Commit graph

6999 commits

Author SHA1 Message Date
Daniel Roth
e906bbecf8 21.0.1 mapper coalesces omitted led_fixed_lighting_bulbs_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:17:19 +00:00
Daniel Roth
71269637ef 21.0.1 mapper coalesces omitted cfl_fixed_lighting_bulbs_count to 0 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:16:29 +00:00
Daniel Roth
d36fa2b5cd 21.0.1 mapper coalesces omitted cfl_fixed_lighting_bulbs_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:15:37 +00:00
Daniel Roth
a01a940df2 21.0.1 mapper coalesces omitted open_chimneys_count to 0 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:14:36 +00:00
Daniel Roth
6efbd4649d 21.0.1 mapper coalesces omitted open_chimneys_count to 0 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 13:13:43 +00:00
Jun-te Kim
fc7cfc70e8
Merge pull request #1295 from Hestia-Homes/fix/fuel-code-39-electricity
Map fuel code 39 (electricity, any tariff) to standard electricity
2026-06-24 12:37:25 +01:00
Daniel Roth
ecd9a5c622
Merge pull request #1296 from Hestia-Homes/feature/e2e-subtasks
Separate subtask for each property ID when e2e modelling is triggered
2026-06-24 12:36:12 +01:00
KhalimCK
8c00b586b5
Merge pull request #1293 from Hestia-Homes/feature/e2e-runs
Feature/e2e runs
2026-06-24 12:36:04 +01:00
Jun-te Kim
2498192b72 docs(fuel): TODO to price code-39 electricity by actual tariff (Khalim)
Note that code 39 "any tariff" currently collapses to the standard electricity
rate; future work should resolve it to the dwelling's actual tariff (off-peak vs
standard) so off-peak electric heating prices correctly. Comment-only.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:35:31 +00:00
Daniel Roth
6a5a2c39d3 remove smoke tests from gh workflows 2026-06-24 11:35:30 +00:00
Jun-te Kim
782c686969 Map fuel code 39 (electricity, any tariff) to standard electricity
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).

Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.

Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).

Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:20:32 +00:00
Daniel Roth
d06e92cd75 task_handler: fix pyright unknown-type errors in pass_task_orchestrator branch 🟪
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:15:58 +00:00
Daniel Roth
e1bc5360f2 skipped cohort certs are logged without failing the coordinator SubTask 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:11:19 +00:00
Daniel Roth
fc2732550c skipped cohort certs are logged without failing the coordinator SubTask 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:09:30 +00:00
Khalim Conn-Kowlessar
f6ec96fbcd Merge remote-tracking branch 'origin/main' into feature/e2e-runs
# Conflicts:
#	domain/sap10_calculator/tables/table_12a.py
2026-06-24 11:07:42 +00:00
Daniel Roth
c2a84d3ee8 per-property failure fails child SubTask without raising from handler 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:07:34 +00:00
Daniel Roth
39f028f03a per-property failure fails child SubTask without raising from handler 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 11:04:29 +00:00
KhalimCK
f7f74ea72b
Merge pull request #1288 from Hestia-Homes/feature/per-cert-mapper-validation
Feature/per cert mapper validation
2026-06-24 12:04:00 +01:00
Jun-te Kim
46fc8f338c
Merge pull request #1289 from Hestia-Homes/fix/solar-missing-max-array-panels
Treat solar block without array sizing as no-solar (fix KeyError maxArrayPanelsCount, 2 e2e failures)
2026-06-24 11:59:57 +01:00
Jun-te Kim
e9a8ad9cd9
Merge pull request #1290 from Hestia-Homes/fix/building-part-int-identifier
Tolerate non-string building-part identifier (fix TypeError, cohort cert)
2026-06-24 11:59:31 +01:00
Jun-te Kim
170fd1bf71
Merge pull request #1291 from Hestia-Homes/fix/full-sap-has-hot-water-cylinder
Fall back to nested has_hot_water_cylinder for full-SAP certs (cohort cert)
2026-06-24 11:59:03 +01:00
Jun-te Kim
e4a79648ab
Merge pull request #1292 from Hestia-Homes/fix/sap-opening-type-6
Map full-SAP opening-type 6 (rooflight) as a roof window (5 cohort certs)
2026-06-24 11:58:53 +01:00
Daniel Roth
91c2d8a8fd handler creates one child SubTask per property ID in the batch 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:58:47 +00:00
Daniel Roth
2d2abc016b handler creates one child SubTask per property ID in the batch 🟥
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:56:13 +00:00
Jun-te Kim
41ebf01969
Merge pull request #1287 from Hestia-Homes/fix/dual-fuel-billing-carrier
Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode fuel_code 10, 10 e2e failures)
2026-06-24 11:49:18 +01:00
Daniel Roth
35a794563a task_handler passes orchestrator and task_id to wrapped function when flag is true 🟩
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-06-24 10:48:40 +00:00
Jun-te Kim
789103af27 Map full-SAP opening-type 6 (rooflight) as a roof window
5 modelling_e2e cohort certs (full-SAP 19.1.0) were skipped with
"unmapped API sap_opening_type code: 6". Code 6 is "Ext Rooflight"; SAP 10.2
treats roof windows and rooflights as the same inclined-glazing family.

