Supersedes the "direct-acting electric drags no control/category" pin:
None does not mean unset — it means inherit the replaced system's value
(ADR-0048 bug class), verified suppressing HHRSH on portfolio 796.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Golden cert 0330 now reaches band C on the dwelling-sized ASHP alone
(ADR-0049), dropping its solid_floor_insulation companion; cert 0390
still fires three measures, so the per-measure trigger-attribute
assertions move there (and gain the lighting triggers).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
`from_sap_schema_17_1` hardcoded is_dwelling_export_capable=False, so
SAP 10.2 Appendix M1 zeroed the PV export credit on every export-capable
full-SAP cert. Cert 0380-3044-6070-2305-5925 (property 741840, PRD #1435
WS3) now reproduces its lodged 92 exactly (was 89); the existing
19.1.0 pin 10096028301 closes its documented -1 residual (84 -> 85 =
lodged). The full-SAP top-level pv_connection is deliberately NOT
carried: its enum disagrees with the RdSAP one the calculator gates on.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Regression guard: category 8 + control 2701 keep the ADR-0048 coherence
invariant satisfied for SAP codes 421/422/424.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Sizing selects the aroTHERM plus rung nearest PSR ~0.8 (0.8 x design heat
loss) — the Appendix-N efficiency peak, reproducing the pump a real
installer fits — rather than the MCS PSR>=1.0 capacity target, which
oversizes. Validated against the relodged Elmhurst ASHP cert (delta 0
held at the 5 kW Vaillant); the two self-snapshot pins re-pin to their
correctly-sized larger pumps, and the orchestrator/harness thread the
calculator's design heat loss so production sizes to the dwelling. Manual
SapResult test stubs carry the new design_heat_loss_kw field.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
_ashp_option now selects the aroTHERM plus PCDB record matching the
threaded design heat loss (floor-area proxy fallback), so the overlay's
efficiency anchor is sized to the dwelling instead of a fixed 5 kW unit.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Walked the water-heating worksheet section: assumed occupancy (42) matched
exactly (2.4234 both sides), but (43) average daily hot water use was
117.41 L/day (Elmhurst) vs 110.73 L/day (ours) — same occupancy, different
shower/bath demand. Root cause: the cert's shower_outlets field is
genuinely unlodged, which the mapper correctly maps to 0 mixer showers
per its documented, already-validated "no entry = no shower" convention.
Elmhurst's build shows a "Non-electric shower" fixture anyway — its UI
silently defaults one when the build script doesn't explicitly configure
"0 showers" to match the cert.
Verified: a single 7 L/min vented mixer reproduces Elmhurst's (42a)
monthly series exactly (4 d.p., all 12 months) and closes hot water to
2616.04 vs Elmhurst's 2616.03. Corpus-wide check across 170 certs sharing
this "bath present, no shower data" pattern shows no systematic bias
(mean dSAP +0.12, median -0.04) — confirms the mapper convention is
correct on average; this is a build-entry artifact on this one cert, not
a mapper bug (no code change warranted).
Combining all three found causes (window orientation, Table 11, shower
default): SAP 72.4567 vs Elmhurst's precise 72.0681 — residual 0.39,
~91% of the original 4.26-point gap now precisely explained.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Walked the worksheet section-by-section (dimensions, ventilation, fabric,
internal/solar gains, MIT, space-heating requirement, fuel cost) against
the calculator's matching intermediates. Internal gains and heat loss
matched closely, but solar gains (worksheet line 83) was 2.2x off in
January (56.9 W vs our 123.4 W) — traced to the Elmhurst BUILD entering
all 12 real windows (3 orientations: NW 7.05 m2, NE 1.21 m2, SE 7.06 m2)
as a single synthetic 15.32 m2 "North" group, understating solar gain.
Verified by reproducing both build artifacts in the calculator: real
windows + real Table-11 gating = 76.33 (our answer, matches lodged 76
exactly); collapsing to a synthetic single-North window + forcing Table
11 on = 72.62, reproducing Elmhurst's 72 almost exactly. Confirms neither
residual is a mapping or calculator bug — one is a deliberate,
regression-tested spec choice (Table 11) and the other is an artifact of
how this specific Elmhurst reconciliation build was entered.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
The prior comment blamed a stale build-side combi artifact (already fixed
this session) and my earlier conversational claim that Elmhurst's overall
SAP used regional weather was wrong too — verified the worksheet's (5)
dwelling volume and wind table match our UK-average rating cascade exactly.
The actual, now-quantified driver: Elmhurst's worksheet (201)/(202)/(215)
show it unconditionally applies SAP 10.2 Table 11's 10% secondary/portable-
electric-heater fraction based on main heating category alone, with no
secondary lodged on the cert. Our `_secondary_fraction` deliberately gates
this on an actual lodged/forced secondary (see the adjacent S-B30 note:
applying it unconditionally regressed the full 1000-cert corpus MAE by
+0.16). Forcing Table 11 on for just this cert moves 76.33 -> 73.62 (~62%
of the 76.33-vs-72 gap) — confirms this, not a mapping error, drives the
residual. Documented so the next reader doesn't re-litigate it.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
_has_suspended_timber_floor_per_spec only read the Main bp's per-part
floor_construction_type lodgement; the gov-API mapper frequently leaves
that None even when the global epc.floors[].description carries an
explicit "Suspended, ..." observation. _main_floor_u_value already fell
back to this joined description for the U-value calc — the infiltration
rule did not, so a genuinely suspended-timber floor silently entered
(12)=0 instead of 0.2 unsealed. Extracted the shared
_effective_floor_description helper and added a tri-state resolver
(explicit lodgement -> description, excluding "not timber" -> Table 19
footnote-1 age-A/B default) so both paths agree.
