269637ef 21.0.1 mapper coalesces omitted cfl_fixed_lighting_bulbs_count to 0 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:16:29 +00:00
Daniel Roth
d36fa2b5cd 21.0.1 mapper coalesces omitted cfl_fixed_lighting_bulbs_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:15:37 +00:00
Daniel Roth
a01a940df2 21.0.1 mapper coalesces omitted open_chimneys_count to 0 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:14:36 +00:00
Daniel Roth
6efbd4649d 21.0.1 mapper coalesces omitted open_chimneys_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:13:43 +00:00
Jun-te Kim
fc7cfc70e8
Merge pull request #1295 from Hestia-Homes/fix/fuel-code-39-electricity
Map fuel code 39 (electricity, any tariff) to standard electricity
2026-06-24 12:37:25 +01:00
Daniel Roth
ecd9a5c622
Merge pull request #1296 from Hestia-Homes/feature/e2e-subtasks
Separate subtask for each property ID when e2e modelling is triggered
2026-06-24 12:36:12 +01:00
KhalimCK
8c00b586b5
Merge pull request #1293 from Hestia-Homes/feature/e2e-runs
Feature/e2e runs
2026-06-24 12:36:04 +01:00
Jun-te Kim
2498192b72 docs(fuel): TODO to price code-39 electricity by actual tariff (Khalim)
Note that code 39 "any tariff" currently collapses to the standard electricity
rate; future work should resolve it to the dwelling's actual tariff (off-peak vs
standard) so off-peak electric heating prices correctly. Comment-only.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:35:31 +00:00
Daniel Roth
6a5a2c39d3 remove smoke tests from gh workflows 2026-06-24 11:35:30 +00:00
Jun-te Kim
782c686969 Map fuel code 39 (electricity, any tariff) to standard electricity
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).

Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.

Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).

Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:20:32 +00:00
Daniel Roth
d06e92cd75 task_handler: fix pyright unknown-type errors in pass_task_orchestrator branch 🟪
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:15:58 +00:00
Daniel Roth
e1bc5360f2 skipped cohort certs are logged without failing the coordinator SubTask 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:11:19 +00:00
Daniel Roth
fc2732550c skipped cohort certs are logged without failing the coordinator SubTask 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:09:30 +00:00
Khalim Conn-Kowlessar
f6ec96fbcd Merge remote-tracking branch 'origin/main' into feature/e2e-runs
# Conflicts:
#	domain/sap10_calculator/tables/table_12a.py
2026-06-24 11:07:42 +00:00
Daniel Roth
c2a84d3ee8 per-property failure fails child SubTask without raising from handler 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:07:34 +00:00
Daniel Roth
39f028f03a per-property failure fails child SubTask without raising from handler 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:04:29 +00:00
KhalimCK
f7f74ea72b
Merge pull request #1288 from Hestia-Homes/feature/per-cert-mapper-validation
Feature/per cert mapper validation
2026-06-24 12:04:00 +01:00
Jun-te Kim
46fc8f338c
Merge pull request #1289 from Hestia-Homes/fix/solar-missing-max-array-panels
Treat solar block without array sizing as no-solar (fix KeyError maxArrayPanelsCount, 2 e2e failures)
2026-06-24 11:59:57 +01:00
Jun-te Kim
e9a8ad9cd9
Merge pull request #1290 from Hestia-Homes/fix/building-part-int-identifier
Tolerate non-string building-part identifier (fix TypeError, cohort cert)
2026-06-24 11:59:31 +01:00
Jun-te Kim
170fd1bf71
Merge pull request #1291 from Hestia-Homes/fix/full-sap-has-hot-water-cylinder
Fall back to nested has_hot_water_cylinder for full-SAP certs (cohort cert)
2026-06-24 11:59:03 +01:00
Jun-te Kim
e4a79648ab
Merge pull request #1292 from Hestia-Homes/fix/sap-opening-type-6
Map full-SAP opening-type 6 (rooflight) as a roof window (5 cohort certs)
2026-06-24 11:58:53 +01:00
Daniel Roth
91c2d8a8fd handler creates one child SubTask per property ID in the batch 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:58:47 +00:00
Daniel Roth
2d2abc016b handler creates one child SubTask per property ID in the batch 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:56:13 +00:00
Jun-te Kim
41ebf01969
Merge pull request #1287 from Hestia-Homes/fix/dual-fuel-billing-carrier
Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode fuel_code 10, 10 e2e failures)
2026-06-24 11:49:18 +01:00
Daniel Roth
35a794563a task_handler passes orchestrator and task_id to wrapped function when flag is true 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:48:40 +00:00
Jun-te Kim
789103af27 Map full-SAP opening-type 6 (rooflight) as a roof window
5 modelling_e2e cohort certs (full-SAP 19.1.0) were skipped with
"unmapped API sap_opening_type code: 6". Code 6 is "Ext Rooflight"; SAP 10.2
treats roof windows and rooflights as the same inclined-glazing family.

