# Wall Insulation Eligibility (cavity vs IWI vs EWI)
The solid-wall Recommendation Generator must decide, per Property, which wall-insulation Option(s) to offer. We decided eligibility is fixed first by **wall construction**, then narrowed by **planning status**, and that **External (EWI)** and **Internal (IWI)** wall insulation are two competing **Measure Options** under one "Main wall" **Recommendation** (the Optimiser picks at most one), consistent with ADR-0016 and the "cavity-fill vs EWI" exclusivity already described in CONTEXT.md.
## Decision
**By construction** (keyed on the `wall_construction` code, which is consistent across the API and Elmhurst paths for codes 1-5; the wall *description* is empty on the Elmhurst ingestion path so it can't be the primary signal — it's a fallback for the ambiguous codes (cob 7) and for refining the as-built trigger on the API path).
**System-built** is keyed on `wall_construction == 6` (`WALL_SYSTEM_BUILT`; the Elmhurst `SY System build` label). This code is currently *overloaded*: `B Basement wall` also maps to 6 (`BASEMENT_WALL_CONSTRUCTION_CODE`, `mapper.py:2100`), so the generator additionally guards on `main_wall_is_basement` — a basement wall is never solid-wall-insulation-suitable and is excluded regardless of construction. Because `main_wall_is_basement` is presently derived as `wall_construction == 6`, *every* code-6 wall is treated as basement today, so the system-built branch is inert until the calculator disambiguates system-built from basement (target: MAIN `wall_construction == 6` with `main_wall_is_basement` False — tracked in Hestia-Homes/Model#1177). The strict-xfail pin `test_system_built_generator_offers_ewi_and_iwi_each_pinning_its_after` is the tripwire for that fix. Note `wall_construction == 8` is **Park home** (`PH`) on the Elmhurst path, *not* system-built — do not key system-built on 8.
| Construction | Cavity fill | IWI | EWI |
|---|---|---|---|
| Cavity | ✅ only | ❌ | ❌ |
| Solid brick | — | ✅ | ✅ |
| System built | — | ✅ | ✅ |
| Timber frame | — | ✅ | ❌ (not constructable) |
| Cob / Granite-whinstone / Sandstone-limestone | — | ❌ | ❌ |
**Planning gates (on top), using three *distinct* flags (see ADR-0020):**
- **Conservation area** or **Flat** → remove **EWI** (external-appearance / whole-block constraints); IWI still offered.
- **Listed** or **Heritage** → remove **both** EWI and IWI (protected fabric).
A Recommendation is produced only when the wall is genuinely uninsulated (description contains "no insulation"), at a fixed **100 mm** insulation depth.
## Considered options
- **Mirror the legacy `is_suitable_for_solid_insulation` / `ewi_valid` rules verbatim.** Rejected in part: legacy collapsed all three planning flags into one `restricted_measures` boolean that blocked EWI only. We keep the flags distinct so listed/heritage can block IWI too — a deliberate strengthening.
- **Offer solid-wall insulation on cob/stone** (the calculator *can* model it — Elmhurst produces valid after-certs). Rejected: recommending standard EWI/IWI on breathable cob/rubble-stone fabric risks trapping moisture; we do not auto-suggest it.
## Consequences
- Cob and both stone types get **no** wall-insulation recommendation at all, even though the SAP calculator scores them fine — this is a deliberate building-pathology safeguard, not a gap.
- The conservation/listed/heritage gate depends on Property data not yet ingested (ADR-0020); until that lands the gate is an explicit generator input defaulting to "unrestricted", so the offline generator over-offers EWI in the interim. Not production-exposed.