Commit graph

374 commits

Author SHA1 Message Date
Khalim Conn-Kowlessar
4641717c90 Blend an off-peak meter's day/night rate by high-rate fraction 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 16:55:10 +00:00
Jun-te Kim
e2915d8042 Prefer a MAIN-bearing prediction template so EPC-less dwellings predict 🟩
A predicted EPC is seeded by deep-copying one representative neighbour's
structure. _template chose the member whose floor area was closest to the
cohort median, ignoring building-part labels. When that member's only part
was lodged with a null identifier (mapped to OTHER), the prediction had no
MAIN part and the modelling_e2e handler rejected it as "not predictable" —
discarding an otherwise-rich same-type cohort.

Restrict the template to MAIN-bearing members (median still over the whole
cohort); fall back to closest-on-size only when none are MAIN-bearing, so an
all-unlabelled cohort is left for the handler's MAIN-part guard to reject
rather than silently relabelling real data.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 13:20:43 +00:00
Jun-te Kim
abb822c1c7 Prefer a MAIN-bearing prediction template so EPC-less dwellings predict 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 13:16:54 +00:00
Jun-te Kim
fc7cfc70e8
Merge pull request #1295 from Hestia-Homes/fix/fuel-code-39-electricity
Map fuel code 39 (electricity, any tariff) to standard electricity
2026-06-24 12:37:25 +01:00
Jun-te Kim
782c686969 Map fuel code 39 (electricity, any tariff) to standard electricity
modelling_e2e properties with main fuel 39 failed at the price boundary
(UnpricedFuelCode since #44fff767; previously mis-rated as non-electric →
the ~14-SAP over-rating flagged in earlier review).

Code 39 is SAP Table 12 "electricity, any tariff" (epc_codes.csv main_fuel 39 =
"electricity, unspecified tariff"; spec footnote (j): defines an electric system,
cost/CO2/PE = standard electricity). It was absent from API_FUEL_TO_TABLE_32, so
to_table_32_code(39) was None → is_electric_fuel_code(39) False and pricing
raised.

Fix: map API_FUEL_TO_TABLE_32[39] = 30 (standard electricity) — the canonical
place Khalim's fuel work added codes. One line makes classification, pricing,
CO2/PE and the billing carrier all agree (39 → 30 → ELECTRICITY).

Tests: to_table_32_code(39)==30, is_electric_fuel_code(39) True, price == standard
electricity, and the billing carrier resolves to ELECTRICITY. 0 corpus impact
(no lodged corpus cert uses 39); accuracy + mapper-corpus gates green.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 11:20:32 +00:00
Khalim Conn-Kowlessar
f6ec96fbcd Merge remote-tracking branch 'origin/main' into feature/e2e-runs
# Conflicts:
#	domain/sap10_calculator/tables/table_12a.py
2026-06-24 11:07:42 +00:00
KhalimCK
f7f74ea72b
Merge pull request #1288 from Hestia-Homes/feature/per-cert-mapper-validation
Feature/per cert mapper validation
2026-06-24 12:04:00 +01:00
Jun-te Kim
46fc8f338c
Merge pull request #1289 from Hestia-Homes/fix/solar-missing-max-array-panels
Treat solar block without array sizing as no-solar (fix KeyError maxArrayPanelsCount, 2 e2e failures)
2026-06-24 11:59:57 +01:00
Jun-te Kim
41ebf01969
Merge pull request #1287 from Hestia-Homes/fix/dual-fuel-billing-carrier
Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode fuel_code 10, 10 e2e failures)
2026-06-24 11:49:18 +01:00
Khalim Conn-Kowlessar
db3bf00602 fix(synthesis): Coherent Heating System — synthesisers own the whole boundary
A dwelling's heating is one conceptual system, but its fields are scattered
across EpcPropertyData (a gov-API schema mirror): the cluster on sap_heating, the
electricity tariff on sap_energy_source.meter_type, hot-water flags loose at top
level. Three places synthesise a heating system — Measure Options, Landlord
Overrides, EPC Prediction's donor — and each hand-copied a different ad-hoc
subset. The override and donor both dropped meter_type, so an electric-storage
system landed on the template's single-rate meter and billed overnight heat at
the peak rate: property 713406 scored SAP 13 (G) vs ~50 (E), inflating the HHRSH
measure to +45.8 and overshooting the plan to band A.

Establish a single Coherent Heating System boundary (CONTEXT.md) that every
synthesiser must cover, with a source-appropriate fill policy (ADR-0035):

- Override overlay *completes* the partial system the landlord named. Companion
  fields are now DERIVED from the SAP code, not hand-attached per archetype: the
  off-peak meter from the calculator's single off-peak classification (new
  OFF_PEAK_IMPLYING_HEATING_CODES = SAP §12 Rules 1-2), and an unobserved storage
  charge control defaults to the conservative manual control (Table 4e 2401). So
  adding a heating archetype is just adding its code — companions can't be
  forgotten. A contract test guards it (every off-peak code drags a Dual meter).
- Prediction's heating donor now *carries* the donor's meter_type alongside its
  sap_heating cluster — the donor is already coherent.

Coherence is a synthesis-time obligation only; the calculator still scores a real
lodged cert exactly as lodged.

Verified on 713406: baseline 13 -> 47.8 (E), matching its recorded rating; the
phantom HHRSH recommendation is gone and the plan no longer overshoots to A.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:46:11 +00:00
Jun-te Kim
79f89d872e Treat solar block without array sizing as no-solar (fix KeyError)
2 modelling_e2e properties failed with KeyError: 'maxArrayPanelsCount'.