Fix: add 6 to the known opening-type taxonomy and route it onto the roof-window
path (`sap_roof_windows`) alongside code 5, via a `_SAP_ROOF_WINDOW_TYPES`
{5, 6} set. Genuinely-unknown codes (e.g. 99) still raise.

Cert 9878-3908-6309-6714-8200 now maps + calculates (sap 81). Regression test:
a type-6 opening maps onto sap_roof_windows.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:47:33 +00:00
Daniel Roth
3a66819a86 task_handler passes orchestrator and task_id to wrapped function when flag is true 🟥 2026-06-24 10:47:05 +00:00
Khalim Conn-Kowlessar
db3bf00602 fix(synthesis): Coherent Heating System — synthesisers own the whole boundary
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.

Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):

- Override overlay *completes* the partial system the landlord named. Companion
  fields are now DERIVED from the SAP code, not hand-attached per archetype: the
  off-peak meter from the calculator's single off-peak classification (new
  OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
  charge control defaults to the conservative manual control (Table 4e 2401). So
  adding a heating archetype is just adding its code — companions can't be
  forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
  sap_heating cluster — the donor is already coherent.

Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.

Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:46:11 +00:00
Jun-te Kim
18063a2d7f Fall back to nested has_hot_water_cylinder for full-SAP certs
A SAP-Schema-17.0 full-SAP cohort cert (8265-7433-3220-9736-7902) omits the
top-level `has_hot_water_cylinder` and lodges it only under `sap_heating`. The
required top-level field on SapSchema17_1 made `from_dict` raise and skip the
cert.

Fix: make the top-level field Optional, and have the full-SAP mapper
(`from_sap_schema_17_1`, also used by 17.0/18.0.0 via delegation) fall back to
`sap_heating.has_hot_water_cylinder`. RdSAP mappers are unchanged (they keep the
top-level required field; their SapHeating has no such attribute).

Cert now maps + calculates (sap 76). Regression tests for the nested true/false
fallback.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:43:18 +00:00
Jun-te Kim
6d98ecf375 Tolerate non-string building-part identifier (fix TypeError)
A SAP-16.x cohort cert (9258-4062-7265-2844-7954) lodges a bare int building-
part identifier (the second part as `1` after "Main Dwelling").
`BuildingPartIdentifier.from_api_string` regex-matched it assuming a string and
raised "TypeError: expected string or bytes-like object, got 'int'", failing the
whole property.

Fix: guard the match on `isinstance(api_identifier, str)` so a non-string
identifier falls to OTHER, matching the documented "anything unrecognised ->
OTHER" contract. The baseline SAP fabric sums all building parts regardless of
identifier, so OTHER is SAP-neutral; the identifier only labels parts for
measure targeting. Fixes every mapper (all route through from_api_string).

Cert now maps + calculates (sap 63). Regression test added.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:33:23 +00:00
Jun-te Kim
eecea8301e
Merge pull request #1286 from Hestia-Homes/fix/predicted-baseline-rhi-fallback
Fall back to computed kWh for predicted-EPC baselines (fix 16 e2e failures)
2026-06-24 11:26:33 +01:00
Jun-te Kim
79f89d872e Treat solar block without array sizing as no-solar (fix KeyError)
2 modelling_e2e properties failed with KeyError: 'maxArrayPanelsCount'.

Google returns a `solarPotential` block with no array-level sizing fields
(`maxArrayPanelsCount` / `panelCapacityWatts`) for buildings with no usable
solar estimate. `SolarPotential.from_building_insights` hard-indexed those keys
and crashed the whole property.

Fix: the projection now returns Optional and yields None when those fields are
absent — the established "no solar potential" outcome (the orchestrator and
recommendation path already type it Optional and skip solar on None). Existing
callers (`_solar_potential_for`, harness) already assign to Optional.

Regression test + `assert is not None` narrowing on the valid-fixture tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:22:06 +00:00
Jun-te Kim
d97b8e87a4 Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode 10)
10 modelling_e2e properties failed with "unmapped SAP code in fuel_code: 10":
the billing layer (`sap_code_to_fuel`) had no carrier for Table-32 code 10
(dual fuel, mineral + wood) and raised rather than guess one.

SAP 10.2 treats dual fuel as its OWN fuel (its own Table-12 factors), so model
it as its own billing carrier rather than collapsing onto wood or coal:

- New `Fuel.DUAL_FUEL_MINERAL_AND_WOOD`.
- `_CODE_TO_FUEL[10]` -> that carrier.
- Fuel Rates snapshot prices it at 7.69 p/kWh — the midpoint of the COAL proxy
  (7.13) and WOOD_LOGS (8.25). This mirrors SAP's own construction: Table-32
  dual fuel (3.99) ~= midpoint of house coal (3.67) and wood logs (4.23).
  Marked `derived` with a documented _note/_gap/_assumption (like the COAL and
  HEAT_NETWORK proxies), since there is no retail blend price.

A dedicated carrier + rate (vs a one-line map to an existing carrier) keeps the
fuel identity faithful to SAP and avoids mispricing dual fuel as pure wood/coal.