Fix: add 6 to the known opening-type taxonomy and route it onto the roof-window
path (`sap_roof_windows`) alongside code 5, via a `_SAP_ROOF_WINDOW_TYPES`
{5, 6} set. Genuinely-unknown codes (e.g. 99) still raise.

Cert 9878-3908-6309-6714-8200 now maps + calculates (sap 81). Regression test:
a type-6 opening maps onto sap_roof_windows.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:47:33 +00:00
Daniel Roth
3a66819a86 task_handler passes orchestrator and task_id to wrapped function when flag is true 🟥 2026-06-24 10:47:05 +00:00
Khalim Conn-Kowlessar
db3bf00602 fix(synthesis): Coherent Heating System — synthesisers own the whole boundary
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.

Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):

- Override overlay *completes* the partial system the landlord named. Companion
  fields are now DERIVED from the SAP code, not hand-attached per archetype: the
  off-peak meter from the calculator's single off-peak classification (new
  OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
  charge control defaults to the conservative manual control (Table 4e 2401). So
  adding a heating archetype is just adding its code — companions can't be
  forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
  sap_heating cluster — the donor is already coherent.

Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.

Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:46:11 +00:00
Jun-te Kim
18063a2d7f Fall back to nested has_hot_water_cylinder for full-SAP certs
A SAP-Schema-17.0 full-SAP cohort cert (8265-7433-3220-9736-7902) omits the
top-level `has_hot_water_cylinder` and lodges it only under `sap_heating`. The
required top-level field on SapSchema17_1 made `from_dict` raise and skip the
cert.

Fix: make the top-level field Optional, and have the full-SAP mapper
(`from_sap_schema_17_1`, also used by 17.0/18.0.0 via delegation) fall back to
`sap_heating.has_hot_water_cylinder`. RdSAP mappers are unchanged (they keep the
top-level required field; their SapHeating has no such attribute).

Cert now maps + calculates (sap 76). Regression tests for the nested true/false
fallback.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:43:18 +00:00
Jun-te Kim
6d98ecf375 Tolerate non-string building-part identifier (fix TypeError)
A SAP-16.x cohort cert (9258-4062-7265-2844-7954) lodges a bare int building-
part identifier (the second part as `1` after "Main Dwelling").
`BuildingPartIdentifier.from_api_string` regex-matched it assuming a string and
raised "TypeError: expected string or bytes-like object, got 'int'", failing the
whole property.

Fix: guard the match on `isinstance(api_identifier, str)` so a non-string
identifier falls to OTHER, matching the documented "anything unrecognised ->
OTHER" contract. The baseline SAP fabric sums all building parts regardless of
identifier, so OTHER is SAP-neutral; the identifier only labels parts for
measure targeting. Fixes every mapper (all route through from_api_string).

Cert now maps + calculates (sap 63). Regression test added.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:33:23 +00:00
Jun-te Kim
eecea8301e
Merge pull request #1286 from Hestia-Homes/fix/predicted-baseline-rhi-fallback
Fall back to computed kWh for predicted-EPC baselines (fix 16 e2e failures)
2026-06-24 11:26:33 +01:00
Jun-te Kim
79f89d872e Treat solar block without array sizing as no-solar (fix KeyError)
2 modelling_e2e properties failed with KeyError: 'maxArrayPanelsCount'.

Google returns a `solarPotential` block with no array-level sizing fields
(`maxArrayPanelsCount` / `panelCapacityWatts`) for buildings with no usable
solar estimate. `SolarPotential.from_building_insights` hard-indexed those keys
and crashed the whole property.