Google returns a `solarPotential` block with no array-level sizing fields
(`maxArrayPanelsCount` / `panelCapacityWatts`) for buildings with no usable
solar estimate. `SolarPotential.from_building_insights` hard-indexed those keys
and crashed the whole property.

Fix: the projection now returns Optional and yields None when those fields are
absent — the established "no solar potential" outcome (the orchestrator and
recommendation path already type it Optional and skip solar on None). Existing
callers (`_solar_potential_for`, harness) already assign to Optional.

Regression test + `assert is not None` narrowing on the valid-fixture tests.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:22:06 +00:00
Jun-te Kim
d97b8e87a4 Add dual-fuel (mineral+wood) billing carrier (fix UnmappedSapCode 10)
10 modelling_e2e properties failed with "unmapped SAP code in fuel_code: 10":
the billing layer (`sap_code_to_fuel`) had no carrier for Table-32 code 10
(dual fuel, mineral + wood) and raised rather than guess one.

SAP 10.2 treats dual fuel as its OWN fuel (its own Table-12 factors), so model
it as its own billing carrier rather than collapsing onto wood or coal:

- New `Fuel.DUAL_FUEL_MINERAL_AND_WOOD`.
- `_CODE_TO_FUEL[10]` -> that carrier.
- Fuel Rates snapshot prices it at 7.69 p/kWh — the midpoint of the COAL proxy
  (7.13) and WOOD_LOGS (8.25). This mirrors SAP's own construction: Table-32
  dual fuel (3.99) ~= midpoint of house coal (3.67) and wood logs (4.23).
  Marked `derived` with a documented _note/_gap/_assumption (like the COAL and
  HEAT_NETWORK proxies), since there is no retail blend price.

A dedicated carrier + rate (vs a one-line map to an existing carrier) keeps the
fuel identity faithful to SAP and avoids mispricing dual fuel as pure wood/coal.

Tests: code 10 -> DUAL_FUEL carrier; snapshot prices it at 7.69; grid-export
codes (36/60) still raise (the genuine no-carrier case).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 10:07:57 +00:00
Khalim Conn-Kowlessar
4e2f2bdcc7 test(worksheet): pin simulated case 50 — MVHR + dual-immersion all-electric
Adds the mapper-driven e2e cascade pin for "simulated case 50" (000565 semi,
electric storage main SAP 402 + portable electric secondary + MVHR + whc-903
DUAL electric immersion + 160 L cylinder, Economy-7). Routes the Summary PDF
through extractor + mapper + calculator like the other 000565 fixtures.

Locks in two off-peak fixes this case ground-truthed:
- the Table 13 HW high/low split applied to CO2/PE (commit 39ae2cf0), and
- the Table 12a Grid 2 MVHR fan fraction 0.71/0.58 (commit cd5113ab).

All 11 SAP-result fields reconcile to the U985 worksheet EXACTLY, including
the (272) rating CO2 2397.1237 — SAP 38.8426 (=39), cost £1317.0116, water
1668.0788 kWh, fans 315.6384 kWh.

Summary mirrored to the tracked fixtures dir so the test doesn't depend on
the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:07:16 +00:00
Khalim Conn-Kowlessar
39ae2cf0c2 fix(water-heating): split whc-903 immersion HW CO2/PE on off-peak tariffs
SAP 10.2 Table 12d/12e: electric water heating on a 7-/10-hour tariff bills
CO2/PE at the high-rate code (32/34) and low-rate code (31/33), kWh-weighted
by the Table 13 high-rate fraction. The cost path already applied this split;
the CO2/PE factors did not — they used the flat annual Table 12 figure
(0.136 CO2 / 1.501 PE) for ALL dual-rate electric HW.

That flat-annual behaviour (slice S0380.163) was validated only against
HW-from-main "low-rate cost" certs (100% low, no high-rate split). It is NOT
how Elmhurst bills a whc-903 ELECTRIC IMMERSION: the hand-built case-50
worksheet (000565 + dual immersion, 7-hour) splits HW CO2/PE into "high rate
cost" (CO2 0.1475 / PE 1.5514) + "low rate cost" (CO2 0.1238 / PE 1.4429)
weighted by the Table 13 fraction 0.1009. So flat-0.136 for immersion HW was
a spec gap on our side, not an Elmhurst divergence.

Fix: `_electric_immersion_hw_high_rate_fraction` threads the Table 13 fraction
(scoped to whc-903, 7-/10-hour, cylinder data present) into the HW CO2 + PE
factor helpers, which then blend the Table 12d/12e high/low codes. The flat
rule is unchanged for HW-from-main and 18-/24-hour (no Table 12d split), so
the S0380.163 41-variant cases and the existing pin are untouched.

Case 50: rating CO2 2413.48 -> 2397.1237 = Elmhurst EXACT; demand CO2 2007.1384
EXACT; demand PE +111 -> +32.5 residual (within corpus PE noise). Corpus
unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4 (62 whc-903 off-peak certs;
aggregate gauges hold). SAP unaffected (cost-based).

