Pins that the unchanged cap regime (min of 0.7×Google and the ADR-0038
budget) flows into ADR-0058 derivation — no red phase; the tracer
implementation passed the already-min'd cap through.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Pins the ADR-0058 install floor delivered with the tracer slice (rung_max
< 2 returns empty) — no red phase.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Pins behavior delivered with the tracer slice (derivation starts from the
north-dropped remainder) — no red phase; the mutation is discriminating
(a kept north panel would win fill-by-generation and shift the yields).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
30 pairs (28 deterministically scoreable) from the 2,000-postcode sweep,
frozen as ONE anonymised raw-payload JSON (pairs + cohorts + actuals — a
thousand per-cert files would drown the PR diff). The gate replays the
whole conditioning path offline — mapper, conditioning, selection,
synthesis, comparison — in ~9s; floors are the measured values, tighten-
only. comparable_from_payload is extracted from the corpus loader so both
fixture formats share one payload->ComparableProperty path; the builder
(build_expired_pairs_corpus.py) refreezes from the raw-JSON disk cache.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
The last real archetype on the companion-gap log; the log test now
simulates a future incomplete archetype (warm-air heat pump, Group 5
control deliberately unmapped).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Supersedes the "direct-acting electric drags no control/category" pin:
None does not mean unset — it means inherit the replaced system's value
(ADR-0048 bug class), verified suppressing HHRSH on portfolio 796.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
_u_brick_thin_wall_age_a_to_e's `<= 280` check put an uninsulated solid-
brick wall of exactly 280mm in the "200 to 280mm -> 1.7" row; RdSAP 10
§5.7 Table 13 (spec PDF p.41) shares 280 as an unlabelled edge between
that row and "280 to 420mm -> 1.4", so the table text alone doesn't say
which row owns it.
Found by building cert 100031768368 (280mm exactly, band C) in Elmhurst
and comparing every worksheet line to the calculator: volume/ACH/floor/
doors matched exactly, but the wall didn't (1.70 vs Elmhurst's 1.40)
despite an identical input crosswalk. Initially reverted a first attempt
at this fix when it appeared to regress an already-pinned cert
(217091901, band A, also nominally 280mm, previously "confirmed" at
U=1.70) — but that cert's build script never actually set a wall
thickness field, so its shared Elmhurst assessment had silently
inherited a stale 260mm from an earlier build. Fixed that build script
and rebuilt with the correct 280mm entry: Elmhurst's worksheet now also
gives U=1.40, matching 100031768368 and confirming the fix rather than
contradicting it.
Both certs move to (near-)exact lodged matches: 100031768368 59.12 ->
61.21 (lodged 61, within 0.5); 217091901 60.82 -> 61.59 (lodged 62,
exact). Corpus gauge 77.8% -> 78.6% within-0.5, MAE 0.636 -> 0.627 (14
corpus certs lodge exactly 280mm solid brick). TDD'd, 46 pins + full
suite green (2310 passed).
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
`from_sap_schema_17_1` hardcoded is_dwelling_export_capable=False, so
SAP 10.2 Appendix M1 zeroed the PV export credit on every export-capable
full-SAP cert. Cert 0380-3044-6070-2305-5925 (property 741840, PRD #1435
WS3) now reproduces its lodged 92 exactly (was 89); the existing
19.1.0 pin 10096028301 closes its documented -1 residual (84 -> 85 =
lodged). The full-SAP top-level pv_connection is deliberately NOT
carried: its enum disagrees with the RdSAP one the calculator gates on.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>