Fix: the projection now returns Optional and yields None when those fields are
absent — the established "no solar potential" outcome (the orchestrator and
recommendation path already type it Optional and skip solar on None). Existing
callers (`_solar_potential_for`, harness) already assign to Optional.

Regression test + `assert is not None` narrowing on the valid-fixture tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:22:06 +00:00
Jun-te Kim
d97b8e87a4 Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode 10)
10 modelling_e2e properties failed with "unmapped SAP code in fuel_code: 10":
the billing layer (`sap_code_to_fuel`) had no carrier for Table-32 code 10
(dual fuel, mineral + wood) and raised rather than guess one.

SAP 10.2 treats dual fuel as its OWN fuel (its own Table-12 factors), so model
it as its own billing carrier rather than collapsing onto wood or coal:

- New `Fuel.DUAL_FUEL_MINERAL_AND_WOOD`.
- `_CODE_TO_FUEL[10]` -> that carrier.
- Fuel Rates snapshot prices it at 7.69 p/kWh — the midpoint of the COAL proxy
  (7.13) and WOOD_LOGS (8.25). This mirrors SAP's own construction: Table-32
  dual fuel (3.99) ~= midpoint of house coal (3.67) and wood logs (4.23).
  Marked `derived` with a documented _note/_gap/_assumption (like the COAL and
  HEAT_NETWORK proxies), since there is no retail blend price.

A dedicated carrier + rate (vs a one-line map to an existing carrier) keeps the
fuel identity faithful to SAP and avoids mispricing dual fuel as pure wood/coal.

Tests: code 10 -> DUAL_FUEL carrier; snapshot prices it at 7.69; grid-export
codes (36/60) still raise (the genuine no-carrier case).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:07:57 +00:00
Khalim Conn-Kowlessar
80985865a2 Revert "guard(modelling_e2e): quarantine predicted Properties the calculator mis-scores"
This reverts commit 0c70280dea.
2026-06-24 09:33:54 +00:00
Khalim Conn-Kowlessar
0c70280dea guard(modelling_e2e): quarantine predicted Properties the calculator mis-scores
TEMPORARY guard (remove once the SAP calculator's oil-heating under-score is
fixed): a predicted oil-boiler picture scores SAP 13/G against its own
synthesised recorded SAP of 50/E, so the optimiser overshoots goal C all the
way to band A and publishes nonsense.

A predicted EpcPropertyData carries its recorded SAP (energy_rating_current).
When the calculator baseline diverges from it by more than ~one band (20 SAP
points), withhold the Plan: raise inside the per-property loop so the existing
failure isolation drops just that property into `failures` and fails the
subtask, while every other property still models and persists. Lodged
Properties are untouched — they have a real recorded cert and the Rebaseliner
already owns this check.

Verified end-to-end against property 713406 (UPRN 100061849247): baseline 13.2
vs recorded 50 -> quarantined, no Plan written.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:24 +00:00
Khalim Conn-Kowlessar
4e2f2bdcc7 test(worksheet): pin simulated case 50 — MVHR + dual-immersion all-electric
Adds the mapper-driven e2e cascade pin for "simulated case 50" (000565 semi,
electric storage main SAP 402 + portable electric secondary + MVHR + whc-903
DUAL electric immersion + 160 L cylinder, Economy-7). Routes the Summary PDF
through extractor + mapper + calculator like the other 000565 fixtures.

Locks in two off-peak fixes this case ground-truthed:
- the Table 13 HW high/low split applied to CO2/PE (commit 39ae2cf0), and
- the Table 12a Grid 2 MVHR fan fraction 0.71/0.58 (commit cd5113ab).

All 11 SAP-result fields reconcile to the U985 worksheet EXACTLY, including
the (272) rating CO2 2397.1237 — SAP 38.8426 (=39), cost £1317.0116, water
1668.0788 kWh, fans 315.6384 kWh.

Summary mirrored to the tracked fixtures dir so the test doesn't depend on
the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:16 +00:00
Khalim Conn-Kowlessar
39ae2cf0c2 fix(water-heating): split whc-903 immersion HW CO2/PE on off-peak tariffs
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.

That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.

Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.

Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).

Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:05:21 +00:00
Jun-te Kim
6679d8c621 Fall back to computed kWh for predicted-EPC baselines (no lodged RHI)
16 modelling_e2e properties failed with "Effective EPC is missing
renewable_heat_incentive; cannot read baseline space-heating / hot-water kWh".

Baseline runs for predicted properties too (ADR-0031), reading space/water-
heating kWh off the EPC's lodged RHI block. Predicted EPCs deep-copy a neighbour
template that may carry no RHI, so `_require_rhi` hard-failed the whole subtask.

Fix: when the EPC has no RHI, fall back to the property's OWN computed figures
from the scored SapResult (space_heating_kwh_per_yr / hot_water_kwh_per_yr) —
more representative than a neighbour's lodged numbers. Only when there is also no
SapResult (the rebaseliner scored nothing) is there genuinely no demand to
record, and we still fail noisily. Lodged certs are unchanged (RHI still wins).

Regression tests: fallback-to-computed, and the no-RHI/no-result raise.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:58:24 +00:00
Khalim Conn-Kowlessar
f3e3494bf7 test(worksheet): pin simulated case 52 — regular gas boiler + cylinder
Adds the mapper-driven e2e cascade pin for "simulated case 52" (000565
semi + regular non-combi mains-gas boiler SAP 102 + 160 L foam cylinder
heated from the main, no cylinder stat, uninsulated primary pipework,
standard tariff). Routes the Summary PDF through extractor + mapper +
calculator like the other 000565 / 001431_case* fixtures.

This closes the last untested branch of the cylinder/water chain: the
SAP 10.2 §4 cylinder storage loss (Table 2/2a/2b lines 51-55) + the
Table 3 PRIMARY circuit loss (59, uninsulated pipework + no stat) that
combi/immersion fixtures don't reach. All 11 SAP-result fields reconcile
to the U985 worksheet EXACTLY with no calculator change — SAP 57.2904
(=57), cost £911.1973, water 3929.7635 kWh — confirming the cylinder-loss
derivation is correct.

Summary mirrored to the tracked fixtures dir so the test doesn't depend
on the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:50:19 +00:00
Jun-te Kim
eefeccf0bc
Merge pull request #1283 from Hestia-Homes/fix/rdsap-21-0-0-cohort-cert-skips
Align RdSAP 21.0.0 schema optionality with 21.0.1 (unblock ~35 cohort certs)
2026-06-24 09:43:17 +01:00
Khalim Conn-Kowlessar
01bc93ed33 Merge remote-tracking branch 'origin/main' into feature/e2e-runs 2026-06-24 08:39:31 +00:00
Jun-te Kim
7489e5ac89 Scope 21.0.0 widening to fields the skipped certs actually omit
Review follow-up (Khalim): the first pass made far more optional than needed —
notably the whole SapBuildingPart block — and a buggy 21.0.0↔21.0.1 diff also
MISSED open_chimneys_count / cfl_/led_fixed_lighting_bulbs_count / suggested_
improvements, so the original change actually mapped only 3 of the 33 skipped
certs (the rest still failed on open_chimneys_count).

Re-derived the exact set empirically from all 33 skipped cohort certs:
widen only fields that are (a) required in 21.0.0, (b) already optional in
21.0.1, AND (c) genuinely omitted by ≥1 of those certs. Result:

- KEEP optional: the 4 SapWindow refinements, the top-level vent/lighting/
  door/pressure-test block (incl. the 3 previously-missed fields), 2
  SapEnergySource fields, Addendum.addendum_numbers, PhotovoltaicSupply.
  none_or_no_details, and exactly ONE building-part field
  (SapBuildingPart.roof_insulation_thickness — omitted by 7 certs).
- REVERT to required: the other 12 SapBuildingPart fields (construction_age_
  band, wall_construction, …), MainHeatingDetail.emitter_temperature,
  PvBatteries.pv_battery, ShowerOutlets.shower_outlet — none of the 33 certs
  omit these, so they stay strict.

Mapper: coalesce the count fields (wet_rooms_count, open_chimneys_count,
cfl_/led_fixed_lighting_bulbs_count) to 0 like every other mapper, so the now-
optional values can't reach a NOT-NULL column (also drops 4 pyright ignores).