Pin: test_whc903_immersion_hw_co2_pe_factors_split_high_low_on_off_peak; doc
updated in SAP_CALCULATOR.md §8.1.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 09:05:21 +00:00
Khalim Conn-Kowlessar
f3e3494bf7 test(worksheet): pin simulated case 52 — regular gas boiler + cylinder
Adds the mapper-driven e2e cascade pin for "simulated case 52" (000565
semi + regular non-combi mains-gas boiler SAP 102 + 160 L foam cylinder
heated from the main, no cylinder stat, uninsulated primary pipework,
standard tariff). Routes the Summary PDF through extractor + mapper +
calculator like the other 000565 / 001431_case* fixtures.

This closes the last untested branch of the cylinder/water chain: the
SAP 10.2 §4 cylinder storage loss (Table 2/2a/2b lines 51-55) + the
Table 3 PRIMARY circuit loss (59, uninsulated pipework + no stat) that
combi/immersion fixtures don't reach. All 11 SAP-result fields reconcile
to the U985 worksheet EXACTLY with no calculator change — SAP 57.2904
(=57), cost £911.1973, water 3929.7635 kWh — confirming the cylinder-loss
derivation is correct.

Summary mirrored to the tracked fixtures dir so the test doesn't depend
on the unstaged `sap worksheets/` workspace.

pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-24 08:50:19 +00:00
Khalim Conn-Kowlessar
80d617aa5b modelling: glazing overlay models draught-proofing + frame-factor re-lodge
Fitting sealed glazing units changes two things beyond the pane's U/g
that the cascade reads, which the overlay didn't model — leaving the
double/secondary before→after pins ~0.7 SAP short (xfail):

1. Draught-proofing (RdSAP 10 §8.1). Sealed units draught-proof the panes
   they replace, re-lodging the dwelling-level `percent_draughtproofed`
   (cert 001431: 84 → 100). The §2 cascade reads that dwelling-level
   value, so the overlay now carries it. `_recompute_percent_draughtproofed`
   anchors on the lodged before-% — `after = round((round(before%/100 × N)
   + flips) / N × 100)`, N = openable windows (vertical + roof) + doors,
   flips = upgraded panes that were not draught-proofed — so it's robust
   to incomplete window extraction (unchanged openings are already in the
   aggregate). ~0.3 SAP.

2. Frame factor (§6 solar gains). A replacement unit re-lodges its own
   FF=0.70, overriding the pane it replaced — the two "single glazing,
   known data" panes lodge FF 1.00 / 0.50 (one is 6.6 m²), so leaving them
   unchanged understated solar gains by ~+150 kWh space heating. `WindowOverlay`
   now carries `frame_factor`, written flat onto the window. ~0.4 SAP.

Wiring: `EpcSimulation.percent_draughtproofed` + `WindowOverlay.frame_factor`
new fields; `apply_simulations` / `_fold_window` write them; the glazing
generator computes both from the upgraded set and cert 001431's after.

Un-xfails `test_{double,secondary}_glazing_overlay_reproduces_the_relodged_after`
— both now pin SAP/CO2/PE to the relodged after within tolerance. Updates
the two `test_glazing_recommendation` overlay expectations for the new
`frame_factor`. 96 modelling tests pass; zero new pyright errors.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-06-24 08:25:08 +00:00
Khalim Conn-Kowlessar
cd5113abf2 fix(tariff): include MVHR fan electricity in the off-peak Grid 2 fan split
SAP 10.2 Table 12a Grid 2 (PDF p.191) bills "Fans for mechanical ventilation
systems" at 0.71 (7-hour) / 0.58 (10-hour), distinct from "All other uses"
(0.90 / 0.80) which covers circulation pumps, flue fans and the solar HW pump.

The cost-split mech-vent kWh (`mev_kwh_for_cost_split`) only summed the
decentralised-MEV (230b) fans, not the (230a) MVHR fan electricity — even
though the total pumps/fans bucket adds both. So an MVHR dwelling on an
off-peak tariff billed its fan electricity at the 0.90/0.80 "all other uses"
rate instead of 0.71/0.58. The comment already said "MEV/MVHR-fan portion";
only the MEV term was wired when MVHR landed. Fixed to mirror both
mechanical-ventilation fan terms summed into the total.

Worksheet-proven on simulated case 50 (000565 semi + MVHR Vent Axia + dual
electric immersion, Unknown meter -> 7-hour via the §12 dual-immersion
trigger): the fan bucket (315.64 kWh, 100% MVHR per worksheet line 230a) was
billing at 14.311 p/kWh (0.90) vs Elmhurst's 12.451 p/kWh (0.71) — +£5.87/yr,
-0.23 SAP. After the fix our existing-dwelling rating reconciles to Elmhurst
EXACTLY: SAP value 38.8426 (=Elmhurst 38.8426 -> 39), total cost £1317.0116
(=Elmhurst £1317.0116 to the penny).

Same `mev_kwh_for_cost_split` feeds the CO2 + PE cascades, so all three split
consistently. 0 corpus impact (all 3 corpus MVHR certs are standard tariff);
gauge unchanged 73.3% / MAE 0.774 / CO2 0.08 / PE 3.4.