Cert 100061275133 (Elmhurst-validated build, PR #1439 handoff): engine
77.24 -> 76.33, now an exact match to lodged (76). Corpus gauge 77.7% ->
77.8% within-0.5, MAE 0.637 -> 0.636; floors ratcheted.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Electric-tariff cluster investigation. The 112-cert electric-main cohort is
mixed-sign within every category/meter - no systematic tariff bias. Root cause
of the biggest non-xfail divergences (10012334488 +13.2, 10091578598 +7.81):
SAP code 195 = 'Electric water storage boiler' (Table 4a p.170), which SAP 10.2
§12 Rule 2 correctly bills mostly at the 7-hour off-peak rate. Both are pure
cost gaps (PE/CO2 match lodged -> demand right); the lodged software over-billed
the storage boilers at peak rate. The engine is SPEC-FAITHFUL - matching lodged
would tune against §12/Table-4a. Pinned to the spec-faithful engine values.
Adds scripts/corpus_1000/elec_cohort.py (electric-main cohort analyzer).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Final two clean single-main gas certs. Both small cost-side residuals (+1.04 /
-1.01 SAP) on cavity-insulated fabric already Elmhurst-validated on sibling
certs, with properly-insulated cylinders (insulation type 1, 50/80mm - not the
type-0/NULL zero-storage-loss bug). No fabric anomaly; the register data fully
explains the engine output. Pinned to observed engine 71 / 79.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2-storey semi, solid brick 400mm with EXTERNAL insulation, 300mm loft,
suspended uninsulated ground floor, gas combi, double glazing (glazed_type 13).
Built in accredited Elmhurst RdSAP10: roof (U 0.14, 5.459 W/K) and windows
(15.32 x eff U 1.3258 = 20.311 W/K) match the engine EXACTLY; the
externally-insulated wall is engine U 0.29 vs Elmhurst 0.30, validating the
slice-5 external-insulation default (100mm added over solid brick); suspended
ground floor engine 0.68 vs Elmhurst 0.70. Elmhurst's overall SAP 67 is not
comparable (reused-assessment Standard-Combi keep-hot loss, a build artifact).
Engine 77 vs lodged 76 (within 1.24). Pinned to the observed 77.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Top-floor flat, solid brick uninsulated, uninsulated flat roof, gas combi,
SINGLE glazing (glazed_type 5). Built in accredited Elmhurst RdSAP10 and every
heat-loss element matches the engine EXACTLY: walls 53.18, flat roof 145.57,
floor 0, party 0, and — with the faithful single glazing — windows 34.7114 W/K
(8.62 m2 x eff U 4.0268). Confirms the mapper's glazed_type 5 -> single (raw U
4.8) is spec-correct per epc_codes.csv, not the double it superficially
resembles. Engine 61 vs lodged 62; the -1.18 is a cost-side residual, not a
fabric bug. Pinned to the observed engine 61.
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
SOLVED the window-grid blocker (per Junte's "keep one and edit, don't
delete all"): set_single_window now ADDS the fresh window (it inserts at
DOM index 0), then deletes the STALE rows BELOW it by index (high->low,
never index 0) via the per-row Delete image button + JS-clicked Yes modal.
The freshly-added row survives as the single window; no 0.00 junk strands
to block the Recommendations gate. Verified end-to-end: cert 100050881708
built, worksheet downloaded, walls (0.70) + roof (0.19) match the engine
EXACTLY. Combined with the earlier fill+Tab (area postback) + frame/gap
(validation) fixes, the per-cert loop now runs autonomously on clean
single-main certs.
Pin: 100050881708 (semi, cavity filled, pitched 225mm, suspended ground
floor, combi) engine 72 = lodged 70 +2; walls/roof accredited-Elmhurst-
matched. NB the build entered the suspended ground floor as an upper
"above unheated space" floor, so Elmhurst's worksheet SAP (61) is not a
clean comparison — the engine uses the correct §3.12 suspended-ground U
(0.74); the pin rests on the walls+roof match + lodged.
No engine change.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
A FLAT roof lodges its insulation thickness in the DEDICATED gov-EPC API
`flat_roof_insulation_thickness` field (e.g. "75mm"), leaving
`roof_insulation_thickness` None (that field is for pitched-loft joists).
`heat_transmission_from_cert` read only the latter, so a measured
flat-roof thickness was ignored and the roof billed at the uninsulated
age-band flat default (age E = 1.5) instead of its Table-16 insulated U.
Fixed by preferring `flat_roof_insulation_thickness` when the part is a
flat roof — the exact mirror of the existing rafter-thickness branch.
An "AB"/"NI" (as-built/unknown) value parses to None and keeps the
age-band default, unchanged; only measured thicknesses move.
PER-CERT ELMHURST VALIDATION (cert 47084930, top-floor flat, flat roof
75 mm): built on the lodged inputs in accredited Elmhurst RdSAP10-Online
(evidence saved: elmhurst_summary.pdf / elmhurst_worksheet.pdf). The
worksheet bills "insulated flat roof" at U 0.5 (floor 0.70 + wall 0.25
also matching the engine). The fix takes the engine roof 96.4 -> 32.1 W/K
(= 64.26 x 0.5, Elmhurst-exact), PE +47 -> +0.2, SAP 69.51 -> 74.34 =
lodged 74.
Gauge: within 77.3% -> 77.7%, SAP MAE 0.648 -> 0.641, CO2 0.074 -> 0.072,
PE 3.1 -> 2.97. Unit-pinned in test_heat_transmission
(flat_roof_insulation_thickness -> U 0.5); RealCertExpectation 47084930
= 74 (Elmhurst-validated). Also adds the build script build_47084930.py.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>