Now maps 32/33 (up from 3); the last cert hits a pre-existing pv_batteries-
shape AttributeError and degrades via the ADR-0031 skip path. pyright net
unchanged (43, no new errors); regression test rewritten to the real omitted set.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:35:36 +00:00
Khalim Conn-Kowlessar
7a970ea393 fix(repositories): fold landlord overrides when re-hydrating a Property via the UoW
PostgresUnitOfWork built its PropertyPostgresRepository without an overrides
reader, so a Property re-hydrated through the unit silently dropped its
Landlord Overrides (ADR-0032). The Baseline orchestrator runs through the UoW,
so it scored the bare lodged EPC while the Plan modelled the override-folded
Effective EPC — the two diverged (e.g. baseline effective 71/C vs plan
baseline 62/D), producing "already at band C yet recommends reaching C".

Wire PropertyOverridesPostgresReader into the unit's property repo (uow-
independent committed reference data, read via the same session factory) so
every re-hydration folds overrides, matching the live modelling path.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:34:30 +00:00
KhalimCK
bf52eb1fcc
Merge pull request #1187 from Hestia-Homes/investigate/glazing-draughtproofing
modelling: glazing overlay models draught-proofing + frame-factor re-lodge
2026-06-24 09:32:29 +01:00
Khalim Conn-Kowlessar
80d617aa5b modelling: glazing overlay models draught-proofing + frame-factor re-lodge
Fitting sealed glazing units changes two things beyond the pane's U/g
that the cascade reads, which the overlay didn't model — leaving the
double/secondary before→after pins ~0.7 SAP short (xfail):

1. Draught-proofing (RdSAP 10 §8.1). Sealed units draught-proof the panes
   they replace, re-lodging the dwelling-level `percent_draughtproofed`
   (cert 001431: 84 → 100). The §2 cascade reads that dwelling-level
   value, so the overlay now carries it. `_recompute_percent_draughtproofed`
   anchors on the lodged before-% — `after = round((round(before%/100 × N)
   + flips) / N × 100)`, N = openable windows (vertical + roof) + doors,
   flips = upgraded panes that were not draught-proofed — so it's robust
   to incomplete window extraction (unchanged openings are already in the
   aggregate). ~0.3 SAP.

2. Frame factor (§6 solar gains). A replacement unit re-lodges its own
   FF=0.70, overriding the pane it replaced — the two "single glazing,
   known data" panes lodge FF 1.00 / 0.50 (one is 6.6 m²), so leaving them
   unchanged understated solar gains by ~+150 kWh space heating. `WindowOverlay`
   now carries `frame_factor`, written flat onto the window. ~0.4 SAP.

Wiring: `EpcSimulation.percent_draughtproofed` + `WindowOverlay.frame_factor`
new fields; `apply_simulations` / `_fold_window` write them; the glazing
generator computes both from the upgraded set and cert 001431's after.

Un-xfails `test_{double,secondary}_glazing_overlay_reproduces_the_relodged_after`
— both now pin SAP/CO2/PE to the relodged after within tolerance. Updates
the two `test_glazing_recommendation` overlay expectations for the new
`frame_factor`. 96 modelling tests pass; zero new pyright errors.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-24 08:25:08 +00:00
Jun-te Kim
22cb47a280
Merge pull request #1285 from Hestia-Homes/feature/e2e-runs
fix(modelling_e2e): persist predicted EPC + baseline for predicted pr…
2026-06-24 09:08:06 +01:00
Jun-te Kim
4a1160a4b3
Merge pull request #1284 from Hestia-Homes/fix/wet-rooms-count-not-null
Default RdSAP 21.0.1 wet_rooms_count to 0 (fix NOT-NULL violation, 37 e2e failures)
2026-06-24 09:07:49 +01:00
Jun-te Kim
c49682658a ci: disable integration/deploy/protect workflows (Actions minutes)
Comment out the remaining workflows to cut GitHub Actions usage, per request:
- integration_tests.yml — rebaselining integration suite (PRs to main)
- deploy_fastapi_backend.yml — FastAPI backend deploy (push to dev/prod);
  deploys must be run manually via `sls deploy` while disabled
- protect_releases.yml — main→dev PR-source guardrail

Fully commented (not deleted) so each restores by uncommenting.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 07:56:42 +00:00
Jun-te Kim
f2ace566c3 ci: disable unit_tests.yml workflow (Actions minutes)
Comment out the Docker-based unit-test workflow — it was consuming too many
GitHub Actions minutes. Fully commented (rather than deleted) so it can be
restored by uncommenting.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 07:54:07 +00:00