Pin: test_mvhr_fan_electricity_bills_at_grid2_fan_fraction_on_off_peak.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 22:16:58 +00:00
Khalim Conn-Kowlessar
eea5d3a5a8 fix(tariff): map electric boilers 191/193-196 to their Table 12a Grid 1 rows
SAP 10.2 Table 4a electric boilers (PDF p.170) split across three distinct
Table 12a Grid 1 SH rows (PDF p.191), not one "direct-acting" family as the
stale TODO in `_table_12a_system_for_main` implied:

  - 191 Direct-acting electric boiler   -> "Direct-acting electric boiler (a)"
    row: 7-hour 0.90, 10-hour 0.50 (NOT the 1.00/0.50 "Other direct-acting
    electric heating" room-heater row).
  - 193/194/195/196 Electric dry core / water storage boiler -> "Electric dry
    core or water storage boiler" row: 7-hour 0.00 (charged wholly off-peak =
    100% low rate, identical to the None fallback).
  - 192 Electric CPSU -> Appendix F; left falling through to None (off-peak
    low) until the Appendix-F high-rate cascade is implemented.

The enum + fractions already existed in table_12a.py; only the code->enum
mapping was missing. Resolves the TODO and pins the spec-correct 0.00 for the
storage boilers so 195 can't be mis-"fixed" up to a direct-acting fraction.

Forward guard, 0 corpus impact: storage boilers already billed 100% low via
the None fallback, and all corpus 191 certs are on standard tariff (Table 12a
off-peak split never fires). Corpus gauge unchanged 73.3% / MAE 0.774.

Pin: test_electric_boilers_191_195_map_to_distinct_table_12a_grid1_rows.
pyright strict gate not run locally (pyright not installed in this container).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:48:59 +00:00
Khalim Conn-Kowlessar
9694650abe fix(water-heating): derive combi keep-hot from the PCDB record, default no-keep-hot
SAP 10.2 Table 3a (PDF p.160) additional combi loss (61)m. Two coupled
defects, both surfaced by simulated case 49 (000565 + gas combi, U985
"Combi keep hot type = None") sitting at SAP 71.43 vs the worksheet's 72:

1. The cascade defaulted EVERY non-PCDB combi to the flat keep-hot
   time-clock row (600 × n/365). A combi WITHOUT a keep-hot facility uses
   row 1 (600 × fu × n/365, fu = V_d/100 when daily HW < 100 L/day) —
   over-counting (61)m for the no-keep-hot cohort. `water_heating_from_
   cert` now defaults to the "without keep-hot" row.

2. `pcdb_combi_loss_override` returned None for keep_hot_facility=1/
   timer=1, leaning on the OLD flat-600 default. So flipping the default
   silently turned 190 corpus PCDB keep-hot-time-clock combis into
   no-keep-hot. Fixed to return the flat keep-hot row EXPLICITLY.

Key insight (the Summary is the input echo; the U985 keep-hot line is a
computed OUTPUT, so it must be derivable): keep-hot rides on the PCDB
boiler record (Table 105 keep_hot_facility/timer), resolved by
`pcdb_combi_loss_override`. A generic SAP-code combi with no PCDB record
(case 49, PCDF ref 0) has no keep-hot by construction → row 1. So the
default is not a guess — it is the spec-correct value for non-PCDB combis.

Worksheet-proven: case 49 → cost £726.696, SAP 72 — matching the
accredited worksheet to the digit (continuous 71.6945 = the worksheet's
own 71.6945). 000516 (keep-hot None) also exact (£860.716, SAP 63);
000490 (PCDB 10328, keep_hot_facility=1/timer=1) keeps its flat-600 via
the PCDB path. Masked until now because every prior combi-loss worksheet
fixture was keep-hot (000490/000474/000480 time-clock) or had V_d >= 100
every month (001431, rows coincide); case 49 is the first no-keep-hot one.

Corpus within-0.5 72.7% -> 73.3%, MAE 0.781 -> 0.774, PE 3.5 -> 3.4;
ratcheted _MAX_SAP_MAE 0.785 -> 0.775, _MAX_PE_PER_M2_MAE 3.6 -> 3.5.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 21:22:02 +00:00
Khalim Conn-Kowlessar
7b30b464e5 feat(ventilation): credit MVHR (24a) heat recovery via PCDB Table 323 + 329
MVHR (24a) heat-recovery support, part 2: the mapper + cascade wiring.

Both source paths now resolve balanced whole-house MV with heat recovery
to the MVHR kind:
- gov-API: `_API_MECHANICAL_VENTILATION_TO_KIND` 4 → "MVHR" (was None /
  treated as natural — under-stated ventilation heat loss, over-rating).
- Elmhurst Summary: `_ELMHURST_MV_TYPE_TO_KIND` "Mechanical ventilation
  with heat recovery (MVHR)" → "MVHR" (was UnmappedElmhurstLabel, which
  blocked the whole Summary for MVHR dwellings).

cert_to_inputs resolves the in-use heat-recovery efficiency + SFP for an
MVHR cert (`_mvhr_system_values`): pick the PCDB Table 323 data point by
the lodged wet-room count (SAP 10.2 §2.6.4), multiply the raw efficiency
by the Table 329 ducts-inside-envelope in-use factor (0.90) and the raw
SFP by the per-duct-type factor (rigid 1.4), and feed:
- the §2.6.6 eq (2) effective-air-change credit (23c) → (24a)/(25)m;
- the (230a) fan electricity (in-use SFP × 1.22 × V), costed but NOT
  added to the Table 5a gains (its effect is in the efficiency).
An MVHR lodged with no PCDF index falls back to the SAP 10.2 Table 4g
default (raw efficiency 66% × 0.70, raw SFP 2.0 × 2.5).