Tests: code 10 -> DUAL_FUEL carrier; snapshot prices it at 7.69; grid-export
codes (36/60) still raise (the genuine no-carrier case).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:07:57 +00:00
Khalim Conn-Kowlessar
80985865a2 Revert "guard(modelling_e2e): quarantine predicted Properties the calculator mis-scores"
This reverts commit 0c70280dea.
2026-06-24 09:33:54 +00:00
Khalim Conn-Kowlessar
0c70280dea guard(modelling_e2e): quarantine predicted Properties the calculator mis-scores
TEMPORARY guard (remove once the SAP calculator's oil-heating under-score is
fixed): a predicted oil-boiler picture scores SAP 13/G against its own
synthesised recorded SAP of 50/E, so the optimiser overshoots goal C all the
way to band A and publishes nonsense.

A predicted EpcPropertyData carries its recorded SAP (energy_rating_current).
When the calculator baseline diverges from it by more than ~one band (20 SAP
points), withhold the Plan: raise inside the per-property loop so the existing
failure isolation drops just that property into `failures` and fails the
subtask, while every other property still models and persists. Lodged
Properties are untouched — they have a real recorded cert and the Rebaseliner
already owns this check.

Verified end-to-end against property 713406 (UPRN 100061849247): baseline 13.2
vs recorded 50 -> quarantined, no Plan written.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:24 +00:00
Khalim Conn-Kowlessar
4e2f2bdcc7 test(worksheet): pin simulated case 50 — MVHR + dual-immersion all-electric
Adds the mapper-driven e2e cascade pin for "simulated case 50" (000565 semi,
electric storage main SAP 402 + portable electric secondary + MVHR + whc-903
DUAL electric immersion + 160 L cylinder, Economy-7). Routes the Summary PDF
through extractor + mapper + calculator like the other 000565 fixtures.

Locks in two off-peak fixes this case ground-truthed:
- the Table 13 HW high/low split applied to CO2/PE (commit 39ae2cf0), and
- the Table 12a Grid 2 MVHR fan fraction 0.71/0.58 (commit cd5113ab).

All 11 SAP-result fields reconcile to the U985 worksheet EXACTLY, including
the (272) rating CO2 2397.1237 — SAP 38.8426 (=39), cost £1317.0116, water
1668.0788 kWh, fans 315.6384 kWh.

Summary mirrored to the tracked fixtures dir so the test doesn't depend on
the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:16 +00:00
Khalim Conn-Kowlessar
39ae2cf0c2 fix(water-heating): split whc-903 immersion HW CO2/PE on off-peak tariffs
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.

That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.

Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.

Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).

Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:05:21 +00:00
Jun-te Kim
6679d8c621 Fall back to computed kWh for predicted-EPC baselines (no lodged RHI)
16 modelling_e2e properties failed with "Effective EPC is missing
renewable_heat_incentive; cannot read baseline space-heating / hot-water kWh".

Baseline runs for predicted properties too (ADR-0031), reading space/water-
heating kWh off the EPC's lodged RHI block. Predicted EPCs deep-copy a neighbour
template that may carry no RHI, so `_require_rhi` hard-failed the whole subtask.

Fix: when the EPC has no RHI, fall back to the property's OWN computed figures
from the scored SapResult (space_heating_kwh_per_yr / hot_water_kwh_per_yr) —
more representative than a neighbour's lodged numbers. Only when there is also no
SapResult (the rebaseliner scored nothing) is there genuinely no demand to
record, and we still fail noisily. Lodged certs are unchanged (RHI still wins).

Regression tests: fallback-to-computed, and the no-RHI/no-result raise.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:58:24 +00:00
Khalim Conn-Kowlessar
f3e3494bf7 test(worksheet): pin simulated case 52 — regular gas boiler + cylinder
Adds the mapper-driven e2e cascade pin for "simulated case 52" (000565
semi + regular non-combi mains-gas boiler SAP 102 + 160 L foam cylinder
heated from the main, no cylinder stat, uninsulated primary pipework,
standard tariff). Routes the Summary PDF through extractor + mapper +
calculator like the other 000565 / 001431_case* fixtures.

This closes the last untested branch of the cylinder/water chain: the
SAP 10.2 §4 cylinder storage loss (Table 2/2a/2b lines 51-55) + the
Table 3 PRIMARY circuit loss (59, uninsulated pipework + no stat) that
combi/immersion fixtures don't reach. All 11 SAP-result fields reconcile
to the U985 worksheet EXACTLY with no calculator change — SAP 57.2904
(=57), cost £911.1973, water 3929.7635 kWh — confirming the cylinder-loss
derivation is correct.

Summary mirrored to the tracked fixtures dir so the test doesn't depend
on the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:50:19 +00:00
Jun-te Kim
eefeccf0bc
Merge pull request #1283 from Hestia-Homes/fix/rdsap-21-0-0-cohort-cert-skips
Align RdSAP 21.0.0 schema optionality with 21.0.1 (unblock ~35 cohort certs)
2026-06-24 09:43:17 +01:00
Khalim Conn-Kowlessar
01bc93ed33 Merge remote-tracking branch 'origin/main' into feature/e2e-runs 2026-06-24 08:39:31 +00:00