Worksheet-proven on simulated case 49 (000565 semi + Vent Axia Sentinel
Kinetic B 500140 + gas combi → Elmhurst Current SAP 72): every MVHR line
matches Elmhurst exactly — (33) fabric heat loss 100.5923, (23c) in-use
efficiency 81.9% = 91 × 0.90, (25)m Jan 0.8571, (230a) fan electricity
415.9325, (231) total pumps/fans 501.9325. The residual SAP 71 vs 72 is
the known 000565-family space-heating-demand artifact (same -1/-2 seen on
cases 47/48), not the MVHR logic.

Corpus: within-0.5 72.6% -> 72.7%, MAE 0.788 -> 0.782, PE 3.6 -> 3.5.
The 3 gov-API MVHR certs: Flat 1 +6 -> 0 (Table 4g default path) and
12a Princes Gate +3 -> +1 (heat-recovery credit); Apartment 707 -4 -> -6
is a separate baseline under-rate (it under-rated as natural too — the
MVHR credit correctly adds ventilation loss per Elmhurst's method).
Ratcheted _MAX_SAP_MAE 0.79 -> 0.785, _MAX_PE_PER_M2_MAE 3.7 -> 3.6.

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:45:37 +00:00
Khalim Conn-Kowlessar
34cbd7d66c feat(pcdb): parse Table 323 (Centralised MEV / MVHR) + Table 329 efficiency IUF
MVHR (24a) heat-recovery support, part 1: the PCDB data layer.

PCDB Table 323 (PCDF Spec Rev 6b §A.18, Format 426; pcdb10.dat carries
Format 431, header `$323,431,...`) holds the per-wet-room SFP + heat-
exchanger efficiency for centralised MEV / MVHR units. Added
`MvhrRecord` / `MvhrDataPoint`, `parse_centralised_mv_row` /
`parse_table_323`, the ETL step, the committed jsonl, and the
`mvhr_record(pcdb_id)` runtime lookup (mirrors Table 322).

SAP 10.2 §2.6.4/§2.6.6: "MVHR ... SFP is a single value depending on the
number of wet rooms" — each test group's leading field is the wet-room
count; callers select the group matching the dwelling lodgement.
Worksheet-proven on simulated case 49 (000565, 2 wet rooms, Vent Axia
Sentinel Kinetic B 500140 → flow 21.0, SFP 0.88, efficiency 91%).

Also decoded the MVHR heat-recovery efficiency in-use factor from Table
329 (Format 432): system_type 3 ducts-inside-envelope = 0.90 (case-49
(23c) = 91 × 0.90 = 81.9%), cross-checked against system_type 10 = 0.70
(= SAP 10.2 Table 4g default heat-recovery in-use factor). "Table 4h is
no longer used – data now stored in the PCDB" (SAP 10.2 p.176).

The outside-envelope efficiency columns + with-scheme SFP blocks are
preserved verbatim in `raw` (no fixture exercises them yet).

Note: pyright strict type gate not run locally (pyright not installed).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 19:29:17 +00:00
Jun-te Kim
9956df07ff Land an override on the EPC's part at its position when the label is absent 🟩
A Landlord Override's building_part is a positional index (0=main, 1=extension
1…, ADR-0004), but the gov-API EPC can label that slot differently (e.g. lodge
the 2nd part as 'other', not 'extension_1'). The previous fix skipped such
orphaned overrides, silently discarding the landlord's correction. Now the
override falls back onto the EPC's part at that position (via _resolve_part), so
the correction lands; only a position the EPC models no part at is skipped
(no geometry to model a wholly-absent part). Replaces the skip-only behaviour.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 17:09:11 +00:00
Jun-te Kim
8f0432721c test(accuracy): pin RdSAP-20.0.0 PV semi uprn_22086693 (PV-list fix corpus)
Corpus validation of the modelling_e2e photovoltaic_supply-as-list fix. Cert
6102-6227-8000-0083-2292 (RdSAP-20.0.0 semi, gas combi + 2× 1.14 kW PV arrays)
crashed from_rdsap_schema_20_0_0 on the measured-array list; the fix routes it
through the dict-tolerant _map_schema_21_pv. PV correctly credited: engine 61
(no PV) → 66 (+5). Built in Elmhurst (evidence: epc.json + summary + worksheet,
fabric+heating; the PV "New Technologies" Panel-details grid deferred): worksheet
55 = engine-on-Elmhurst-inputs 55 exactly → calculator faithful. The +6 engine-vs-
Elmhurst base-dwelling residual is the documented RdSAP-default gap (band-C cavity-
uninsulated suspended-floor semi). Pinned engine 66.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 16:13:34 +00:00
Jun-te Kim
539f661430 Skip a landlord override that targets a building part the EPC lacks 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:19 +00:00
Jun-te Kim
17b1d63f0e test(accuracy): pin SAP-16.0 storage-flat uprn_10070004512 (built_form fix corpus)
Corpus validation of the modelling_e2e built_form fix. Cert 8742-6624-9300-2780-4926
(SAP-Schema-16.0, ground-floor electric-storage-heater flat) omits built_form; the
mapper now derives it from dwelling_type. built_form is ML-only so the fix is
SAP-neutral: engine 66 = lodged 66 exactly. Built in Elmhurst (evidence: epc.json +
summary + worksheet): worksheet 54, engine-on-Elmhurst-inputs 53 ≈ 54 → calculator
faithful. The +12 engine-vs-Elmhurst is a build/input gap (cert size-1 small cylinder
unrepresentable in Elmhurst's Normal/110L-minimum entry → higher HW + reduced-field
16.0 defaults). Pinned engine 66.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 15:35:06 +00:00
Jun-te Kim
666cf30437 gated propertly 2026-06-23 13:16:34 +00:00
Khalim Conn-Kowlessar
4db05e843c fix(ventilation): dMEV takes lodged 0 intermittent fans, not the Table 5 default (SAP 10.2 §2)
Chasing the space-heating demand gap on "simulated case 48" (main 691 + Unknown
meter + 903 dual immersion): our SAP 55 vs Elmhurst 57. Every §10a cost line
already matched to the penny; the residual was demand — our space-heating
energy 3849.8 kWh vs Elmhurst 3513.8 (+9.6%). Traced through the worksheet: our
ventilation heat loss (38) ran ~35.5 W/K vs Elmhurst 27.76 — we were adding 20
m3/h of intermittent extract fans (the Table 5 age-band default) on a dwelling
with a decentralised mechanical extract (dMEV) system that lodges 0 fans.

SAP 10.2 §2 (PDF p.13): a whole-house mechanical EXTRACT system provides
extraction via the (23a) 0.5 system air-change rate; the lodged intermittent
extract-fan count (7a) is then explicit — a lodged 0 means 0 (the dMEV is the
ventilation), NOT "unknown". The Table 5 default is an unknown-fallback for
NATURALLY ventilated dwellings only, so it must not be substituted here.

Fix: for EXTRACT_OR_PIV_OUTSIDE, take vc.intermittent_fans as-is (no age-band
default). Worksheet-proven on two dMEV builds of cert 000565: "case 48" lodges
(7a)=0 -> our SAP 55 -> 57 EXACT; the original 000565 fixture lodges (7a)=2 and
keeps 2 (its e2e pins are unchanged). An earlier draft that forced fans=0 broke
000565 (which legitimately has 2) — corrected to "lodged as-is".

within-0.5 72.5% -> 72.6%, MAE 0.789 -> 0.788; CO2/PE unchanged. The fix also
reduces a systematic under-rating bias in the 21-cert dMEV cohort (median dSAP
-0.22 -> -0.08). Scoped to EXTRACT_OR_PIV_OUTSIDE; balanced MVHR/MV kinds left
untouched pending their own worksheet. SAP-schema regression
test_18_0_0 pin 80 -> 81 (closer to its lodged 84, same cause). Spec-pinned in
test_cert_to_inputs (dMEV-lodged-0 vs natural-default). pyright not installed
in this container -- strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 11:33:07 +00:00
Jun-te Kim
210ca6397f updated sap scaema to take in inputs 2026-06-23 10:22:40 +00:00
Khalim Conn-Kowlessar
fd0530159f feat(tariff): complete §12 Unknown-meter clause — GSHP/WSHP main triggers off-peak (RdSAP 10 PDF p.62)
Closes the follow-up from 22fe4f41. RdSAP 10 §12's third Unknown-meter
exception bullet — "main heating is ground source or water source heat pump" —
was unimplemented. Add `_GROUND_OR_WATER_SOURCE_HEAT_PUMP_CODES` (Table 4a,
SAP 10.2 PDF p.176-177: ground 211/215/221/225 + warm-air 521/525; water
213/216/223/226 + warm-air 523/526) to the Unknown-meter off-peak triggers;
once dual, Rules 1-4 (Rule 3) resolve it to 10-hour.

AIR-source heat pumps (214/217/224/227, 524/527) are deliberately EXCLUDED —
the spec names only ground/water source. Verified the only Unknown-meter heat
pumps in the corpus are "3/10 Bedford House" (main 214 = AIR source), which
correctly KEEP STANDARD. 0 corpus certs carry a GSHP/WSHP on an Unknown meter,
so this is a spec-completeness forward guard (gauge unchanged 72.5% / 0.789),
same family as the Scotland-J wall / rafters-M roof 0-impact spec fixes.
Coverage gap noted in-code: a database-index heat pump without a 211/213-style
SAP code can't have its source type read from the code alone (rare).

Spec-pinned (test_unknown_meter_ground_or_water_source_heat_pump_triggers_off_
peak). Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
suite 2989 passed (2 known pre-existing fails). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 10:09:59 +00:00
Khalim Conn-Kowlessar
22fe4f41b8 fix(tariff): Unknown meter + dual electric immersion → off-peak per §12 (RdSAP 10 PDF p.62)
Supersedes the previous "verified non-fix" doc (3548f1f3): the spec DOES make
this a fix — Khalim was right that the Unknown-meter branch is driven by the
heating/water system, not a blanket STANDARD.

RdSAP 10 §12 (PDF p.62): "If the electricity meter is unknown, treat as single
meter EXCEPT where main heating OR WATER HEATING are intended to run off an
off-peak tariff (per systems listed in the text box above) ... If that results
in a dual meter, assign tariff per rules 1 to 4." The text-box off-peak systems
include DUAL ELECTRIC IMMERSION. Our `rdsap_tariff_for_cert` only triggered the
Unknown→off-peak exception on a storage/CPSU MAIN — it ignored the
dual-electric-immersion WATER-heating trigger, so an Unknown-meter dwelling
with a non-storage main (e.g. room heaters) + dual immersion was billed
STANDARD (13.19p flat) when it should be dual → Rules 1-4 on the main.

Fix: thread `water_is_off_peak_dual_immersion` (whc 903 + immersion lodged dual
via `_immersion_is_single is False`) into the Unknown-meter branch; when any
text-box trigger is present, resolve via the same Rules 1-4 dispatch (room
heaters → Rule 3 → 10-hour). Single-immersion / instantaneous (whc 909) certs
correctly stay STANDARD (no text-box system).

Worksheet-validated on "simulated case 48" (main 691 + Unknown meter + 903 dual
immersion): Elmhurst 10-Hour Off Peak, SAP 57; ours 45 → 55 (7-hour gives 45,
confirming 10-hour). Flips exactly ONE corpus cert — Apartment 241 (the genuine
-5.38 under-rater, main 691 + dual immersion) -5.38 → -1.05; every other
Unknown+dual-immersion cert already has a storage main (Rule 2). Corpus
within-0.5 holds 72.5%, MAE 0.793 → 0.789 (improved). CO2/PE unchanged.

GSHP/WSHP-main trigger (the other §12 Unknown exception bullet) is a separate
follow-up. Gates green: corpus 72.5%/0.789, batch worksheet 0 raised/0 diverge,
000565 e2e 11/11, suite 2987 passed (2 known pre-existing fails). pyright not
installed in this container — strict type gate not run locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 09:58:02 +00:00
Khalim Conn-Kowlessar
6a4539f26b fix(fuel): close case 47 — correct the second main heating system's fuel (off-peak pricing + Elmhurst Summary solid-fuel)
Two second-main fuel errors mis-cost a dual-main dwelling whose two main systems
burn different fuels (SAP 10.2 §10a worksheet (213) bills main 2 at its own fuel):

1. Off-peak/legacy scalar cost path (calculator.py + cert_to_inputs.py): main 2's
   kWh was priced at main 1's `space_heating_fuel_cost_gbp_per_kwh` scalar. Split
   main 1 vs main 2 and price main 2 at its OWN rate via the new
   `_main_2_space_heating_fuel_cost_gbp_per_kwh` (+ CalculatorInputs field).
   Scoped to a NON-electric second main (wood/oil/coal) — an electric second
   main keeps main 1's scalar (its off-peak Table 12a split is the deferred §10a
   slice; per-system splitting it regresses the off-peak electric cohort, certs
   13 Parkers Hill / 34 Dunley Road). 0 corpus impact (no corpus cert has a
   non-electric second main on an off-peak meter).

2. Elmhurst Summary mapper (mapper.py): when §14.1 omits the Fuel Type cell, a
   fuel-fired second main (room-heater SAP code) inherited main 1's fuel. Derive
   it from the SAP code's Table 4a category (solid 631-636 -> house coal, gas ->
   mains gas, liquid -> oil) before the main-1 inherit, mirroring
   `_elmhurst_secondary_fuel_from_sap_code` (same modal sub-fuel caveat). Boiler
   codes (<601) still inherit main 1 (case 6 oil rads+UFH).

simulated case 47 (electric room heaters + solid room heaters 633): our SAP
37.81 -> 55.09 vs Elmhurst current 57 (residual is the wood-vs-coal sub-fuel the
Summary export does not carry). Corpus unchanged 72.5% / MAE 0.793; batch 0
raised / 0 diverge; 000565 e2e green. (mapper.py also carries an earlier,
behaviour-free roof-window doc comment.) Spec-cited unit pins added (AAA).
pyright not installed locally — strict type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:46:00 +00:00
Khalim Conn-Kowlessar
44fff76722 fix(fuel): raise UnpricedFuelCode for unrecognised fuels instead of silently defaulting to mains gas
`table_32.unit_price_p_per_kwh` silently returned the mains-gas default
(3.48 p/kWh) for any fuel code it could not resolve to a Table 32 price or a
translatable gov-API enum. An unhandled fuel billed at the gas rate mis-costs
the dwelling (same failure mode as the dual-main wood-vs-electric over-cost).
Raise `UnpricedFuelCode` (new, mirrors MissingMainFuelType / UnmappedSapCode)
so the gap surfaces at the price boundary. `None` (no fuel lodged) still
defaults — callers resolve "no system" upstream.

0 corpus impact: all 1000 certs compute (every lodged fuel resolves), so this
is a forward guard against future/unmapped fuels. Unit pin added; existing
None-default test docstring tightened. pyright not installed locally — strict
type gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Khalim Conn-Kowlessar
702150002f fix(fuel): cost main heating system 2 at its own fuel price, not main 1's (SAP 10.2 §10a worksheet line 213)
Main heating system 2's space-heating fuel cost (worksheet (213)) was billed
at main system 1's Table 32 unit price (`main_2_high_rate_gbp_per_kwh` reused
`main_1_high_rate_gbp_per_kwh`). For a dual-FUEL pair this grossly mis-costs the
second main: cert 10032957680 "Copse Cottage" (main 1 electric room heaters
fuel 30, main 2 wood logs fuel 6) charged its 9481 kWh of wood at 13.19 p/kWh
instead of 4.23 p/kWh — +£850/yr → SAP 21.75 vs lodged 45.

Route main 2 through its own fuel code (`_main_fuel_code(details[1])`), mirroring
the existing secondary-fuel handling. Copse Cottage 21.75 -> 45.94. Corpus
within-0.5 holds 72.5%, SAP MAE 0.815 -> 0.793 (ratcheted ceiling 0.82 -> 0.80);
CO2/PE unchanged. Same-fuel dual mains (gas+gas) unaffected. Off-peak-tariff
dual-fuel mains still defer to the legacy scalar path (separate slice).

Spec-cited unit pin added (AAA). pyright not installed locally — strict type
gate not run.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-23 08:31:04 +00:00
Jun-te Kim
9c89a0e680 neighbouring properties added 2026-06-22 14:38:00 +00:00
Jun-te Kim
2afa7acea4
Merge pull request #1251 from Hestia-Homes/feature/hyde_make_it_more_accurate_with_tests
Feature/hyde make it more accurate with tests
2026-06-22 10:04:28 +01:00
Jun-te Kim
1b53c57a07 re run ddd tests 2026-06-22 08:52:45 +00:00
Khalim Conn-Kowlessar
a9632937d5 fix(ventilation): use lodged extract-fan count when known, not max(lodged, age default) (RdSAP 10 §4.1 Table 5, PDF p.28)
Table 5 reads "Number of extract fans if known; if number is unknown:
[age-band default]" — the default is an UNKNOWN-fallback, NOT a floor. The
cascade applied `max(lodged, table_5_default)`, flooring a genuinely-lodged
count up to the age-band minimum: e.g. an age H-M dwelling lodging 2 extract
fans was billed at the 6-8-room default of 3, over-counting ventilation line
(8) and the heat-loss coefficient. Fixed to `lodged if lodged > 0 else
default` (a lodged 0 is the Elmhurst/RdSAP "unknown" form → default; any
positive count is taken literally).

Surfaced by Khalim's Elmhurst stress worksheet (simulated case 46): this was
its last ventilation residual — our Jan effective ACH 9.14 -> 9.0748 (exact
match to the accredited worksheet), SAP 29 -> 30 = Elmhurst, cost £1496 vs
£1493. Corpus IMPROVED: within-0.5 71.6% -> 72.5%, MAE 0.819 -> 0.815 (the
max-flooring over-counted ventilation on every cert lodging fans below its
age default). Floor ratcheted 0.71 -> 0.72. pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:22:26 +00:00
Khalim Conn-Kowlessar
34e52a893c fix(heating): assume portable-electric secondary for unheated habitable rooms (SAP 10.2 Appendix A.2.2)
When the main heating system does not heat every habitable room (heated rooms
< habitable rooms), SAP 10.2 Appendix A.2.2 assumes the unheated rooms are
served by a portable-electric secondary heater, so the Table 11 secondary
fraction (0.10 for a boiler main) must be costed at the electricity tariff —
even when the cert lodges no explicit secondary system.

`_secondary_fraction` previously returned 0 unless a secondary was lodged or
the main was a forced-secondary electric-storage code, dropping the assumed
secondary and billing 100% of space heat to the (cheaper) main fuel — an
over-rate. Added an `unheated_habitable_rooms` trigger plus
`_has_unheated_habitable_rooms(epc)`, which prefers the lodged
`any_unheated_rooms` flag and guards the gov-API `heated_rooms_count == 0`
"not provided" sentinel. The secondary fuel/efficiency cascade already
defaults to portable electric (code 693) when no secondary code is lodged.

Worksheet-validated on simulated case 46 (heated 4 < habitable 7, no lodged
secondary): the assumed 10% electric secondary (2289 kWh, ~£260) lifted our
SAP 39 -> 29.35 vs accredited Elmhurst 30 (cost £1502 vs £1493, within 0.6%).

Corpus UNCHANGED (71.6% / MAE 0.819): all 17 corpus certs with heated <
habitable already lodge an explicit secondary description, so the gov-API
path was already costing it; this only adds the assumed secondary where none
is lodged (Elmhurst / reduced-field path). pyright not installed locally.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-21 06:15:37 +00:00
Jun-te Kim
a3e2566378 landlord override data added 2026-06-20 12:57:54 +00:00
Jun-te Kim
abd4bbc2d0 Merge branch 'feautre/hyde_upload_and_extend_landlord_overrides' into feature/hyde_make_it_more_accurate_with_tests 2026-06-20 07:26:35 +00:00
Jun-te Kim
3044c70202 sap score and elmhirst mapper optimsaiation 2026-06-20 07:25:42 +00:00
Jun-te Kim
3a0a122b7f Group landlord property-override enums under domain/epc/property_overrides 🟪
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:49:58 +00:00
Jun-te Kim
4fbd8d5999 Decode old/slimline/convector storage-heater heating overrides 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:20:41 +00:00
Jun-te Kim
49f783de45 Decode from-main oil/LPG/coal and gas boiler-circulator water heating 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:20:02 +00:00
Jun-te Kim
b7d2cff220 Decode bottled/special LPG, community electric/biomass, dual-fuel, smokeless coal 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:18:33 +00:00
Jun-te Kim
9d0d12c278 Lock heating-override value coverage and reader/overlay registry parity 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:10:02 +00:00
Jun-te Kim
a6f2ae99df Remap the primary heating system and compose the heating override trio 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:06:52 +00:00
Jun-te Kim
2ede859158 Decode regular/CPSU/storage/direct-electric heating overrides 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:05:39 +00:00
Jun-te Kim
21afbefa9d Resolve a landlord gas-combi heating override to its SAP code 🟥
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:05:00 +00:00
Jun-te Kim
b5ef41ea62 Remap the EPC hot-water arrangement from a landlord override 🟩
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-06-19 14:04:33 +00:00